4homes 20296B Watt Meter with Cost Calculation User Manual

June 12, 2024
4homes

4homes 20296B Watt Meter with Cost Calculation

Product Information

  • Product Name: Watt Meter with Cost Calculation
  • Features: Measures voltage, current, frequency, power and calculates power consumption
  • Voltage Range: 180 – 250 V AC
  • Max Power: 3680 W
  • Consumption Range: 0.0 – 9999 W
  • Current Range: 0.000 – 16 A
  • Frequency Range: 47 – 63 Hz
  • Display Type: Monochrome LCD
  • Power Supply: AC 230 V, 50 – 60 Hz
  • Certified: No
  • Color: White
  • Material: Plastic
  • Size: 151 x 70 x 35 mm
  • Protection Class: IP20

Product Usage Instructions

  1. Read the user manual carefully and keep it for future reference.
  2. Follow the safety instructions:
    • Only connect devices to the product that comply with the specifications and do not exceed the maximum current consumption (16A).
    • Do not use more than one measuring device for the same socket.
    • Avoid exposing the product to extreme temperatures, pressure fluctuations, or direct sunlight.
    • Ensure that the device does not come into contact with moisture and do not install it in a bathroom or humid place.
    • Indoor use only.
    • Make sure the connected device does not cause more than the permissible load.
    • Do not leave electric heaters or radiators connected to the socket unattended.
    • Do not continue using the device if it is damaged. Repairs should only be carried out by an authorized specialist service.
    • People with reduced physical, sensory, or mental abilities, or children from the age of 8, can only use this device under supervision or with proper instructions.
    • Keep out of reach of children. The manufacturer and distributor shall not be liable for any damage resulting from improper use.
  3. First steps:
    • Insert the mains plug of the flow meter into the socket.
    • Check the time and minimum performance display on the screen.
  4. Device Parts:
  5. Display
  6. Mode button (Settings)
  7. COST button (To view the consumption cost)
  8. UP button (To increase value)
  9. DOWN button (To decrease value)
  10. RESET (Factory reset)
  11. Plug (230 V / ~50 Hz)
  12. Socket
  13. Ground contact (16A)

Watt meter with cost calculation

Legend

This flow meter helps you minimize costs and create an energy-efficient home. Measures voltage, current, frequency, power and calculates power consumption. The unit is able to determine the cost based on pre-set unit prices.

  • Child-proof socket
  • Built-in rechargeable battery so data is not lost even in a power failure
  • Cost calculation
  • Voltage, current, frequency measurement
  • Measuring time displayed in hours and minutes
  • Minimum and peak power display
Voltage range (min-max): 180 – 250 V AC
Max. power: 3680 W
Consumption range (min-max): 0.0 – 9999 W
Current range: 0.000 – 16 A
Frequency range: 47 – 63 Hz
Display type: Monochrome, LCD
Power supply: AC 230 V, 50 – 60 Hz
Certified: No
Accuracy: ± 2%
Color: White
Material: Plastic
Power supply in case of power failure: Built-in nickel rechargeable battery –

3.6 V
Size:| 151 x 70 x 35 mm
Operating temperature:| 0 – (+40)°C
Protection class:| IP20

User manual!
Thank you for choosing our product, we hope you will use it with great satisfaction for a long time.

IMPORTANT WARNING

  • Please read this user manual carefully and keep it for future reference.
  • Follow the safety instructions! Only connect devices to the product that comply with the specifications and do not exceed the maximum (16A) current consumption.
  • Do not use more than one measuring device for the same socket! Do not expose the product to extreme temperatures, pressure fluctuations or direct sunlight. Make sure that the device does not come into contact with moisture, do not install  the device in a bathroom or a humid place. Indoor use only! Make sure that the connected device does not cause more than the permissible load. Do not leave electric heaters or radiators connected to the socket unattended. It is forbidden to continue using the device if it is damaged! Repairs should only be carried out by an authorized specialist service. People who have reduced physical, sensory or mental abilities, or who lack experience and knowledge, and children from the age of 8 can only use this device if the supervision near, or they receive instructions on how to use it and understand the dangers arising from its use.

KEEP OUT OF REACH OF CHILDREN!

  • The manufacturer and distributor shall not be liable for any damage resulting from improper use.

Device parts

  1. Display
  2. Mode button (Settings)
  3. COST button (To view the consumption cost)
  4.  UP button (To increase value)
  5.  DOWN button(To decrease value)
  6. RESET (Factory reset)
  7. Plug (230 V / ~50 Hz)
  8. Socket
  9. Ground contact

First steps:
Insert the mains plug (7) of the flow meter into a 230 V/50 Hz and mains socketThe display (1) turns on and the text 00:00 appears in its upper part. This counter shows the time elapsed since the start of consumption. In the first minute, the elapsed time is shown in seconds, then the device switches to an hour and minute display. If no consumption is detected for 1 hour, the meter automatically resets the counter.

Displaying the measurement functions

By pressing the „Mode” button (2) one more time, you can switch between the display of individual measurement information:

  1. Time / Watt/cost display, in this case, the current performance is read. Under current consumption, the cost according to the preset unit price can be viewed.
  2. Time / kWh / Day display, in this case, the display shows the total consumption of the connected device in kWh. The lower part of the display shows the measurement duration (in days)
  3. Time/voltage/frequency display The middle part of the display shows the real-time instantaneous voltage, while the lower part of the display shows the real-time frequency in units of Hz.
  4. Time/amperage / power factor display during setting, the real-time current is displayed in ampere on the screen. In the lower part of the display, the power factor can be viewed on a scale of 0-1.
  5. Time / minimum performance display in the middle of the screen, the minimum Watt value is shown, while the abbreviation of „lo” i.e. Low can be seen at the bottom of the device.
  6. Time / Maximum power displayed, similarly to the display of the minimum value, in the middle of the disply, the measured maximum value is shown in watts, while at the bottom of the display you can see the abbreviation „hi”, i.e. High.
  7. Time / View cost: This menu is used to set the unit price of the electricity. The set unit price can be read in the lower part of the display (in currency unit/kWh)

Set unit price:
Use the MODE (2) button to navigate to the „Time / Price” (7) menu point as just mentioned, then briefly press the „COST” (3) button once. The currently set unit price is displayed at the bottom of the display, which can be changed by pressing the „COST” (3) button for at least 3 seconds. Then the characters starts flashing, indicating that the value can be edited. You can set the desired value using the „UP” (4) and „DOWN” (5) buttons. You can switch between individual characters by pressing the Mode (2) button. You can save the set value by pressing the „COST” (3) button!

Attention! „OVERLOAD” is displayed if the total load of the connected device/devices exceeds the maximum allowed value. (max. 3860 W) In this case, immediately disconnect the connected device from the electrical network!

Delete all data:

  • Press the RESET” button (6) with a pointed object to erase all data stored in the memory.
  • After successful deletion, all the digits on the display (1) light up for a few seconds.

Maintenance and care

  • It does not require special maintenance. Risk of electric shock! It is forbidden to disassemble the device housing, remove the screws or modify the device! Before cleaning the flow meter, unplug it from the mains socket and do not connect any devices to it. Clean the device only with a soft, clean, dry cloth.

Electronic waste management:
The used consumption measuring device must not be treated as household waste and thrown in the garbage. Electrical waste must be dropped off at a collection point! Ask your local authorities about the nearest collection point or the possibility of environmentally friendly disposal of the device.
www.delighttobuy.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

4homes User Manuals

Related Manuals