ADLER CR 7747 Bathroom Heater User Manual
- June 13, 2024
- ADLER
Table of Contents
ADLER CR 7747 Bathroom Heater
Product Information
-
Model Identifier
- CR 7747 Mode l: AD7747
-
Heat Output
- Nominal Heat Output : 2.0 kW
- Minimum Heat Output (indicative ): 1.4 kW
- Maximum Continuous Heat Output: 2.0 kW
-
Auxiliary Electricity Consumption
- At Nominal Heat Outpu t: 0.000 kW
- At Minimum Heat Output : 0.000 kW
- In Standby Mode: 0.000 kW
- Contact Information : Adler Sp. z o.o. ul. Ordona 2A, 01-237 Warszawa, Polska
Product Usage Instructions
- Type of Heat Output/Room Temperature Control
- Select one of the following options
- Single Stage Heat Output and No Room Temperature Control
- Two or More Manual Stages, No Room Temperature Control
- With Mechanic Thermostat Room Temperature Control
- With Electronic Room Temperature Control
- Electronic Room Temperature Control Plus Day Timer
- Electronic Room Temperature Control Plus Week Timer
- Other Control Options
- Multiple selections are possible
- Room Temperature Control with Presence Detection (No)
- Room Temperature Control with Open Window Detection (Yes)
- With Distance Control Option (No)
- With Adaptive Start Control (No) – With Working Time Limitation (Yes)
- With Black Bulb Sensor (No)
Note: The product should not be covered with clothes, blankets, or other textile items that may cause ignition. For any further assistance, please contact Adler Sp. z o.o. at the provided contact address.
READ CAREFULLY AND KEEP FOR FUTURE REFERENCE
-
Before using the device, read the user manual and follow the instructions contained therein. The manufacturer is not liable for damage caused by using the device contrary to its intended use or improper operation.
-
The device is for home use only. Do not use it for other purposes that are inconsistent with its intended use.
-
The device should only be connected to a 220-240V ~50/60Hz socket.
In order to increase the safety of use, many electrical devices should not be connected to one power circuit at the same time. -
Be especially careful when using the device when children are around. Do not allow children to play with the device and do not allow children or people unfamiliar with the device to use it.
-
WARNING: This equipment can be used by children over 8 years of age and persons with reduced physical, sensory or mental abilities, or persons without experience or knowledge of the equipment, if it is carried out under the supervision of a person responsible for their safety or they have been given instructions on the safe use of the device and are aware of the dangers associated with its use. Children should not play with the equipment. Cleaning and user maintenance should not be performed by children, unless they are over 8 years of age and are supervised.
-
WARNING: The appliance is designed to dry fabrics washed in water only.
-
WARNING: If the appliance is used in a bathroom, it should be located so that switches and other controls cannot be touched by persons in the bath or shower.
-
WARNING: To avoid hazards to very young children, this appliance should be installed so that its lowest part is at least 600mm above the floor.
-
WARNING: To avoid overheating, do not cover the device.
-
Always remove the plug from the socket after use by holding the socket with your hand. DO NOT pull on the net cord.
-
Do not immerse the cord, plug or the entire appliance in water or any other liquid. Do not expose the device to weather conditions (rain, sun, etc.)
-
Periodically check the condition of the power cord. If the power cord is damaged, it should be replaced by a specialist repair facility in order to avoid a hazard.
-
Do not use the appliance with a damaged power cord, or if it has been dropped or damaged in any way, or is not working properly. Do not repair the device yourself, as it may cause electric shock. Return the damaged device to the appropriate service center for inspection or repair. Any repairs may only be made by authorized service points. Improperly performed repair may result in serious danger to the user.
-
Do not use the device near flammable materials.
-
Do not leave the device connected to the socket unattended.
-
For additional protection, it is advisable to install a residual current device (RCD) in the electrical circuit with a rated residual current not exceeding 30 mA. Please consult an electrician for this.
-
When the appliance is used in the bathroom, remove the plug from the mains socket after use, as the proximity of water is dangerous even when the appliance is switched off.
-
Do not allow the device to get wet. If the device falls into water, pull the plug out of the socket immediately. Do not put your hands into the water when the device is connected to the mains. It must be checked by a qualified electrician before being used again.
-
Do not handle the device with wet hands.
-
Always switch off the appliance before removing the plug from the socket.
-
The operating device must be supervised and within sight at all times. When leaving the room where the device is operating, always turn it off. If the device is not working, always remove the plug from the mains socket.
-
Do not connect the device to an automatic de-energizing device, such as a thermal control device or a timer.
-
Keep flammable materials such as furniture, bedding, paper, clothes, curtains, etc. at least one meter away from the device.
-
Do not cover the device during operation or place any objects on it.
-
The power cord must not be laid above or below the heater, nor should it touch or lie near its hot surfaces. Do not place the device under an electrical outlet.
-
Heating surfaces may heat up to more than 60°C. The device should be installed in such a place that children and pets cannot reach it.
-
The device may not be installed or used in vehicles.
-
There are parts inside the appliance that may be hot or cause sparks. Do not operate the heater in areas where materials such as gasoline, paint or other flammable substances are used or stored.
-
Always disconnect the device from the mains and disconnect the power cord from the device when it is not in use or you want to clean it.
BEFORE FIRST USE
- After removing the packaging, make sure that the device is in good condition.
- The packaging materials may contain plastic, nails etc., which may be hazardous and therefore should not be left within the reach of children.
- Keep all objects at least 1 meter from the front and sides of the appliance.
- Do not use the device in next to a window as rain may cause the electric shock.
- Do not use the device outdoors, or on wet surfaces. Avoid spilling liquid on the device.
WALL INSTALLATION METHOD
- Installation MUST be carried out by a qualified electrician.
- Do not connect the device to the mains source until it has been installed in its final location and adjusted to the position it will be used in.
- Avoid installation behind a door.
- The device must not be located immediately below a socket-outlet.
- In order to avoid a hazard due to inadvertent resetting of the thermal cutout, this device must not be supplied through an external switching device, such as a timer, or connected to a circuit that is regularly switched on and off by the utility.
- On the wall at least 1.8 meters away from the ground, make two holes horizontally with a hole distance of about 176mm. Two metal screws and two plastic expansion screws are attached in box together with the device.
- Install expansion screws in the holes to keep the nail heads slightly up and project at least 4mm from the wall.
- Place the device with the air outlet vent facing downwards, align the nail head with the two holes on the back of the fuselage, hang it on the screw, and move the device appropriately so that the wall-hanging hole of the product catches the nail so as to install it firmly.
- After the installation is completed, check the montage stability first, and then turn on the power after it is completely stable.
- Before use, make sure that the towel rack fixing nut (4) is tightened.
- Rotate the towel rack (3) down or up according to your needs.
- Before use, make sure the device is well fixed on the wall.
WARNING
- Do not cover or restrict airflow to the inlet or exhaust grilles in any manner as the device may overheat and become a fire risk.
- FIRE RISK EXISTS IF THE HEATER IS COVERED BY OR POSITIONED CLOSE TO CURTAINS OR OTHER COMBUTIBLE MATERIALS.
PRODUCT DESCRIPTION: Bathroom heater CR7747 – Figure I and II.
- Main power switch
- Housing
- Rack for towel
- Towel rack fixing nut
- Screen display
- Air outlet
- Air inlet
Control panel description – Figure III. T – digital display
- R – timer icon
- F2 – hot air fan icon
- Fan button
- C – Setting button “SET”
- F – temperature / time increase button “+”
- J – desired working day button for days “d1-d7” L – time switching on button “TIME/on”
- M – edit button for period P1-P6
Remote control (4) description – Figure IV. A – working status button
Time button
- E – temperature / time decrease button “-“ G – desired setting confirmation button “OK” K – weekly program button “P”
- N – time turning off button “TIME/off”
- O – open-window detection mode button
- K1 – weekly program icon “P”
- F1 – warm air fan icon
- O1 – open-window detection mode icon 9 – Timer button
USAGE
USAGE WITHOUT REMOTE CONTROL
STANDBY STATE – figure V
Plug in the power and turn on the main power switch (1) on the back of the
device. The device enters the standby state. The display shows “S” – look at
figure V.
FAN OPERATION – figure: VI, VII, VIII. Press the fan button (8) on the device
– once, the device flows cool air – the display looks like figure VI. – twice,
the device flows warm air – the display looks like figure VII.
– three times, the device flows hot air – the display looks like figure VIII.
– four times, the device enters the standby state. Before switch off the
device is blowing cold air for 30 seconds – the display looks like figure VI.
TIMER OPERATION – figure: IX, X.
DELAYED STOP – figure IX.
Press the button (9) to set timer in range from 1 – 12 hours. Pressing the
button (9) one time increases one hour for timer. After setting time by
repeated pressing the button (9) to desired time period, the display will show
current setting time for 5 seconds, then resume to previous display, meanwhile
the timer icon (R.) starts to be illuminated. After desired time pass, the
device will switch off automatically. Figure IX. is an example of setting 8
hours.
DELAYED START – figure X.
In standby mode, press the timer button (9), you can set the turn-on time in
range from 1 to 12 hours. After setting time by repeated pressing the button
(9), the display (5) shows the turn-on time and also the (R.) icon is
illuminated. The display (5) automatically decreases 1 hour for each hour
passed. When the power-on time arrived, the device will automatically turns
on. The default setting temperature is 23 degree of Celsius during turn-on.
Figure X. is an example to set turn-on time to 8 hours.
TEMPERATURE SETTING
There is no available temperature setting function if no use the remote
control (4). The device will automatically turn off after 12 hours of
continuous operation and enter into standby mode.
USAGE WITH REMOTE CONTROL
FUNCTIONS OPERATE BY REMOTE CONTROL DESRIBED BELOW CANNOT BE SET UP WITHOUT USING THE REMOTE CONTROL
Note: During the operation of the remote control (4), the remote control transmitter must aim at remote control receiving area of device to avoid remote control ineffective. The remote controller (4) can be normally used within 3 meters in front of the product and in the left and right angles of 60 degrees.
FAN OPERATION – figure: VI, VII, VIII.
Press the button (A) once, the device enters into working status, the device
flows cool air – the display looks like figure VI. Press the fan button (8)
- again, the device flows the warm air – the display looks like figure VII.
- again, the device flows the hot air – the display looks like figure VIII.
- again, the device enters into working status, the device flows cool air – the display looks like figure VI.
Pressing the button (A) again cause the cool air starts to blow, the display looks like figure V. After 30 seconds the device stops to blow, the device enters into standby mode again.
TIMER OPERATION – figure: IX, X.
To operate timer function with remote control use the button (9). The
operation is same as for buttons at device housing described in point 1.3.
CURRENT TIME / DAY SETTING – figure: XIII, XIV, XV.
It is obligatory to set up inside clock of the device by setting up the
current hour and minutes and actual day od week, just to let the device
operate properly with weekly program.
Weekly program can be set up by using the remote control ONLY.
NOTE: after the device is power off (plug off) or brake in electricity
supplying happened, the device will reset, it is necessary to set the current
time and day again because the device is not equipped in inside battery to
support the memory of inside device clock.
The current time (hour and minutes) and day of week can be set up both under
standby mode and working status. Follow up next steps
CURRENT TIME SETTING
Press SET button (C.) on the remote control (4)
- one time, the digital display (T) shows ”12“ that means 12:00 a.m. as default, then press the plus (F) or the minus (E) buttons repeatedly to set current hour in range from 00 to 23 according to local time
- press SET button (C.) button again, the display shows minutes “ 30“ that means half an hour as default, then press the plus (F) or the minus (E) buttons repeatedly to set current minutes in range from 00 to 59. Continuous the setting procedure described in point 2.3.2 now.
CURRENT DAY SETTING
Just after complete current time setting (point 2.3.1) continue to set up the
day setting, as below steps
- press SET button (C) on the remote control (4) again to display the day of week,
- then press the plus (F) or the minus (E) buttons repeatedly to set current day.
- The digital display (T) will show : d1=Monday, d2=Tuesday, d3=Wednesday, d4=Thursday ,d5=Friday, d6=Saturday, d7=Sunday.
- then press “OK” confirm button (G) to confirm the setting.
Example: setting to Wednesday, 9:30 a.m. – look at Figures: XIII, XIV, XV.
NOTE
- After the device is power off (plug off) or brake in electricity supplying happened, the device will reset, it is necessary to set the current time and day again.
- In such case, press SET button (C) to check the current time & day in turn;
- The timer set up period is 00-23 for hours, 00-59 for minutes. To check the current time and setting temperature, press SET again.
TEMPERATURE SETTING – figure XVI.
During working status, press the plus (F) or the minus (E) buttons, the digital display (T) shows ”23“ that means default temperature 23 degree of Celsius. Then, then press the plus (F) or the minus (E) buttons repeatedly to set desired temperature in range from 10 to 49 degree of Celsius, press confirmation button (G) to confirm the setting.
For example :The current ambient temperature is 15 degree of Celsius, when set temperature to 25 degree of Celsius, the digital display (T )will show like at Figure XVI.
Principle of temperature control by the device
- when the difference between desired temperature and the current room temperature is higher than 2 degree of Celsius, the device working with hot airflow, the icon (F2) is illuminated,
- when the difference between desired temperature and the current room temperature is lower than 2 degree of Celsius, the device working with warm airflow, the icon (F1) is illuminated,
- when desired temperature and the current room temperature are the same, the device blowing the cool airflow for 30 seconds to blow out warm air left inside, then the device will stop operate.
If you want to cancel the setting temperature, press the fan button (8) to choose the low or high heating level, the device will work without
setting temperature, so the digital display (T) will show “–”. After continuous heating for 12 hours, the fan will blow cool air fpr 30 seconds, then the device stops blowing and will enter into standby mode.
SETTING THE WEEKLY PROGRAM
- available by the remote control (4) only. FigureS: XVII – XXI.
NOTE: Before turn on weekly program: it must set days of work and work
time period (P1-P6) , otherwise the weekly default state is “00”, the product
does not work.
After complete setting of current TIME / DAY (points 2.3.1 and 2.3.2) , below
are listed steps to set weekly program
Press button (A) on remote control, the product enter into working
status.
Press the weekly program button (K) , the display (5) shows icon K1, the
device enters into weekly program setting. Look at figure XVII.
Press day button (J) , the digital display (T) shows “d1” , then press repeatedly the day button (J) to set desired working day (Monday-Sunday: d1~d7). Look at figure XVIII to see the example setting for Monday.
Press the edit button (M), the display (5) shows “P1”- period one – as default, press the edit button (M) to set time period (P1-P6).
Note: It can be set maximum 6 time periods for each working day, while
setting any time and adjust temperature.
Follow step 2.5.5 – 2.5.7 below to set : turn-on time / turn-off time /
desired temperature for each time period (P1-P6). Setting P1 shown at figure
XIX.
Press the time on button (L), the digital display (T) shows “00” by default.
Press the timer on button (L) once in increments of one hour as many times as
necessary to set the desired on time (00-24 hours). Example: set the on time
to 7:00 am – see picture XX. 2.5.6. Press time-off button (N) to set up the
stop of time period, the digital display (T) shows the previous turn-on time
by default. Press time-off button (N), each one time pressing increases one
hour to set the turn-off time in range: 00-24 hours.
Example: setting the turn-off time 13:00 p.m. – look at figure XXI.
The desired time switch off hour cannot be earlier than desired time-on hour.
When the desired time-on (start of period) is the same as the desired time
- off (stop of period), the device enters into standby mode. 2.5.7. Press the plus (F) or the minus (E) buttons repeatedly to setting the desired temperature in range from 10 to 49 degree of Celsius. 2.5.8. Repeat steps 2.5.3 – 2.5.7 described above to set the weekly program for all device working day you want.
Then press the confirmation button (G) to confirm the settings.
To cancel the weekly program function, press the button (K) again , the icon
(K1) will go off. The weekly program is off.
Note: After the above setting are completed and weekly program is working, the icon K1 is illuminated on the display (5), then
- press the day button (J) to check with set working day (d1-d7),
- press the edit button (M) to check with time period (P1-P6),
- press the time-on button (L) to check with the set turn-on time,
- press the time-off button (N) to check the set turn-off time.
OPEN WINDOW DETECTION MODE SETTING
- available by the remote control (4) only.
Press the button (A) on your remote control (4),the device enters into working
status. Let the device heating for a moment until operate stable.
Press the button (O) by remote control, the icon (O1) will be on display (5).
The temperature display “23”by default. Press the plus (F) or the minus (E)
buttons repeatedly to set target temperature. During open-window detection
mode, once the ambient temperature drops 5-10 degree of Celsius within 10
minutes, then the device will stop working and enter into standby mode. Then
press the button (A) to turn on the device.
Press the button (O) again to turn off the open-window detection mode, the
icon (O1) will off at display (5) and the device will resume to previous
working mode.
Below is an example to set 23 degree of Celsius during open-window detection
mode. Look at figure XI.
When turn on at the same time for both open-window detection and weekly
program, during the OFF period of weekly program, the device does not operate.
During the working status of weekly program, the temperature is subject to the
setting temperature of open-window detection mode. Look at figure XII.
REMOTE CONTROL
Follow the instructions of use and the recycle rules given on the battery
packaging. The procedure of battery replacement is described below – look at
figure XXII.
- Open the battery compartment by sliding the cover down.
- Insert the battery into the compartment. The remote control requires 1 CR2025 3V lithium battery (not included).
- Close the battery compartment.
CLEARING AND MAINTENANCE
- Before cleaning switch off the main power switch (1), plug out the device and let the device to cool down.
- A common cause of overheating is deposits of dust or fluff in the appliance. Ensure these deposits are removed regularly by unplugging the device and vacuum-cleaning air inlets (7) and air outlets (6), where available.
- Do not use abrasive cleaning products on this device. Clean with a damp cloth (not wet) rinsed in hot soapy water only.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>