IMPORTANT NOTE:
Please read this manual carefully before installing or operating your air
conditioning unit. Make sure to save this manual for future reference.
CAUTION:
The system is charged with fl ammable refrigerant, safety checks are necessary
to ensure that the risk of ignition is minimised.
That ’s better. That ’s Actron.
This manual is a controlled document which contains confidential and
proprietary information.
Distribution, modification, copying and/or reproduction are prohibited without
written consent from ActronAir Product design and specifications are subject to
change without prior notice for product improvement.
Drawings are for illustration purposes only and may vary depending on the
model purchased.
READ SAFETY PRECAUTIONS
Incorrect system operations due to ignoring instructions can cause serious
damage or injury. The seriousness of potential damage or injuries is classified
as either a WARNING or CAUTION.
CAUTION: Failure to observe a caution may result in injury or equipment
damage.
WARNING: Failure to observe a warning may result in death or serious
injury.
General Information
CONGRATULATIONS on your purchase of an ActronAir air conditioning unit! This
unit has been designed and engineered to provide optimum air conditioning and
to achieve maximum energy efficiency.
Your air conditioning system has been manufactured from the highest quality
materials. Numerous “in house” and “external” inspections and test procedures
were conducted to your air conditioning unit to ensure satisfactory operation.
This guide provides operation instructions specific to your split indoor unit.
Read this manual thoroughly to ensure safe operation of your air conditioning
system.
Safety Instructions
- Only licensed HVAC technicians* should service this air conditioning equipment. Improper service or alteration by an unqualified technician could result in significant and major damage to the product or property which may render your warranty null and void. Such unqualified service could also lead to severe physical injury or death. Follow all safety instructions in this literature and all warning labels that are attached to the equipment.
- Prevailing WH&S regulations must be observed and will take precedence to the safety instructions contained on this manual. Safe work practices and environment must be the paramount importance in the performance of all the service procedures.
- This appliance is not intended for use by young children or infirm persons unless they have been adequately supervised by a responsible person to ensure that they can use the appliance safely. Young children should be supervised to ensure that they do not play with the appliance.
*Qualifications required will be appropriate Electrical, Refrigeration and Refrigerant Handling License and Training dependent on local State/Territory regulations.
DANGER
Hazardous Voltage – Risk of Electrocution.
Turn Off the power from main isolator before proceeding with any service and
maintenance work of the unit. Observe proper LOCK-OUT/TAG-OUT (LOTO)
procedures for electrical appliances in order to prevent accidental switching-
on of the power supply. Extreme care and caution must be observed should there
be a need to work on live circuit.
WARNING
- If any abnormal situation arises (like burning smell), turn of the power supply and call your HVAC technician for instructions to avoid electric shock, fire or injury.
- DO NOT let the indoor unit or the controller get wet. It may cause electric shock or fire.
- DO NOT insert fingers, rods or other objects into the air inlet or outlet. This may cause injury, since the fan may be rotating at high speeds.
- DO NOT use a flammable spray such as hair spray, lacquer or paint near the unit. This may cause fire or combustion.
PRODUCT INSPECTIONS
- Fully check your air conditioning unit and all items against the bill of loading upon receiving your shipment. Inspect the unit, components and accessories for any sign of shipping damage. If there is any damage to the unit, contact ActronAir Customer Care immediately on: 1300 522 722.
- Check the unit nameplate to verify the model, serial number, electrical rated specifications and details are correct.
CODES, REGULATIONS AND STANDARDS
- The installer assumes responsibility to ensure that unit installation complies with the relevant council, state & federal codes, regulations and building code standards. All electrical wiring must be in accordance with current electrical authority regulations and all wiring connections to be as per electrical diagram provided with the unit.
CAUTION
- DO NOT inspect the unit by yourself. Ask a qualified HVAC technician to perform the inspection.
- To prevent product deterioration, do not use the air conditioner for preservation purposes (storage of food, plants, animals, works of art, etc.).
- DO NOT operate the air conditioner with wet hands. It may cause electric shock.
- DO NOT touch the evaporator coils inside the indoor unit. The evaporator coils are sharp and may cause injury.
- DO NOT place items that might be affected by moisture damage under the indoor unit. Condensation can occur at a relative humidity of 80%.
- DO NOT expose heat-producing appliances to cold air or place them under the indoor unit. This may cause incomplete combustion or deformation of the unit due to the heat.
- If the air conditioner is used together with other heating devices, thoroughly ventilate the room to avoid oxygen deficiency.
- DO NOT climb onto or place objects on top of the outdoor unit.
- DO NOT operate the air conditioner when using fumigant insecticides. The chemicals may become layered with the unit and endanger those who are hypersensitive to chemicals.
- DO NOT let children play with the air conditioner.
- DO NOT operate the air conditioner in a wet room (e.g. bathroom or laundry room). This can cause electrical shock and cause the product to deteriorate.
WARNING
This air-conditioning unit contains R-32 refrigerant (CLASS A2L) which is
mildly flammable.
NOTE
- Service, maintenance, repairs and decommissioning of this unit must be performed by a licensed HVAC technician; qualified to handle R-32 refrigerant.
- R-32 refrigerant is odourless, if the refrigerant gas comes into contact with fire, it may emit a poisonous gas.
- Do not continuously operate open flames and ignition sources in the room.
Unit Specification and Features
03.01. Unit Parts
Display Code | Display Code Explanation |
---|---|
Display window for indicating temperature, operation features and error |
codes.
| Displayed for three seconds when:
•TIMER ON is set
•IONISER, SWING, TURBO, ECO, BREEZE AWAY, INTUITIVE PROXIMITY SENSOR or QUIET
feature is turned on
| Displayed for three seconds when:
•TIMER OFF is set
•IONISER, SWING, TURBO, ECO, BREEZE AWAY, INTUITIVE PROXIMITY SENSOR or QUIET
feature is turned off
| Displayed when the system is defrosting
| Displayed when Active Clean feature is turned on
| Displayed when Freeze Protection mode is turned on
| Displayed when ECO+ feature is activated
| Displayed when Easyconnect is installed
| Displayed when Indoor unit is in mode conflict with another operating indoor
unit (applicable to multi-split “MRC” installations only)
NOTE
Refer to remote manual for full features list.
Operating Conditions
Optimal performance for the COOL, HEAT, and DRY mode can be achieved in the
temperature ranges shown in the table below. If the unit is used outside of
these ranges, certain safety protection features will activate and cause the
unit to perform at a reduced capacity.
NOTE
Room relative humidity should be less than 80%. If the air conditioner
operates in room with relative humidity greater than 80%, the surface of the
air conditioner may attract condensation. Please sets the vertical air flow
louvre to its maximum angle and set HIGH fan mode.
To further optimize the performance of your unit, do the following:
- Keep doors and windows closed.
- Limit energy usage by using TIMER ON and TIMER OFF functions.
- Do not block air inlets or outlets.
- Regularly inspect and clean air filters.
Features
Auto-Restart
If the unit loses power, it will automatically restart with the prior settings
once power has been restored.
Anti-mildew
When the unit is turned off after COOL, AUTO or DRY mode, the unit will
continue to operate a low power to dry up condensed water to prevent mildew
growth.
Easyconnect Control (Optional)
Allows you to control the unit using a mobile phone and a wireless connection.
Installation is required to be undertaken by a licensed technician.
Easyconnect is an accessory that may be purchased separately.
Louvre Angel Memory
When turning on your unit, the louvre will automatically resume its former
angle. Aim the louvre higher to avoid direct airflow. This setting is found
under the SET menu.
Active Clean Function
It washes away dust, mold and grease when it adheres to the heat exchanger, by
automatically freezing and then rapidly thawing frost. Active Clean function
is used to produce more condensed water to improve the cleaning effect. After
cleaning, the internal blower fan operates with hot air to blow-dry the
evaporator and prevent the growth of mold.
When this function is turned on, the indoor unit will display CL. After 20 to
45 minutes, the unit will turn off automatically and Active Clean function will
be deactivated.
Breeze Away
This feature stops direct air from blowing onto you.
Refrigerant Leakage Detection
The indoor unit will automatically display EL0C when it detects refrigerant
leakage. Switch system off and contact service or installer.
Intuitive Proximity Sensor
This feature detects the occupancy of the people in the room. When in COOL
mode, if you are away for 30 minutes, the unit will automatically lower the
frequency of the unit to save energy. The unit will automatically resume
operation after sensing activity in the room.
LED Display
Press the LED button on the remote control to turn off the indoor unit panel
display and cancel the ‘beep’ noise.
Freeze Protection
When the unit is on HEAT mode and indoor temperature drops below 8 °C – FP
will be displayed and system will enter freeze protection mode.
NOTE
Lightning or any electronic interference nearby may cause the unit to
malfunction. If this happens, reset the power mains (isolator). Press the
ON/OFF button on the wired controller to restart operation.
05.01. Setting Vertical Angle of Air Flow
While the unit is on, use the SWING button on the remote control to set the
vertical angle airflow direction. Refer to Remote Control manual for more
details.
05.02. Setting Horizontal Angle of Air Flow
While the unit is on, press and hold the SWING button on the remote control to
set the vertical angle airflow direction. Refer to Remote Control manual for
more details.
NOTE
- When using COOL or DRY mode, do not set vertical louvre to the minimum angle for long periods of time. This can cause water to condense on the louvre blade, which may drop on your floor or furnishings.
- When using COOL or HEAT mode, setting the vertical louvre to the minimum angle can reduce the performance of the unit due to restricted air flow.
- Do not move louvre by hand. This will cause the louvre to become out of sync. If this occurs, reset mains power supply isolator to restart the unit. This will reset the louvre.
CAUTION
Do not put your fingers in or near the blower. The high-speed fan inside the
unit may cause injury.
05.03. Sleep Operation
The SLEEP function is used to decrease energy usage while you sleep and do not
need the same temperature settings to stay comfortable. This function can only
be activated via the remote control.
Press the SLEEP button when you are ready to go to sleep. When in COOL mode,
the unit will increase the temperature by 1°C after 1 hour, and will increase
an additional 1°C after another hour. When in HEAT mode, the unit will
decrease the temperature by 1°C after 1 hour, and will decrease an additional
1°C after another hour.
It will hold the new temperature for 7 hours, then the unit will turn off
automatically.
NOTE
The SLEEP function is not available in FAN or DRY mode.
Manual Operation
How to operate your unit without the remote control
In the event that your remote control fails to work, your unit can be operated
manually with the MANUAL CONTROL button located on the indoor unit (shown in
image below). Note that manual operation is not a long-term solution, and that
operating the unit with your remote control is strongly recommended.
To operate your unit manually:
- Locate the MANUAL CONTROL button as shown on the image on the next page.
- Press the MANUAL CONTROL button one time to activate FORCED AUTO mode. The display will show 24.0c.
- Press the MANUAL CONTROL button again to activate FORCED COOLING mode. The display will show fC.
- Press the MANUAL CONTROL button a third time to turn the unit Off.
FORCED AUTO MODE
The unit will go to AUTO mode with 24˚C set point.
FORCED COOL MODE
The outdoor unit will run at minimum capacity and indoor fan in low speed.
After 30 minutes, the system will go to AUTO mode with 24˚C set point.
CAUTION
The manual button is intended for testing purposes and emergency operation
only. Please do not use this function unless the remote is lost and it is
absolutely necessary. To restore regular operation, use the remote control to
activate the unit.
Care and Maintenance
NOTES
Apart from filter cleaning, all other general maintenance and care of systems
should be undertaken by a licensed technician.
Service, maintenance, repairs and decommissioning of this unit must be
performed by a licensed HVAC technician; qualified to handle R-32 refrigerant.
Maintenance Procedures
This section describes the procedures that must be performed as a part of
normal maintenance program. Regular servicing of equipment by licensed
technician is highly recommended. Regular servicing of your unit helps in
maintaining its optimum performance and reliability. The checklist and service
periods provided on this manual are guides only, as some sites may require
more frequent servicing. Always disconnect electrical power to the unit before
performing these procedures. It is always a safe practice to observe all
safety warnings and cautions when conducting maintenance tasks.
WARNING
Hazardous Voltage !
Always make sure that all power supply, including remote controls, are
disconnected before performing maintenance.
Observe proper LOCK-OUT/TAG-OUT procedures to ensure that power cannot be
inadvertently energised. Failure to disconnect power before maintenance
procedures can result in serious injury and/or death.
This unit is charged with R-32 mildly flammable refrigerant.
DANGER
Live Electrical Connections!
It may be necessary to work with live electrical components on certain
maintenance tasks. Only licensed electricians and qualified technicians are
allowed to perform these tasks.
Beware of Rotating Fan Blades!
Always make sure that all power supply, to the Outdoor Fans are turn Off and
isolated.
Observe WH&S safety procedures, do not wear loose clothing and any jewellery
when working near the fans.
Wear PPE whenever performing any maintenance procedures.
Observe all necessary procedures when working in a confined space.
Annual Maintenance Checklists
- Perform general maintenance inspections.
- Perform scheduled start-up checks.
- Leak test refrigerant circuits.
- Inspect contacts of all contactors and relays. Replace all worn contacts as required.
- Inspect, clean and tighten all electrical connections.
- Check fans for balanced operation. Make sure that there are no loose screws / bolts, no fan blades interference and no damage to the fans and guards.
- Inspect the air filters, clean or replace as required.
- Clean and repaint any corroded panel section.
- Ensure no blockage of airflow through variable speed drive.
Cleaning the Condenser Coils
Clean the coils at least once a year or more frequently if unit is located in
a dusty and dirty environment, in order to maintain your system’s proper
operating performance. High discharge pressures are good indication that the
coils need cleaning. When using detergent or solvents to clean the coils,
follow the manufacturer’s instructions to avoid potential damage to the coils
and to the unit.
To clean the refrigerant coils, use a soft brush and water spray, such as
garden hose or pressure washer with low pressure nozzle.
WARNING
Do Not Use High Alkaline Detergent!
When using detergent for coil cleaning, ensure that the alkaline level is no
higher than 8.5, which can cause corrosion damage to the coils.
No Water into the Electrical Compartments!
Ensure consideration is given to the possibility of water entering the
electrical compartments during cleaning of the condenser coil.
Coil Cleaning Procedures
- Disconnect power to the unit.
- Remove the louvred panels from the unit to gain access to the air inlet side of the coils.
- Use a soft brush to remove loose dirt and debris from both sides of the coils.
- Straighten bent coil fins with fin comb.
- Prepare the detergent solutions according to the manufacturer’s instructions.
- Spray solution at a 90° angle to the coils, keeping a minimum nozzle spray angle of 15°, with at least a 1800mm distance from the coils and 600 psi pressure.
- Spray leaving air side of the coils first then the air inlet side. Allow the solution to stand on the coils for five minutes.
- Rinse both sides of the coils with cool clean water.
- Inspect the coils, if they are still dirty, repeat the cleaning procedure.
- Clean and wipe dry the outer and inner sides of the unit, the refrigerating parts and other components.
- Ensure that the condensate drain lines are not blocked.
- Reinstall all unit panels, covers and guards.
- Restore electrical power to the unit after ensuring all electrical components are dry.
Air Filter Cleaning Procedure
A clogged air conditioner can reduce the cooling efficiency of your unit, and
can also be bad for your health. Make sure to clean the filter once every two
weeks. (Refer to image on next page)
- The air filter is at the top of the indoor unit.
- Grip the tab on the end of the filter, lift it up,then pull it towards yourself.(See image below)
- Clean the air filter with warm, soapy water. Be sure to use a mild detergent.
- Rinse the filter with fresh water, then shake off excess water.
- Dry it in a cool, dry place, and refrain from exposing it to direct sunlight.
- Slide the air filter back into place and clip it into the indoor unit.
Filter is held in place by mag pull magnets, which helps in easily re-fitting
the filter after cleaning. Maintenance – Long Periods of Non-
Use
If you plan to not use your air conditioner for an extended period of time, do
the following: Maintenance – Pre-Season Inspection
After long periods of non-use, or before periods of frequent use, do the
following: CAUTION
- Any unit repairs, maintenance and cleaning of outdoor unit should be performed by qualified HVAC technician.
- Filter cleaning can and should be regularly performed by product owner as required.
Troubleshooting
SAFETY PRECAUTIONS
If ANY of the following conditions occurs, turn off your unit immediately!
- You smell a burning odour
- The unit emits loud or abnormal sounds
- A power fuse blows or the circuit breaker frequently trips
- Water or other objects fall into or out of the unit
DO NOT ATTEMPT TO FIX THESE YOURSELF! CONTACT Authorised SERVICE PROVIDER
IMMEDIATELY!
The following problems are not a malfunction and in most situations will not
require repairs.
Fault | Possible Causes |
---|---|
Unit does not turn on when pressing ON/OFF button | The Unit has a 3-minute |
protection feature that prevents the unit from overloading.
The unit cannot be restarted within three minutes of being turned off.
The unit changes from COOL/HEAT mode to FAN mode| The unit may go into a
defrost setting, to prevent frost forming on the unit. During this operation
dF will be displayed on the indoor unit Once the temperature increases, the
unit will start operating in the previously selected mode again.
The set temperature has been reached, at which point the unit turns off the
compressor. The unit will continue operating when the temperature fluctuates
again.
The indoor unit emits mist| In humid regions, a large temperature difference
between the room’s air and the conditioned air can cause mist.
Both the indoor and outdoor units emit mist| When the unit restarts in HEAT
mode after defrosting, mist may be emitted due to moisture generated from the
defrosting process.
The indoor unit makes noises| A rushing air sound may occur when the louvre
resets its position.
A squeaking sound may occur when running the unit due to expansion and
contraction of the unit’s plastic parts.
Both the indoor unit and outdoor unit make noises| Low hissing sound during
operation: This is normal and is caused by refrigerant gas flowing through
both indoor and outdoor units.
Low hissing sound when the system starts, has just stopped running, or is
defrosting: This noise is normal and is caused by the refrigerant gas stopping
or changing direction.
Squeaking sound: Normal expansion and contraction of plastic and metal parts
caused by temperature changes during operation can cause squeaking noises.
The outdoor unit makes noises| The unit will make different sounds based on
its current operating mode.
Dust is emitted from either the indoor or outdoor unit| The unit may
accumulate dust during extended periods of non-use, which will be emitted when
the unit is turned on. This can be mitigated by covering the unit during long
periods of inactivity.
At the end of a cycle, the outdoor fan will run in reverse, expelling dust and debris from coil surface.
The unit emits a bad odour| The unit may absorb odours from the environment
(such as furniture, cooking, cigarettes, etc.) which will be emitted during
operations.
The unit’s filter have become mouldy and should be cleaned.
The fan of the outdoor unit does not operate| During operation, the fan speed
is controlled to optimize product operation.
When troubles occur, please check the following points before contacting a repair company.
Fault | Possible Causes | Remedies |
---|---|---|
Poor Cooling Performance | Temperature setting may be higher than ambient room | |
temperature. | Lower the temperature setting. | |
The heat exchanger on the indoor or outdoor unit is dirty. | Contact a |
qualified service technician.
The air filter is dirty.| Remove the filter and clean it according to
instructions.
The air inlet or outlet of either unit is blocked.| Turn the unit off, remove
the obstruction and turn it back on.
Doors and windows are open.| Make sure that all doors and windows are closed
while operating the unit.
Excessive heat is generated by sunlight.| Close windows and curtains during
periods of high heat or bright sunshine.
Too many sources of heat in the room (people, computers, electronics, etc.).|
Reduce amount of heat sources.
Low refrigerant due to leak or long-term use.| Contact a qualified service
technician.
QUIET mode is activated.| QUIET mode can lower product performance
by reducing operating frequency. Turn off QUIET mode.
The unit is not working| Power failure.| Wait for the power to be restored.
The power is turned off.| Turn on the power.
The fuse is burned out.| Contact a qualified service technician.
Remote control batteries are dead.| Replace batteries.
The Unit’s 3-minute protection has been activated.| Wait three minutes after
restarting the unit.
Timer is activated.| Turn timer off.
The unit starts and stops frequently| There’s too much or too little
refrigerant in the system.| Contact a qualified service technician.
Incompressible gas or moisture has entered the system.| Contact a qualified
service technician.
The compressor is broken.| Contact a qualified service technician.
The voltage is too high or too low.| Contact a qualified service technician.
Poor Heating Performance| The outdoor temperature is too low.| Operate system
at a lower set temperature, then gradually increase set temp to desired level.
Cold air is entering through doors and windows.| Make sure that all doors and
windows are closed during use.
Low refrigerant due to leak or long-term use.| Contact a qualified service
technician.
Indicator lamps continue flashing| The unit may stop operation or continue to
run safely. Some error codes will allow the unit to continue operating. If the
indicator lamps continue to flash or error codes appear, wait for about 10
minutes. The problem may resolve itself.
If not, disconnect the power, then connect it again. Turn the unit on.
If the problem persists, disconnect the power and contact a qualified service
technician.
Error code appears in the window display of indoor unit:
E(x), P(x), F(x)…
EH(xx), EL(xx), EC(xx)…
PH(xx), PL(xx), PC(xx)…
NOTE
If your problem persists after performing the checks and diagnostics above,
turn off your unit immediately and contact ActronAir on 1800 119 229 for
technical support or warranty.
Display / Error Codes
When troubles occur, please check the following points before contacting a qualified service technician.
Display | Timer Lamp | Running Lamp | Information |
---|---|---|---|
— | — | Defrost | |
— | — | Filter cleaning reminder(power on display for 15 seconds) | |
— | — | Active clean | |
— | — | Filter replacement reminder(power on display for 15 seconds) | |
— | — | Heating in room temperature under 8°C | |
— | — | Forced cooling | |
— | — | AP mode of WIFI connection | |
— | — | Remote switched off | |
1 time | OFF | Indoor unit EEPROM parameter error | |
2 times | OFF | Indoor/outdoor unit communication error | |
3 times | OFF | Zero-crossing signal detection error | |
4 times | OFF | The indoor fan speed is operating outside of the normal range | |
5 times | OFF | Outdoor unit EEPROM parameter error | |
5 times | OFF | Condenser coil temperature sensor T3 is in open circuit or has |
short circuited
| 5 times| OFF| Outdoor room temperature sensor T4 is in open circuit or has
short circuited
| 5 times| OFF| Compressor discharge temperature sensor TP is in open circuit
or has short circuited
| 5 times| OFF| Evaporator coil outlet temperature sensor T2B is in open
circuit or has short circuited(for free-match indoor units)
| 6 times| OFF| Indoor room temperature sensor T1 is in open circuit or has
short circuited
| 6 times| OFF| Evaporator coil middle temperature sensor T2 is in open
circuit or has short circuited
| 12 times| OFF| The outdoor fan speed is operating outside of the normal
range
| 09 times| OFF| Indoor PCB/Display board communication error
| 8 times| OFF| Refrigerant leakage detection
| 7 times| FLASH| IPM malfunction or IGBT over-strong current protection
| 2 times| FLASH| Over voltage or over low voltage protection
| 3 times| FLASH| Top temperature protection of compressor or High temperature
protection of IPM module or High pressure protection
| 5 times| FLASH| Inverter compressor drive error
| 1 time| FLASH| Current overload protection
| 6 times| FLASH| “Communication error between outdoor main chip and
compressor driven chip”
| 7 times| FLASH| Low pressure protection
| –| –| AP mode is actived but there is no WIFI kit installed
| 1 times| ON| Indoor units mode conflict(match with multi outdoor unit)
Maintenance Frequency Checklist
Regular servicing of equipment by a qualified technician is recommended every
12 months for residential applications and every quarter for commercial
applications. Regular servicing of your unit helps in maintaining its optimum
performance and reliability. The following checklist and service periods are
provided as a guide only, as some sites may require more frequent servicing.
Electrical
Parts| Service Frequency| Detail of Service Check|
Service Methods
---|---|---|---
1 Mth| 3 Mth| 6 Mth| 1 Yr
Printed Circuit Boards| | | | | Visual Inspection.| Tighten Terminals as
necessary on printed circuit boards.
Electrical Connections| | | | | Check all electrical terminals, mains,
communications, etc.| Re-tighten if loose.
Magnetic Contactor| | | | | Check for loose terminal connections.| Tighten
electrical terminals. Remove any dust.
Indoor Unit
Parts| Service Frequency| Detail of Service Check|
Service Methods
---|---|---|---
1 Mth| 3 Mth| 6 Mth| 1 Yr
Casing/ Panels and Frames| | | | | Visual check for damage, rust
and dust accumulation.| For highly corrosive environment, wash panels
quarterly with water and neutral detergent solution. Wax panels. Repair / re-
paint where required.
Insulation| | | | | Visual check for insulation conditions.| Repair / replace
insulation material.
Fan| | | | | Visual check for run out of balance and dust attached.| Clean off
dust as necessary to negate possibility of fan running out of balance.
Motor
| | | | ▲| Visual check on wiring. Insulation resistance check to be carried
out annually.| Measure insulation resistance to earth with Megger.
Insulation resistance should be more than 1M▲.
Heat Exchanger| | | | | Check for clogging by dust. Check for leaks / damage.|
Clean air inlet side as necessary. Straighten any bent fins using fins comb.
Drain Pan/ Condensation line| | | | | Check for obstructions and free flow of
water.| Clean to eliminate obstructions/ sludge and check condition of pan.
Pour water to ensure free flow.
Filter*| | | | | Check for clogging by dust.| Clean / Replace Filter.
Temperature Readings| | | | ****
| Measure air on and air off.| Place temperature probe in return and supply air of unit. Be careful not to touch the fan blower whilst checking temperature with thermometer.
*Service period for filter cleaning may vary depending on operating time and surrounding environment
Outdoor Unit
Parts| Service Frequency| Detail of Service Check| Service
Methods
---|---|---|---
1 Mth| 3 Mth| 6 Mth| 1 Yr
**** Casing/ Panels and Frames| | | | | Visual check for damage, rust and
dust accumulation.| For highly corrosive environment, wash panels quarterly
with water and neutral detergent solution. Wax panels. Repair / re-paint where
required.
Insulation| | | | | Visual check for insulation conditions.| Repair / replace
insulation material.
Fan
| | | | | Visual check for run out of balance and dust accumulation.| Clean off dust as necessary to negate possibility of fan running out of balance.
Motor
| | | | ▲| Visual check on wiring. Insulation resistance check to be carried
out annually.| Measure insulation resistance. Should be more than 1M▲.
Heat Exchanger| | | | | Check for clogging by dust. Check for leaks / damage.|
Clean air inlet side as necessary. Straighten any bent fins using fins comb.
Condensate Drain Line (if available)| | | | | Check for obstructions & free
flow of water.| Clean to eliminate obstructions/ sludge and check condition of
drain line. Pour water to ensure free flow.
Compressor
| | | | ▲| Check for high / low pressure. Measure insulation resistance. Check compressor for abnormal noise/vibrations.| Measure insulation resistance. Should be more than 1M▲. Ensure to isolate first the VSD from the compressor before measuring insulation resistance.
Compressor drive
| | | | ****
| For variable drive compressor check full operation of drive from minimum hertz to maximum, check fan operation of drive.| ****
Check compressor amperage & running frequency feedback from outdoor board seven segment display.
| | | | Ensure drive fresh air
path is clear and drive fan is operating correctly.
| Check ventilation holes on top and bottom of drive cover are clear of
leaves, pebbles or dirt.
Refrigeration Operational Readings| | | | | Make note of operational reading
in test cool/heat mode.| Check operating pressures, record super heat and sub-
cool values.
Safety Devices| | | | | Check calibration of safety devices.| Check resistance
of sensors, pressure cut in / cut out of pressure controls.
Faults| | | | | Check for any previous fault history on unit.| Investigate any
causes for previous faults, reset fault history.
That ’s better. That ’s Actron.
actronair.com.au
1300 522 722
©Copyright 2021 Actron
Engineering Pty Limited ABN 34 002767240. ®Registered Trade Marks of Actron
Engineering Pty Limited.
ActronAir is constantly seeking ways to improve the design of its products.
Therefore, specifi cations are subject to change without notice.
Owner’s Manual – Wall Hung Split System
Doc. No.9590-4011 Ver. 5 220616