VIBOCOLD OSC 140S Convenience køler med Self Service front User Manual

June 4, 2024
VIBOCOLD

140S Convenience køler med Self Service front
User Manual

VIBOCOLD OSC 140S Convenience køler med Self Service front
-

 Safety

The device is designed to be operated by adults only. The child’s playing in the vicinity of the working device is inadmissible, all the more using the device in operation to play.
Live components
This symbol placed on a component or on a cover indicates the presence of live details. The component or cover can only be detached by an authorized service technician.
Putting up
If there is no inspection window at the back of the appliance, it shall be placed with its rear part against the wall. Connect the power cord only when the appliance is put into lace.
Transport
Before you move the appliance always pull out the power cord. Otherwise, there is a risk that the cable will be stretched and damaged, which can result in short circuit. Wear gloves while transporting the appliance because there may be sharp edges at the back of it.
Cleaning
Always pull out the power cord before you clean the appliance because there is a risk of coming close to voltage or rotating fans e.g. during cleaning of the condensers or during emoving dust from the compressor tank.
Storage
Store only the products that are intended for storage in the appliance. Never store explosive gases or
liquids, they can do harm to a person or property. Never store products in glass packaging in the freezer
compartment because the glass may crack.
Children
Keep an eye on children and make sure that they cannot reach the control panel, and voltage, and that they cannot get locked inside the appliance. Do not allow children to play with packing’s. Cling film may bear the risk of choking!
Handing over or disposal
Do not throw out the operating instructions as they shall be provided in case of handing over or disposing of the appliance.
Discarding old appliances
Cut off the power cord as close to the appliance as possible. Remove the doors so that playing children cannot be locked inside. The appliance shall be left at a place where recyclable electrical and electronic components are collected. For further information about recycling, contact local authorities or the vendor of the appliance.
Service
Always pull out the power cord before starting the service. The lights on the appliance and on the showcases are connected in such a way that the current does not break through the main switch. It is forbidden to:

  • connect the device to mains without ensuring of efficient equipotential switch system, store spoiled products,
  • place warm products inside the working chamber of the refrigerating device,
  • place unfrozen products to the freezing device,
  • cover and block the ventilation holes of the device, tilt the device more than 45°, but if it was necessary, wait about 1 hour before starting the device.
  • allowing the compressor oil to flow down,
  • store delicatessen products without packaging for more than 3 days,
  • store the products causing accelerated corrosion process (acids, bases),
  • lift and transport the refrigerator counters holding them by plastic edges,
  • place the shelves in drafts,
  • place the devices near heat sources.
  • in devices, the interior of which is finished with aluminum it is forbidden to store food products’ acidic character. Use only the devices made of acid-resistant steel for this purpose.

User guide
Read through this user guide carefully. However, it is not necessary that You as a user, study the 3rd part of this document, the SERVICE MANUAL, which is intended for service staff. Installation and mounting Transport It is recommended to transport the appliance to its mounting place using transport packaging. Avoid tilting the appliance during transport. If the appliance has been tilted significantly, wait 15 minutes before turning it on and let the compressor oil flow down to its initial position.
ATTENTION !! During transport and relocation, do not tilt the device more than 45°, because this can cause damage to the compressor.
Unpacking: Unpack the appliance out of the transport packaging and remove white plastic elements its shelves and walls. Check if the appliance is not damaged. Any damages shall immediately be reported to the supplier.
Mounting/putting into place: The appliance is intended to be used in indoor spaces. Pay attention that the bottom construction is not be damaged, shall any mechanical tools be used to put the appliance into place? In order to guarantee smooth operation and low energy consumption, it is recommended not to place the appliance close to units or elements that generate heat, or in places directly exposed to sunshine or draught, e.g. a draught from doors, air-conditioners or fans (A; B; C illustrations) The appliance in its standard version produces the estimated temperature at the ambient temperature between +15 and +25 ºC and relative humidity not exceeding 55 %,and climate class 3 according to the European norm EN 441, unless stated otherwise. During installation, proper ventilation shall be provided to the element of the chiller which generates heat, and in order to allow the evaporation of meltwater. The appliance shall be adjusted so that its placed as horizontally as possible. Maximum tilt can reach ± 0,5 degrees. Check if all legs are placed properly on the floor in order to ensure smooth operation of doors and locks.
VIBOCOLD OSC 140S Convenience køler med Self Service front -
Fig

Cleaning after mounting
Cleaning: Dry the appliance on the inside and outside before you start using it. Use a neutral detergent. If you use another detergent, finish the cleaning with a neutral one. See section 2.5 Cleaning.
Product start-up
Temperature
If the appliance has been stored in an unheated space so that the temperature of the machinery was below 0 degrees before the appliance is started it must be stored in an indoor space until the compressor temperature reaches +10 degrees, otherwise, the compressor could be damaged.
Start-up The appliance can be started for the first time 3 hours after it has been put into place. Connect the appliance to mains power using a protective earth socket. The device should be powered from a separate low-voltage circuit equipped with a protective cord and protected with fuse up to 10 A (shelves up to 16A). Before connecting mains, to the device check, the local voltage is compatible with the appliance’s requirements (data on rating plate). Start the appliance using the switch. The temperature of the appliance decreases and reaches the value set in the factory default settings. The products shall not be put into the appliance before the default value is reached. ATTENTION !!.

  1. It is not allowed to switch the device on without an efficient equipotential switch system!!! The device is equipped with a protective PE cord.
  2. Connecting the device to the electrical network should be done in such a way that the plug is visible and easily accessible for service. It is inadmissible to use extensions and branch joints!!!
  3. Before commencing any maintenance or cleaning activities, switch the device off, and then remove the plug from the power outlet. Eventual repairs of electrical installation and replacement of power cord can be done only by a certified electrician.

Usage
General information

Proper storage of products in both the fridge and freezer compartments are of great importance for their quality and freshness.
Destination
Fridges are designed for short-term storing of foiled food products, like dairy and pork butcher’s products, salads, etc., as well as beverages and processed food. Freezers are designed for storing of food products as above, previously frozen. Refrigeration level raisers are designed for dispensing and short-term storing of various vegetable salads. The salads are held in specially designed containers. The interior of the level raiser and containers are made of food-contact acid-resistant steel. The device can be used in groceries, bars, restaurants and gastronomic sites.
Proper operation

  • After receiving the device, check its technical condition and equipment according to the operating instruction; report possible damage to the seller within 24 hours.
  • Level the device in the operating place, if it is wheeled, block the brakes.
  • Maintain the device in good technical condition.
  • Do not overload the device, i.e. watch the load to be compliant with technical data, and watch the admissible payload of shelves.
  • Fill the refrigerating/freezing device interior after its initial cooling.
  • Clean the device interior with water solution of dishwashing liquid, using a soft cloth or sponge, previously switching off the mains.
  • Use only the equipment delivered with the refrigerating device. · In case of damage, disconnect mains and call service.
  • The producer suggests training the personnel operating the device in the range of device operation, as well as in the range of basic issues of safety and hygiene of work.
  • Connect the device to the mains network equipped with an efficient equipotential switch system.
  • The compartment that is intended for cold storage of products shall be filled with products taken directly from a fridge compartment (+4 degrees).
  • Fridge – Do not fill it with products taken directly from a freezer compartment.
  • Do not keep the doors open if this is not necessary.
  • Do not store rotten products.
  • If necessary, dry the moisture that may appear on shelves or walls inside the appliance.
  • Check the temperature every day.
  • Fridge – Always store products in closed containers or wrapped in cling film. In this way, you can avoid ice building up or corrosion of the evaporator.
  • Store products so that enough ventilation is provided.
  • The products shall not be stored directly at the bottom of the fridge but on the shelves.
  • Furthermore, the products shall not be stored densely at the rear wall of the fridge, but there should always be a space left between the products and the wall, for the air to pass through.
  • The compartment that is intended for storage of frozen products should be filled with products taken directly from the freezer compartment (-18 degrees).
  • Freezer – Store products in packing appropriate for freezing.

Note! It is particularly important to cover the food that contains lots of salt or acid when storing it in the fridge compartment.
CONTROL PANEL: DISPLAY

VIBOCOLD OSC 140S Convenience køler med Self Service front - Fig
1

BUT NO. FUNCTION NORMAL OPERATION ON-OFF FLASH STARTUP
1 compressor 1/2 on off
2 fan on off
3 defrost on nff
4 auxiliary output (AUX] – light output active output nut active
5 rincic [RTC] RTC is available I enabled [tEN=1] and at least one-time hand
has been set RTC not available or not enabler  tEN=0] or no time band set

011[if the clock is   itted]
6| alarm| alarm in progress| no alarm in progress| –| ON
7| digits| three digits with a decimal point and range – 199 to 999. See parameters 4/5/6 for the type of probe displayed. values n C/F and decimal point..

CONTROL PANEL: KEYPAD

BUT NO. NORMAL OPERATION STARTUP
1 inure then 3s; switch ON/OFF light (I-11 =4) or  defrost pressed together

with 3 activates .1 deactivates the  continuous cycle or defrost [see par1-15]| –
2| – Is: displays / sets the set point – more than 3s:  accesses the parameter setting menu [enter  password  2) mutes the audible alarm [buzzer)| –| pressed together [2 and3) activate parameter reset procedure
3| more than Rs: activates / deactivates light [1-11=4]  r defrost| pressed together with 1 Activates .1 deactivates the  continuities cycle or defrost [see por1-16]| ON

All controls are coded during the delivery of the appliance. This code is necessary to adjust the settings. The desired value can be adjusted by <LSE; HSE> without typing the code. The code and parameters LSE, and HSE can be found on the parameter list.
Temperatures – Fridge
The products will have a temperature between 0 and +4 °C if, during its installation, the panel is set to the value within the range 0 and +4 °C. The fridge is automatically defrosted every four hours, cooling well every 4 hours (details – see Control unit documentation in section 3 of the Service manual). During automatic defrosting, the LED diode is permanently on.
Temperatures – Freezer
The products will have a temperature between -18 and -22 °C if, during its installation, the panel is set to the value within the range of -18 and -22 °C. The freezer is automatically defrosted every four hours (details – see Control unit documentation in section 3 of the Service manual). During automatic defrosting, the LED diode is permanently on.
Cleaning
Before commencing any maintenance or cleaning activities, switch the device off, and then remove the plug from the power outlet!!! All repairs and maintenance should be performed by authorized personnel only. You should absolutely protect yourself against accidentally switching the device on by unaware persons.
Usage
How often the appliance needs to be cleaned depends on how frequently it is used and what types of products are usually stored in there.
Detergents
Dry the appliance on the inside and outside. Use a neutral detergent. If you use another detergent, finish the cleaning with a neutral one.
The following detergents are not to be used:
– detergents that contain chloride
– detergents that contain hypochlorite
– detergents for polishing silver
– see also the next point Products with PMMA details During cleaning of the details made of PMMA material, only a mild soap solution may be used.
The warranty does not cover the usage of other detergents. Amount of water Avoids using too much water because the electrical components could be damaged. It is strictly forbidden to shower the water directly on the outside or inside of the appliance.
Condensers
should be cleaned at least once every three months or even more often if the appliance is used under dusty conditions. Before cleaning, the power supply should be switched off and the plug should be pulled out of the wall socket.
During cleaning
A hoover or a soft brush may be used. If the condenser is brushed, make sure that the aluminum disks will not be damaged. Drip slides Check that the drip slide drain pipe is not clogged with dirt or dust. How often this must be done depends on how frequently the appliance is used. Cooling compartment In case of daily usage the inside of the cooling compartment shall be cleaned at least once a week, otherwise, there is a risk that acids or salts may damage the inside of the appliance. 2.6. Service While servicing the appliance and the showcases, the cable cord shall be pulled out. The transformer’s power supply is connected in such a way that it does not break after turning off the appliance using the switch.

Technical info

DIMENSIONAL PROPERTIES 1.0 1.
LENGTH WITHOUT END-WALLS mm 594
MIGHT mm 1365
 DEPTH mm 755
WALL THICKNESS mm 28
HORIZONTAL DISPLAY AREA) m2 1,6
NET VOLUME’) Terri 220
TDA (TOTAL DISMAY AREA 2) m2 0,95
MAX SHELF LOAD Kim
MAX HANGING SHELF LOAD kg/m1 15
WEIGHT kg
NOISE LEVEL dB (A) 60

VIBOCOLD OSC 140S Convenience køler med Self Service front - Fig
5

Proper exploitation rules of the refrigeration device

  1. Connect the device only do the zeroed mains outlet.
  2. Place the device in a proper distance from the wall, as described in the operating instruction.
  3. Do not cover intake and outlet holes in the aggregate chamber, serving the circulation of air cooling the condenser.
  4. Provide operating refrigeration device with the environment temperature in the following ranges: +15 to +25 ºC
  5. Place the device in a dry and drafty room (recommended relative humidity +55%).
  6. Periodically, make the condensate outflow channels permeable by cleaning the trays and troughs.
  7. In devices with no automatic defrosting, do a manual defrosting when the layer of frost on the evaporator exceeds 0.5 cm.
  8. You should unconditionally dust the condenser fins in the aggregate chamber to provide free airflow, at least every three months.
  9. Do not exceed the chamber load capacity of the refrigeration device given in the operating instructions.
  10. Observe the other suggestions and recommendations given in operating instruction.

ATTENTION !! Non-observance of the suggestions given above may result in non-reaching the assumed parameters, like desired temperature, bedewing of windows or external housing, water overflow from drip tray, and even compressor damage. These failures cannot be claimed by virtue of warranty.

Service Manual

Control panel – technical information:
Set point setting (desired temperature value)
The easy, easy compact, and easy split devices control the desired temperature (set point) inside the cabinet or cold room directly and dynamically. To view and modify the set point:
– Press SET for 1s, and the set value will start flashing;
– increase or decrease the value using UP or DOWN;
– Press SET to confirm the new value.
Manual defrost
 Not available on the easy thermometer (M) and easy compact models. Press DOWN for more than 3s (activated only if the temperature conditions are right, for easy split only if the light output is not set, H1=4). Alternatively, on easy split models, if the light output is set (H1=4), the defrost can be activated by pressing UP and DOWN together, when (H6=1).
Electrical chart

VIBOCOLD OSC 140S Convenience køler med Self Service front - Fig
6

Description Parameter Value
Regulation set point Set 65
nipping differential diF 0.,1
Maximum value settable for set point HSE 80
Minimum value settable for set point LSE 0
ON time for compressor output with the faulty regulation probe Ont 1
OFF time for compressor output with the faulty regulation probe Oft 0
Compressor output enabling delay from request dOn 0
Compressor output enabling delay from shutdown DOF 0
The delay between two consecutive starts of the compressor output dbi 0
Delay output enabling from Power On Od0 0
Type of defrosting to 0
interval between defrosts dit 0
Counting mode for defrost interval dCt 0
Defrost cyde enablig delay from request dOH 1
Defrost timeout dEt 0
Defrost end temperature dSt I
Defrost enabling request from Power On dP0 0
Parameter mode FSt (absolute or relative) FPt 0
evaporator fans disabling temperature FSt 2
Evaporator fans enabling differential Fad 110
Evaporator fans delay after defrosting cycle Fdt 50
 Dripping time dt 1
Evaporator fans disabling during defrost time dFd 0
--- --- ---
Eva porator fans status with OFF compressor output FCO 0
Evaporator fans status with open door Fod 0
Mode of parameter HAL and LAL (absolute or relative) An 3
Alarm tripping differential AFd 0
Maximo alarm threshold HAL 0
Mininun alarm threshold LAL 1
Alarm disabling after Power On PAO 0
Temperature alarm disabling time after defrost cycle dA0 0
Alarm signaling delay after digital input disabling 0A0 I
Alarm activation delay the time to open the door. td0 0
Temperature alarm signal delay time tA0 1
Alarm for defrosting ended due to a time out tA0 0
Loads shutdown enabling after door micro enabling dOd 1
Enabling delay of digital inputs dAd 0
Offset on set point OSP 0
Device address dEA 0
Family address FAA 0
Enable keyboard lock LOC 0
value of password 1 PSI 0
Value of password 2 PS2 0
Display with a decimal point ndt 0
Probe 1 calibration CA1 15
Probe 2 calibration CA2 1
Resource locking after defrosting end SSL -2
°C/7 selection dro 0
--- --- ---
Display main status ddd 0
Standby operatingmode I–108 30
Configurability and polarity of digital input 1-111 0
DOWN button configurability H32 1
Evaporator probe present H42 0

The above list consists of recommended parameters of device operation. In view of different working conditions, changes are possible to be introduced after prior contact with the device producer. Changing parameters without contacting the device producer may cause incorrect work or even device damage nd in consequence you may lose your warranty.

The manufacturer reserves the right to change the parameters of the device and introduce different technical solutions. The information contained in this document may be changed by the manufacturer without notice to the user. Copying this manual without permission is prohibited. Pictures and drawings are for illustration only and may differ from your device

VIBOCOLD A/S
Holstebrovej 101
DK-8800 Viborg
Service
Tel. +45 8750 3419
[email protected]

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

VIBOCOLD User Manuals

Related Manuals