DELTA HCHO 7 UNO IAQ Sensor Installation Guide

June 13, 2024
Delta

UNO IAQ Sensor Installation Guide

DELTA HCHO 7 UNO IAQ Sensor

Product Development Team, BABG
Aug. 25 2023 ver.02

HCHO 7 UNO IAQ Sensor

DELTA HCHO 7 UNO IAQ Sensor - Fig 1

Placement

UNO lite is recommended to be installed below condition and at a height of 0.8~1.5 meters (2.56~ 4.8 feet ).

DELTA HCHO 7 UNO IAQ Sensor - Fig 2

Located at least 5 meters(~16 feet) away from operable windows, doors and diffusers

DELTA HCHO 7 UNO IAQ Sensor - Fig 3

Delta Confidential

Step 1
Select suitable Wall Mount Frame to meet different Junction

DELTA HCHO 7 UNO IAQ Sensor - Fig 4

Plastic Wall Mount Cover Dimension

DELTA HCHO 7 UNO IAQ Sensor - Fig 5

Plastic well module cradle is an accessory that comes with the product (Both UNO next and UNO lite).

Small Wall Mount frame Dimension

Delta Part No.: 3487312702

DELTA HCHO 7 UNO IAQ Sensor - Fig 6

Compact Wall Mount Frame for 1-Gang Junction Boxes (Compatible with US, EU, & TW Junction Box)
Delta Part No.: 3487312702
This well module frame is an accessory that comes with the product (UNOlite).

Large Wall Mount frame Dimension
Delta Part No.: 3994041800

DELTA HCHO 7 UNO IAQ Sensor - Fig 7

The Wall Mount Frame and Cover for China 86 or 2-Gang Junction Boxes (Compatible with US,
EU, & TW Junction box)
Delta Part No.: 3994041800

Step 1.1
Install small Wall Mount frame with 1 Gang Embedded Junction Box

DELTA HCHO 7 UNO IAQ Sensor - Fig 8

Step 1.2
Install large Wall Mount Kit with 2 Gang
Embedded Junction Box

DELTA HCHO 7 UNO IAQ Sensor - Fig 9 Step 1.3
Install large Wall Mount cover with Junction Box InstallationDELTA HCHO 7
UNO IAQ Sensor - Fig 10

Step 2
Insert wire cables to terminal plugDELTA HCHO 7 UNO IAQ Sensor - Fig
11 Step 3
Insert terminal plug and DC power plug to UNO liteDELTA HCHO 7 UNO IAQ
Sensor - Fig 12 Step 4
Mount UNO lite on four buckles of Wall Mount Fix UNO lite with M4 screw by Hex screw driverDELTA HCHO 7 UNO IAQ Sensor - Fig 13

Finished Installation

Installation Guide for UNO IAQ Sensor

Step 1: Determine Installation Height
The optimal installation height for the product is between 0.8 to 1.5 meters (2.56 to 4.8 feet) from the ground.
Step 2: Choose Installation Method
Option A: Wall Mount Installation
Utilize the wall mount provided in the package.
The wall mount is designed with screw hole spacing (60mm and 84mm) compatible with power boxes in various countries.
Ensure the power box is horizontally installed, following the configuration depicted in Figure 1.
Option B: Power Box Installation Alternatively, install the product in a power box.
Step 3: Arrange Power and Data Lines
Before proceeding with installation, ensure that power supply and data lines are laid out as per the specifications.
Step 4: Mount the Product
Follow these steps:
Refer to Figure 2 for guidance.
Attach and secure the wall mount, confirming all four buckles are properly affixed.
Step 5: Secure Installation
Proceed as follows:
Refer to Figure 3.
Use an M4 hex socket screws along with a hexagonal screwdriver to fasten the product securely in place.

DELTA HCHO 7 UNO IAQ Sensor - Fig 15

Smarter. Greener. Together.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals