The inrush current limiter SCL 3680 prevents unintentional triggering of the circuit breaker when switching on powerful loads such as angle grinders, circular saws, compressors, pumps or drills. The adapter plug reduces the load peaks typical of high-consumption devices when switching on.
TECHNICAL SPECIFICATIONS
- Operating voltage: 230 V ~, 50 Hz
- Power consumption (stand-by): approx. 0,6 W
- Rated current: max. 16 A
- Rated capacity: max. 3680 W
- Max. switching operations per minute: 10 (depending on the electrical consumer)
- No function when connecting several electrical consumer
- Suitable for circuits with 16 A fuse protection
- Ambient temperature: –10 °C to 50 °C
- Dimensions: 98 x 59 x 41 mm without connector
- IP code: IP20
Dear customer,
to ensure a correct operation of this device, please read these instructions
completely and carefully before use. Please take into consideration that this
manual contains important information on the operation and use of this device.
This instruction manual is part of the device. Please keep this manual in a
safe place for future reference. If you pass the device on to a third person,
please make sure that you also pass on the manual. Damages caused by failure
of following the instructions in the manual will void the warranty. No
liabilities will be taken for consequential damages. This product is certified
according to the applicable directives and complies with statutory
requirements.
DESIGNATED USE
The intended use of the device is the reduction of load peaks from electrical consumers (see technical data) in circuits with a fuse protection of 16 A without any safety-relevant application, during switch-on. Any other use than specified is not permitted!
NOTE: This device left the factory in perfect technical condition. In order to maintain this condition and to ensure safe operation, the user must observe and follow the safety instructions and warning notes in this instruction manual. Any use other than that specified is not permitted!
NOTES ON OPERATION
You need a 230 volt socket to operate your SCL 3680. The user is responsible for compliance with the rules and regulations of the country in which the inrush current limiter is operated. This also applies to the application in which the controller is used.
SAFETY
WARNING: Failure to follow the safety instructions may result in hazards causing damage to property but also serious injury or death.
- Do not touch damaged connecting cables.
- Do not work on the unit or on the connecting cables during a thunderstorm.
- The device may only be used in dry surroundings.
- Do not allow liquids to penetrate the device.
- Check connecting cables and devices regularly for damage and replace them if damaged.
- Repairs may only be carried out by a specialist.
The SCL 3680 is intended for use in a location without direct sunlight and with adequate ventilation. Plug the SCL 3680 into an easily accessible socket. No SCL 3680 devices may be plugged in one after the other. The SCL 3680 device may deal with loads up to the specified capacity limit (see technical data or intended use). Overloading can damage the SCL 3680, which could result in malfunctions or an electrical accident. Devices with a fire hazard must not be operated unsupervised with the SCL 3680 socket. The SCL 3680 device must not be changed, converted, modified or incorrectly repaired. Do not open the SCL 3680 device! Make sure your electrical equipment is turned off when connecting them to the SCL 3680 device.
Do not expose the device to extreme humidity.Inadmissible condensation (condensation of air humidity on the device) can occur if a cold device is brought into a significantly warmer environment. Condensates form, which can lead to short circuits between electrical contacts. In this case, acclimatise the device, which has been disconnected from the mains, for approx. 2 hours at room temperature.
WARNING: Danger of tripping! Tripping can lead to serious injuries.
- Do not obstruct escape routes and stairs.
- Lay the cables so that nobody can step on them or trip over them. All work on the mains and device may only be carried out by authorized electricians.
A qualified person is defined as a person, due to his professional training and experience, has sufficient knowledge in the field of electronics and the relevant health and safety regulations, accident prevention regulations and guidelines, generally has the knowledge of technical regulations (for example, DIN standards, VDE regulations, technical rules, etc.) so that he can assess the safe working condition of electronic devices.
SAFETY INSTRUCTIONS FOR INSTALLATION
The applicable laws and standards of the country in which the device is operated must be followed. The product is not intended to control electrical equipment that has safety-related functions.
Even in normal operation, there is a risk of unexpected malfunction due to a failure or malfunction of the device. The user must ensure that no consequential damage occurs as a result of a malfunction or an undefined switching state.
This product has not been tested for use in safetyrelated applications!
If certain safety requirements apply, they must be implemented by qualified
higher-level measures with approved equipment!
This device may be used by children 8 years of age and over, and by persons
with reduced physical, sensory or mental abilities, or lack of experience and
knowledge, if they have been supervised or instructed in the safe use of the
device and understand the possible hazards. Children are not allowed to play
with the device. Cleaning and maintenance may not be carried out by children
without supervision.
. WARNING AND SAFETY INSTRUCTIONS
Please observe the following safety instructions to avoid malfunctions, damage and health hazards:
- The operation of the device under adverse environmental conditions must be avoided under all circumstances. Adverse environmental conditions are: Ambient temperatures below –10 °C or above 50 °C, combustible gases, solvents, vapors, dust, humidity above 80% rel., Splash or standing water.
- The SCL 3680 may only be operated in dry and closed rooms.
- The inrush current limiter must not be used to operate devices on which a safety function of a machine, system or device is based!
- Above all, devices with a risk of fire must not be operated unattended via the device’s socket
- The device must not be changed, converted, modified or incorrectly repaired.
- If it can be assumed that safe operation is no longer possible, the device must be put out of operation immediately and secured against unintentional operation. Safe operation is no longer guaranteed if the device is no longer functioning, has visible damage, has transport damage and after storage under unfavorable conditions.
- If there are any doubts regarding the application or wiring, it is essential to seek the advice of experts or advice from the manufacturer.
- Maintenance work and repairs may only be carried out by authorized specialist personnel.
- Before commissioning a device, it must generally be checked whether this device or module is suitable for the application for which it is to be used. In case of doubt, it is absolutely necessary to ask advice from experts or the manufacturer.
- Please note that operating and connection errors are beyond our control. Understandably, we cannot accept any liability for any resulting damage.
- In industrial facilities the accident prevention regulations of the Association of Trade Associations for electrical installations and equipment must to be followed.
- In schools, training facilities, hobby and Self-Repair shops it is required, that the operation of devices must be supervised by trained personnel.
- If the device needs to be repaired, only original spare parts may be used! The use of deviating spare parts can lead to serious damage and personal injury!
- Dispose of unnecessary packaging material or store it in a place inaccessible to children. There is danger of suffocation!
COMMISSIONING
Plug the inrush current limiter into a 230 volt socket (see NOTES ON OPERATION). Then insert the mains plug of the switched off electrical consumer into the socket of the SCL3680. The inrush current limiter is ready for operation.
NOTE: The inrush current limiter is suitable for circuits with a fuse protection of 16 A.
HOW IT WORKS
When the electrical consumer is switched on, the inrush current limiter SCL
3680 limits the load peaks typical for powerful devices, so that the circuit
breaker does not trip.
NOTE: The SCL 3680 prevents the circuit breaker from being triggered while the consumer is being switched on. The SCL 3680 cannot permanently reduce the rated current of the inserted consumer – this must not exceed the maximum value of the fuse.
GUARANTEE AND WARRANTY
The dealer/manufacturer from which the device was purchased provides a
guarantee of 2 years from the date of handover for the material and
manufacture of the device.
In the event of a defect, the purchaser is initially only entitled to
supplementary performance. The supplementary performance includes either the
repair or the delivery of a replacement product.
Any devices or parts which have been replaced will become the property of the
dealer/manufacturer. The buyer has to notify the trader of defects
immediately. Proof of the warranty claim shall be furnished by means of a
proper purchase confirmation (purchase receipt, invoice, if applicable).
Damages resulting from improper handling, improper connection, use of parts
from other manufacturers, normal wear and tear, use of force, personal repair
attempts or changes to the device, cables or terminals, change of circuit,
damage due to ignoring the operating instructions, or improper use or other
external influences, if connected to an incorrect voltage or current type,
bridged or incorrect fuses, in case of misuse or damage caused by negligence,
are not covered by the warranty avoid the warranty.
Further claims against the vendor due to this warranty obligation, in
particular claims for compensation for loss of profit, compensation for use
and indirect damages, are excluded, unless legally mandatory.
We reserve the right to repair, rectify, replace or refund the purchase price.
Costs and risks of transport, assembly and disassembly work as well as all
other costs which can be connected with the repair are not replaced. Liability
for consequential damage resulting from faulty function of the device of
whatever nature – is in principle excluded. In the following cases, the
warranty will expire and the device returned at your expense:
- In the case of damage caused by improper handling, operation, storage, as well as by force majeure or other external influences.
- In the case of changes of any kind and repair attempts on the device, cables or clamps. – When non-original components have been used.
- In the case of damage caused by failure to follow the operating instructions and the wiring diagram and in case of damage caused by negligent handling
- n the case of damage caused by overloading the device.
- In the case of damage caused by the intervention of other persons.
- When connected to an incorrect voltage or current type.
- In case of wrong operation or damage caused by negligent treatment.
- For defects caused by bridged fuses or by using incorrect fuses.
- Incorrect connection and/or operation.
- In the case of external forces, damage to the device and/or damage to parts of the device due to mechanical effects or overload.
- When using the device for purposes not described in this manual.
- Unauthorized opening of the appliance.
- Under normal wear and tear.
ENVIRONMENT
Consumers are legally obligated and responsible for the proper disposal of electronic and electrical devices by returning them to collecting sites designated for the recycling of electrical and electronic equipment waste. This device and/or components within the device can be recycled. For more information concerning disposal sites, please contact your local authority or waste management company.
PACKAGING
When disposing of the packaging, please observe the applicable laws on
environmental protection and waste disposal.
The outer packaging can be disposed of using normal household waste disposal.
If you want to dispose of the system components yourself, please observe the
applicable laws on the disposal of electronic waste. Do not leave the
packaging material lying around carelessly. This could become a dangerous
toy for children!
CE-MARK AND CONFORMITY
H-TRONIC GmbH hereby declares
that this device is in compliance with the essential requirements and the
relevant provisions of Directive 2014/53/EU and 2011/65/EU.
The relevant records are in the hands of the manufacturer:
H-TRONIC GmbH, Industriegebiet Dienhof 11, DE-92242 Hirschau
Customer Service
You have any questions, please contact
our technical support: technik@h-tronic.de or
+49 96 22 / 70 200.