REEF FACTORY Smart Test Kit Magnesium User Guide
- June 13, 2024
- REEF FACTORY
Table of Contents
Magnesium
smart test kit
Allows approximately 60 tests within the range of 30 to 1500 mg/L
Contents of the test kit
Mg Reagent 1|
---|---
Mg Reagent 2|
Mg Reagent 1: Danger. Causes severe skin burns and eye damage.
IF ON SKIN (or hair): Take off immediately all contaminated clothing. Rinse
skin with water [or shower ].
IF IN EYES: Rinse cautiously with water for several minutes. Remove contact
lenses, if present and easy to do. Continue rinsing.
Contains: potassium hydroxide.
Mg Reagent 2: Danger.
Chart of results
X Rest ml in syringe
X ml| Magnesium(Mg)
mg/L (ppm)| X ml| Magnesium(Mg)
mg/L (ppm)| X ml| Magnesium(Mg)
mg/L (ppm)
---|---|---|---|---|---
0.98| 30| 0.64| 540| 0.30| 1050
0.96| 60| 0.62| 570| 0.28| 1080
0.94| 90| 0.60| 600| 0.26| 1110
0.92| 120| 0.58| 630| 0.24| 1140
0.90| 150| 0.56| 660| 0.22| 1170
0.88| 180| 0.54| 690| 0.20| 1200
0.86| 210| 0.52| 720| 0.18| 1230
0.84| 240| 0.50| 750| 0.16| 1260
0.82| 270| 0.48| 780| 0.14| 1290
0.80| 300| 0.46| 810| 0.12| 1320
0.78| 330| 0.44| 840| 0.10| 1350
0.76| 360| 0.42| 870| 0.08| 1380
0.74| 390| 0.40| 900| 0.06| 1410
0.72| 420| 0.38| 930| 0.04| 1440
0.70| 450| 0.36| 960| 0.02| 1470
0.68| 480| 0.34| 990| 0.00| 1500
0.66| 510| 0.32| 1020| |
1| Taking a seawater sample
Take 2 ml of water from the aquarium with a syringe and pour it into a test
vial.|
---|---|---
2| Adding Mg Reagent 1
Add 4 drops of Mg Reagent 1 liquid to the test vial and stir carefully in a
circular movement.|
3| Adding Mg Reagent 2
Shake the Mg Reagent 2 pipette, and then add 3 drops of liquid to the test
vial. Stir the solution carefully with circular motions. The liquid in the
test vial should turn pink.|
4a| Drawing Mg Reagent 3
Put the dispensing needle on a 1 ml syringe.|
4b| Drawing Mg Reagent 3
Draw 1 ml of Mg Reagent 3 liquid. The tip of the plunger should indicate
exactly 1 mi.
NOTE: the air between the fluid and the plunger does not affect validity
of the test.|
5| Dosing Mg Reagent 3
Using the syringe with the dispensing needle, drop by drop, add Mg Reagent 3
directly to the liquid in the vial so that there is no liquid left on the
walls.
After each drop, stir the vial and observe the color change.|
6| Transition and final colour
The pink solution will gradually begin to change color to a transitional color
– purple. When you notice, that the liquid has become intensely blue – stop
dripping.|
7| Reading and recording the result
Read the value of remaining Mg Reagnet 3 fluid in the syringe as indicated by
the syringe plunger. Compare it to the chart of results and/or enter it into
the user panel in Smart Reef.|
Store in a cool, dry, well-ventilated place in a tightly closed original packaging. In the temperature range of 5°C to 25°C. Avoid direct sunlight and heat sources. Keep the product away from children. Mg Smart test kit should be used up to 3 months of opening.
Read more:www.reeffactory.com