Blue-White Chem-Feed Plastic Skid Industrial
Introduction
Congratulations on purchasing the Chem-Feed® Engineered Plastic Skid System. The system is designed with the necessary components to safely inject liquid chemical into a system. Your Chem-Feed® Engineered Plastic Skid System is pre- configured based on your selections via the matrix or when designed with our engineering staff.
Please Note: Your new Chem-Feed® System has been pressure tested at the factory with clean water for a minimum of four hours before shipping. You may notice trace amounts of clean water in the system. This is part of our stringent quality assurance program at Blue-White Industries.
Features
Chem-Feed® Engineered Skid Systems were designed and engineered using solid modeling tools for superior piping installation and easy component maintenance. Custom engineered universal mounting blocks and pre-machined mounting slots provide for easy component servicing and replacement. Each factory built and tested system can include the following components:
- Pressure Relief Valve – Protects the system from over-pressurization, 5-150 psi setting range, 150 psi maximum system pressure. Ships on all systems.
- Check Valve – Protects the user from back-flow during pump maintenance. Ships on all systems.
- Flow Verification Sensor – S6A accurately verifies chemical feed. Exclusive to Blue-White®. (Optional)
- Inlet Y Strainer – Protects system components from damage cause by dirt or debris.
- Calibration Cylinder – Confirm pump output under system conditions. Specify cylinder volumes from 1.6 GPH to 64 GPH.
- Pulsation Dampener – Protect the system components from pulsation. Recommended for diaphragm pump systems. Not recommended for peristaltic pump systems. (Optional)
- Pressure Gage with Guard – Isolate and protect the system pressure gage. Specify pressure ranges from 0-30 psi, 0-100 psi, or 0-200 psi. (Optional)
- Pressure Switch with Guard – Activate or de-activate equipment when pressure in a piping system either rises or falls to a set pressure. (Optional)
- Back-Pressure Valve – Protects the user from siphon or back-flow, and maintains consistent pressure on pump. Typically used on diaphragm pump systems. (Optional)
- Terminal Box – Pump signal wiring is pre-wired to NEMA box for easy access and connection to facility wiring. (Optional)
- Electrical Outlet Box – Plug pumps into convenient weather resistant box.
- Mounting Pads – Stainless Steel mounting pads to secure Chem-Feed® System to a solid surface. Designed for floor mount or wall mount.
- Corrosion Resistant – Chem-Feed® frame constructed of chemically resistant polyethylene.
- Drip Tray – To collect chemicals and prevent spills.
- Single Skid Tray 2.2 Gal (8.4L)
- Dual Skid Tray 2.9 Gal (11.4L)
- Triplex Skid Tray 3.2 Gal (12.46L)
Specifications
Items listed below are standard available items and ship with most configurations. Your system may be customized with components not listed below.
Dimensions
Your Chem-Feed System may be designed differently from drawings below. However, the dimensions shown below remain the same no matter your configuration.
Single Pump System:
Duplex System:
Triplex System:
Mounting Pump to the Chem-Feed® System
Mounting the Chem-Feed® System
FLOOR MOUNT
- The Skid system is shipped with the mounting brackets ready for floor mounting. Mount the skid system to the floor using eight 1/4-20 Bolts (see fig. 1) through the mounting brackets.
WALL MOUNT
Remove the mounting brackets using a 1/4” wrench or socket. Install those
same mounting brackets in the vertical position on the sides of the skid
system. Mount the skid system to the wall using eight 1/4-20 Bolts (see fig.
2) through the mounting brackets.
Component Identification and Typical Operation – Single Pump Skid
Connections:
- Connect chemical solution into either Inlet 1 or inlet 2. (V-1 or V-2)
- Connect chemical treated system to outlet. (V-10)
To Pump chemical solution into system.
- Open ball valve V-1 or V-2, depending on your inlet side.
- Open ball valve V-3 and V-4.
- Close ball valve V-5, V-6, and V-9.
- Open ball valve V-10 to inject chemical solution into your system. Start pump.
To calibrate pump / system.
- Open ball valve V-1 or V-2, depending on your inlet side.
- Open ball valve V-3, V-4 , and V-6.
- Close ball valve V-5, V-9, and V-10.
- Start pump and run until calibration cylinder is filled to top calibration line. Do not leave pump unattended during this operation.
- Stop pump once calibration cylinder is filled.
- Close ball valves V-1, V-2, and V-6.
- Open ball valve V-5 and V-10 to inject chemical solution into your system.
- Note the chemical solution level in the calibration cylinder.
- To calibrate pump at maximum speed into your system, Press the prime button on pump. The prime mode runs the pump at maximum speed for 60 seconds (1 minute) on all Blue-White® ProSeries pumps.
- To calibrate pump at your desired feed rate, you must pre-program your pump speed before running this routine. Please refer to the instruction manual for your pump to adjust feed rate and additional calibration instructions.
Component Identification and Typical Operation – Duplex Pump Skid System
How To Operate the Chem-Feed® Duplex Skid System
Connections:
- Connect chemical solution into either Inlet 1 or inlet 2. (V-1 or V-2)
- Connect chemical treated system to outlet. (V-11)
To Pump chemical solution into system.
- Open ball valve V-1 or V-2, depending on your inlet side.
- Open ball valve V-3
- Close ball valve V-6, V-7, and V-11.
- Open ball valve V-4 and / or V-5. Depending on your system design. Open ball valve V-12 to inject chemical solution into your system.
- Start pump(s).
To calibrate pump(s) / system.
- Open ball valve V-1 or V-2, depending on your inlet side.
- Open ball valve V-3.
- Open ball valve V-4 or V-5, depending on which pump you’re calibrating.
- Close ball valve V-6, V-11, and V-12.
- Open ball valve V-7. This open valve will direct chemical into calibration cylinder.
- Start pump and run until calibration cylinder is filled to top calibration line. Do not leave pump unattended during this operation!
- Stop pump once calibration cylinder is filled.
- Close ball valves V-1, V-2, and V-7.
- Open ball valve V-4 or V-5, depending on which pump you’re calibrating.
- Open ball valve V-6 and V-12 to inject chemical solution into your system.
- Note the chemical solution level in the calibration cylinder.
- To calibrate pump at maximum speed into your system, Press the prime button on pump. The prime mode runs the pump at maximum speed for 60 seconds (1 minute) on all Blue-White® pumps.
- To calibrate pump at your desired feed rate, you must pre-program your pump speed before running this routine. Please refer to the instruction manual for your pump to adjust feed rate and additional calibration instructions.
Component Identification and Typical Operation – Triplex Pump Skid
Systemt
Connections:
Connect chemical solution into either Inlet 1 or inlet 2. (V-1 or V-2)
Connect chemical treated system to outlet. (V-11)
To Pump chemical solution into system.
Open ball valve V-1 or V-2, depending on your outlet side.
Open ball valve V-3, V-11, and V-15
Close ball valve V-5, V-13, and V-17.
Open ball valve V-10 and V-21 to inject chemical solution into your system.
Start pump P-1 and P-3.
To calibrate Pump 1
Open ball valve V-1 or V-2, depending on your inlet side
Open ball valve V-3 and V-4
Close ball valves V-5, V-7, V-10, V-13, V-14, V-17, V-20, and V-21
Open ball valve V-6. This open valve will direct chemical into calibration
cylinder
Start P-1 pump and run until calibration cylinder is filled to top calibration
line.
Do not leave pump unattended during this operation!
- Stop pump once calibration cylinder is filled.
- Close ball valves V-1, V-2, and V-6.
- Open ball valve V-5 and V-10.
- Note chemical solution level in the calibration cylinder.
- To calibrate pump at maximum speed into your system, Press the prime button on pump P-1. The prime mode runs the pump at maximum speed for 60 seconds (1 minute) on all Blue-White ProSeries pumps.
- To calibrate pump at your desired feed rate, you must pre-program your pump speed before running this routine.
- Please refer to the instruction manual for your pump to adjust feed rate and additional calibration instructions.
To calibrate pump 2
- Open ball valve V-1 or V-2, depending on your inlet side
- Open ball valve V-11 and V-12
- Close ball valves V-5, V-7, V-10, V-13, V-17, V-20, and V-21
- Open ball valve V-6 or V-14. Close the ball valve that was not chosen to be open.
- Open ball valve V-22 in the direction of the open ball valve V-6 or V-14. This open valve will direct chemical into calibration cylinder.
- Start P-2 pump and run until calibration cylinder is filled to top calibration line.
Do not leave pump unattended during this operation!
- Stop pump once calibration cylinder is filled.
- Close ball valves V-1, and V-2.
- Close the previously chosen ball valve V-6 or V-14.
- Open ball valve V-12
- Open ball valve V-22 in the direction of chemical outlet 1 or 2.
- Open ball V-10 if ball valve V-22 was set to flow to chemical outlet 1. Open ball valve V-21 if ball valve V-22 was set to flow to chemical outlet 2
- To calibrate pump at maximum speed into your system, Press the prime button on pump P-2. The prime mode runs the pump at maximum speed for 60 seconds (1 minute) on all Blue-White ProSeries pumps.
- To calibrate pump at your desired feed rate, you must pre-program your pump speed before running this routine.
- Please refer to the instruction manual for your pump to adjust feed rate and additional calibration instructions.
To calibrate pump 3
- Open ball valve V-1 or V-2, depending on your inlet side
- Open ball valve V-15 and V-16
- Close ball valves V-5, V-7, V-10, V-13, V-14, V-17, V-20, and V-21
- Open ball valve V-14. This open valve will direct chemical into calibration cylinder
- Start P-1 pump and run until calibration cylinder is filled to top calibration line.
Do not leave pump unattended during this operation!
- Stop pump once calibration cylinder is filled.
- Close ball valves V-1, V-2, and V-14.
- Open ball valve V-17 and V-21.
- Note chemical solution level in the calibration cylinder.
- To calibrate pump at maximum speed into your system, Press the prime button on pump P-3. The prime mode runs the pump at maximum speed for 60 seconds (1 minute) on all Blue-White ProSeries pumps.
- To calibrate pump at your desired feed rate, you must pre-program your pump speed before running this routine. Please refer to the instruction manual for your pump to adjust feed rate and additional calibration instructions.
WARRANTY
Limited Warranty
The pump is a quality product and is warranted for 24 months from date of
purchase (proof of purchase is required). The skid will be repaired or
replaced at our discretion. The pumps have a separate warranty and are not
covered under this warranty.
What is not Covered
- The pump(s). Refer to pump warranty page for information.
- Removal, or re-installation, and any related labor charge.
- Freight to the factory.
- Skids that have been tampered with, or in pieces.
- Damage to the skids that results from misuse, carelessness (such as chemical spills) on the enclosure, abuse, lack of maintenance, or alteration that is out of Blue-White’s control.
- Skids damaged by faulty wiring, power surges, or acts of nature.
Blue-White does not assume responsibility for any loss, damage, or expense directly or indirectly related to or arising out f the use of its products. Failure must have occurred due to defect in material or workmanship and not as a result of operation of the product other than in normal operation as defined in the pump operation manual. The warranty status is determined by the product serial label and the sales invoice or receipt. The serial label must be on the product and be legible. The warranty status of the skid will be verified by Blue-White or a factory authorized service center.
Obtaining In-Warranty Repair
Contact the factory to obtain a RMA (Return Material Authorization) number.
Carefully pack the system as instructed. Please enclose a brief description of
the problem as well as the original invoice or sales receipt, or copy showing
the date of purchase. Prepay all shipping costs. COD shipments will not be
accepted. Warranty service must be performed by the factory or an authorized
service center. Damage caused by improper packaging is the responsibility of
the sender. When In-Warranty repair or replacement is completed, the factory
pays for return shipping to the dealer or customer.
Product Use Warning
Blue-White products are manufactured to meet the highest quality standards in
the industry. Each product instruction manual includes a description of the
associated product warranty and provides the user with important safety
information. Purchasers, installers, and operators of Blue-White products
should take the time to inform themselves about the safe operation of these
products. In addition, Customers are expected to do their own due diligence
regarding which products and materials are best suited for their intended
applications. Blue-White is pleased to assist in this effort but does not
guarantee the suitability of any particular product for any specific
application as Blue-White does not have the same degree of familiarity with
the application that the customer/end user has. While Blue-White will honor
all of its product warranties according to their terms and conditions, Blue-
White shall only be obligated to repair or replace its defective parts or
products in accordance with the associated product warranties. BLUE-WHITE
SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR ANY LOSS OR DAMAGE
WHETHER DIRECT, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL, ARISING OUT OF OR
RELATED TO THE FAILURE OF ANY OF ITS PARTS OR PRODUCTS OR OF THEIR
NONSUITABILITY FOR A GIVEN PURPOSE OR APPLICATION.
Chemical Resistance Warning
Blue-White offers a wide variety of wetted parts. Purchasers, installers, and
operators of Blue-White products must be well informed and aware of the
precautions to be taken when injecting or measuring various chemicals,
especially those considered to be irritants, contaminants or hazardous.
Customers are expected to do their own due diligence regarding which products
and materials are best suited for their applications, particularly as it may
relate to the potential effects of certain chemicals on Blue-White products
and the potential for adverse chemical interactions. Blue-White tests its
products with water only. The chemical resistance information included in this
instruction manual was supplied to Blue-White by reputable sources, but Blue-
White is not able to vouch for the accuracy or completeness thereof. While
Blue-White will honor all of its product warranties according to their terms
and conditions, Blue-White shall only be obligated to repair or replace its
defective parts or products in accordance with the associated product
warranties. BLUE-WHITE SHALL NOT BE LIABLE EITHER IN TORT OR IN CONTRACT FOR
ANY LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL,
ARISING OUT OF OR RELATED TO THE USE OF CHEMICALS IN CONNECTION WITH ANY BLUE-
WHITE PRODUCTS.
Chem-Feed® Skid System Matrix
CHEM-FEED® Simplex Skid System Matrix – Industrial
CHEM-FEED® Duplex Skid System Matrix – Industrial
CHEM-FEED® Triplex Skid System Matrix – Industrial
Users of electrical and electronic equipment (EEE) with the WEEE marking per Annex IV of the WEEE Directive must not dispose of end of life EEE as unsorted municipal waste, but use the collection framework available to them for the return, recycle, recovery of WEEE and minimize any potential effects of EEE on the environment and human health due to the presence of hazardous substances. The WEEE marking applies only to countries within the European Union (EU) and Norway. Appliances are labeled in accordance with European Directive 2002/96/EC. Contact your local waste recovery agency for a Designated Collection Facility in your area.
- TEL: 714-893-8529
- FAX: 714-894-9492
- www.blue-white.com
- sales@blue-white.com
- customerservice@blue-white.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>