Numatic NQ100 Quick Commercial Battery Stick Vacuum Cleaner Instruction Manual
- June 4, 2024
- Numatic
Table of Contents
- NQ100 Quick Commercial Battery Stick Vacuum Cleaner
- Index
- Box Contents
- Main Assembly
- Accessory Fitting
- Battery Fitting
- Battery Removal
- Control Panel
- Scent Capsule Fitting
- Floor Tool Air Bleed Control
- Charger Wall Mounting
- Accessory Storage
- Disposable Pod Emptying
- Disposable Pod Fitting
- Extension Handle Fitting
- Machine Charging
- Floortool Hose Cleaning
- Brush Roller Removal & Cleaning
- Machine data
- Trouble Shooting
- About your machine
- Maintenance
- Information for Dry use Battery Vacuum cleaners
- Battery Information
- Important Warnings – Batteries
- Care and Disposal of Li-Ion Batteries
- First Aid Measures
- Schematic diagram
- Replacement parts
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
(NQ.100)
NQ100 Quick Commercial Battery Stick Vacuum Cleaner
Original Instructions
CAUTION, Read instructions before using the machine
KEEP FOR FUTURE REFERENCE
Index
1 | Extension handle | Page 9 |
---|---|---|
2 | Battery pack | Page 4, 5 & 10 |
3 | Charging Port | Page 7 &10 |
4 | Filter Pod / Tank | Page 8 |
5 | Hose | Page 11 |
6 | Brush release button | Page 12 |
7 | Brush release panel | Page 12 |
8 | Scent capsule cover | Page 6 |
9 | Control Panel | Page 5 &10 |
10 | Lid release / Pod Eject | Page 8 |
11 | Lid Catch | Page 8 |
12 | Release Button | Page 4 |
13 | Wand Section | Page 4 |
14 | Hose release | Page 11 |
15 | Brush Roll | Page 12 |
Box Contents
Main Assembly
Accessory Fitting
Battery Fitting
Battery Removal
Control Panel
Scent Capsule Fitting
Floor Tool Air Bleed Control
Charger Wall Mounting
Accessory Storage
Disposable Pod Emptying
Disposable Pod Fitting
Extension Handle Fitting
Machine Charging
Floortool Hose Cleaning
Brush Roller Removal & Cleaning
Machine data
Model| Voltage| Protection class| Weight
(Ready to work) See Fig (A)| Sound pressure (LpA) Uncertainty (KpA)|
Run Time
---|---|---|---|---|---
NQ.100| 25.2 V| Class III| 3.2 kg| 77 dB (A)
0.5 dB| 70 min (Low — Brush OFF) 55 min (Low — Brush ON) 16 min (High — Brush
OFF) 14 min (High — Brush ON)
Pod
Capacity| Charging
Times| Rated Power| Hand / Arm Vibration| Dimensions LxWxH I
1 L| 15 mins
to 0100%| 300 W| 5
ah 2.5 mis2| 270 mm x 240 mm x 1220 mm
*Run and Recharge times may vary dependent on ambient temperature and expected battery aging.
Trouble Shooting
No. | Problem | Possible Reason | Solution |
---|---|---|---|
1 | Large RED light on the control panel is flashing | There may be a blockage | |
in the system | Check the floorhead hose, wands, connections and accessories, |
and remove any blockages, page 11
The filter pod may be full| If there are no blockages in the system, eject and
replace the filter pod, page 8
2| The machine is difficult to push on the carpet| The carpet pile is very
deep or dense and can cause high pressure inside the floor head| Open the air
valve on top of the floorhead to reduce pressure, page 6
Switch the machine from boost to normal mode, page 5
3| Floor brush cuts out on rugs or carpet| The carpet or rug pile is very deep
and can cause high pressure on the brush, the safety system cuts power to the
brush| Switch off the floor brush from the control panel, page 5
Switch the machine from boost to normal mode, page 5
4| Vacuum lifts area rugs| The vacuum suction may be too high and/or the brush
roll is picking up the rug| Switch the machine from boost to normal mode and
switch off the brush roll, page 5
Adjust floor Tool Air Bleed Control page 6
5| The floor head is not picking up hair or fibers| The floor brush has
excessive hair wrapped around it| Remove the floor brush from the floor head
and clean, page 12
There is a partial blockage in the floor head or wands| Check the floorhead
hose and
wands, remove any blockages, page 11/12
6| No power at rotating floor brush| The brush head button is switched off|
Switch the machine off and then back on again, page 5
7| The machine will not power up after prolonged use| The machine is equipped
with a motor-protective thermostat as well as battery extreme temperatures
protections, the system temperatures are outside of working parameters| Allow
the machine and the battery to cool down
About your machine
Floor Tool Label
Battery Label
Maintenance
Daily
Keep the machine and all parts clean, including hoses and tubes.
Ensure the fi lter pod is fi tted.
Regularly examine the charger.
Check fi lter pod frequently and renew if required.
Weekly – as daily and: Check for any worn or damaged parts and replace
them immediately.
Batteries
Always recharge the batteries after use.
WEEE (Waste, Electrical, and Electronic Equipment)
Accessories and packaging should be sorted for environmentally-friendly
recycling.
Only for UK/EU countries.
Do not dispose of household waste.
According to the European Directive 2012/19/EU on waste electrical electronic
equipment and its incorporation into national law.
Items that are no longer suitable for use must be separated, collected, and
sent for recovery in an environmentally-friendly manner. ****
PPE (Personal protective equipment) may be required for certain operations.
__
|
|
__
|
|
__
---|---|---|---|---
Ear Protection| Safety Footwear| Head Protection| Safety Gloves
__
|
__
|
__
|
__
Dust / Allergens Protection| Eye Protection| Protective Clothing| Hi-Vis Jacket| Caution Wet Floor Sign
NOTE: A risk assessment should be conducted to determine which PPE should
be worn.
Failure to rectify the problem or in the event of a breakdown contact your
Numatic
dealer or the Numatic Technical helpline +44 (0)1460 269268
Information for Dry use Battery Vacuum cleaners
Warning
Read the instruction manual before using the machine.
Operators shall be adequately instructed on the use of these machines, as with
all electrical equipment, care and attention must be exercised at all times
during use, you must also make certain that routine and preventative
maintenance is carried out periodically to ensure safe operation. Failure to
carry out maintenance as necessary, including the replacement of parts to the
correct standard could render this equipment unsafe and the manufacturer can
accept no responsibility in this respect. This machine is for DRY USE only.
When charging the appliance make sure that the charging lead is safely secured
and the jack is properly inserted into the battery. Keep hair, loose clothing,
fingers and all parts of the body away from openings and moving parts. You
must remove the battery from the machine BEFORE cleaning or maintenance and
when replacing parts or converting the machine to another function. This
appliance is intended to be assembled, cleaned, and maintained by an adult.
This machine is not suitable for the collection of biological hazards, and
hazardous or explosive dust.
Contact your local distributor if you require a machine capable of performing
these tasks.
This machine is not intended for use by persons (including children) with
reduced physical, sensory or mental capabilities, or lack of experience and
knowledge.
Keep scent capsules away from children, as they are harmful if swallowed.
Extra care must be taken when cleaning on stairs.
Children should be supervised to ensure that they do not play with the
appliance.
This machine is not a toy; children shall not play with this machine.
Caution
This machine must not be stored outside, used in wet environments, or
collected wet materials.
The vacuum cleaner should be stored in a dry place and is for indoor use only.
You must ensure that the machine is suitable for the material being collected.
Note:
The primary use for this machine is for domestic, as well as commercial
settings, for example in homes,
hotels, schools, hospitals, factories, shops, and offices.
This vacuum cleaner is fitted with a thermal protection device.
If the vacuum cleaner has a blockage, remove the battery and inspect the floor
tool, tubes, and hose for debris.
If the floor tool, tubes, and hose are clear, replace the filter pod.
The vacuum cleaner should be inspected after use for damage.
When moving from one place to another, consider the weight of the machine.
Do
Keep your machine clean including hoses and tubes.
Change the filter pod frequently.
Keep hoses and tubes clear.
Replace any worn or damaged parts immediately.
Use OEM specifi ed Numatic Scent Capsules only as shown in this manual.
Don’t
Use to suck up hot ashes or lighted cigarette ends.
Use steam cleaners or pressure washers to clean the machine or use it in the
rain.
Immerse in water for cleaning.
Attempt machine maintenance or cleaning unless the battery has been removed
from the machine.
Under any circumstances place foreign objects i.e. air fresheners, air
freshener capsules or scented beads, or any other object not originally
supplied as part of the machine or OEM accessory pack, into the machine.
Doing so can be dangerous and risks damage to the machine and may also
invalidate the machine warranty.
Battery Information
NOTE:- It is recommended that a battery is fully charged before fi first
use.
Important Warnings – Charger
Read all these warnings before using the charger.
- CAUTION! Charge only Numatic Lithium-Ion batteries, other types of batteries may burst to cause personal injury and damage.
- Do not charge damaged batteries.
- Do only charge dry batteries.
- Check the charger cable regularly for any sign of damage. If the charger cable is damaged the charger should be replaced, by an original NUMATIC INTERNATIONAL charger available fromthe manufacturer or service agent.
- Do not use damaged chargers.
- Protect the charger against moisture and store it in a dry place.
- Do not use the charger if it is wet or handle the charger with wet hands.
- The mains voltage available must correspond to the voltage stated on the rating plate of the charger.
- The no-load voltage of the charger is 30 V.
- Do not operate the charger in an explosive environment.
- Do not carry the charger by holding the charger cord.
- Do not unplug by pulling on the cord. To unplug, grasp the charger, not the cord.
- Do not cover the charger whilst charging.
- Do not open the charger. Repairs shall be done only by authorized personnel.
Warning:
The battery included in this product must only be charged by the Numatic
Charger supplied with the product under NO circumstances should an alternative
non-Numatic charger be used as there is a risk of severe damage and fi re could
result. Only use genuine Numatic parts.
Instructions for Use – Charging Batteries
The charger is capable of operating at different main voltages and frequencies
without user adjustment.
Ensure the charger jack plug is fully inserted into the battery. (see page 10)
If the charger is damaged or does not charge anymore, do not use the charger
and contact your supplier.
Make sure charger replacements are a genuine Numatic service parts.
Health Hazards (Acute & Chronic).
The chemicals used in the battery are in a sealed container.
The risk of exposure only occurs if the battery is abused or damaged.
Contact of electrolytes and lithium with skin and eyes should be avoided.
Signs & Symptoms of Exposure.
A damaged or leaking battery can cause chemical burns upon contact.
Such a situation might only occur when the battery cell is opened or damaged.
Important Warnings – Batteries
Read all the warnings before using the battery.
This cleaner uses Numatic Lithium-Ion batteries. Used batteries should be
disposed of safely and placed in a sealed plastic bag and then handled
according to all locally approved precautions and environmental regulations.
a)Do not dismantle, open or shred batteries.
b)Do not expose batteries to heat or fire. Avoid storage in direct sunlight.
c)Do not short-circuit a battery. Do not store batteries haphazardly in a box
or drawer where they may short-circuit each other or be short-circuited by
other metal objects.
d)Do not remove a battery from its original packaging until required for use.
e)Do not subject batteries to mechanical shock.
f)In the event of battery leaking, do not allow the liquid to come in contact
with the skin or eyes, and avoid inhaling fumes. If contact has been made,
wash the affected area with copious amounts of water and seek medical advice.
g)Do not use any charger other than that specifically provided for use with
the appliance.
h)Do not use any battery which is not designed for use with the appliance.
i)Use only original NUMATIC batteries, when replacement batteries are
required.
j)Keep batteries clean and dry.
k)Do not leave a battery on prolonged charge when not in use.
l)After extended periods of storage, it may be necessary to charge and
discharge the batteries several times to obtain maximum performance.
m) Retain the original appliance literature for future reference.
n) When possible, remove the battery from the equipment when not in use.
o) Do not immerse in any liquid.
p) Do not charge damaged batteries.
q)If the batteries are leaking, return batteries to a disposal plant or a
similar local facility.
r)The batteries must be removed from the appliance before the appliance is
scrapped.
s)If the appliance is to be stored unused for a long period, the batteries
should be removed.
The battery is equipped with electronic thermal protection, refer to the
Temperature and Humidity Range
The table below for recommended operating conditions.
Temperature and Humidity Range Table
Storing | +5 … +35 0C |
---|---|
Discharge | +5 … +35 0C |
Charge | +5 … +35 0C |
Shipment | -20 … +60 0C |
Humidity | 25 – 85% RH no condensation |
Long term storage
Humidity| ≤ 50% RH no condensation
In case the battery is subject to environmental conditions outside the above
parameters user must allow at least 3 hours for the battery to acclimatize at
room temperature before attempting to operate.
If the battery is found to be faulty at any time, contact Numatic
International, or World Wide Lithium-Ion Battery Technical Helpline at
+1-703-741-5970
Care and Disposal of Li-Ion Batteries
DEFECTIVE BATTERIES
ATTENTION
Please follow all safety guidelines set out.
A defective battery should not be stored inside buildings on any
account.
- If a customer wishes to return a battery to a supplier, then a collection of the battery must be arranged by the supplier, however, Faulty batteries must not be returned through the postal system or by courier.
- If on return to a supplier, OR at a customer base, a suspected defective battery shows any signs of impact damage, distortion, blistering, loose parts, or leakage then on no account should it be offered for condition checking. It must be considered defective and the procedures described followed.
- If, on return to a supplier, OR at a customer base, a suspected defective battery, that shows no signs of impact damage, distortion, blistering, loose parts, or leakage, maybe offered for condition checking with an appropriate battery condition checking device operated by a competent person.
- If on checking the battery is found to be operational then a single recharge cycle under observation can be attempted with the appropriate Numatic charger.
- If the battery recharges correctly on this single recharge cycle then it can be deemed a good battery.
- If the battery fails to recharge correctly on this single recharge cycle then it must be deemed a defective battery and the procedures followed.
- On no account must any further attempt to recharge be made.
- A defective battery should not be stored inside buildings on any account.
- The defective discharged battery can then be stored in a locked battery waste container which should be plastic or plastic lined and placed away from buildings and clearly signed as a defective battery container with appropriate warnings.
The battery is to be disposed of safely and in accordance with all locally approved precautions and environmental regulations.
First Aid Measures
If exposed to any of the Chemicals mentioned in the Hazards section please
follow the procedures below:
Eyes. Flush eyes with plenty of water for at least 15 minutes, occasionally
lifting the upper and lower eyelid.
Seek medical attention.
Skin.
Remove contaminated clothing and rinse skin with plenty of water or shower for
15 minutes.
Seek medical attention.
Inhalation.
Vacate from the site of exposure to fresh air immediately. Use oxygen if
available.
Ingestion.
Give at least two glasses of milk or water. Induce vomiting, unless the
patient is unconscious.
Seek medical attention.
Note:
Inhalation, skin contact, and eye contact are possible if the battery is
damaged.
Exposure to internal contents, the corrosive fumes will be very irritating to
skin, eyes, and mucous membranes.
Overexposure can cause symptoms of non-fibroid lung injury and membrane
irritation.
Schematic diagram
Replacement parts
Spares and Accessories
914745 | Numatic Battery Pack Assembly (25.2 V) Graphite |
---|---|
915242 | Battery Charger – UK Plug |
914746 | Numatic Floor Tool Graphite |
914592 | Pack of 10 Pods |
914593 | Pack of 10 Scent Capsules |
Numatic Quick Numatic International
WARRANTY
Numatic International Limited grants to the original purchaser a warranty
on the terms and for the period set out below:
Light Commercial Use……………………………………..1 year
Note:
This warranty expressly excludes consumable parts that are considered
replaceable from time to time during the normal working life of the machine.
Using non-Henry or Numatic Pods can be detrimental to both machine performance
and life and may invalidate the Warranty.
Failure to follow the relevant equipment Instruction Manual and Battery
Leaflet or use the correct Numatic or Henry charger will void your warranty.
A. The warranty period commences from the date the goods are purchased.
B. All warranty claims must be processed through the Dealer from whom the
equipment was purchased. The Dealer will cooperate with the purchaser
throughout the warranty claims procedure and will arrange any necessary
repairs using genuine Numatic parts.
C. If the original Dealer is no longer able to fulfill his obligations please
contact Numatic International Limited with full details of the claim and proof
of purchase so that this may be processed without delay.
D. Any warranty claim can only relate to the specific part that is proven to
be at fault and for which a replacement will be supplied but cannot be
extended to constitute a claim against the complete machine.
E. Numatic International will supply the Dealer with any warranty parts
required, subject to the claim being validated, after the return of the faulty
items in accordance with Numatic International Limited’s General Conditions of
Sale.
F. Claims will not be accepted if they are the result of fair wear and tear,
misuse, or abuse of any kind, or if they arise from failure to operate the
equipment in accordance with its Instruction Manual and/or Battery Leaflet.
G. No replacement will be given unless the appropriate evidence of the
validity of the claim has been provided to the satisfaction of Numatic
International Limited.
H. Numatic International Limited reserves the right to charge for any
unnecessary work carried out as a result of an invalid claim.
I. No variation to this warranty may be made or implied by any member of
Numatic International Limited or its Dealers unless such variation is in
writing and properly authorized by the Company.
Numatic International Limited, Chard, Somerset, TA20 2GB
Telephone 01460 68600 Fax: 01460 68458
© Numatic International Limited 21
UKCA Declaration of Conformity
Manufacturer:| Numatic International Limited Chard Somerset TA20 2GB www.numatic.co.uk
Product:| HEN, CITY, NQ
Description:| Vacuum Cleaner – Commercial – Dry
We, Numatic hereby declare under our sole responsibility, that the above-
mentioned product(s) is/are in conformity with the following directives and
standards.
5.1.| 2008:| 1597| Supply of Machinery Regulations| EN60335-1:2012 + AC:2014 +
A11:2014 + A13:2017 EN60335-2-69:2012
EN62233:2008
---|---|---|---|---
5.1.| 2016:| 1091| EMC Regulations| EN55014-1:2017 + A11:2020
EN55014-2:1997 + A1:2001 + A2:2008 EN61000-3-2:2014
EN61000-3-3:2013
5.1.| 2012:| 3032| RoHS Regulations|
Authorized Signatory: Mr. Matthew Coles Position: Head of Technology
Numatic International
Limited,
Chard,
Somerset, TA20 2GB, UK
EU, Declaration of Conformity
Manufacturer:| Numatic International Limited Chard Somerset TA20 2GB www.numatic.co.uk
Product:| HEN, CITY, NQ
Description:| Vacuum Cleaner – Commercial –Dry
We, Numatic hereby declare under our sole responsibility, that the
above-mentioned product(s) is/are in conformity with the following
directives and standards.
2006/42/EC| Machinery Directive| EN60335-1:2012 + AC:2014 + A11:2014 +
A13:2017 EN60335-2-69:2012
EN62233:2008
---|---|---
2014/30/EU| EMC Directive| EN55014-1:2017 + A11:2020
EN55014-2:1997 + A1:2001 + A2:2008
EN61000-3-2:2014
EN61000-3-3:2013
2011/65/EU| RoHS Directive|
Authorised Signatory: Mr. Matthew Coles Position: Head of Technology Numatic International Limited
Chard,
Somerset, TA20 2GB, UK
Numatic International Limited.
Chard, Somerset TA20 2GB ENGLAND
Tel: 01460 68600 www.numatic.co.uk
Numatic International (Pty.) Ltd.
16th & Pharmaceutical Roads, Midrand, Gauteng,
SOUTH AFRICA 1685
Tel: 0861 686 284 www.numatic.co.za
This Product has been comprehensively inspected and checked during every stage
of its manufacture.
Including an in-depth electrical safety and functionality test.
Specification subject to change without prior notice
numatic.com © Numatic International Limited