MINOSTON MR40Z S2 Remote Control Switch Instruction Manual
- June 13, 2024
- Minoston
Table of Contents
MINOSTON MR40Z S2 Remote Control Switch
Specifications
- Battery: CR2032*2
- Frequency: 908.42MHz
- Temperature Range: 32°F~104°F
- Indoor use in dry location
- Please read this online guide carefully at Minoston.com
- Do not use it in direct contact with water.
- Contains small parts, please keep away from children.
If you have any questions, please contact us at
- Scan QR code or visit ask@minoston.com and www.minoston.com
Power the device
- Open the remote cover by hand and push it to separate the two halves.
- Remove battery tabs.
Features of S2 Remote Control Switch
- Power by battery. No wiring required. Note the ± direction of the battery.
- Control other Z-wave devices and enable scenes with a click of a button.
- The device with S2 and SmartStart support.
Z- wave Control
Adding Device to Your Hub and Z-Wave Network for QR code
Choose your hub and scan the QR code with your phone’s camera and add it to
Smartstar
To add the device
- Add the device to your Z-Wave network by following the instructions of your Z-Wave controller.
- Once the controller is preparing to add your device, press the FIRST BUTTON(ONLY) 5 times. The LED is flashing in blue during inclusion, and it is solid green for 2 seconds after inclusion successfully. LED will be solid in red for 2 seconds after inclusion failed.
To remove the device
- Remove the device from Your Z-Wave controller by following the instructions.
- Once the controller is preparing to remove your device, press the SECOND BUTTON(ONLY) 5 times. The LED is flashing in purple during exclusion, and it is solid green for 2 seconds after exclusion successfully. LED will be solid in red for 2 seconds after exclusion failed.
Wake up the Device
- Press the THIRD BUTTON 5 times quickly, LED will stay solid on blue when awake and will turn off when device goes back to sleep mode.
Factory reset
- Manual: Reset: Press the FOUR BUTTON 5x, then press it 5x again when the red light is flashing.
Regarding SmartThings usage exceptions:
If the SmartThings replacement service results in abnormal use of the product,
please install a new driver according to the following solutions.
- Scan the above QR code(left) to open the SmartThings Edge Driver subscription channel of the product.
- Log in to the SmartThings account after opening the SmartThings Edge Driver subscription channel.
- Select the SmartThings Hub you are using, and click “Enroll”.
- After “Enroll” is completed, click “Available Drivers”.
- After entering the “Available Drivers” page, select “Z-Wave Button” to “Install”.
Note: Please scan the QR code on the right to view the guide video.. Regarding SmartThings usage exceptions: If the SmartThings replacement service results in abnormal use of the product,please install a new driver(edge driver) according to the following solutions.
Configuration Parameter:
- Parameter 1 indicates battery report threshold %. Use it to set battery levels for battery reports.
- size=1 byte Available range : 1-20
- (DEFAULT): 10%
- Parameter 2 indicates the low battery alarm report. Use it to set battery levels for low battery reports.
- size=1 byte Available range : 5%-20%
- (DEFAULT) : 5%
- Parameter 3 LED indicates Indicator Color for the First button of remote control (Scene 1 activation).
- Choose the LED indicator color for the First button of remote control triggers.
- size=1 byte Available settings: 0–6
- Value=0 White
- Value=1 Purple
- Value=2 Orange
- Value=3 Cyan
- (DEFAULT) : 0
- Value=4 Red
- Value=5 Green
- Value=6 Blue
- Parameter 4 LED indicates Indicator Color for the Second button of remote control (Scene 2 activation). Choose the LED indicator color for the Second button of remote control triggers.
- size=1 byte Available settings: 0–6
- Value=0 White
- Value=1 Purple
- Value=2 Orange
- Value=3 Cyan
- (DEFAULT) : 1
- Value=4 Red
- Value=5 Green
- Value=6 Blue
- Parameter 5 indicates LED Indicator Color for the Third button of remote control (Scene 3 activation). Choose the LED indicator color for the Thrid button of remote control triggers.
- size=1 byte Available settings: 0–6
- Value=0 White
- Value=1 Purple
- Value=2 Orange
- Value=3 Cyan
- (DEFAULT) : 2
- Value=4 Red
- Value=5 Green
- Value=6 Blue
- Parameter 6 indicates LED Indicator Color for the Fourth button of remote control (Scene 4 activation).Choose the LED indicator color for the Fourth button of remote control triggers.
- size=1 byte Available settings: 0–6
- Value=0 White
- Value=4 Red
- Value=1 Purple
- Value=2 Orange
- Value=3 Cyan
- (DEFAULT) : 3
- Value=5 Green
- Value=6 Blue
- Parameter 7 indicates LED Indicator Brightness. Choose the LED indicator Brightness level. size=1 byte Available settings: 0–10
Value=0 LED off
- Value=1 10% Brightness
- Value=2 20% Brightness
- Value=3 30% Brightness
- Value=4 40% Brightness
- Value=5 50% Brightness
- Value=6 60% Brightness
- Value=7 70% Brightness
- Value=8 80% Brightness
- Value=9 90% Brightness
- Value=10 100% Brightness
This remote supports four scene controls
- Scene 1 : First Button 1-Tap/2-Tap/3-Tap/Held/Released
- Scene 2 : Second Button 1-Tap/2-Tap/3-Tap/Held/Released
- Scene 3 : Third Button 1-Tap/2-Tap/3-Tap/Held/Released
- Scene 4 : Fourth Button 1-Tap/2-Tap/3-Tap/Held/Released
Association Group:
This remote supports 9 Association Group controls
- Support group number: 9
- Each group max. Support 10 devices
- Group 1 Lifeline
- Group 2 First button press 1x send basic set 0xff, Second button press 1x send basic set 0x00.
- Group 3 Third button press 1x send basic set 0xff, Fourth button press 1x send basic set 0x00.
- Group 4 First button hold more than 0.5s send SWITCH_MULTI – LEVEL_START_LEVEL_CHANGE(Dim Up) First button release send SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE Second button hold more than 0.5s send SWITCH_MULTI – LEVEL_START_LEVEL_CHANGE(Dim Down) Second button release send SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE
- Group 5 Third button hold more than 0.5s send SWITCH_MULTI – LEVEL_START_LEVEL_CHANGE(Dim Up) Third button release send SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE Fourth button hold more than 0.5s send SWITCH_MULTI – LEVEL_START_LEVEL_CHANGE (Dim Down)
- Fourth button release send SWITCH_MULTILEVEL_STOP_LEVEL_CHANGE
- Group 6 First button press 1x to toggle on/off (send basic set 0xff or 0x00).
- Group 7 Second button press 1x to toggle on/off (send basic set 0xff or 0x00).
- Group 8 Third button press 1x to toggle on/off (send basic set 0xff or 0x00).
- Group 9 Fourth button press 1x to toggle on/off (send basic set 0xff or 0x00).
Command Class
- Generic Device Class:0x18 – WALL_CONTROLLER
- Specific Device Class:0x00 – NOT_USED
Command Classes:
- 0x5E – COMMAND_CLASS_ZWAVEPLUS_INFO
- 0x85 – COMMAND_CLASS_ASSOCIATION
- 0x8E – COMMAND_CLASS_MULTI_CHANNEL_ASSOCIATION
- 0x59 – COMMAND_CLASS_ASSOCIATION_GRP_INFO
- 0x55 – COMMAND_CLASS_TRANSPORT_SERVICE
- 0x86 – COMMAND_CLASS_VERSION
- 0x72 – COMMAND_CLASS_MANUFACTURER_SPECIFIC
- 0x5A – COMMAND_CLASS_DEVICE_RESET_LOCALLY
- 0x73 – COMMAND_CLASS_POWERLEVEL
- 0x80 – COMMAND_CLASS_BATTERY
- 0x9F – COMMAND_CLASS_SECURITY_2
- 0x5B – COMMAND_CLASS_CENTRAL_SCENE
- 0x87 – COMMAND_CLASS_INDICATOR
- 0x70 – COMMAND_CLASS_CONFIGURATION
- 0x84 – COMMAND_CLASS_WAKE_UP
- 0x6C – COMMAND_CLASS_SUPERVISION
- 0x7A – COMMAND_CLASS_FIRMWARE_UPDATE_MD
FCC warning
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, (2) This device must accept any interference received, including interference that may cause undesired operation. changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
NOTE:
This equipment has been tested and found to comply with the limits for a Class
B digital device, pursuant to Part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However,
there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interfer- ence to radio or
television reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or more
of the following meas-ures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
FCC Radiation Exposure Statement:
This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This equipment should be installed and operated with minimum distance 20cm between the radiator& your body.
CAUTION – PLEASE READ!
This device is intended for installation in accordance with the National Electric Code and local regulations in the United States, or the Canadian Electrical Code and local regulations in Canada. If you are unsure or uncomfortable about performing this installation consult a qualified electrician.
MEDICAL EQUIPMENT
Please DO NOT use this plug to control Medical or Life Support equipment. This
device should never be used to control the On/Off status of Medical and/or
Life Support equipment.
OTHER WARNINGS
Risk of Fire / Risk of Electrical Shock / Risk of Burns
IMPORTANT SAFETY INSTRUCTIONS
- READ AND FOLLOW ALL SAFETY INSTRUCTIONS.
- Read and follow all instructions that are on the product or provided with the product.
- do not use an extension cord.
- Reference the National Electrical Code, NFPA 70, specifically for the installation of wiring andclearances from power and lighting conductors.
- Installation work and electrical wiring must be done by qualified person(s) in accordance with allapplicable codes and standards, including fire-rated construction.
- do not install or use within 10 feet of a pool
- do not use in a bathroom
WARNING:
Risk of Electric Shock. When used outdoors, install only to a covered Class A GFCI protected receptacle that is weatherproof with the power unit connected to the receptacle. If one is not provided, contact a qualified electrician for proper installation. Ensure that the power unit andcord do not interfere with completely closing the receptacle cover.
WARNING:
Risk of Electric Shock. Mount the unit at a height greater than 1 foot from
the ground surface
WARNING:
Risk of Electric fire. install only to a receptacle protected by 20A branch
circuit over current protection.
SAVE THESE INSTRUCTIONS – This manual contains important safety and operating instructions.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>