QUFRESH BC80 CFM Ceiling Exhaust Bath Fan Instruction Manual

June 13, 2024
QuFRESH

QUFRESH BC80 CFM Ceiling Exhaust Bath Fan

QUFRESH-BC80-CFM-Ceiling-Exhaust-Bath-Fan-product

Product Information

The ventilation fan is designed to provide general ventilation in residential or commercial spaces. It helps remove stale air, odors, and moisture from the environment, improving indoor air quality.

Warnings:

  • Use this unit only as intended by the manufacturer. Contact the manufacturer for any questions or concerns.
  • Before servicing or cleaning the unit, switch off the power at the service panel and lock the service disconnecting.

Cautions:

  • This product is suitable for general ventilating use only. Do not use it to exhaust hazardous or explosive materials and vapors.
  • The product is designed for installation in ceilings with up to a 12/12 pitch (45 degree angle). The duct connector must point up. Do not mount it in a wall.
  • During construction or renovation, cover the fan to prevent plaster dust or any other construction residue from entering.
  • Avoid using combustible products such as acetone, alcohol, ether, or benzol near the fan as they are highly explosive.

Product Usage Instructions

Cleaning & Maintenance:

To preserve the appearance and performance of the ventilation fan, it should be cleaned regularly. Use a dusting brush attachment to gently vacuum both the exterior and interior of the fan to remove dust and debris.

Operation:

Follow the “Connect Electrical Wiring” instructions for proper electrical connection.

Installation Planning:

  • Do not use the ventilation fan in a cooking area.
  • There are two ways to connect ductwork to the factory-shipped unit.

Types of Typical Installations:

  1. Housing mounted to I-joists (Refer to Assembly Instructions 1)
  2. Housing mounted to joists (Refer to Assembly Instructions 1)
  3. Housing mounted to truss (Refer to Assembly Instructions 2)

Assembly Instructions:

  1. MOUNT HOUSING TO JOIST OR I-JOIST.
  2. Hold the housing so that it is in contact with the bottom of the joist.
  3. Attach the housing with four (4) screws to the joist through the holes in each mounting flange.
  4. Mount with mounting holes and hanger bar
  5. Slide one hanger bar into the channel on the housing and adjust as needed to fit between framing.
  6. Hold the housing in place so that it contacts the bottom of the joist. Screw the housing to the joist through the hole in the housing.
  7. Screw the hanger bar onto the other side of the joist through the hole.
  8. Screw the hanger bar to the housing with a screw. Refer to the diagram for clarity.
  9. Mount to I-joist
  10. Slide one hanger bar into the channel on the housing and adjust as needed.
  11. Hold the housing in place so that it contacts the bottom of the joist.
  12. Screw the housing to the joist through the hole in the housing.
  13. Screw the hanger bar onto the joist through the hole.
  14. Screw the hanger bar to the housing with a screw.
  15. Install DUCT AND BLOWER ASSEMBLY
  16. Install duct from the inside of the housing. Fix the duct by the tab.
  17. Fix the BLOWER ASSEMBLY to the housing using three screws.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:

  1. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer at the address or telephone number listed in the warranty.
  2. Before servicing or cleaning unit, switch power off at service panel and lock the service disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel.
  3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards.
  4. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  5. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities.
  6. Ducted fans must always be vented to the outdoors.
  7. Acceptable for use over a tub or shower when connected to a GFCI (Ground Fault Circuit Interrupter) -protected branch circuit (ceiling installation only).
  8. This unit must be grounded.

CAUTION

  1. For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors.
  2. This product is designed for installation in ceilings up to a 12/12 pitch (45 degree angle). Duct connector must point up. DO NOT MOUNT THIS PRODUCT IN A WALL.
  3. Do not let plaster dust or any other construction residue enter the fan. During construction or renovation, cover the fan.
  4. Combustible products used for cleaning such as acetone, alcohol, ether, or benzol are highly explosive and should never be used close to the fan.

CLEANING & MAINTENANCE

The ventilation fan should be cleaned regularly (internally and externally) to preserve its appearance and performance. Use a dusting brush attachment to gently vacuum the exterior and interior of the ventilation fan to remove dust and debris.

OPERATION

See “CONNECT ELECTRICAL WIRING” for details.

READ AND SAVE THESE INSTRUCTIONS Installer: Leave this manual with the homeowner.

PLAN THE INSTALLATION

  1. Do not use in a cooking area.
  2. Two ways to connect ductwork to a factory-shipped unit.QUFRESH-BC80-CFM-Ceiling-Exhaust-Bath-Fan-fig- \(1\)

TYPES OF TYPICAL INSTALLATIONS

  1. Housing mounted to I-joists (Start at “ASSEMBLY INSTRUCTIONS 1”)
  2. Housing mounted to joists (Start at “ASSEMBLY INSTRUCTIONS 1” )
  3. Housing mounted to truss (Start at step “ASSEMBLY INSTRUCTIONS 2”)

ASSEMBLY INSTRUCTIONS

  1. MOUNT HOUSING TO JOIST OR I-JOIST.
  2. Hold the housing so that it is in contact with the bottom of the joist.
  3. Attach the housing with four (4) screws to the joist through the holes in each mounting flange.
  4. Mount with mountion holes and hanger bar
  5. Slide one hanger bar into the channel on the housing and adjust as needed to fit between framing.
  6. Hold housing in place so that the housing contact the bottom of the joist, Screw housing to joist through the hole of the housing .
  7. Screw the hanger bar onto the other side of joist through the hole.
  8. Screw hanger bar to housing with screw.
  9. Refer to the right diagram.
  10. Mount to I-joist
  11. Slide one hanger bar into channel on the housing and adjust as needed.
  12. Hold housing in place so that the housing contacts the bottom of the joist.
  13. Screw housing to joist through the hole of the housing.
  14. Screw the hanger bar onto the joist through the hole.
  15. Screw hanger bar to housing with screw .
  16. Install DUCT AND BLOWER ASSEMBLY
  17. Install duct from the inside of the housing;Fix the duct by the tab.
  18. Fix the BLOWER ASSEMBLY to the housing by 3 screws.
  19. INSTALL ROUND DUCTWORK
  20. Connect the round ductwork (not included) to the damper/duct connector, and run the ductwork to a roof or wall cap (not included).
  21. Using tape (not included), secure all the ductwork connections so that they are air tight.
  22. Insulated flexible duct is recommended for the quietest possible installation. If rigid duct is used, a short (1-3 feet) section of insulated flexible duct will ensure quiet operation.

The ducting from this fan to the outside of building has a strong effect on the air flow, noise and energy use of the fan. Use the shortest, straightest duct routing possible for best performance, and avoid installing the fan with smaller ducts than recommended. Insulation around the ducts can reduce energy loss and inhibit mold growth. Fans installed with existing ducts may not achieve their rated air flow.

CONNECT ELECTRICAL WIRING

Run 120 V AC house wiring to the location of the fan. Use only UL-approved connectors (not included) to attach the house wiring to the wiring plate. Refer to the wiring diagram, and connect the wires as shown.QUFRESH-BC80
-CFM-Ceiling-Exhaust-Bath-Fan-fig- \(7\)

INSTALL GRILLE

  • Install ceiling material to complete the ceiling construction and cut around the fan housing.
  • To attach the grille assembly to the fan housing, pinch the grille springs on the sides of the grille assembly and position the grille into the housing with the grille springs in the appropriate slots. Push the grille assembly towards the ceiling to secure.

SERVICE PARTS

QUFRESH-BC80-CFM-Ceiling-Exhaust-Bath-Fan-fig-
\(9\)

WARNING : Ensure that the fan is switched off from the supply mains before replacing.

WARRANTY

  • QuFresh warrants this product to be free from defects in materials and workmanship for a period of one year from the date of purchase. Warranty does not apply to product which fails due to abuse, misuse, incorrect installation or improper maintenance. During the one-year warranty period, QuFresh will repair or replace, at its option, any product or part which has a factory defect in workmanship or materials.
  • The foregoing shall constitute our sole and exclusive warranty and our sole and exclusive liability, and is in lieu of any other warranties, whether written, oral, implied or statutory. Under no circumstances will QuFresh be liable for incidental or consequential damages occurring in connection with the use or performance of the product or other indirect damages with respect to loss of profits, revenue or property or cost of removal, installation or reinstallation.
  • Some jurisdictions do not allow the exclusion or limitation of incidental or consequential damages and some states do not allow limitations on how long an implied warranty lasts, so the above exclusions may not apply to you.
  • This warranty gives you specific legal rights and you may have other rights which vary from state to state and province to province.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals