CHAUVET Professional COLORado PXL Curve 12 GBW LED User Guide

June 13, 2024
Chauvet Professional

CHAUVET Professional COLORado PXL Curve 12 GBW LED

CHAUVET-Professional-COLORado-PXL-Curve-12-GBW-LED-
product

Product Information

The COLORado PXL Curve 12 is a lighting fixture designed for installation, use, and maintenance in various settings. It comes with a Quick Reference Guide (QRG) that provides important safety notes and instructions.

Model ID: COLORADOPXLCURVE12

Safety Notes
The Safety Notes included in the User Manual provide crucial information about the proper installation, use, and maintenance of the COLORado PXL Curve 12.

What is Included

  • COLORado PXL Curve 12 QRG Rev.
  • Quick Reference Guide

AC Power
The AC power requirements for the COLORado PXL Curve 12 are as follows:

Voltage Frequency Current Draw
100 V 60 Hz 8.13 A
120 V 60 Hz 6.70 A
208 V 60 Hz 3.80 A
230 V 50 Hz 3.44 A
240 V 60 Hz 3.30 A

Note: Do not exceed 12A on a single circuit. Power-linking cables can be purchased separately.

Mounting
Prior to mounting the COLORado PXL Curve 12, it is essential to read the Safety Notes provided. The following guidelines should be followed:

Control Panel Description

Button Function
Exits Button Exits from the current menu or function
Enable Button Enables the currently displayed menu or sets the currently

selected value into the selected function
Navigate Up Button| Navigates upwards through the menu list or increases the
numeric value when in a function
Navigate Down Button| Navigates downwards through the menu list or decreases the
numeric value when in a function

Product Usage Instructions

  1. Scan the QR code provided in the User Manual to access the product page, warranty terms, and the complete User Manual.
  2. Ensure that the product is properly connected to AC power using the appropriate AC plug and wires based on the region’s electrical standards.
  3. To extend the product’s lifespan, disconnect it from power via breaker or by unplugging it during periods of non-use.
  4. If power linking is desired, refer to the current draw table for the appropriate voltage and frequency combinations. Ensure that the total current draw does not exceed 12A on a single circuit. Power-linking cables can be purchased separately.
  5. Prior to mounting the product, carefully read the Safety Notes provided in the User Manual.
  6. Use at least 2 mounting points per product and ensure that the mounting clamps used can support the weight of the product.
  7. For Chauvet line mounting clamps, refer to the website http://trusst.com/productcategory/truss-clamps.
  8. Familiarize yourself with the control panel’s button functions for navigating menus and adjusting settings.

Safety Notes

These Safety Notes include important information about installation, use, and maintenance of the COLORado PXL Curve 12.

  • The luminaire is intended for professional use only.
  • The luminaire should be positioned so that prolonged staring into the luminaire at a distance closer than 16.4 ft (5 m) is not expected.
  • If the external flexible cable or cord of this luminaire is damaged, it shall be replaced by a special cord or cord exclusively available from the manufacturer or its service agent.
  • The light source contained in this luminaire shall only be replaced by the manufacturer or its service agent or a similar qualified person.
  • CAUTION:
    • This product’s housing may be hot when operating. Mount this product in a location with adequate ventilation, at least 20 in (50 cm) from adjacent surfaces.
    • When transferring the product from extreme temperature environments, (e.g., cold truck to warm humid ballroom) condensation may form on the internal electronics of the product. To avoid causing a failure, allow the product to fully acclimate to the surrounding environment before connecting it to power.
    • Flashing light is known to trigger epileptic seizures. User must comply with local laws regarding notification of strobe use.
  • ALWAYS:
    • Disconnect from power before cleaning the product or replacing the fuse.
    • When using an IP65-rated product in an outdoor environment, use IP65- (or higher) rated power and data cable.
    • Replace and secure IP-rated protective covers to all power, data, USB, or other ports when not in use.
    • Replace the fuse with the same type and rating.
    • Use a safety cable when mounting this product overhead.
    • Connect this product to a grounded and protected circuit.
  • DO NOT:
    • Open this product. It contains no user-serviceable parts.
    • Look at the light source when the product is on.
    • Leave any flammable material within 3.28 ft (1 m) of this product while operating or connected to power.
    • Connect this product to a dimmer or rheostat.
    • Operate this product if the housing, lenses, or cables appear damaged.
    • Submerge this product (adhere to standards for the published IP rating). Regular outdoor operation is fine.
    • Permanently install outdoors in locations with extreme environmental conditions. This includes, but is not limited to:
    • Exposure to a marine/saline environment (within 3 miles of a saltwater body of water).
    • Locations where normal temperatures exceed the temperature ranges in this manual.
    • Locations that are prone to flooding or being buried in snow.
    • Other areas where the product will be subject to extreme radiation or caustic substances.
    • ONLY use the hanging/mounting bracket to carry this product.
    • The maximum ambient temperature is 113 °F (45 °C). Do not operate this product at higher temperatures.
    • The minimum startup temperature is -14°F (-10°C). Do not start the product at lower temperatures.
    • To eliminate unnecessary wear and improve its lifespan, during periods of non-use completely disconnect the product from power via breaker or by unplugging it.
    • In the event of a serious operating problem, stop using immediately.

What is Included

  • COLORado PXL Curve 12
  • Seetronic Powerkon IP65 power cable
  • 2 omega brackets with mounting hardware
  • Quick Reference Guide

AC Power

This product has an auto-ranging power supply that can work with an input voltage range of 100–240 VAC, 50/60 Hz.

AC Plug

Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live Black Brown Yellow/Brass
AC Neutral White Blue Silver
AC Ground Green/Yellow Green/Yellow Green

To eliminate unnecessary wear and improve its lifespan, during periods of non- use completely disconnect the product from power via breaker or by unplugging it.

Power Linking
It is possible to power link COLORado PXL Curve 12 products. See the table below for the current draw at each voltage and frequency:

 | 100 V, 60 Hz| 120 V, 60 Hz| 208 V, 60 Hz| 230 V, 50 Hz| 240 V, 60 Hz
---|---|---|---|---|---
Current Draw| 8.13 A| 6.70 A| 3.80 A| 3.44 A| 3.30 A

Never exceed 12A on a single circuit. Power-linking cables can be purchased separately.

Mounting

Before mounting this product, read the Safety Notes. Use at least 2 mounting points per product. Make sure the mounting clamps are capable of supporting the weight of the product. For our Chauvet line of mounting clamps, go to http://trusst.com/productcategory/truss-clamps.

Mounting Diagram

CHAUVET-Professional-COLORado-PXL-Curve-12-GBW-LED-fig-
\(2\)

Control Panel Description

Button Function
< MENU> Exits from the current menu or function
< ENTER> Enables the currently displayed menu or sets the currently

selected value into the selected function
< UP>| Navigates upwards through the menu list or increases the numeric value when in a function
< DOWN>| Navigates downwards through the menu list or decreases the numeric value when in a function

Contact Us

Chauvet World Headquarters

Technical Support

Chauvet U.K.

Chauvet Mexico

Chauvet Germany

Visit the applicable website above to verify our contact information and instructions to request support. Outside the U.S., U. K., Ireland, Mexico, France, Germany, or Benelux, contact the dealer of record.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Chauvet Professional User Manuals

Related Manuals