UPSONIC POWER DSV600 DSV Series UPS User Manual

June 13, 2024
UPSONIC POWER

UPSONIC LOGO RELIABLE POWER SOLUTIONS FOR A NON-STOP WORLD
DSV Series UPS
User Manual

DSV600 DSV Series UPS

UPSONIC POWER DSV600 DSV Series UPS

DSV600, DSV800, DSV1000, DSV2000
Uninterrupble Power Supply

SAVE THESE INSTRUCTIONS –
This manual contains important instructors for models DSV 600/DSV 800/DSV 1000/ DSV  2000  series  that should be followed during install and maintenance of   the UPS and bakeries.

  • This product is not recommended for use with any medical equipment, life-supping system or  other specific important equipment, we recommend you consult your supplier for a suitable solion.

  • Do not plug household appliances such as hair dryers, microwave ovens or vacuum cleaners into this   UPS.

  • Do not each a power board or surge suppressor to the UPS.

  • Do not plug the UPS into its own output.

  • Connexon to any other type of receptacle other than a standard Australian socket outlet may result in the hazard of electrical shock and may violate local electrical codes.

  • To reduce risk of overheated UPS, do not cover the UPS´ cooling vents.
    This unit is intended for install on in a controlled environment (temperature controlled, indoor area free of conduce contaminants). Avoid installing the UPS in lokao’s where there is water or  excessive humidity and do not use it in any of the following environments:
    o Any area with comb use gas, corrosive substance or heavy dust.
    o Any area with extraordinarily high or low temperature (above 40˚ C or below 0˚ C) and humidity of more than 90%.
    o Any area exposed to direct sunshine or near any hyang apparatus.
    o Any area with serious virions.
    o Outdoor.

  • The unity power outlet should be near the equipment and easily accessible. In the event of an emergency, press the OFF boon and disconnect the power cord from the AC power supply to properly disable the UPS.

  • Internal short curculio the UPS will lead to dangers such as electric shock or fire; therefore do not allow liquids or any foreign object to enter the UPS. No water containers (such as a glass of  liquid) or any other liquid-containing vessels to be placed on the top of the UPS.

  • Please do not use the UPS in excess of the rated load capacity.

  • Turn off and unplug the UPS prior to cleaning and do not use liquid or spray cleaners

  • Risk of electric shock, do not tempt to disassemble the unit. No user serviceable parts inside. Refer servicing to qualified service personnel.

  • If UPS is to be stored for a long me, it is recommended to recharge the bakeries (by connecng the unity power to UPS, switch “ON”), once a month for 24 hours to avoid a full beery discharge.

  • The UPS contains one or two large-capacity batteries. So the case should not be opened, as there is a danger of electric shock. If battery replacement is required, please contact the distributor.

  • Servicing should be performed or supervised by personnel knowledgeable of batteries and the required precautions. Keep unauthorized personnel away from batteries.

  • A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batteries:
    o Remove watches, rings, or other metal objects from the hand.
    o Use tools with insulated handles and wear rubber gloves and boots.
    o Do not lay tools or metal parts on top of batteries.
    o Disconnect charging source prior to connecting or disconnecting battery terminals.

  • When replacing batteries, replace with the same type and number of the sealed lead-acid batteries.

  • The maximum ambient temperature rating is 40°C.

  • Do not dispose of any battery in a fire. The battery may explode.

  • Do not open or mutilate any battery. Released electrolyte is harmful to the skin and eyes. It may be toxic, dispose of through a recycler

  • Icon (D on the rating label stands for single phase.

  • This pluggable type A equipment with battery already installed is” plug and play”

  • During the installation of this equipment it should be assured that the total current leakage of the UPS and the connected load does not exceed 3.5mA.

  • Attention, if disconnecting the UPS from the mains, hazardous voltage may exist from the battery. The battery must be disconnected from the positive and negative terminals before any maintenance or service work inside the UPS is attempted.

  • In the event of fire in the vicinity, only use dry-power extinguishers. The use of liquid extinguishers may expose you to an electric shock.

This product complies with the safety and environmental regulations in EU. and RCM645
To discard your product, please recycle all the components possible. Batteries and rechargeable batteries are not to be disposed in your domestic waste! Please recycle them at your local recycling point. Together we can help to protect the environment.

Introduction

The DSV model of UPS is an intelligent and compact line interactive UPS (Uninterruptable Power Supply) which is designed to protect your personal computer or sensitive electronic equipment’s from all forms of power interference, including complete power failures. It is equipped with many features that enable any attached equipment to operate after mains power failure and protect against power anomalies.

Description of Features

  • Easy to use and install microprocessor control to maximize reliability and efficiency
  • Equipped with built-in boost and buck AVR function
  • DC Cold start function
  • Auto restart when AC recovery.
  • Provides AC Overload protection
  • RJ11/RJ45 (in/out) LAN/Modem/Phone line protection

Product Overview

Front Panel

UPSONIC POWER DSV600 DSV Series UPS - Front Panel

  1. Display****
    When LCD starts to work, it will display all Informa for 3 seconds.| When in normal mode, it will display as below.
    ---|---
    UPSONIC POWER DSV600 DSV Series UPS - Display| UPSONIC POWER DSV600 DSV Series UPS - Display1
    When in AVR mode, it will display as below. And the  mark will flicker every 1second.| When in beery mode, it will display as below. And the mark will flicker every 1second.
    |
    When in off but power on and charging , it will display as below.|

In fault mode, it will display as below. “FAULT” character and “0” character only.

|

  1. Load level definition:

Load level

| Load bar Indication
---|---
| 0%~25%
| 25%~50%
| 50%~75%
****| 75%~100%

  1. Battery capacity definition:
    1x Beery mode: DSV 600, DSV 800Battery Level| Battery bar Indication
    ---|---
    UPS On Battery mode| UPS on Mains Power
    | Battery voltage<11V| Battery voltage<12.7V
    UPSONIC POWER DSV600 DSV Series UPS - Baery Level1| 11V≤battery voltage<11.5V| 12.7V≤battery voltage<13.2V
    | 11.5V≤battery voltage<12.5V| 13.2V≤battery voltage<13.5V
    | Battery voltage≥12.5V| Battery voltage≥13.5V

2 x Beery model:DSV 1000, DSV 2000

Battery Level

| Battery bar Indication
---|---
UPS on Battery mode| UPS on Mains Power
| Battery voltage<22V| Battery voltage<25.4V
UPSONIC POWER DSV600 DSV Series UPS - Baery Level1| 22V≤battery voltage<23V| 25.4V≤battery voltage<26.4V
| 23V≤battery voltage<25V| 26.4V≤battery voltage<27V
| Battery voltage≥25V| Battery voltage≥27V
4. If UPS is over load, the mark will flicker every 1second. 5. When battery is low, the mark will flicker every 1second.

Back Panel:

| UPSONIC POWER DSV600 DSV Series UPS - Back Panel1
---|---
1. AC input
2. 2Australia outlet
3. RJ11 Modem/phone line protection| 1. AC input
2. 4
Australia outlet
3. USB port
4. RJ45 LAN/Modem/phone line protection
5. Breaker

Installation and Initial Startup

UPSONIC POWER DSV600 DSV Series UPS - Startup Before installation, please inspect the unit. to ensure nothing is damaged.
I: Placement & Storage Conditions
Install the UPS in a protected area free of excessive dust and ensure adequate air flow around the unit, and ensure it biasfree from any corrosive fumes or conductive contaminants. Please place the UPS away from other units at least 20 cm to avoid interference. Battery condition is best suited to operating temperatures 20-25° C .UPSONIC POWER DSV600 DSV Series UPS - Storage
Condions
II: Connect to Utility and Charge
Plug the AC input cord in to the socket outlet. For the best results, we suggest charging the battery at least 6 hours with no load (no electrical devices such as computers, monitors, etc.) connected before initial use. The unit charges its battery when connected to the utility. UPSONIC POWER DSV600
DSV Series UPS - Charge

Plug in the loads to output receptacles on the rear panel of the UPS. Turn the power switch of UPS on, then turn connected devices on All units connected to the UPS will be protected by the UPS.
Do not each a power strip or surge suppressor to the UPS.
IV: Connect LAN cable, Modem or Phone line for Surge Protection
Connect a single modem or phone line into the surge-protected “IN” jack on the back panel of the UPS.
Connect from “OUT” outlet to the phone or modem with another phone cable.UPSONIC POWER DSV600 DSV Series UPS - Modem

V: Connect USB Cable
To monitor the UPS status, such as untended UPS shutdown and start-up, using bundled soared, please connect the UPS and PC with USB cable included.UPSONIC POWER DSV600 DSV Series UPS - USB
Cable

NEVER connect a laser printer or scanner to the
UPS unit, because in-rush current generated by the devices motor’s may overload and damage the UPS
VI: Turn On/Off the UPS
Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing the power switch again.
UPSONIC POWER DSV600 DSV Series UPS - UPS

Functions & Operation

I: DC Start Function DC Start Function enables the UPS to be started on battery when AC utility power is not available and the battery is fully charged. Just press the power switch to turn on the UPS.
II: AVR (Automatic Voltage Regulation) If the quality of the incoming mains is poor, the AVR boosts a low incoming voltage or reduces (bucks) a high one. The load receives a voltage within a normal range.
III: Auto restart while AC recovery When AC power recovers the UPS will power up and start charging the battery IV: Audio Indicator

Audible Alarm Situation
Sounding every 10 UPS on Beery
seconds Mode
Sounding every 1 second Beery Low
Sounding every 0.5 seconds UPS is in Overload
Cernuous sounding UPS is Faulty

Software Installation on your PC

Connected by USB to a PC or notebook, the Software enables communication between the UPS and the computer. The UPS software monitors the status of the UPS, shuts down the system before the UPS is exhausted and can remotely observe the UPS via the Network (enabling users to manage their system more effectively). Upon AC failure or UPS battery low, UPS takes all necessary actions without intervention from the system administrator. In addition to automatic file saving and system shut-down functions, it can also send warning messages via pager, e-mail etc.

  • Use the bundled CD and follow the on-screen instructions to install the software Win Power.
  • Enter the following serial No. to install software: 511C1-01220-0100-478DF2A
  • After the software is successfully installed, and communication with UPS has been established a green icon will appear in the system tray.
  • Double-click the icon to use the monitoring software.
  • You can schedule UPS shutdown/start-up and monitor UPS status through PC.
  • Detail instructions please refer to the e-man ua I in the software.

**** Check http://www.ups-software-download.com/index.htm from time to time to get the latest updates version of monitoring software.

Maintenance

I. General
The UPS is virtually maintenance free: maintain proper environmental conditions and keep air inlets-outlets free of obstructions and dust.
II. Fuses
If the UPS is overloaded and the AC input fuse blows, be sure it is replaced by a compatible fuse of the same make and type.
Never short circuit batteries. When working with batteries, remove watches, rings and other metal objects, and only use insulated tools.
III. Batteries
Read all safety rules before attempting to replace the battery.
If replacing the batteries, use batteries with exactly the same specifications.

Trouble Shooting

Symptom Possible Cause Remedy
No LED display on the front panel. 1. Battery weak. 1. Charge battery up

to 8 hours.
2. Battery defect.| 2.Replace with the same type of battery.
3.No Utility Power.| 3. Press the power switch again.
Alarm buzzer beeps continuously when AC supply is normal.| Overload of the UPS.| Verify that the load matches the UPS capability specified in the specs. Remove some of the load
When power failure, back-up time is shorter than normal.| 1. UPS Overloaded| 1. Remove some non-critical load.
2. Battery weak.| 2.Charge battery up to 8 hours.
3.Battery weak due to age, high temperature, or environment,.| 3. Replace with the same type of battery.
Mains normal but LED is flashing.| Power cord is loose.| Reconnect the power cord properly.

If any abnormal situations occur that are not listed above, please call service people immediately.

Specifications

Model DSV 600 DSV 800 DSV 1000 DSV 2000
CAPACITY 600VA/360W 800VA/480W 1000VA/600W 2000VA/1200W

INPUT
Voltage| 230 VAC
Voltage Range| 170280 VAC
OUTPUT
Voltage| 220/230/240 VAC
Voltage Regulation| +/-10% (Battery mode)
Frequency Range| 50/60Hz (Auto sensing)
Frequency Regulation| ±1Hz (Battery mode)
Transfer Time| Typical 4-8ms
Waveform| Modified Sine Wave
PROTECTION
Full protection| Discharge, overcharge and overload protection
ENVIRONMENT
Humidity| 0-90 % RH @ 0° to 40° C (non-condensing)
Noise Level| Less than 40dB 45dB
Software
Monitoring Software| Win Power (included)
BATTERY
Type & Number| 12V/7Ah x 1| I 12V/9Ah x 1| I 12V/7Ah x 2| I 12V/9Ah x 2
Charging Time| 6 hours recover to 90% capacity
Backup Time (est. 100W)| 16 min| I 20 min| I 30 min| I 50 min
PHYSICAL
LCD Indicator| LCD display
Outlet| 2 x Australia outlets| 4 x Australia outlets
Connector| USB port, R111 Surge Protection| USB port, R145 Surge Protection
Dimension (WxDxH)| 290mm x 100mm x 143mm| 364mm x 139mm x 195 mm
WEIGHT
Net weight| 4.4kg| I 5.2kg| I 8.9kg| I 10.4kg