KOHLER KG80R 80 kW Emergency Standby Power Generator Steel Instructions
- June 4, 2024
- Kohler
Table of Contents
- KOHLER KG80R 80 kW Emergency Standby Power Generator Steel
- Ratings Range
- Standard Features
- Generator Set Ratings
- Alternator Specifications
- Application Data
- Lubrication
- Cooling
- Operation Requirements
- Controllers
- Sound Enclosure
- Standard Features
- Available Options
- Warranty
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
KOHLER KG80R 80 kW Emergency Standby Power Generator Steel
Ratings Range
Standby: kW 63- 80 kVA 63- 100
Standard Features
- Kohler Co. provides one-source responsibility for the generating system and accessories.
- The generator set and its components are prototype-tested, factory-built, and production-tested.
- The 60 Hz generator set offers a UL 2200 listing.
- CSA approval is available.
- The 60 Hz generator set meets NFPA 110, Level 1, when equipped with the necessary accessories and installed per NFPA standards.
- The generator set accepts rated load in one step.
- A one-year limited warranty covers all generator set systems and components. Two- and five-year extended limited warranties are also available.
- Alternator features:
- The unique Fast-Response X excitation system delivers excellent voltage response and short-circuits capability using a rare-earth, permanent magnet (PM)-excited alternator.
- The brushless, rotating-field alternator has a broad range of reconnecting abilities.
- Other features:
- Kohler APM402 controller. See controller features on page 3..
- The electronic, isochronous governor incorporates an integrated drive-by-wire throttle body actuator delivering precise frequency regulation.
- Quick-ship (QS) models with selected features and a five-year basic limited warranty are available. See your Kohler distributor for details.
Generator Set Ratings
Voltage configuration is not available from the factory. Field- adjustable by an authorized service technician.
RATINGS: All three-phase units are rated at 0.8 power factor. All single- phase units are rated at a 1.0 power factor. Standby Ratings: The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-8528-1 and ISO-3046-1. Obtain technical information bulletin (TIB-101) for rating guidelines, complete rating definitions, and site condition derates. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever. For dual fuel engines, use the natural gas ratings for both the primary and secondary fuels.
Alternator Specifications
- Total harmonic distortion (THD) from no load to full load with a linear load is less than 3.2%.
- NEMA MG1, IEEE, and ANSI standards compliance for temperature rise and motor starting.
- Sustained short-circuit current of up to 300% of the rated current for up to 10 seconds.
- Sustained short-circuit current enabling downstream circuit breakers to trip without collapsing the alternator field.
- Self-ventilated and drip-proof construction.
- Superior voltage waveform from a two-thirds pitch stator and skewed rotor.
- Windings are vacuum-impregnated with epoxy varnish for dependability and long life.
Application Data
Engine
Exhaust
Engine Electrical
Fuel
Lubrication
Cooling
Operation Requirements
Controllers
APM402 Controller
Provides advanced control, system monitoring, and system diagnostics for
optimum performance and compatibility.
- Digital display and menu control provide easy local data access
- Measurements are selectable in metric or English units
- Remote communication thru a PC via network or serial configuration
- The controller supports Modbus protocol
- Integrated hybrid voltage regulator with ±0.5% regulation
- Built-in alternator thermal overload protection
- NFPA 110 Level 1 capability
- Refer to G6-161 for additional controller features and accessories.
Sound Enclosure
-
Sound level (8-point logarithmic average) at 7 m (23 ft.) with full load: 69 dB(A).
-
Sound level compared to competitor ratings with no load: 68 dB(A).*
-
The sound attenuating enclosure uses acoustic insulation that meets UL 94 HF1 flammability classification and repels moisture absorption.
Vertical air inlet and outlet discharge with 90-degree bends to redirect air and reduce noise. -
Internal-mounted critical silencer and flexible exhaust connector.
-
Skid-mounted, steel (standard) or aluminum (optional) construction with hinged doors.
-
Fade-, scratch-, and corrosion-resistant Kohler Cashmere Power Armor textured e-coat paint.
-
Lockable, flush-mounted door latches.
-
Certified to withstand 299 kph (186 mph) wind load rating (aluminum enclosures only).
- Lowest of 8 points was measured around the generator. Sound levels at other points around the generator may be higher depending on installation parameters.
Standard Features
- Air Cleaner Restrictor Indicator
- Alternator Protection
- Battery Rack and Cables
- Electronic, Isochronous Governor
- Gas Fuel System (includes fuel mixer, electronic secondary gas regulator, gas solenoid valve, and flexible fuel line between the engine and the skid-mounted fuel system components)
- Flexible Fuel Line (for fuel supply connection)
- Integral Vibration Isolation
- Local Emergency Stop Switch
- Oil Drain Extension
- Operation and Installation Literature
- Steel Sound Enclosure
Available Options
Approvals and Listings
- CSA Approval
- UL 2200 Listing
Enclosure
- Aluminum Sound Enclosure
- Steel or Aluminum Sound Enclosure (with enclosed critical silencer and three-way catalyst)
Fuel System
- Dual Fuel NG/LPG (automatic changeover)
- Fuel Filter Kit
- Secondary Gas Solenoid Valve (NFPA Fuel System)
Controller
- Four Input/Fifteen Output Module
- Lockable Emergency Stop
- Manual Speed Adjust
- Remote Emergency Stop
- Run Relay
- Remote Annunciator panel
- Two Input/Five Output Module
Cooling System
- Block Heater, 1500 W, 110- 120 V
- Block Heater, 1500 W, 190- 240 V Recommended for ambient temperatures below 10C (50F)
Electrical System
- Battery
- Battery Charger
- Battery Charger Temperature Compensation
- Battery Heater
- Alternator Strip Heater
- Line Circuit Breaker (NEMA1 enclosure)
- Line Circuit Breaker with Shunt Trip (NEMA1 enclosure)
Miscellaneous
- Certified Test Report
- Engine Fluids (oil and coolant) Added
- Rated Power Factor Testing
- Rodent Guards
Literature
- General Maintenance
- Overhaul
- Production
Warranty
- 2-Year Basic Limited Warranty
- 5-Year Basic Limited Warranty
- 5-Year Comprehensive Limited Warranty
Dimensions and Weights
Overall Size, L x W x H, mm (in.) : 3525 x 1154 x 1665 (138.8 x 45.4 x 65.5)
- With steel sound enclosure 1427 (3146)
- With aluminum sound enclosure 1337 (2948)
NOTE: This drawing is provided for reference only and should not be used for planning installation. Contact your local distributor for more detailed information.
DISTRIBUTED BY
2019 Kohler Co. All rights reserved. G4-285 (KG80R) 9/21g
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>