SUNAMP Thermino HP VT Heat Batteries Addendum User Manual

June 13, 2024
SUNAMP

SUNAMP Thermino HP VT Heat Batteries Addendum

Safety Notice

Symbols and Notices Used and Their MeaningsSUNAMP-Thermino-HP-VT-Heat-
Batteries-Addendum-FIG-1 \(1\)

  • This Addendum manual MUST be followed for Sunamp Thermino® Heat
  • Batteries installations with Vaillant Arotherm Plus High Temperature
  • Heat Pumps. This manual should be read in conjunction with the
  • Thermino hp & Thermino iPV Heat Batteries Installation and User Manual.
  • This Addendum manual ONLY contains relevant information on how to setup the hydraulics and electrics, between the Heat Battery and the
  • Vaillant Arotherm Plus Heat Pump for the install and what settings should be applied to the Vaillant Arotherm Plus, Heat Pump Interface and
  • Sensocomfort controls. This is to allow the correct control configuration between the Sunamp Thermino Heat Battery and the Vaillant Arotherm Plus.
  • Please note that Sunamp takes no responsibility for any other system configuration and installation other than what is documented in this Addendum manual.

Sunamp Thermino hp-VT

Sunamp Thermino hp-VT controller wiring diagramSUNAMP-Thermino-HP-VT-
Heat-Batteries-Addendum-FIG-1 \(2\)

Sunamp Thermino hp-VT wiring – Thermino hp-VT
Important: Please follow (Table 1) for information regarding the Links .SUNAMP-Thermino-HP-VT-Heat-Batteries-Addendum-FIG-1
\(8\)

Table 1: Wiring Thermino hp-VT – Link 1 & 2 settings
Link 3 will be provided fixed within the product; for this product type it MUST remain in place. Removing the Link 3 will result in increased consumption and running times of the Vaillant Arotherm Plus Heat Pump.

  • Run and connect 3 Core mains power supply cable (16A minimum, minimum 2.5mm? CA) from the Double-pole isolating switch to the Heat Battery controller (Figures 2 and 3).
  • Wire the cable via the appliance case grommets and into the control box housing (Thermino hp installation manual Figure 8 and Figures 2 and 3 below).
  • Prepare if necessary and wire the mains power cable in the following terminals (Thermino hp installation manual, Figure 10 and Figures 2 and 3 below):
    • Brown (Live): Terminal L1 (Live)
    • Blue (Neutral): Terminal N1 (Neutral)
    • Green/Yellow (Earth): Terminal PE (Protective Earth)

Electric override switch wiring
Wire a 2 core shielded PVC insulated cable (minimum 0.75mm? CSA, 24 x 0.2mm according to BS 6500) from a 2-pole Volt-free contact switch, run the wire into the appliance via the appliance case cabling grommets and then into the control box housing through the hole available. Secure the cables in Terminal T1 & T2 independently (Figure 2 & Figure 3).
Warning: Please DO NOT connect a fused spur for this connection.
Note: This switch should be off by default. Engaging this switch will put the Heat Battery into electric charging mode only and disable the function of the Vaillant Arotherm Plus Heat Pump until the switch is set to off. This can lead to increased electricity consumption, resulting in higher energy costs. This should be explained to the end user and the switch labelled accordingly.
External heat source sensor cable wiring
Wire a 2 core PVC insulated cable (minimum 0.75mm? CSA, 24 x 0.2mm according to BS 6500), the heat battery controller in this application acts as hot water thermostat. The cable will act as a hot water heating tank sensor from the heat battery controller terminals T3 & T4 into the Vaillant Heat Pump Interface controller SP1 screw terminals 1&2 (please refer to Vaillant Arotherm Plus Installation manual. Please run the wire into the heat battery appliance via the appliance case cabling grommets and then into the control box housing through the hole available. Secure the cables in Terminals T3 & T4 independently (Figure 2).SUNAMP-Thermino-HP-VT-Heat-Batteries-Addendum-FIG-1
\(3\)

Sunamp Thermino hp-VT hydronics and controls schematicSUNAMP-Thermino-HP-
VT-Heat-Batteries-Addendum-FIG-1 \(4\)SUNAMP-Thermino-HP-VT-Heat-Batteries-Addendum-FIG-1
\(9\)

Table 2: Explanation of components for Thermino hp-VT

Thermino hpPV-VT

Sunamp Thermino hpPV-VT controller wiring diagramSUNAMP-Thermino-HP-VT-
Heat-Batteries-Addendum-FIG-1 \(5\)

Sunamp Thermino hpPV-VT wiring
Important: Please follow (Table 3) for information regarding the Links .SUNAMP-Thermino-HP-VT-Heat-Batteries-Addendum-FIG-1
\(10\)

Table 3: Wiring Thermino hpPV-VT – Link 1 & 2 settings
Link 3 will be provided fixed within the product; for this product type it MUST remain in place. Removing the Link 3 will result in increased consumption and running times of the Vaillant Arotherm Plus Heat Pump.

  • Run and connect 4 Core mains power supply cable (16A, minimum 2.5mm? CA) from the Solar Power Diverter to the Heat Battery. (Thermino iPV installation manual, Section 3.9 and Figures 5 and 6 below).
  • Wire the cable via the appliance case grommets and into the control box housing (Thermino iPV installation manual, Figure 8 and Figures 5 and 6 below).
  • Prepare if necessary and wire the mains power cable in the following terminals (Thermino iPV installation manual, Figure 10 and Figure 5 and o below):
    • Brown (Live): Terminal L1 (Permanent Live)
    • Black (Live): Terminal L2 (Modulating Live)
    • Blue/ Grey (Neutral): Terminal N1 (Neutral)
    • Green/Yellow (Earth): Terminal PE (Protective Earth)

External heat source sensor cable wiring

  • Wire a 2 core shielded PVC insulated cable (minimum 0.75mm? C SA, 24 x 0.2mm according to BS 6500), the heat battery controller in this application acts as hot water thermostat. The cable will act as a hot water heating tank sensor from the heat battery controller terminals T3 & T4 into the Vaillant Heat Pump Interface controller SP1 screw terminals 1&2 (please refer to Vaillant Arotherm Plus Installation manual). Please run the wire into the heat battery appliance via the appliance case cabling grommets and then into the control box housing through the hole available. Secure the cables in Terminals T3 & T4 independently (Figure 5).SUNAMP-Thermino-HP-VT-Heat-Batteries-Addendum-FIG-1 \(6\)

Solar Power Diverter wiring
For wiring and setup of the Solar Power Diverter, please follow the instructions in section 3.9 of the “Thermino ePV & Thermino iPV Heat Batteries Installation and User Manual – D0043”

Thermino hPV-VT hydronic and controls schematicSUNAMP-Thermino-HP-VT-
Heat-Batteries-Addendum-FIG-1 \(7\)SUNAMP-Thermino-HP-VT-Heat-Batteries-Addendum-FIG-1
\(11\)

Table 4: Explanation of components for Thermino hPV -VT

Vaillant heat pump settings
Before making changes to the Vaillant Arotherm Plus Heat Pump controllers, first ensure that you have properly reviewed the previous sections of this Addendum manual and the Thermino hp & Thermino iPV, particularly in regard to Heat battery specifications as well as location, electrical supply and water supply requirements. This supported with the Vaillant Arotherm Plus Heat Pump Installation manual provided with the heat pump.
Vaillant Sensocomfort settings
In the Installer level menu please apply the following settings for DHW settings ONLY (please check Vaillant Arotherm Plus Sensocomfort installation and user manual),

Table 5: Vaillant Sensocomfort settings
NOTE: If following a DHW daily timed schedule, please ensure that a minimum time window in line with the installed heat battery and heat pump capacities is chosen and that potential defrost cycles during this window are accounted for.

Vaillant Heat Pump Interface settings
Change Heat pump Compressor output in DHW mode from Eco to Normal, this is available in the DHW settings of the Heat Pump Interface (please check Vaillant Arotherm Plus installation and user manual.

Other Information

Please refer to the Thermino hp or Thermino iPV Installation and User Manuals for other information regarding the Heat Battery Installation, such as: Maintenance, Troubleshooting, Commissioning, Warranty and Recycling.

CONTACT

  • Manual Part Number: D0047
  • Version Number: 1
  • Publication Date: 15/12/2021
  • Sunamp Ltd.
  • 1 Satellite Park
  • Macmerry
  • East Lothian
  • Scotland, EH33 1RY
  • General Enquiries +44 (0)1875 610001
  • [email protected].
  • www.sunamp.com.

Keep these instructions in a safe place for future reference Thermino® hp-VT & Thermino® hpPV-VT Heat Batteries Addendum Manual