Inter M AOE-212N Audio Over Ethernet User Manual

June 13, 2024
Inter M

Inter M AOE-212N Audio Over Ethernet User Manual
Inter M AOE-212N Audio Over Ethernet

Welcome

A personal welcome to you from the management and employees of Inter-M

All of the co-workers here at Inter-M are dedicated to providing excellent products with inherently good value, and we are delighted you have purchased one of our products.

We sincerely trust this product will provide years of satisfactory service, but if anything is not to your complete satisfaction, we will endeavor to make things right.

Welcome to Inter-M, and thank you for becoming part of our worldwide extended family!


CAUTION

RISK OF ELECTRIC SHOCK DO NOT OPEN

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK. DO NOT REMOVE COVER (OR BACK). NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

WARNING

To prevent fire or shock hazard, do not expose the unit to rain or moisture.

  • WARNING FOR YOUR PROTECTION PLEASE READ THE FOLLOWING-WATER AND MOISTURE: Unit should not be used near water(e.g. near a bathtub, washbowl, kitchen sink, laundry tub, in a wet basement, or near a swimming pool, etc). Care should be taken so than objects do not fall and liquids are not spilled into the enclosure through openings.
  • CLASS 2 WIRING (Adjacent to speaker terminal): The speaker output of this apparatus can exceed 10 Watts and could be a shock injury. Connection to speakers should be performed by a skilled person.
  • Do not install this equipment in a confined space such as a book case or similar unit.
  • This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such vases, shall be placed on the apparatus.
  • This apparatus shall be connected to a mains socket outlet with a protective earthing connection.
  • It has heed to be easy to disconnect the device. To disconnect the device from power, separate AC input cable from inlet or unplug the AC Cord.

CAUTION
*These servicing instructions are for use by qualified service personnel only. To reduce the risk of electric shock, do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so.

NOTE
*This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.


This symbol is intended to alert the user to the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons.

This symbol is intended to alert the user to the presence of important operation and maintenance (servicing) instructions in the literature accompanying the appliance.

Caution: To prevent electric shock do not use this (polarized) plug with an extension cord, receptacle or other outlet unless the blades can be fully inserted to prevent blade exposure.

FOR EACH TYPE USER NOTICE
Class‘A’device (Broadcast device for business purpose) This device is

business purpose (Class‘A’) and seller or user should (Broadcast device for business purpose) be aware of it, and it is to use in other than home.

Unpacking

Although your AOE-212N is neither complicated nor difficult to operate, we recommend you take a few minutes to read this brief manual and familiarize yourself with the important information regarding product features, setup and operation.

As with most electronic devices, we strongly recommend you retain the original packaging. In the unlikely event the product must be returned for servicing, the original packaging (or reasonable equivalent) is required

Installation

Environment
Never place this product in an environment which could alter its performance or reduce its service life. Such environments usually include high levels of heat, dust, moisture, and vibration.

IMPORTANT SAFETY INSTRUCTIONS

  1. Read these instructions.
  2. Keep these instructions.
  3. Heed all warnings.
  4. Follow all instructions.
  5. Do not use this apparatus near water.
  6. Clean only with dry cloth.
  7. Do not block any ventilation openings. Install in accordance with the manufacturer’s instructions.
  8. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
  9. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
  10. Protect the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
  11. Only use attachments/accessories specified by the manufacturer.
  12. Use only with the cart, stand, tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
  13. Unplug this apparatus during lightning storms or when unused for long periods of time.
  14. Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

Features

THE AOE AUDIO OVER ETHERNET NETWORK IS AN EASY TO USE SOLUTION FOR TRANSPORTING AUDIOSIGNALS OVER ETHERNET TCP/IP BASED LOCAL AND WIDE AREA NETWORKS (LAN/WAN), AS WELL AS THE INTERNET.

  • REAL TIME 2 CHANNEL AUDIO SIGNAL TRANSCEIVER (TRANSMITTER/RECEIVER)
    ETHERNET TO 2CHANNEL ANALOG AUDIO SIGNAL REAL TIME TRANSMITTER, RECEIVER.

  • FULL-DUPLEX DATA COMMUNICATION TO ETHERNET NETWORK.
    CONTACT: FUNCTION OF IN/OUT CONTACT DATA TRANSCEIVER (TRANSMITTER/RECEIVER). (EACH OF THE 8 CHANNELS) COMMUNICATION: FUNCTION OF SERIAL DATA TRANSCEIVER (TRANSMITTER/RECEIVER). (RS-232C, RS-422)

  • EXPANSION OF DEVICE
    MULTICAST (1:70) (THIS FUNCTION IS PLANNED TO UPGRADE) UNICAST (1:20) (THIS FUNCTION IS PLANNED TO UPGRADE)

Composition and accessory

  1. AOE-212N main set x1
  2. AC power cord x 1
  3. 3P terminal block x 4
  4. 4P terminal block x 2
  5. 16P terminal block x 2
  6. RS-232C cable x 1
  7. Rack mount screw x 4
  8. Lan cable x 1

Network setting

  • AOE-212N SET can be set to dynamic IP, or static IP.
  • AOE-212N SET use the 5454~5474 port, we need for 5454~5474 port is required for port forwarding or DMZ setting.
  • Used under authorized to provide Internet service providers assign a static IP or dynamic IP in case of WAN network.
  • LAN/WAN use is recommended to use a dedicated network configuration.

Front Panel

Front Panel

  1. MONITOR TERMINAL
    Terminal monitoring the output signal of selected channel by using 3.5  earphone terminal.

  2. MONITOR VOLUME
    Control the monitor output volume.

  3. MONITOR OUTPUT SWITCH
    Switch selecting the desired channel output to monitor.

  4. SIGNAL LED
    LED displaying the input and output audio signals for each channel.

  5. LINK / ACT
    LED displaying the network status and data status of equipment.

  6. LCD
    LCD displaying the network (IP, Mac Address, S/W Version, etc.) settings and server connection status in the set.

  7. DISPLAY SWITCH
    Switch checking out the setting on the display. When the power switch is ON, the indicator will be it.

Display contents are as below.

  1. Inter-M logo + IP Address
    Display Contents

  2. MAC Address + Bandwidth + S/W Version
    Display Contents

  3. Audio state
    Display Contents

  4. Sever on/off state

  5. Sever on, Quantity of Client access device

  6. Client on/off state

  7. Accessed server IP

  8. RS-232 state
    Display Contents

  9. Server on/off state

  10. Client on/off state

  11. PIO state
    Display Contents

  12. Server on/off state

  13. Client on/off state

Power LED
LED displaying the power supply status of set.

Rear Panel

Rear Panel

  1. AC INLET
    Terminal which inputs the AC power.

  2. POWER SWITCH
    Switch turning On/Off the AC Power.

  3. DC INPUT TERMINAL
    Backup battery(24DC) connecting terminal. In case of black out of AC power, connected backup battery supplies the power to the device. DC 24V input supplies the power to the set regardless of switch On/Off.

  4. AUDIO OUTPUT TERMINAL
    It consists of 2-channel with balance outputs (Hot, Cold, GND) with transmitted audio output terminal.

  5. AUDIO INPUT TERMINAL
    It consists of 2-channel with balance outputs (Hot, Cold, GND) with audio output terminal to be transmitted.

  6. AUDIO INPUT VOLUME
    Control the volume of input audio signal. Control level is (-10dB ~ +10dB)

  7. CONTACT POINT INPUT AND OUTPUT TERMINALS
    If contact point signal is inserted in each contact point terminal of transmit AOE-212N device, contact point signal will be transmitted from the contact point output terminal of transmit AOE-212N device.
    Instructions

Input contact point: Contact point signal can be inserted if pin of each channel is short.

Output contact point: Same signals with input signal will be transmitted on the input contact point of transmitter

Caution: Contact point signal is only transmitted when AOE-212N is operated under normal conditions, and please input the signal after checking out the equipment operation status. Because data is transmitted in real times, signal will not be transmitted when device is off.
Contact Point

Example: Connect the device to be controlled to the contact point terminal of AOE-212N from point

‘A’, and insert the control signal from the main building, then device of point ‘A’ can be controlled.

RS-232C/RS-422 communication terminal
Display the signals inserted in RS-232C or RS-422 terminal on the rear of AOE- 212N on the RS-232C and RS-422 terminals of AOE-212N. For example, if signals, ‘A B C D’ are inserted in the transmitter, signals ‘A B C D’ will be displayed on the receiver.
Communication Terminal

RS-232C communication: No. 1 pin (Rx), No. 3 pin (Tx), No. 5 pin (GND)
RS-422 communication: Tx+, Tx-, Rx+, Rx-

  • Transmit and receive data communication using RS-232C/RS-422 ports supports 1:1
  • Example: Connect the device to be controlled to the RS-232/RS-422 terminal of AOE-212 from point ‘A’, and insert the control signal from the main building, then device of point ‘A’ can be controlled.

Network terminal
It is network connecting terminal (RJ-45) and supports 10/100 Base-Tx.

Equipment setting using AOE-212N internal CGI server

It provides the web-page to check the status and control of AOE-212N.

Accessing AOE-212N Web-page

  1. Access to the web-page by using internet browser (Explorer, Chrome, FireFox, etc.)
  2. Insert the IP address displayed on the front LCD of AOE-212N. If it is connected normally, user verification window will pop-up.
  3. User verification is required to access the AOE-212N web-page. Default value for factory setting is as below. User name: admin, password: 1(number).

Please be sure to change the password after the connection you use

Network Setup
Network Setup

Content Default Sample Value
MAC address Display the MAC address the device. 00:1D:1D:NN:NN:NN
Host name Displays the name of device. If it displays the location of device,

management will be convenience. Text only (Incl. digits, no space) is applicable.| aoe-212n
IP address| Setup the IP address of device. There are two ways“: Dynamic IP assignment from DHCP Server” and “Manual Setting”| Manual Setting
IP address| Setting a Static IP address| 192.168.1.99
Subnet Mask| Setting to the Subnet mask.| 255.255.255.0
Gateway| Setup the gateway of network connected to the gateway.| 192.168.1.1
DNS 1 server| Setup the address of DNS1 server.| 168.126.63.1
DNS 2 server| Setup the address of DNS2 server. Follow the setup of propertysetup of device.| 168.126.63.2
Set| Apply and save the changed contents by using the button after changing the setup of SET device.|
Clear| Restore all setups to default values by using  button|

Audio Setup
Audio Setup

Content Default Value
Mode Setup the audio transmission mode. PCM, uni-cast
Audio Client Setup to receive the audio from another AOE-212N.
Port Setup the connecting port value to receive the audio. 5454
IP Address Setup the IP address to receive the server address audio.

192.168.1.99
Buffer rate| The buffer rate is set according to the receiver’s network.| 3%
Run| Check to activate audio receiving.|
Audio sever| Transmitting audio to other AOE-212N.|
Sampling Rate| Set the sample rate of the audio signal.| 44100
**** Channels| INPUT CH 1 is selected; the sender channel 1 is transmitted to the receiver AOE-212N andis outputted on the receiver’s CH1 audio output.INPUT CH 2 is selected; the sender channel 2 is transmitted to the receiver AOE-212N and is outputted on the receiver’s CH2 audio output.ㅍ| **** 1
Port| Setup the connecting port value to transmitthe port audio.| 5454
Sever Address| Set the server address for Multi-cast audiotransmission mode.| 224.124.0.1
Run| Sets‘Run’to begin audio transmission.The equipment list of equipment being sent to theserial communication serial server run-time will be displayed.|
Set| Apply and save the changed contents by using the  button after changing the setup of SET device.|
Clear| Restore all setups to default values by using   button.|

Serial Setup(232)
Serial Setup

Content Default Value
Setting Setup the property of serial communication (RS-232C).
Baud Rate Setup the communication speed of serial port. Scope
is2400bps~115200bps. 9600
Connection Connection setup to transmit the serial communication.
Port Default port value to transmit the serial communication. 5455
IP Address Setup the IP address to receive the serial communication.

192.168.1.99
Run| Setup the Run of serial communication receiving.|
Serial service| Setup to transmit the serial communication to other AOE-212N.|
Run| Sets ‘Run’ to begin serial communications transmission. The equipment list of equipment being sent to the serial communication serial server run- time will be displayed.|
Set| Apply and save the changed contents by using the   button after changing the setup of SET device.|
Clear| Restore all setups to default values by using ****button.|

Serial Setup(422)
Serial Setup

Content Default Value
Setting Setup the property of serial communication (RS-422) port.
Baud rate Setup the communication speed of serial port. Scope
is2400bps~115200bps. 9600
Connection Connection setup to transmit the serial communication.
Port Default port value to transmit the serial communication. 5456
IP address Setup the IP address to receive the serial communication

192.168.1.99
Run| Select ’Run’ to begin serial communication receiving.|
Serial Service| Setup to transmit the serial communication to an otherAOE- 212N.|
Run| Sets ‘Run’ to begin serial communications transmission. The equipment list of equipment being sent to the serial communication serial server run- time will be displayed.|
Set| Apply and save the changed contents by using the  button after changing the setup of SET device.|
Clear| Restore all setups to default values by using  button.|

Data Setup
Data Setup

Content Default Value
Data Client Setup data transmit (Contact point).
Port Set the default data transmit port value. 5457
IP Address Setup the IP address to receive data. 192.168.1.99
Run Set ‘Run’ to activate data receiving.
Data Service Setup to transmit data to other AOE-212N.
Run Sets ‘Run’ to activate the data transmission. A list ofavailable data
transmission equipment being will be displayed.
Set Apply and save the changed contents by using the   button after changing
the setup of SET device.
Clear Restore all setups to default values by using    button.

SASS Setup
SASS Setup

Content Default Value
Enable/Disable Setup to enable/disable SASS. Disable
Server address Server address to update the information of deviceby using
DDNS. None
SASS Port Setup to SASS port. 1665
Audio Port Set the audio transmit port. 5454
Serial(232) port Set the serial (RS-232C) communication transmit port. 5455
Serial(422) port Set the serial (RS-422) communication transmit port. 5456
Data port Set the data transmit the port. 5457
Period for try Time period to access the server. Scope is 1~60 minutes. 5

minutes
Set| Apply and save the changed contents by using the  button after changing the setup of SET device.|
Clear| Restore all setups to default values by using
button.|

Time Setup
Time Setup

Content Default Value
Time Zone Set the time in accordance with GMT. GMT+09:00
Current Time Current time in accordance with set GMT. 1970.01.01
Time Setup Setup the time for AOE-212N.
Manual Setup Setup the time manually by user.
Automatic time synchronization If device is connected to internet, time can
be synchronized automatically by using the time server. Time server address

:Time.bora.net
GMT Change| Change the GMT.|
Set| Apply and save the changed contents by using the ****button after changing the setup of SET device.|

View Log
View Log

Content Default Value
View Log Check the system information such as setup of device and upgrade
information, etc. Recorded information is recorded with time and date.
Delete Log Press the delete log button to erase the log, the log records will
be deleted.

Upgrade System
Upgrade System

Content Default Value

Find File

| Select the file to upgrade the AOE-212N.

Select the file you want if file explorer is opened by pushing the   button next to the text box. Only *.tarfile can be selected.

|
SET| Upgrade the      device after selecting the file

Go to next step if confirm is pushed.
Upgrade System

It will take about 1 minute to upgrade the system. System will restart after upgrading.
Upgrade System

|

Restart System
Restart System

Content Default Value
Restart System Restart the device.
Set Restart the device by using the ****button.

Factory Set System
Factory Set System

Content Default Value
Factory SetSystem Restore the device to factory setting. All information will
be deleted.
Set Restart the device by using the   button.

Password Change
Password Change

Device structure block

Device Structure

How to connect

Device Structure

Applications

Education institute, commercial facility, business facility, religion facility, gym, exhibition room, facility, leisure facility, them park, etc. 1:1 or 1: N functions are flexible to use in any space.

Purpose
How to connect

-1:20 (WAN network) and 1:64 (LAN) purpose (School, resort, theme park, exhibition room, museum, etc.)
Applications

Block Diagram

Block Diagram

Specifications

| AOE-212N
---|---
AUDIO
Maximum Input Level| + 20 dBu
Maximum Output Level| + 20 dBu
Frequency characteristics (48Khz Sampling, ± 1dB)| 30Hz ~ 20kHz
T.H.D (48Khz Sampling)| 0.1% (under)
Support Sampling Frequency| 16, 32, 44.1, 48Khz
Quantization bits| 24 bit
Data communication
Communication type| Contact, RS-232C, RS-422
Contact Input, Output| Input 8-Channel, Output 8-Channel
Serial communication rate| 2400 bps~115200 bps
ETHERNET(LAN)| 10-100 Base-T, (RJ-45)
General characteristics
Operating temperature| –10 ~ 40°C
Using Power| 100-120VAC or 220-240VAC:50/60Hz (Supplied AC mains transformer or DC 24V depends on country requirements)
Power Consumption| 28W under
Weight (SET)| 3.27kg/7.2lb
Dimension (SET)| 482(W)×44(H)×280(D)mm/18.9(W)×1.73(H)×3.14(D)in

  • Specification and performance is subject to be changed without notice.
  • Signal propagation Latency CL2 Switch 1 via to audio : About 1sec/ Data: about 100ms / Contact : about 100ms

Dimensions

Dimensions

Service

Procedures
Take steps to insure the problem is not related to operator error or other products within the system. Information provided in the troubleshooting portion of this manual may help with this process. Once it is certain that the problem is related to the product contact your warranty provider as described in the warranty section of this manual.

Schematic
A Schematic is available by contacting your warranty provider.

Parts List
A Parts List is available by contacting your warranty provider

Variations and Options

Variations
Products supplied through legitimate sources are compatible with local AC power requirements.

Options
No optional items are available for this product.

Warranty

Warranty terms and conditions vary by country and may not be the same for all products. Terms and conditions of warranty for a given product may be determined first by locating the appropriate country which the product was purchased in, then by locating the product type.

To obtain specific warranty information and available service locations contact Inter-M directly or the authorized Inter-M Distributor for your specific country or region.

Inter-M, Ltd. (Korea) began operations in 1983.

Since then, Inter-M has grown to become one of the largest manufacturers of professional audio and commercial sound electronics equipment in the world.

Inter-M has gained worldwide recognition for its own branded products, as well as private label manufacturing of electronics sold under other names (OEM).

The company is no longer just a Korean company, but rather a global company that is truly international in scope, with factories and offices in Korea and China, and sales and marketing operations located in Japan, Europe, and the U.S.A.

With more than 850 employees around the globe,
Inter-M is well-poised for further growth and expansion.

Inter-M Americas, INC.
13875 ARTESIA BLVD. CERRITOS, CA 90703 USA
TEL : +1-562-921-0313, FAX : +1-562-921-0370
Home Page : http://www.inter-m.net, E-mail : [email protected]

Inter-M Corporation
SEOUL OFFICE:653-5 BANGHAK-DONG, DOBONG-GU, SEOUL, KOREA
TEL : +82-2-2289-8140~8, FAX : +82-2-2289-8149
Home Page : http://www.inter-m.com, E-mail : [email protected]

MADE IMAN KOREA
June 2013 132449

Inter M Logo

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Inter M User Manuals

Related Manuals