aspira 160 ASPIRVELO AIR RHINOCOMFORT RF
Product Information
The ASPIRVELO AIR RHINOCOMFORT RF is a single room heat recovery unit with air sanitation. It is designed to be installed on perimeter walls with a thickness ranging from 28 to 53 cm. The system includes a ceramic heat exchanger inside the unit that efficiently recovers heat from the extracted air and a G3 class filter that retains air impurities. The RHINOCOMFORT RF system also utilizes an LED light and water steam to decompose polluting substances in the air, making them harmless.
The system consists of a MASTER unit and optional Slave units for communication. The MASTER unit, along with its radio remote control, is required for installation. Up to 64 Slave units can be added for bidirectional communication with the MASTER unit.
The RHINOCOMFORT RF system operates using a low-power brushless motor controlled by a microprocessor. The microprocessor processes information from sensors on the unit (humidity, brightness, and temperature) and user commands from the remote control to optimize ventilation modes for indoor comfort. The remote control allows manual operating modes or automatic mode selection. Only the MASTER unit can detect air flow temperature.
Product Usage Instructions
To install and commission the ASPIRVELO AIR RHINOCOMFORT RF system, follow the instructions provided in the installation manual.
To use the system, refer to the USER MANUAL included in the package. It contains all the necessary information for consumers regarding system usage.
Note: The remote control and the MASTER unit are already paired, so no additional pairing is required.
This manual contains the information required for installing and commissioning the fan system. The information needed by consumers to use the system is shown in the USER MANUAL included in the package.
PRODUCT DESCRIPTION
The RHINOCOMFORT RF system consists of one or several decentralised, high- efficiency heat recovery fan units and air sanitation system to be installed on perimeter walls with a 28-53 cm thickness. The system is normally composed of:
- one radio-controlled RHINOCOMFORT 160 RF “MASTER” fan unit,
- one or several RHINOCOMFORT SAT 160 RF “Slave” fan units (optional)
The minimum requirements for installation are the “MASTER” unit and its radio
remote control to which a maximum of 64 “Slave” units communicating by radio
in a bidirectional manner with the MASTER unit can be added.
The fan unit operation is based on the regenerative heat recovery principle,
using a ceramic heat exchanger inside the device which accumulates the heat
released by the flow of air extracted from the room and then returns it
warming the air during the intake cycle. Any air impurities introduced are
retained by a G3 class filter.
Additionally, thanks to the combined action of an LED light that illuminates
the fan and the water steam contained in the air, RHINOCOMFORT RF decomposes
the polluting substances introduced present in the air, transforming them into
harmless substances.
The low-power brushless motor is controlled by a microprocessor which, by
processing the information of the sensors on the unit (humidity, brightness
and temperature) and the commands given by the user via the radio remote
control, adopts the most suitable ventilation modes for the best indoor
comfort.
If necessary, the remote control allows the user to choose one of the various
“manual” operating modes, or the “automatic” mode. Only the “MASTRER” unit can
detect the air flow temperature.
ATTENTION! The remote control and the master unit are already paired..
TECHNICAL DATA
GENERAL WARNINGS AND SAFETY INSTRUCTIONS
Carefully read the installation and maintenance instructions as well as the
safety warnings contained in this
Installation Manual, which should be carefully preserved for future reference
along with the User Manual.
- The unit should only be installed by qualified technicians, in compliance with current standards and interposing an all-pole switch with contact opening distance equal to or greater than 3 mm.
- The unit is intended to ventilate residential premises with heat recovery; different uses are not permitted and shall exempt the manufacturer from any responsibilities for the consequences resulting from improper use, as well as incorrect installation.
- After removing the packaging, check the product for integrity; if in doubt do not use it.
- The use of any electrical appliance implies the observance of some fundamental rules. In particular:
- DO NOT touch the appliance with wet hands, or wet or bare feet.
- DO NOT expose the unit to atmospheric agents (rain, sun, etc.).
- DO NOT touch the chrome fan in order not to decrease the air sanitising power
- Before performing any maintenance or cleaning, disconnect the unit from the mains power supply, opening the all-pole switch installed on the line.
- DO NOT power the appliance while the lid is open.
- The unit complies with 2014/30/EU and 2014/35/EU European Directives.
- Do not obstruct the air intake grille.
- In compliance with accident prevention regulations, ensure that the unit moving parts cannot be accessed after installation. If an appliance operating on gas (or other fuels) is installed in the room to be ventilated, make sure there is an adequate exchange of air to ensure the perfect combustion thereof and proper operation of the fan unit.
- Do not install an extractor fan in the same duct where the fumes of a gas appliance are conveyed.
- The unit can be installed only on a wall.
PACKAGE CONTENTS
- Fan unit
- Air diffuser
- Heat exchanger
- G3 filter
- Telescopic tube
- Inlet/outlet grille
- Remote control + 2 CR2032 batteries
- Dual-lock fastener
- Master identification label
- Installation manual
- End user manual
(*) Code AP19990 Unit MASTER only
FAN UNIT DIMENSIONS
INSTALLATION – WALL PREPARATION
Make a hole having a Ø162 mm minimum diameter and a 1÷3° slope towards the external environment, at a minimum height of 2.3 m from the floor and 100 mm from any side walls (Fig.1).
If two fan units are used on the same wall in the same room (Fig. 2a), keep a 1.2 m minimum distance between the centre of the cored holes. Should the units be mounted on two corner walls, the centres of the cored holes shall be respectively located 1.2 metres away from the opposite wall (Fig. 2b).
TELESCOPIC TUBE INSTALLATION
Pull the heat exchanger (2) out of the telescopic tube by grasping it by its handle (1).
- Apply cement mortar on the hole in the wall. Insert the telescopic tube with the larger diameter part (outer tube 4) towards the outside of the room, and place it flush with the outer wall.
- Run the inner tube (3) with respect to the outer tube (4) until it is flush with the wall of the room.
POSITIONING THE GRILLE AND HEAT EXCHANGER
Wait for the mortar to set and then place the “inlet-outlet” grille compressing the springs (7) on the outer tube (4) and permanently fix the grille.
- Insert the heat exchanger (2) until it is flush (8) with the inner tube.
FAN UNIT INSTALLATION
- Unhook the cover (A) from the motor support by pressing on the side holes (B) with a small screwdriver.
- Open the hole for the passage of the cable (D); in the case of non-buried external connections, open one of the recesses (C) best suited to the passage of the cable.
- Run the power supply cable into the appropriate hole (D) before proceeding to fasten the unit with the screws of the dowels previously prepared in the fixing holes (E).
- Place the power supply cable in the strain relief passage and connect the two L and N wires of the 230V ~ line as shown in the figure. The terminal block is of a quick coupling type; to insert the conductor press the corresponding tab.
- The unit complies with the double insulation rules. (Class II) and therefore does not require an earth cable.
- DO NOT touch the chrome fan in order not to decrease the air sanitising power
- DO NOT power the appliance while the lid is open.
FAN UNITS IDENTIFICATION
Units can be easily identified as only the MASTER unit has a temperature sensor.
- We suggest applying an identification sticker to the Unit MASTER cover.
ROTATION REPORT
RADIO REMOTE CONTROL SYMBOLS AND FUNCTIONS LEGEND
The description of all radio remote control features is provided in the USER
MANUAL; in any case, the legend is
also provided below along with the LED alerts specified in the installation
procedures.
FAN UNIT SETUP AND COMMISSIONING
ONLY QUALIFIED PERSONNEL CAN ATTEND THE PRODUCT WITH THE PURPOSE OF CARRYING
OUT THE OPERATIONS DESCRIBED IN THE INSTALLER MANUAL.
THE OPENING OF THIS APPLIANCE CAN MAKE DANGEROUS VOLTAGE PARTS ACCESSIBLE.
REMEMBER TO DISCONNECT THE NETWORK BEFORE TOUCHING ANY PART OF THE UNIT.
SLAVE UNIT (SAT) PAIRING PROCEDURE
IMPORTANT: complete the operation by keeping the remote control near (max
5 cm away) the SLAVE unit for the whole procedure The sequences 5a – 5b
(EXTRACTION mode selection) and 6a – 6b (INTAKE mode selection) shall be
performed alternatively with each other , according to the setting you want to
give to each single SLAVE unit.
It is recommended to set the first SLAVE unit to EXTRACTION mode, alternating
any other units in the system between INTAKE/EXTRACTION mode and reporting all
settings in the table on page 15.
- Press and hold the key until the entire LED sequence consisting of five slow flashes and three fast ones is ended.
- Bring the radio remote control close to the SLAVE unit and wait.
- The fan will run for a short time to confirm the successful outcome of the operation.
- The flashes of the first two LEDs alternate to the third LED flash.
- (only for units to be configured in the EXTRACTION mode) To select EXTRACTION mode in the alternating cycle operation, press and hold the EXTRACTION key until the fan runs.
- (only for units to be configured in the EXTRACTION mode) The LED fixed lighting confirms the EXTRACTION mode selection
- (only for units to be configured in the INTAKE mode) To select INTAKE mode in the alternating cycle operation, press and hold the INTAKE key until the fan runs.
- (only for units to be configured in the INTAKE mode) The LED fixed lighting confirms the INTAKE mode selection
- To confirm the mode selected, press and hold the ALTERNATING CYCLE MODE key until the fan stops.
- To acquire other SLAVE units, repeat steps 2 ÷ 8 and assign the INTAKE or EXTRACTION mode as appropriate according to the system requirements.
- To exit SLAVE acquisition mode, press and hold the POWER key until three fast LED flashes confirm the successful outcome of the operation.
SPECIAL OPERATIONS
ONLY QUALIFIED PERSONNEL CAN ATTEND THE PRODUCT WITH THE PURPOSE OF CARRYING
OUT THE OPERATIONS DESCRIBED IN THE INSTALLER MANUAL.
THE OPENING OF THIS APPLIANCE CAN MAKE DANGEROUS VOLTAGE PARTS ACCESSIBLE.
REMEMBER TO DISCONNECT THE NETWORK BEFORE TOUCHING ANY PART OF THE UNIT.
PROCEDURE TO UNLINK SLAVE UNITS (SAT) FROM THE MASTER UNIT
IMPORTANT: this operation must be carried out close to the MASTER unit.
- Press and hold the POWER key until the entire LED sequence consisting of five slow flashes and three fast ones is ended.
- To confirm the successful outcome of the operation, the LEDs will flash in sequence as indicated.
- Press and hold the “AUTOMATIC” MODE key until the entire LED sequence consisting of five slow flashes and three fast ones is ended.
PROCEDURE TO UNLINK THE MASTER UNIT FROM THE RADIO REMOTE CONTROL
IMPORTANT: This operation must be carried out only after unlinking the SLAVE unit
- Press and hold the POWER key until the entire LED sequence consisting of five slow flashes and three fast ones is ended
- To confirm the successful outcome of the operation, the LEDs will flash in sequence as indicated.
- Press and hold the “NIGHT” SPEED key until the entire LED sequence consisting of five slow flashes and three fast ones is ended.
PAIRING PROCEDURE BETWEEN MASTER UNIT AND RADIO REMOTE CONTROL
ATTENTION! The remote control and the master unit are already paired.
The procedure must be performed only when using a new remote control or in
case the master and the remote control were decoupled previously
- Insert batteries into the radio remote control.
- Bring the radio remote control close to the MASTER unit and wait.
- The fan will run for a few seconds to confirm the successful outcome of the operation.
PROCEDURE TO RESET A SLAVE UNIT (SAT) TO FACTORY CONFIGURATION
IMPORTANT: This operation must be carried out only after unlinking the SLAVE unit
- Press and hold the POWER key until the entire LED sequence consisting of five slow flashes and three fast ones is ended
- To confirm the successful outcome of the operation, the LEDs will flash in sequence as indicated.
- Press and hold the HIGH SPEED key until the entire LED sequence consisting of five slow flashes and three fast ones is ended.
REMOTE CONTROL BATTERIES INSERTION
Respect the indicated battery polarity
RADIO REMOTE CONTROL BATTERY REPLACEMENT WARNING
Three flashes every 5 seconds indicate the need for battery replacement.
MODE OF USE
The necessary information to users for the fan system daily use is shown in
the User Manual included in the package.
CLEANING AND MAINTENANCE
IMPORTANT NOTICE:
The filters must be cleaned by qualified technical personnel only, so it is
recommended to agree on a periodic cleaning programme with the user.
Before removing the cover (A) cut off the power to the unit.
To periodically clean the filters or replace them, proceed as follows:
For the front filter, release the cover (A) from the motor door by pressing on the side holes (B) with a small screwdriver and unscrew the four screws (G) to access the filter (H).
- FOR THE SECONDARY FILTER: remove the ceramic heat recovery unit from the pipe and release the filter;
- FILTER CLEANING: wash them in cold water and let them dry thoroughly before using them again
- PLASTIC PARTS CLEANING: After stopping the power supply circuit, clean dirty parts with water and some detergent using the utmost care.
- EXCHANGER CHECK: It is recommended to check soiling on a regular basis because it reduces efficiency. In case of need, remove it and wash it under running water.
SPARE PARTS
- AP19978 FR004 spare filter
- AP1984 FR007 spare filter
- 6306031 “Inlet/outlet” grille
- 6306032 Ceramic exchanger Ø160 mm
- 6306033 Telescopic tube Ø160 mm
- 6306022A Radio remote control
FAN SYSTEM SETUP TABLE
During installation, it is recommended to fill in the system summary table in order to keep track of the settings made and facilitate future maintenance.
DISPOSAL OF PRODUCTS
The crossed out wheeled dust bin symbol indicates that products must be
collected and disposed of separately from household waste. Integrated
batteries and accumulators can be disposed of with the product. They will be
separated at the recycling centres. The black bar indicates that the product
was placed on the market after August 13, 2005. By participating in separate
collection of products and batteries, you will help to assure the proper
disposal of products and batteries and thus help to prevent potential negative
consequences for the environment and human health. For more detailed
information about the collection and recycling programmes available in your
country, please contact your local city office or the shop where you purchased
the product
FANTINI COSMI SPA
Via dell’Osio, 6 – 20049 Caleppio di Settala MI, Italy
Ph. +39 02 956821 I Fax +39 02 95307006 I
info@fantinicosmi.it
SUPPORTO TECNICO
Tel. +39 02 95682278 I
supportotecnico@aspira.it
EXPORT DEPARTMENT
Ph +39 02 95682229 I export@fantinicosmi.it