Fantini cosmi C820RQ Dual Power Room Thermostat
Product Information
- Product Name: C820RQ
- Model: ITA TERMOSTATO AMBIENTE A DOPPIA ALIMENTAZIONE
- Installation and User Manual: pdf.fantinicosmi.it
- Power Supply: 230 V – 50 Hz, 2 AA alkaline batteries (1.5 V)
- Battery Life: > 1 year
- Power Consumption: 1 W
- Temperature Scale: Celsius
- Max Power Absorption: 5(3)A 230 Vca
- Disconnecting Capacity: 1 B.U.
- Nominal Conductor Section for Flexible Cables: 0.5 to 1 mm2
- Minimum Differential Adjustment: 4 K/h
- Maximum Ambient Temperature: [value]
- Storage Temperature: [value]
- Software: Class A
- Insulation Class: Class II
- Protection Degree: IP32
- Pollution Degree: 2
- Mounting: Wall or on a flush-mounted box type 500-502-503
- Dimensions: 98 x 98 x 20 mm (square base), 125 x 98 x 20 mm (rectangular base)
- Weight: 0.100 kg
- Compliance with Standards: EN 60730-1 and second parts; Directive 2014/30/EU (EMC); Directive 2014/35/EU (LVD); ErP
- Classification: ErP Class IV, 2% (Reg. EU 811/2013 – 813/2013).
Product manufactured in Italy.
Product Usage Instructions
Installation and maintenance operations should be performed with the electrical power of the system turned off and by qualified personnel, in compliance with the current regulations.
Wall Mounting
To proceed with the mounting, separate the front cover from the base by
pressing the button located on the lower edge of the cover and releasing the
device body upwards as shown in the figure.
Installation on Flush-Mounted Boxes
[Instructions for installation on flush-mounted boxes]
Connection to the System
Installation and maintenance operations should be performed with the
electrical power of the system turned off and by qualified personnel, in
compliance with the current regulations.
DUAL-POWER ROOM THERMOSTAT
- Dear customer, thank you for purchasing the Fantini Cosmi digital room thermostat, model C820RQ, for temperature management and home comfort.
- This manual contains all the information required for a correct installation and configuration.
- You can also download this manual in digital format and in several languages by framing the QR code below and entering the product code.
Package contents
- Thermostat C820RQ
- Rectangular base
- Manual
Warnings
Carefully read the installation instructions, safety warnings, operating
modes and maintenance instructions in this booklet, which should be kept for
further reference.
- After removing the packaging, check the integrity of the appliance; if in doubt, do not use it.
- Installation of the appliance should only be carried out by qualified technicians in compliance with current standards.
- The use of any electrical appliance involves observing certain basic rules. In particular:
- DO NOT touch the device with wet hands or wet feet or bare feet.
- DO NOT expose the device to the weather (rain, sun, etc.).
- Before carrying out any maintenance or cleaning work, switch off the power supply.
- DO NOT power the appliance with the cover open.
TECHNICAL DATA
Product manufactured in Italy.
INSTALLATION
Installation and maintenance operations must be carried out with the system’s electrical power switched off and by qualified personnel, in compliance with the regulations in force.
WALL MOUNTING
For optimal operation of the appliance, it is recommended that the thermostat be installed at a height of approx. 1.5 mt above the floor, in a suitable position to correctly detect the room temperature (see example in the drawing).
To proceed with the installation, separate the front cover from the base by pressing the button on the bottom edge of the cover and releasing the body of the unit upwards, as shown in the figure.
WALL MOUNTING
The tabs on the back of the base must be removed for the wall mounting. In
this way the thermostat will fit tightly against the wall.
ON FLUSH-MOUNTING BOXES
The thermostat is supplied with a square and rectangular base to allow the
installation on a flush-mounting box type 500-502-503.
CONNECTION TO THE SYSTEM
Installation and maintenance operations must be carried out with the system’s electrical power switched off and by qualified personnel, in compliance with the regulations in force.
By unscrewing the screw and lowering the plastic cover, as shown in the drawing, you will have access to the electrical connections.
Connect terminals 1 and 4 to the system.
- 4: Normally open contact
- 2: Normally closed contact
- 1: Common
POWER SUPPLY
230V – 50Hz
Connect terminals L-N to the 230V power supply.
BATTERIES
- To power the device with batteries, use 2 AA 1.5V alkaline batteries.
- Insert the batteries in the battery compartment at the rear of the device, observing the indicated polarities.
Notes:
- If the device is powered at 230V, we recommend not to insert the batteries.
- When using the device powered by batteries, several advanced functions will not be selectable.
LOW BATTERY WARNING
- 1 blink per minute with display in Stand-by mode: the batteries are running low and it is still possible to operate the device, but they must be replaced.
- Fast flashing with display in Stand-by mode: The batteries are flat; the device can no longer be operated and will go into OFF mode.
The batteries can be replaced at any time without losing the stored settings.
USE
DISPLAY ACTIVATION AND ROOM TEMPERATURE DISPLAY
- When the thermostat is in Stand-by mode, the display is off.
- Slightly pressing the central MODE button for 1 second, the screen activates and displays the room temperature. If the system is switched off, OFF will be displayed.
OPERATING MODE
- (COMFORT) for a setting adapted to the moments you spend at home.
- (ECONOMY) for a more energy-saving adjustment, e.g. during the night or when you are away for short periods of time.
- OFF: (OFF) to switch off the system when you are away for long periods.
The saving of changes is confirmed by the last displayed parameter flashing once and by the MODE button lighting up green . After saving, the display will return to Stand-by mode.
CHANGING THE DESIRED TEMPERATURE
By pressing the UP or DOWN arrows, the desired temperature value (Set Point)
of the current operating mode can be changed. The value is increased or
decreased in steps of 0.1°C.
The saving of changes is confirmed by the last displayed parameter flashing once and by the MODE button lighting up green . After saving, the display will return to Stand-by mode.
CHANGING THE BASIC SETTINGS (USER MENU)
To change several basic settings and optimize the display use, you can access the User Menu:
The saving of changes is confirmed by the last displayed parameter flashing once and by the MODE button lighting up green . After saving, the display will return to Stand-by mode.
BASIC SETTINGS MENU
Password (Pw)
- In order to prevent other users from changing the thermostat settings, a password can be entered to lock the buttons.
- To enable this function, choose an access code with a value from 1 to 999. This code must be entered, followed by the MODE button, to access any thermostat setting from the temperature control to basic or advanced parameters.
- To disable the key lock, set the value to “0”.
Stand-by (LF)
You can change the Stand-by activation time.
- Default value = 5
- 5 ÷ 10 sec
- ON = Display always on (*)
- (*) Regulation only available for systems powered by a 230V power supply.
Display light intensity (L1)
To improve the visibility of the LEDs in the room or to soften their light
intensity level, the default value can be changed.
- Default value = 5
- 1 ÷ 10
Temperature correction (0F5)
If the thermostat is close to heat sources or cold current areas, it is
possible to correct the measured temperature value.
- Default value = 0°C
- -4.0°C ÷ +4.0°C
Season (5ER)
Change the season to activate the control in heating or cooling mode. When the
system is switched on during the winter season, the central LED flashes red ,
while it flashes blue when the system is switched on during the summer season.
- Default value = WI
- WI = Winter (Heating)
- SU = Summer (Cooling)
Firmware (Fw)
On this screen, you can see the firmware release version.
ADVANCED FUNCTIONS
To change other thermostat settings, you can access the Advanced Functions menu:
- Changes to the values of parameters P01 to P16 should be made by competent and qualified personnel.
The saving of changes is confirmed by the last displayed parameter flashing once and by the MODE button lighting up green . After saving, the display will return to Stand-by mode.
ADVANCED FUNCTIONS MENU
SET POINT LIMITS
The desired temperature range can be limited by the user (Set Point).
Antifreeze function (P05)
This function avoids system blockage due to possible pipe freezing during the
winter period.
- Default value = 5.0°C
- OFF = off
- 2.0°C – 7.0°C
Data displayed on the Home page (P06)
- Default value = 1
- 1 = Room temperature
- 2 = Set Point active
Adjustment function (P07)
ON/OFF
During the ON/OFF adjustment the thermostat switches on (ON) when the measured
room temperature is below/above the desired temperature value (Set Point), and
switches off (OFF) when the desired temperature is reached. In this adjustment
mode, the Optimisation function (P08) can be activated and the Static
Differential value (P09) can be set.
TPI
If the thermostat is powered by a 230V power supply, it is possible to take
advantage of the special TPI algorithm which, by taking into account
parameters such as the room temperature, the energy class of the flat (P12),
the type of emission terminal (P13), the proportional band (P15) and the
control period (P14), optimises the system runtimes for a more constant
comfort level, ensuring optimal energy savings.
- Default value = 1
- 1 = ON/OFF adjustment
- 2 = TPI adjustment (*)
- (*) Regulation only available for systems powered by a 230V power supply.`
Optimization (P08)
When the thermostat is set to the ON/OFF adjustment, this function allows
minimising the energy consumption of the heating/cooling system by adjusting
its on/off times according to the installed type of system and the set
differential.
- Default value = OFF
- OFF = Function disabled
- ON = Function active (*)
- (*) Function only available for the ON/OFF adjustment.
Static differential (P09)
By selecting the ON/OFF adjustment, it is possible to set the value of the
static differential to manage the temperature difference between the OFF and
ON modes.
- Default value = Std
- Std = Standard
- 0.3°C ÷ 5°C (*)
- (*) Function only available for the ON/OFF adjustment.
Pump Anti-seizure (P10)
The Pump Anti-seizure function avoids limestone deposits during the system
shutdowns, resulting in short activation times of the pump after 24
consecutive hours of inactivity. The function is optional and can be enabled
by configuring the activation minutes of the circulating pump. Once enabled,
this function remains active even when the thermostat is in OFF mode.
- Default value = OFF
- OFF = function disabled
- 1 ÷ 10 min
Virtual relay (P11)
By enabling the virtual relay function, it is possible to display the activity
status of the system even when the display is switched off (Stand-by). When
the system is switched on during the winter season, the central LED flashes
red , while it flashes blue when the system is switched on during the summer
season.
- Default value = OFF
- OFF = Function disabled
- ON = Function enabled (*)
- (*) Regulation is only available for systems powered by a 230V power supply.
Energy class (P12)
When the TPI adjustment is active, it is necessary to set the energy class of
the building to enable the optimization of the system’s runtimes.
- Default parameter = A4
- A4, A3, A2, A1, B, C, D, E, F, G
- Function only available for TPI adjustment.
Type of emission terminals (P13)
If the TPI adjustment is activated, it is necessary to also set other related
parameters. The emission terminal identifies the final element of the
heating/cooling system. By setting the emission terminal, the values of the
Proportional Band and the Adjustment Period are automatically set (see the
below table); however, they can still be changed.
Emission terminal | Proportional band [°C] | Setting period [min] |
---|---|---|
Radiators | 0.5 | 15 |
Fan coil | 0.5 | 15 |
Floor | 1 | 30 |
- Default value = 1
- 1 = Radiators
- 2 = Fan Coil
- 3 = Floor
Function only available for TPI adjustment.
TPI Adjustment Period (P14)
The TPI Adjustment Period indicates the duration of a systemon + off cycle.
This period depends on the type of emission terminal. The values for the
Adjustment Period are set automatically by setting the emission terminal (see
Table P13); however, they can still be changed.
- Default value = 15
- 5 ÷ 60 min
Function only available for TPI adjustment.
TPI proportional band (P15)
The Proportional Band is the temperature range around the Set Point at which
TPI adjustment is active. Beyond this range, adjustment is of the ON/OFF type.
The values of the proportional band are set automatically by setting the
emission terminal (see Table P13); however, they can still be changed.
- Default value = 0.5°C
- 0.5°C – 2.0°C
Function only available for TPI adjustment.
Thermostat reset (P16)
After enabling the reset, the thermostat settings are restored to the default
values.
- Default value = NO
- NO = Reset disabled
- YES = Reset enabled
DISPOSAL
The symbol of the crossed-out wheeled bin indicates that the product must be collected and disposed of separately from household waste. Batteries and the integrated accumulators may be disposed of together with the product. They will be separated at the recycling facilities. A black bar indicates that the product was placed on the market after August 13th, 2005. Participating in the separate collection of products and batteries contributes to the correct disposal of these materials and therefore avoids possible negative consequences for the environment and human health. For more detailed information on the collection and recycling programs available in your country, contact the local authorities or the sales point where you purchased the product.
GENERAL WARRANTY CONDITIONS
The conventional warranty lasts 24 months, starting from the date the equipment is installed. The warranty covers all parts of the equipment, except those subject to normal wear and tear resulting from use.
FANTINI COSMI S.p.A.
Via dell’Osio, 6 – 20049 Caleppio di Settala, Milano – ITALY
- Tel. +39 02 956821
- info@fantinicosmi.it
- www.fantinicosmi.it