SEALEVEL SIO-104 Individually Configurable Serial Interface Card User Manual
- June 13, 2024
- SEALEVEL
Table of Contents
- Introduction
- Before You Get Started
- Software Installation
- Card Setup
- Physical Installation
- Technical Description
- Specifications
- Appendix A – Troubleshooting
- Appendix B – How To Get Assistance
- Appendix C – Electrical Interface
- Appendix D – PC/104
- Appendix E – Silk Screen
- Appendix F – Compliance Notices
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
SIO-104
User Manual | 3501, 3500
Introduction
Overview
The SIO-104 series provides the ultimate serial connection for your PC/104
application. The SIO-104 is available in three different interfaces,
RS-422/485, RS-232, and MIDI.
The RS-422/485 model (P/N 3500) provides an interface capable of long length,
high speed communications.
The RS-232 model (P/N 3501) provides a standard RS-232C interface that is
fully compatible all popular modem software, network operating systems
software, and mouse drivers.
The MIDI model (P/N 3502) provides an interface suitable for control of
musical instruments, MIDI sequencers and other compatible equipment.
Factory Default Settings
The SIO-104 factory default settings are as follows:
Before You Get Started
What’s Included
The SIO-I04 is shipped with the following items. If any of these items are
missing or damaged, contact the supplier.
- SIO-104 Serial Interface Adapter
- (1) DB-9 cable assembly (P/N 3500, 3501), or (1) MIDI cable assembly (P/N 3502)
- (1) Nylon Mounting Hardware Kit
Advisory Conventions
Warning
The highest level of importance used to stress a condition where damage could
result to the product, or the user could suffer serious injury.
Important
The middle level of importance used to highlight information that might not
seem obvious or a situation that could cause the product to fail.
Note
The lowest level of importance used to provide background information,
additional tips, or other non-critical facts that will not affect the use of
the product.
Software Installation
Windows Installation
Do not install the Adapter in the machine until the software has been fully
installed.
Only users running Windows 7 or newer should utilize these instructions for
accessing and installing the appropriate driver via Sea level’s website. If
you are utilizing an operating system prior to Windows 7, please contact
Sealevel by calling 864.843.4343 or emailing
support@sealevel.com to receive access to the
proper driver download and installation instructions.
-
Begin by locating, selecting, and installing the Sea COM Asynchronous Serial Software Suite.
-
Select “Download Now” for Sea COM for Windows.
-
The setup files will automatically detect the operating environment and install the proper components. Follow the information presented on the screens that follow.
-
A screen may appear with text similar to: “The publisher cannot be determined due to the problems below: Authenticode signature not found.” Please click the ‘Yes’ button and proceed with the installation. This declaration simply means that the operating system is not aware of the driver being loaded. It will not cause any harm to your system.
-
During setup, the user may specify installation directories and other preferred configurations. This program also adds entries to the system registry that are necessary for specifying the operating parameters for each driver. An uninstall option is also included
to remove all registry/INI file entries from the system. -
The software is now installed, and you can proceed with the hardware installation.
Other Operating Systems
Refer to the appropriate section of the Serial Utilities Software.
For your reference, record installed SIO-104 settings below:
For additional software support, please call Sea-level Systems’ Technical Support, 864-843-4343. Our technical support is free and available from 8:00 AM – 5:00 PM Eastern Time, Monday through Friday. For email support contact: support@sealevel.com.
Card Setup
The SIO-104 contains several jumper straps for each port which must be set for
proper operation.
Address Selection
The SIO-104 occupies eight consecutive I/O locations. A DIP-switch is used to
set the base address for these locations. Be careful when selecting the base
address as some selections conflict with existing ports. The following table
shows several examples that typically do not cause a conflict. SW1 sets the
I/O address for the SIO-104.
Address | Binary | Switch Position Setting |
---|---|---|
Hex | A9 A0 | 1 |
280-287 | 1010000XXX | Off |
2A0-2A7 | 1010100XXX | Off |
2E8-2EF | 1011101XXX | Off |
2F8-2FF | 1011111XXX | Off |
3E8-3EF | 1111101XXX | Off |
300-307 | 1100000XXX | Off |
328-32F | 1100101XXX | Off |
3F8-3FF | 1111111XXX | Off |
Figure 1 – Address Selection Table
The following illustration shows the correlation between the DIP-switch setting and the address bits used to determine the base address. In the example below, address 300 is selected as a base. Address 300 in binary is XX11 0000 0XXX where X = a non-selectable address bit.
Setting the switch “On” or “Closed” corresponds to a “0” in the address, while
leaving it “Off” or “Open” corresponds to a “1”.
Port Enable / Disable
The port on the SIO-104 can be enabled or disabled with switch position 8 on
the DIP-switch. The port is enabled with the switch “On” or “Closed” and
disabled when “Off” or “Open” (refer to Figure 2). If the port is disabled, be
sure to also disable the interrupt request for that port by removing the IRQ
jumper at header J2.
IRQ Selection
The SIO-104 has an interrupt selection jumper which should be set prior to use
if an interrupt is required by your application software. Consult the user
manual for the application software being used to determine the proper
setting. Position “R” is provided so that a jumper can be installed that
connects a 1K Ohm pulldown resistor to the output of a high-impedance tri-
state driver which carries the IRQ signal. Because the IRQ line is driven low
only by the pull-down resistor, it is possible for two or more boards to share
the same IRQ signal. Position “R” installed is the default setting and should
be left as is unless multiple cards are sharing a single IRQ. If multiple
adapters are sharing a single IRQ, then only one adapter should have the pull-
down resistor (position “R” selected) in the circuit.
The IRQ can be set at jumper J2 for IRQ 2/9, 3-5, 7, 10, 11, 12, or 15. In the
following example, the IRQ is set as IRQ4.
RS-485 Mode (RTS Enable)
J4 selects whether the RS-485 driver is enabled by the UART signal Request To
Send (RTS) or always enabled. With the jumper installed, RTS enables the
RS-485 driver. Removing the jumper enables the driver regardless of RTS. The
jumper should be installed for a 2/4 wire RS-485 application where the SIO-104
is acting as a polled node on a multi-drop network. Remove the jumper if you
are using a point to point RS422 application such as programmable logic
controllers (PLCs), etc.
Physical Installation
Do not install the Adapter in the machine until the software has been fully
installed.
Extreme care should be taken when installing the SIO-104 to avoid causing
damage to the connectors.
After the adapter is installed, connect your I/O cables to J1-J4. Please note
these headers are keyed so that pin 1 of the cable matches pin 1 of the
connector. Refer to Card Setup for information on setting the address and
jumper options before inserting the SIO-104 onto the stack.
- Turn off PC power. Disconnect the power cord.
- Remove the PC case cover (if applicable).
- Gently insert the SIO-104 connector P1 noting proper key orientation of the expansion connector on a PC/104 compatible card. The SIO-104 adapter is keyed per the PC/104 Revision 2.1 Specification. This will aid in preventing the adapter from being inserted incorrectly.
- Mounting hardware (nylon stand-offs and screws) is provided to insure a good mechanical connection. Retain any mounting hardware not used to allow for future expansion.
- The cables provided are keyed and can be installed before or after the adapter is inserted in the stack.
- Replace the cover.
- Connect the power cord. Installation is complete
Technical Description
The SIO-104 series provides the ultimate serial connection for your PC/104
application. The SIO-104 utilizes the 16550 UART. This chip features
programmable baud rate, data format, interrupt control and a 16 Byte input and
output FIFO.
The SIO-104-422 (P/N 3500) is equipped with the RS-422/485 interface allowing
long length, high speed communications suitable for data collection and shop
floor control.
The SIO-104-232 (P/N 3501) provides a standard RS-232C interface that is fully
compatible with the DOS operating system, all popular modem software, network
operating systems software, and mouse drivers.
The SIO-104-MIDI (P/N 3502) allows the controlling of Keyboards, sound
modules, and drum machines which all can be interconnected and driven by
sequencing software. The MIDI specification has been updated recently to
include tape deck control for automated recording and stage & light show
control for real-time theatrical production.
Features
- Selectable interrupts (IRQs) 2/9, 3, 4, 5, 7, 10, 11, 12, 15
- Multiple adapters can share the same IRQ
- 16550 UART standard, 16C650 UART optional
- Uses PC/104 compatible stack through connector for universal mounting
- 5 volt DC operation
Modem Control Signal Considerations
Some software packages require the use of the modem handshake signals such as
CTS or DCD. Refer to your application software manual to determine the
requirements for modem control signals. If no requirements are mentioned, a
safe configuration is to tie DTR to DSR and DCD, and tie RTS to CTS. This
configuration will typically satisfy the modem control signal requirements for
most communications software.
Connector Pin Assignments
RS-232
Signal | Name | DB-9 | Mode |
---|---|---|---|
GND | Ground | 5 | |
TD | Transmit Data | 3 | Output |
RTS | Request To Send | 7 | Output |
DTR | Data Terminal Ready | 4 | Output |
RD | Receive Data | 2 | Input |
CTS | Clear To Send | 8 | Input |
DSR | Data Set Ready | 6 | Input |
CD | Carrier Detect | 1 | Input |
RI | Ring Indicator | 9 | Input |
These assignments meet EIA/TIA/ANSI-574 DTE for DB-9 type connectors.
RS-422/485
Signal | Name | Pin # | Mode |
---|---|---|---|
GND | Ground | 5 | |
TX + | Transmit Data Positive | 4 | Output |
TX- | Transmit Data Negative | 3 | Output |
RTS+ | Request to Send Positive | 6 | Output |
RTS- | Request to Send Negative | 7 | Output |
RX+ | Receive Data Positive | 1 | Input |
RX- | Receive Data Negative | 2 | Input |
CTS+ | Clear to Send Positive | 9 | Input |
CTS- | Clear to Send Negative | 8 | Input |
Please terminate any control signals that are not going to be used. The most
common way to do this is connect RTS to CTS and RI. Also, connect DCD to DTR
and DSR. Terminating these pins, if not used, will help insure you get the
best performance from your adapter.
MIDI
Signal | Name | Pin # | Mode |
---|---|---|---|
MTX + | Transmit Data + | 5 | Output |
MTX- | Transmit Data – | 9 | Output |
GND | Ground | 2,6 | |
MRX+ | Receive Data + | 4 | Input |
MRX- | Receive Data – | 8 | Input |
MIDI Thru + | 3 | Output | |
MIDI Thru – | 7 | Output |
Specifications
Environmental Specifications
Specification | Operating | Storage |
---|---|---|
Temperature Range | 0º to 50º C (32º to 122º F) | -20º to 70º C (-4º to |
158º F)
Humidity Range| 10 to 90% R.H. Non-Condensing| 10 to 90% R.H. Non-
Condensing
Power Consumption
Product | 3500 | 3501 | 3502 |
---|---|---|---|
Supply line | +5 VDC | +5 VDC | +5 VDC |
Rating | 60 mA | 125 mA | 125 mA |
Mean Time Between Failures (MTBF)
Greater than 150,000 hours (Calculated)
Physical Dimensions
The SI0-104 is PC/104 “Compliant” meaning that it conforms to all non-optional
aspects of the PC/104 Specification, including both the mechanical and the
electrical specifications.
Board length | 3.775 inches (9.588 cm) |
---|---|
Board Width | 3.550 inches (9.017 cm) |
Appendix A – Troubleshooting
The adapter should provide years of trouble-free service. However, in the event that device appears to not be functioning incorrectly, the following tips can eliminate most common problems without the need to call Technical Support.
- Identify all I/O adapters currently installed in your system. This includes your on-board serial ports, controller cards, sound cards etc. The I/O addresses used by these adapters, as well as the IRQ (if any) should be identified.
- Configure your Sealevel Systems adapter so that there is no conflict with currently installed adapters. No two adapters can occupy the same I/O address.
- Make sure the Sealevel Systems adapter is using a unique IRQ The IRQ is typically selected via an on-board header block. Refer to the section on Card Setup for help in choosing an I/O address and IRQ.
- Make sure the Sealevel Systems adapter is securely installed in a motherboard slot.
- If you are utilizing an operating system prior to Windows 7, please contact Sealevel‘s Technical support as directed below to receive more information regarding the utility software which will determine if your product is functioning properly.
- Only users running Windows 7 or newer should utilize the diagnostic tool ‘WinSSD’ installed in the SeaCOM folder on the Start Menu during the setup process. First find the ports using the Device Manager, then use ‘WinSSD’ to verify that the ports are functional.
- Always use the Sealevel Systems diagnostic software when troubleshooting a problem. This will help eliminate any software issues and identify any hardware conflicts.
If these steps do not solve your problem, please call Sealevel Systems’
Technical Support, 864-843-4343.
Our technical support is free and available from 8:00 A.M.- 5:00 P.M. Eastern
Time Monday through Friday.
For email support contact support@sealevel.com.
Appendix B – How To Get Assistance
Please refer to Troubleshooting Guide prior to calling Technical Support.
- Begin by reading through the Trouble Shooting Guide in Appendix A. If assistance is still needed, please see below.
- When calling for technical assistance, please have your user manual and current adapter settings. If possible, please have the adapter installed in a computer ready to run diagnostics.
- Sealevel Systems provides an FAQ section on its web site. Please refer to this to answer many common questions. This section can be found at http://www.sealevel.com/faq.asp.
- Sealevel Systems maintains a web page on the Internet. Our home page address is https://www.sealevel.com/. The latest software updates, and newest manuals are available via our web site.
- Technical support is available Monday to Friday from 8:00 A.M. to 5:00 P.M. Eastern Time.
Technical support can be reached at 864-843-4343.
RETURN AUTHORIZATION MUST BE OBTAINED FROM SEALEVEL SYSTEMS BEFORE RETURNED MERCHANDISE WILL BE ACCEPTED. AUTHORIZATION CAN BE OBTAINED BY CALLING SEALEVEL SYSTEMS AND REQUESTING A RETURN MERCHANDISE AUTHORIZATION (RMA) NUMBER.
Appendix C – Electrical Interface
RS-232
Quite possibly the most widely used communication standard is RS-232. This
implementation has been defined and revised several times and is often
referred to as RS-232 or EIA/TIA-232. The IBM PC computer defined the RS-232
port on a 9 pin D sub connector and subsequently the EIA/TIA approved this
implementation as the EIA/TIA-574 standard. This standard is defined as the
9-Position Non-Synchronous Interface between Data Terminal Equipment and Data
Circuit-Terminating Equipment Employing Serial Binary Data Interchange. Both
implementations are in widespread use and will be referred to as RS-232 in
this document. RS-232 is capable of operating at data rates up to 20 Kbps at
distances less than 50 ft. The absolute maximum data rate may vary due to line
conditions and cable lengths. RS-232 often operates at 38.4 Kbps over very
short distances. The voltage levels defined by RS-232 range from -12 to +12
volts. RS232 is a single ended or unbalanced interface, meaning that a single
electrical signal is compared to a common signal (ground) to determine binary
logic states. A voltage of +12 volts (usually +3 to +10 volts) represents a
binary 0 (space) and -12 volts (-3 to -10 volts) denotes a binary 1 (mark).
The RS-232 and the EIA/TIA-574 specification defines two type of interface
circuits, Data Terminal Equipment (DTE) and Data Circuit-Terminating Equipment
(DCE). The Sealevel Systems adapter is a DTE interface.
RS-422
The RS-422 specification defines the electrical characteristics of balanced
voltage digital interface circuits. RS-422 is a differential interface that
defines voltage levels and driver/receiver electrical specifications. On a
differential interface, logic levels are defined by the difference in voltage
between a pair of outputs or inputs. In contrast, a single ended interface,
for example RS-232, defines the logic levels as the difference in voltage
between a single signal and a common ground connection. Differential
interfaces are typically more immune to noise or voltage spikes that may occur
on the communication lines. Differential interfaces also have greater drive
capabilities that allow for longer cable lengths. RS-422 is rated up to 10
Megabits per second and can have cabling 4000 feet long. RS-422 also defines
driver and receiver electrical characteristics that will allow 1 driver and up
to 32 receivers on the line at once. RS-422 signal levels range from 0 to +5
volts. RS-422 does not define a physical connector.
RS-485
RS-485 is backwardly compatible with RS-422; however, it is optimized for
party line or multi-drop applications. The output of the RS-422/485 driver is
capable of being Active (enabled) or Tri-State (disabled). This capability
allows multiple ports to be connected in a multi-drop bus and selectively
polled. RS-485 allows cable lengths up to 4000 feet and data rates up to 10
Megabits per second. The signal levels for RS-485 are the same as those
defined by RS-422. RS-485 has electrical characteristics that allow for 32
drivers and 32 receivers to be connected to one line. This interface is ideal
for multi-drop or network environments. RS-485 tri-state driver (not dual-
state) will allow the electrical presence of the driver to be removed from the
line. Only one driver may be active at a time and the other driver(s) must be
tri-stated. The output modem control signal RTS controls the state of the
driver. Some communication software packages refer to RS-485 as RTS enable or
RTS block mode transfer. RS-485 can be cabled in two ways, two wire and four
wire mode. Two wire mode does not allow for full duplex communication and
requires that data be transferred in only one direction at a time. For half-
duplex operation, the two transmit pins should be connected to the two receive
pins (Tx+ to Rx+ and Tx- to Rx-). Four wire mode allows full duplex data
transfers. RS-485 does not define a connector pin-out or a set of modem
control signals. RS-485 does not define a physical connector.
MIDI
The MIDI (Musical Instrument Digital Interface) specification grew out of the
need for electronic musicians to link together synthesizers, drum machines,
and all manner of other electronic instruments. Until the implementation of
MIDI, each manufacturer of electronic musical equipment had its own
proprietary method of passing data. With MIDI, a universal language for
synthesizer control could be adopted by all manufacturers. MIDI was introduced
in 1983 and very quickly was considered the standard for passing data between
musical instruments. The MIDI specification has been continually updated and
in 1987 was edited to include MIDI Time Code and in 1992 MIDI Machine Control.
The MIDI specification is administered by the MIDI Manufactures Association.
From a hardware standpoint, MIDI is a simple current loop data signal
traveling serially at 31.25K bits per second. MIDI defines the mechanical
connector as a 5 pin DIN connector. There are only two ways to connect the
instruments with cables: MIDI-IN on one instrument to MIDI-OUT on another or
connect the MIDI-THRU to the MIDI-IN. The MIDI-THRU cable “echoes” or
retransmits the data from the MIDI-IN port, thus providing a means of “daisy
chaining” MIDI instruments.
Appendix D – PC/104
What is PC/104?
The PC has become extremely popular in both general purpose (desktop) and
dedicated (embedded) applications. Unfortunately, the PC has been hampered by
the large size required to maintain PC compatibility. PC/104 addresses this by
optimizing the PC bus in a form factor designed for embedded applications.
Briefly, the key differences between PC/104 and the standard “AT” or ISA bus
computer are as follows:
- Reducing the form factor, to 3.550 by 3.775 inches
- Eliminating the need for backplanes or card cages, through its self-stacking bus
- Minimizing component count and power consumption (typically 12 Watts per module) by reducing required bus drive on most signals to 4 mA.
Sealevel Systems has been a member of the PC/104 Consortium since its
inception. Also Sealevel Systems has two members on the working group that is
currently having the PC/104 bus approved by the IEEE as P996.1.
Questions about the PC/104 Consortium can be sent to:
PC/104 Consortium
P. O. Box 4303
Mountain View, CA 94040
415-903-8304 Ph.
415-967-0995 Fax
www.controlled.com/pc104
Appendix E – Silk Screen
Appendix F – Compliance Notices
Federal Communications Commission (FCC) Statement
** This equipment has been tested and found to comply with the limits for
Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference when
the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operation of this equipment in a residential area is likely to cause harmful
interference in such case the user will be required to correct the
interference at the users expense.
EMC Directive Statement**
Products bearing the CE Label fulfill the requirements of the EMC directive
(89/336/EEC) and of the low-voltage directive (73/23/EEC) issued by the
European Commission. To obey these directives, the following European
standards must be met:
- EN55022 Class A – “Limits and methods of measurement of radio interference characteristics of information technology equipment”
- EN55024 – “Information technology equipment Immunity characteristics Limits and methods of measurement”.
This is a Class A Product. In a domestic environment, this product may cause
radio interference in which case the user may be required to take adequate
measures to prevent or correct the interference.
Always use cabling provided with this product if possible. If no cable is
provided or if an alternate cable is required, use high quality shielded
cabling to maintain compliance with FCC/EMC directives.
Warranty
Sealevel’s commitment to providing the best I/O solutions is reflected in the
Lifetime Warranty that is standard on all Sealevel manufactured I/O products.
We are able to offer this warranty due to our control of manufacturing quality
and the historically high reliability of our products in the field. Sealevel
products are designed and manufactured at its Liberty, South Carolina
facility, allowing direct control over product development, production, burn-
in and testing. Sealevel achieved ISO-9001:2015 certification in 2018.
Warranty Policy
Sealevel Systems, Inc. (hereafter “Sealevel”) warrants that the Product shall
conform to and perform in accordance with published technical specifications
and shall be free of defects in materials and workmanship for the warranty
period. In the event of failure, Sealevel will repair or replace the product
at Sealevel’s sole discretion. Failures resulting from misapplication or
misuse of the Product, failure to adhere to any specifications or
instructions, or failure resulting from neglect, abuse, accidents, or acts of
nature
are not covered under this warranty.
Warranty service may be obtained by delivering the Product to Sealevel and
providing proof of purchase.
Customer agrees to ensure the Product or assume the risk of loss or damage in
transit, to prepay shipping charges to Sealevel, and to use the original
shipping container or equivalent. Warranty is valid only for original
purchaser and is not transferable.
This warranty applies to Sealevel manufactured Product. Product purchased
through Sealevel but manufactured by a third party will retain the original
manufacturer’s warranty.
Non-Warranty Repair/Retest
Products returned due to damage or misuse and Products retested with no
problem found are subject to repair/retest charges. A purchase order or credit
card number and authorization must be provided in order to obtain an RMA
(Return Merchandise Authorization) number prior to returning Product.
How to obtain an RMA (Return Merchandise Authorization)
If you need to return a product for warranty or non-warranty repair, you must
first obtain an RMA number.
Please contact Sealevel Systems, Inc. Technical Support for assistance:
Available | Monday – Friday, 8:00AM to 5:00PM EST |
---|---|
Phone | 864-843-4343 |
support@sealevel.com |
Trademarks
Sealevel Systems, Incorporated acknowledges that all trademarks referenced in
this manual are the service mark, trademark, or registered trademark of the
respective company.
© Sealevel Systems, Inc. 3501 Manual
SL9036 12/2022
References
- controlled.com/pc104
- FAQs - Sealevel
- Sealevel - I/O & Computing Products, Engineering and Manufacturing
- SeaCOM Software Overview - Sealevel
- WinSSD Software Utility Overview - Sealevel