Criseq AQSZB-110 Air Quality Sensor Instruction Manual

June 13, 2024
Criseq

Criseq AQSZB-110 Air Quality Sensor

Criseq-AQSZB-110-Air-Quality-Sensor-fig-7

AQSZB-110 Air Quality SensorProduct Information
The Air Quality Sensor is a device that monitors indoor air quality by continuously detecting volatile organic compounds (VOC) levels. It provides information on VOC levels to help prevent adverse health effects caused by unhealthy indoor air. By monitoring the air quality, the sensor ensures that the air inside the room is clean and healthy.

Placement
The Air Quality Sensor should be placed on the wall for optimal performance and easy access. It is recommended to mount the sensor at a height of 50 cm to 150 cm from the floor.

Installation

  1. Open the casing of the Air Quality Sensor by pushing the switch and pulling the top of the casing.
  2. Use double-sided tape or screws to attach the sensor to the wall.
  3. Insert batteries into the sensor, ensuring correct polarity.
  4. Make sure that the sensor has successfully joined a network before closing the casing.

Resetting
Resetting is required if you want to connect your Air Quality Sensor to another gateway or perform a factory reset to resolve any abnormal behavior.

  1. Open the casing of the sensor.
  2. Press and hold the round menu button inside the device.
  3. While holding the button down, observe the LED flashing once, then twice in a row, and finally numerous times in a row.
  4. Release the button when the LED is flashing numerous times in a row.
  5. After releasing the button, the LED will show one long flash, indicating that the reset is completed.

Disposal
Dispose of the Air Quality Sensor and batteries properly at the end of their lives. They are considered electronic waste and should be recycled.

VOC Levels

LEVEL VOC Range Hygienic Rating Recommendation
5 10,000 – 25,000 Unhealthy The situation is not acceptable. Intense

ventilation is necessary.
4| 3,000 – 10,000| Poor| Major objections. Intensified ventilation/airing
necessary.
3| 1,000 – 3,000| Moderate| Some objections. Intensified ventilation is recommended.
2| 300 – 1,000| Good| No relevant objections. Ventilation/airing is recommended.
1| < 300| Excellent| No objections. Target value.

IC Statement
This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two conditions: 1. This device may not cause interference. 2. This device must accept any interference, including interference that may cause undesired operation of the device. This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body.

CE Certification
The CE mark affixed to this product confirms its compliance with the European Directives applicable to the product, including harmonized standards and specifications.

Other Certifications

The Air Quality Sensor is Zigbee 3.0 certified. All rights reserved. Develco Products assumes no responsibility for any errors that may appear in this manual. Furthermore, Develco Products reserves the right to alter the hardware, software, and/or specifications detailed herein at any time without notice, and Develco Products does not make any commitment to update the information contained herein. All trademarks listed herein are owned by their respective owners.

Product Description

The Air Quality Sensor monitors indoor air quality through continuous detection of volatile organic compound (VOC) levels. The sensor provides information on the VOC levels, so adverse health effects caused by unhealthy indoor air can be prevented. By monitoring indoor air quality, the Air Quality Sensor helps you ensure that the air inside the room is clean and healthy

Precautions

  • Do not remove the product label as it contains important information.
  • Be aware that electronics are sensitive to static electricity, so aim to discharge before touching, and avoid touching any components inside the device.
  • Avoid placing the sensor close to radiators or electromagnetic fields.
  • Do not paint the sensor.
  • To ensure appropriate calibration, the sensor must be exposed to clean air for at least 10 minutes on a weekly basis.

Placement
PLACE THE SENSOR

  • Indoors at a temperature between 0-50°C.
  • Inside the room, in which you want to monitor VOC levels.
  • On a wall, where it is reachable for battery replacement and maintenance.

Mounting

Open the casing of the Air Quality Sensor by pushing the switch and pulling the top of the casing.

Use double-sided tape or screws to attach the sensor to the wall Insert batteries respecting the polarities. Make sure that the sensor has joined a network before closing the casing.

Connecting

  • When the batteries are inserted, the Air Quality Sensor will start searching (up to 15 minutes) for a Zigbee network to join.
  • Make sure that the Zigbee network is open for joining devices and will accept the sensor.
  • While the sensor is searching for a Zigbee network to join, the LED flashes red.
  • When the LED stops flashing, the sensor has successfully joined the Zigbee network.
  • If the scanning has timed out, a short press on the round menu button will restart it

Resetting
Resetting is needed if you want to connect your Air Quality Sensor to another gateway or if you need to perform a factory reset to avoid abnormal behavior.

STEPS FOR RESETTING

  1. Open the casing of the sensor.
  2. Press and hold the round menu button inside the device While you are holding the button down, the LED first flashes once, then two times in a row, and finally numerous times in a row.
  3. Release the button while the LED is flashing numerous times in a row.
  4. After you release the button, the LED shows one long flash, and the reset is completed

Fault finding & cleaning

  • In case of a bad or wireless weak signal, Change the location of the Air Quality Sensor. Otherwise, you can relocate your gateway or strengthen the signal with a smart plug.
  • If the search for a gateway has timed out, a short press on the button will restart it.

Battery replacement
The device will blink twice every minute when The battery is low.
CAUTION: Risk of explosion if batteries are replaced by an incorrect type. Dispose of the batteries in accordance with instructions.
CAUTION: When removing the cover for battery change – Electrostatic Discharge (ESD) can harm electronic components inside

  • Open the casing of the Air Quality Sensor to replace the batteries.
  • Replace the batteries respecting the polarities.
  • Close the casing of the sensor.

Disposal
Dispose of the product and batteries properly at the end of their lives. This is electronic waste that should be recycled.

VOC Levels

Criseq-AQSZB-110-Air-Quality-Sensor-fig-7

IC statement

This device contains license-exempt transmitter(s)/receiver(s) that comply with Innovation, Science, and Economic Development Canada’s license-exempt RSS(s). Operation is subject to the following two
conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the device. This equipment complies with IC RSS-102 radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with a minimum distance of 20 cm between the radiator and your body.

CE certification
The CE mark affixed to this product confirms its compliance with the European Directives which apply to the product and, in particular, its compliance with the harmonized standards and specifications

IN ACCORDANCE WITH THE DIRECTIVES

  • Radio Equipment Directive (RED) 2014/53/EU
  • RoHS Directive 2015/863/EU amending 2011/65/EU
  • REACH 1907/2006/EU + 2016/1688

Other certifications
Zigbee 3.0 certified

All rights reserved
Develco Products assumes no responsibility for any errors, which may appear in this manual. Furthermore, Develco Products reserves the right to alter the hardware, software, and/or specifications detailed
herein at any time without notice, and Develco Products does not make any commitment to update the information contained herein. All The trademarks listed herein are owned by their respective owners.
Distributed by Develco Products A/S Tangen 6 8200 Aarhus Denmark

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals