TID-B Digital Thermometer User Manual
- June 13, 2024
- TID
Table of Contents
www.jbctools.com
INSTRUCTION MANUAL TID
Digital Thermometer
This manual corresponds to the following reference:
TID-B
Packing List
The following items are included:
Features and Connections
TID Digital Thermometer comes with a handy case. The case is designed to be
used with TID inside.
There is no need to take the console and the sensor out to work with, but it
is possible if desired.
LCD Display
Operating Buttons
On / Off Button
One-click: Switch on the device or Activate / deactivate lighting
Long press: Switch off the device
Up / Down Buttons
One-click: Display of the min/max value
Long press: Reset the min/max value of the current measure-ment
Both simultaneously: Rotate display, overhead display
Function Button
One-click: Hold measurement function
Long press, 2s: Open configuration menu (ONF appears in the display)
Configuration Menu
Press the button for 2 seconds to open the configuration menu, when “ConF” appears in the display release the menu button. Use buttons to change between the different values.
Parameter | Description | Details |
---|---|---|
PoFF | Shut-off time | No automatic shut-off; indicated by “oFF”. |
Automatic shut-off after a selected time in hours:minutes, during which no
buttons have been pressed. For example 1:15 (1 hour, 15 minutes).
LitE| Backlight| Backlight deactivated; indicated by “oFF”.
Automatic shut-off of the backlight after a selected time in minutes:seconds,
during which no buttons have been pressed. For example 0:30 (0 minutes, 30
seconds).
No automatic shut off of the backlight; enter value “on”.
Unit| Display unit| Temperature display in °C; enter value “ºC”.
Temperature display in °F; enter value “ºF”.
Init| Factory settings| Use current configuration; enter value “no”.
Reset device to factory settings; enter value “YES”.
After confirming with the menu button, the display shows: “Init donE”.
Operation
Solder Aplication
The soldering tip must be properly tinned before taking a measurement.
Measure Tip Temperature Place the soldering tip in the centre of the
sensor as when soldering. Wait until the temperature measurement stabilizes.
Battery
Battery Indicator
If emty battery blinks in the display, the batteries must be replaced.
However, the device will still operate for a certain length of time.
If the BAT display text appears in the main display, the battery voltage is no
longer adequate for device operation. The battery has to be cahnged to use the
device.
Changing Battery
Unscrews the Phillips screws (1) and remove the cover.
Replace the two AA batteries (2). Ensure that the polarity is correct. It must
be possible to insert the batteries in the correct position without using
force.
The O-ring (3) must be undamaged, clean and positioned at the intended depth.
Fit the cover (4) on evenly. The O-ring must remain at the intended depth!
Tighten the Phillips screws (1).
Note: If TID is not used for an extended period of time, the batteries
must be removed. This will prevent the batteries from leaking.
Changing the Sensor
Replacement To replace the STD sensor, pull it vertically out of the sensor stand and replace it with a new one.
Error Messages
Display | Meaning | Possible Causes | Remedy |
---|---|---|---|
bAt | Battery empty. | Battery empty. | Replace battery. |
Err.1 | Measuring range exceeded. | Measurement too high. | Stay within allowable |
measurement range.
Incorrect measuring probe connected.| Check TC type.
Measuring probe or device defect.| Contact with technical service.
Err.2| Measuring range is undercut.| Measurement too low.| Stay within
allowable measurement range.
Incorrect measuring probe connected.| Check TC type.
Measuring probe or device defect.| Contact with technical service.
SYS Err| System error.| Error in the device.| Switch device on/off.
Replace batteries and restart the device.
Note:
If problem is not solved, contact with JBC’s Technical Support at:
www.jbctools.com/contact-us
Maintanance
– Before carrying out maintenance or storage, always allow the equipment to
cool down.
– Check periodically that the sensor is clean.
– Use a damp cloth when cleaning. Alcohol can only be used to clean the metal
parts.
– Unnecessary unscrewing endangers the protection against moisture and should
therefore be avoided.
– Replace any defective or damaged parts. Use original JBC spare parts only.
– Repairs should only be performed by a JBC authorized technical service.
Batteries
– If the device ist not used for a longer periode of time, the batteries must
be removed to avoid leaks of the batteries.
– If the batteries have different charge levels, they may leak and damage the
device.
– Do not use different types of batteries.
– Only use high-quality and suitable alkaline batteries.
– Remove depleted batteries immediately and dispose of them at a suitable
collection
– Using damaged or unsuitable batteries can generate heat, which can cause the
batteries to crack and possibly explode. **** Danger of explosion!
Safety
** It is imperative to follow safety guidelines to prevent electric shock,
injury, fire or explosion.
This device has been designed and tested in accordance with the safety
regulations for electronic devices.
However, its trouble-free operation and reliability cannot be guaranteed
unless the standard safety measures and special safety advice in this manual
is complied with during use.
– Trouble-free operation and reliability of the device can only be guaranteed
if it is not subjected to any other climatic conditions than those stated
under “Specification”.
If the device is transported from a cold to a warm environment, condensation
may result in failure. Should this occur, make sure the temperature of the
device has readjusted to the ambient temperature before trying a new start-up.
– If the digital thermometer is connected to other devices, the circuitry must
be carefully designed.
Internal connection to other apparatus (e.g. connection GND/earth) may result
in high voltages which will damage the device(s).
– If there is any risk during use, the device must be switched off immediately
and marked accordingly to avoid being used again.
– Operator safety may be at risk if there is visible damage to the device, the
device is not working as specified or the device has been stored under
unsuitable conditions for a long time.
If in doubt, please return the device to the manufacturer for repair or
maintenance.
– For professional use. Only used by authorised personnel.
Warning
– Do not use this product as a safety or emergency stop device, or in any
other application where failure of the product could result in personal injury
or material damage.
– Do not use the units for any purpose other than measuring cartridge tip
temperature.
Working recommendations**
– Use a “non residue” classified flux and avoid contact with skin or eyes to
prevent irritation.
– Be careful with the remains of liquid tin. In contact with skin, it can
cause burns.
– Be careful with the fumes produced when melting soldering.
– Keep your workplace clean and tidy. Wear appropriate protection glasses and
gloves when working to avoid personal harm.
Specifications
TID
Digital Thermometer
Ref. TID-B
– Measuring
– Measuring Range:
– Accuracy:
– Cold Junction Compensation:
– Temperature Drift:
– Measuring Frequency:
– Probe Connection:
– Operating Conditions:
– Storage Temperature:| -65 to +1200 °C / -85 to +2192 °F
±0.1 % of measuring value ±0.1 % full scale
±0.3 °C
±0.01 % of measuring value/K
±0.025 ºC/K
3 measurings per second
Thermocouple Type K
-25 to 50 °C / -13 to 122 ºF
0 to 80 %RH (non-condensing)
-25 to 70 °C / -13 to 158 ºF
---|---
– Power Supply
– Batteries:
– Power Requirements:
– Battery Life:
– Battery Indicator:
– Console Dimensions / Weight: (L x W x H)
– Total Net Weight:
– Package Dimensions / Weight: (L x W x H)| 2x AA
approx. 1mA, approx. 3mA with backlight Service life > 2500h with alkaline
batteries (without backlight)
4-stage battery status indicator
Repalcement idicator “BAT”
125 g / 0.28 lb (incl. batteries)
108 x 54 x 28 mm / 4.25 x 2.13 x 1.10 in
766 g / 1.69 lb
1276 g / 2.81 lb
280 x 280 x 164 mm / 11.02 x 11.02 x 6.46 in
Warranty
JBC’s 2 year warranty covers this equipment against all manufacturing defects,
including the replacement of defective parts and labour.
Warranty does not cover product wear or misuse. In order for the warranty to
be valid, equipment must be returned, postage paid, to the dealer where it was
purchased.
Get 1 extra year JBC warranty by registering here:
https://www.jbctools.com/productregistration/ within 30 days of purchase.
This product should not be thrown in the garbage.
In accordance with the European directive 2012/19/EU, electronic equipment at
the end of its life must be collected and returned to an authorized recycling
facility.
www.jbctools.com
0028993-090223
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>