Numatic HVR170H-11 Commercial Dry Vacuum Instruction Manual

June 12, 2024
Numatic

Numatic HVR170H-11 Commercial Dry Vacuum
Numatic HVR170H-11 Commercial Dry Vacuum

Kit AS32 / AS0 / AS0 (270) (c/w 900918)

Kit

Assembly

Assembly

Using your machine

Using your machine
Using your machine
Using your machine

Cleaning

Cleaning
Cleaning

Replacing the Cartridge Filter

Replacing the Cartridge Filter
Replacing the Cartridge Filter

Replacing the Cartridge Filter

Wand Docking

Wand Docking

Fitting the Face

Fitting the Face

Removing the Face

Removing the Face

Data

| 1| 2| 3| 4| 5| 6
---|---|---|---|---|---|---
170| 7.2 L| 26.4 m| 8.2 kg| LpA ≤ 70 dB (A)| Class II| 360 mm x 370 mm x 390 mm
1| 2| 3| 4| 5| 6
---|---|---|---|---|---
Drum Size| Cleaning Range| Weight (Ready to work)| Sound Pressure| Protection Class| Dimensions

Schematic Diagram

Schematic Diagram

Replacement Parts

TriTex Filter

907073| TriTex Filter
Motor Filter
907044| H13 Post Motor Filter
HepaFlo Dust Bags
909291| NVH 1CH (Pack of 3)
907076| NVH 1CH (Pack of 5)
907075| NVH 1CH (Pack of 10)

Rating Label

1 Company Name & Address
2 Model
3 Voltage / Alternating Current
4 Frequency
5 Rated Input Power
6 Weight
7 WEEE Logo
8 Protection Class 2 Symbol
9 Approval Mark
10 Machine yr/wk Serial Number

About your machine (GB)

About your machine

Maintenance

Daily
Keep the machine clean, including hoses and tubes.
Ensure the bag and fi lter are fi tted.
Regularly examine the power cord.
Check dust bag frequently.
Check fi lters are clean.

Weekly – as daily and:-
Check for any worn or damaged parts and replace immediately

WEEE Legislation (Waste, Electrical and Electronic Equipment)
Vacuum cleaner, accessories and packaging should be sorted for environmentally – friendly recycling.
(Only for UK/EU Countries)
Do not dispose of vacuum cleaner into household waste! According to the European Directive 2012/19/EU on waste electrical and electronic equipment and its incorporation into national law.
Vacuum cleaners that are no longer suitable for use must be separately collected and sent for recovery in an environmentally – friendly manner.

PPE (personal protective equipment). That may be required for certain operations.

| | | |
Ear Protection| Safety Footwear| Head Protection| Safety Gloves
| | |
Eye Protection| Protective Clothing| Dust / Allergens Protection| Hi Viz Jacket| Caution Floor Sign
NOTE: A risk assessment should be conducted to determine which PPE should be worn.
Failure to rectify the problem or in the event of a breakdown contact your Numatic dealer or the Numatic Technical helpline +44 (0)1460 269268
Safety Critical Components

Mains leads: H05-V2V2-F 10m x 2 Core x 0.75 mm2

Information for DRY use Vacuum cleaners

WARNING
Read the instruction manual before using the machine.
Operators shall be adequately instructed on the use of their machine.
As with all electrical equipment, care and attention must be exercised at all times during use, in addition to ensuring that routine and preventative maintenance is carried out periodically to ensure safe operation.
Failure to carry out maintenance as necessary, including the replacement of parts to the correct standard could render this equipment unsafe and the manufacturer can accept no responsibility in this respect.
Maintenance should only be carried out by a qualifi ed person.
This machine is for DRY USE only and must not be stored outside or used in wet conditions.
The machine shall be disconnected from the mains power by removing the plug from the power supply socket during cleaning or maintenance and when replacing parts or converting the machine to another function.
Only use the socket outlet on the machine for purposes specifi ed in the instructions (if fi tted).
This machine is not to be used by children or persons with reduced physical, sensory or mental capabilities, or lack of experience or knowledge.
This appliance is intended to be cleaned and maintained by an adult.
Children being supervised are not to play with the machine.
This machine is not a toy.
This machine is not suitable for picking up hazardous or explosive dust.
Contact your local distributor if you require a machine capable of performing these tasks.

CAUTION
Ensure that the fi ltration system fi tted to the machine is suitable for the material being collected.
This vacuum cleaner is intended for indoor use in the collection of dry materials.
This machine should be stored indoors only.

NOTES
The primary use for this machine is commercial, for example in hotels, schools, hospitals, factories, shops and offi ces.
This product complies with the requirements of clause 20 of IEC/EN 60335-2-69 Stability and Mechanical Hazards.
This vacuum cleaner is fi tted with a thermal protection device. If the vacuum cleaner stops working, remove the plug from the wall before investigating where the fault lies.
If the vacuum cleaner has a blockage, switch off , remove the plug from the power socket, inspect the fl oor tool, tubes and hose for debris. If the fl oor tool, tubes and hose are clear, replace the dust bag and clean the fi lter.
The vacuum cleaner should be inspected after use for damage.
The vacuum cleaner should be stored in a dry place.
When moving from one place to another, consider the weight of the machine.

DO

  • Keep your machine clean including hoses and tubes.
  • Change dust bag frequently.
  • Keep filters clean.
  • Keep diff user filter (where fitted) clean.
  • Use filter bags, they will enhance performance and help keep machine clean.
  • Use a Numatic Original fi lter bag under fi ne dust conditions.
  • Keep hoses and tubes clear.
  • Replace any worn or damaged parts immediately.
  • Only use the brushes provided with the machine. The use of other brushes may impair safety.
  • Regularly examine the power cord. If damage is found such as cracking or ageing the power cord must be replaced by a qualifi ed person.
  • Only replace the power cord with the correct Numatic approved replacement part.

DO NOT

  • Pull on the cable to unplug the machine from the power supply.
  • Use to suck up hot ashes or lighted cigarette ends.
  • Use steam cleaners or pressure washers to clean the machine or use in the rain.
  • Immerse in water for cleaning.
  • Attempt machine maintenance or cleaning unless the power supply plug has been removed from the supply outlet.
  • Use in wet environments or to collect wet materials.
  • Under any circumstances place foreign objects including (but not limited to) air fresheners, air freshener capsules or scented beads of any type into the top fi lter of the machine. Doing so can be dangerous and risk damage to the machine and may invalidate the machine warranty.

We hereby confirm that the filter in this product conforms to H13: 99.95% (EN1822)
The unit as tested conforms to FED STD 209E Class 1000 (M4.5) classification and conforms to
BS EN ISO 14644-1 Class 6 Classification.
Maximum Total Particles equal to or larger than 0.5μm ≤ 35,300 / m³

WARRANTY

WARRANTY

UKCA Declaration of Conformity

UKCA Declaration of Conformity

Manufacturer:| Numatic International Limited Chard

Somerset TA20 2GB

www.numatic.co.uk

Product:| HVR, HVN, NVR, NSR, NVR, HET, NRV, EVR, HVX, HMR, HHR, HVC, HEC, HEP, HRP, HDK, HLX, PET, PEH, HRR, HVT, PCH, HPC
Description:| Vacuum Cleaner – Commercial – Dry
We, Numatic hereby declare under our sole responsibility, that the above- mentioned product(s) is/are in conformity with the following directives and standards.
S.I. 2008: 1597| Supply of Machinery Regulations| EN60335-1:2012 + AC:2014 + A11:2014 + A13:2017
EN60335-2-69:2012
EN62233:2008
---|---|---
S.I. 2016: 1091| EMC Regulations| EN55014-1:2017 + A11:2020
EN55014-2:1997 + A1:2001 + A2:2008
EN61000-3-2:2014
EN61000-3-3:2013
S.I. 2010: 2617| Ecodesign Requirements for Vacuum Cleaners| EN60312-1:2017
S.I. 2012: 3032| RoHS Regulations|

Authorised Signatory: Mr. Matthew Coles

Position: Head of Technology
Numatic International Limited,
Chard, Somerset, TA20 2GB, UK

Signed: Date: 1st Dec 2021

Declaration of Conformity


Manufacturer:| Numatic International Limited Chard

Somerset

TA20 2GB

www.numatic.co.uk

Product :| HVR, HVN, NVR, NSR, VNR, HET, NRV, EVR, HVX, HMR, HHR, HVC, HEC, HEP, HRP, HDK, HLX, PET, PEH, HRR, HVT, PCH, HPC
Description:| Vacuum Cleaner – Commercial – Dry
GB We, Numatic hereby declare under our
2006/42/EC| Machinery Directive| EN60335-1:2012 + AC:2014 + A11:2014 + A13:2017
EN60335-2-69:2012
EN62233:2008
---|---|---
2014/30/EU| EMC Directive| EN55014-1:2017 + A11:2020
EN55014-2:1997 + A1:2001 + A2:2008
EN61000-3-2:2014
EN61000-3-3:2013
2009/125/EC EU/666/2013| Ecodesign Requirements for Vacuum Cleaners|
2011/65/EU| RoHS Directive|

Authorised Signatory: Mr. Matthew Coles

Position: Head of Technology
Numatic International Limited
Chard,
Somerset, TA20 2GB, UK

Signed: Date: 04th May 2022

Customer Support

Numatic International Limited.
Chard, Somerset TA20 2GB ENGLAND
Tel: 01460 68600 www.numatic.co.uk

Numatic International GmbH.
Fränkische Straße 15–19. D-30455 Hannover,
DEUTSCHLAND Tel: 05 11 98 42 16 0 www.numatic.de

Numatic International SAS.
13 / 17 rue du Valengelier. EAE La Tuilerie – 77500 CHELLES,
FRANCE Tel: 01 64 72 61 61 www.numatic.fr

Numatic International BV.
Vennootsweg 15, 2404 CG, Alphen aan den Rijn, NEDERLAND
Tel: 0172 467 999 www.numatic.nl

Numatic International (Pty.) Ltd.
16th & Pharmaceutical Roads, Midrand, Gauteng,
SOUTH AFRICA 1685 Tel: 0861 686 284 www.numatic.co.za

Numatic International Schweiz AG.
Sihlbruggstrasse 3A, 6340 Baar. SCHWEIZ
Tel: 0041 (0) 41 76 80 76 – 0 www.numatic.ch

Numatic International ULDA.
Rua da Boa Viagem, 177. 4470.210 Maia. PORTUGAL
Tel: +351 220 047 700 www.numatic.pt

Numatic International SLU.
C/ La Forja, 41, 08840 Viladecans. (Barcelona), SPAIN
Tel: +34 93 647 22 22 www.numatic.es

Numatic International DENMARK.
Fränkische Straße 15–19. D-30455 Hannover,
DEUTSCHLAND Tel: 05 11 98 42 16 0 www.numatic-online.dk

Specification subject to change without prior notice www.numatic.com
© Numatic International Limited

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals