D-Link DIS-F200G Series 12-Port Gigabit Smart Managed Industrial PoE Switch Installation Guide
- June 12, 2024
- D-Link
Table of Contents
D-Link DIS-F200G Series 12-Port Gigabit Smart Managed Industrial PoE Switch
Installation Guide
DIS-F200G SERIES
Layer 2+ Gigabit Industrial Smart Managed PoE Switches with Long Reach PoE Ports
Before You Begin
This Quick Installation Guide gives you step-by-step instructions for setting up the DIS-F200G Series Layer 2+ Gigabit Industrial Smart Managed PoE Switch. The model you have purchased may appear slightly different from the one shown in the illustrations. For more detailed information about the Switch, please refer to the user manual.
Package Contents
This package should include the following items:
- DIS-F200G Series Switch
- Power terminal block
- Relay terminal block
- DIN rail mounts (installed)
- Quick Installation Guide
If any of the above items are damaged or missing, please contact your local D-Link Reseller.
HARDWARE OVERVIEW
LED Indicators
LED | Status | Description |
---|---|---|
**** P1, P2 | On | The corresponding power source is connected |
Off | The corresponding power source is not connected or failed | |
**** SYS | Flashing | The system is operating correctly |
Off or On | The system is not responding | |
**** ALM | On | Alarm has been triggered |
Off | No Alarm | |
**** F1, F2 | On or Flashing | SFP port connected and active |
Off | SFP port not connected |
HARDWARE INSTALLATION
Before You Begin
Observe the following precautions to help prevent shutdowns, equipment
failures, and personal injury:
- Install the DIS-F200G in a cool and dry place. Refer to the technical specifications in the user manual for the acceptable operating temperature and humidity ranges.
- Leave at least 10 cm of space at the top, rear and bottom of the Switch for ventilation.
- Visually inspect the power connector and make sure that it is fully secured to the power cord.
- Do not stack any devices on top of the Switch.
It is also recommended that power and grounding requirements are investigated before mounting the Switch.
Mounting the Switch on a DIN Rail
Before beginning either mounting or removing the DIS-F200G from a DIN rail,
please ensure that the DIN rail is level and that the DIN rail mounting kit is
installed correctly on the DIS-F200G. Use the following instructions to
install the DIS-F200G on a DIN rail:
- With the back of the DIS-F200G facing the DIN rail, lower the top part of the rail mounting kit onto the DIN rail.
- Push the DIS-F200G vertically down and rotate the bottom of the DIS-F200G towards the DIN rail, to attach the Switch to the DIN rail.
Use the following instructions to remove the DIS-F200G from a DIN rail:
- Push the DIS-F200G vertically down to create enough space at the bottom of the rail mounting kit to remove the DIS-F200G from the DIN rail.
- Rotate the DIS-F200G upwards to remove the bottom of the rail mounting kit from the rail, and lift the DIS-F200G upwards to remove the whole of the Switch from the DIN rail.
Grounding the Switch
To use the DIS-F200G safely, it needs to be grounded. Insert a grounding wire
into the terminal grounding connection and use a flat head screwdriver to
tighten the screw to secure the wire. Attach the other end of the grounding
cable to an appropriate grounding source.
Connecting to a Power Source
The DIS-F200G can be powered using the in-built terminal connector. This
allows dual power inputs, using wires from the power source(s) screwed-in to
the terminal connections.
Input voltage is 48 to 56V DC
The Switch offers built-in over current protection and power supply reverse connection protection.
Using the Terminal Connections
Before proceeding, ensure that all power sources have been disconnected from
the DIS-F200G, and that the power source you are wiring to the DIS-F200G is
also disconnected. Use the following instructions to power the DIS-F200G using
the terminal connections:
-
Before continuing, consult the diagram above to decide which wires from the power source need to connect to which contacts on the terminal block. Note that two power sources can be used; one inserted into -/+ (labelled PWR1) and the other inserted into -/+ (labelled PWR2). If you only wish to use one power source, insert the wires into -/+ (PWR1).
-
Using a flat head screwdriver, loosen the connections in the terminal block by un-screwing the terminal connections that you wish to use.
-
Insert the wires into the terminal connections and use the screwdriver to tighten the screws to secure the wires.
-
Re-insert the terminal block into the terminal block socket on the DIS-F200G
MANAGEMENT OPTIONS
The DIS-F200G can be managed by using the Web User Interface (Web UI), Console Port, Telnet, SSH, or Simple Network Management Protocol (SNMP).
For management, each Switch must be assigned its own IP address, which is used for communication with the management PC.
Web User Interface
Once the Switch has been successfully installed, you can begin configuration
and monitor Switch status using a web browser. Supported browsers include
Firefox, Chrome and Safari. You need the following equipment to access the Web
UI of your device:
- A PC with an RJ-45 Ethernet connection
- A standard Ethernet cable
-
Connect the Ethernet cable to any of the ports on the Switch’s front panel and to the Ethernet port on the PC.
-
Configure the PC’s IP address to be in the same network segment as the Switch. The Switch’s default IP address is 192.168.254.1, with subnet mask 255.255.255.0. For example, to connect to the Switch using the default settings, your PC should have an IP address in the range: 192.168.254.2-254 and a subnet mask of 255.255.255.0.
-
Open a web browser and enter http://192.168.254.1/ in the address box.
-
Log in to the switch. To do this, enter admin as the default user name and admin as default password. It is recommended to apply a secure strong password to “admin” account under System Settings > User Management.
Console
To connect to the Switch’s console, use a RS-232 serial to RJ-45 cable. A
terminal emulation program is required to connect to the console port on the
Switch. These are widely available and can be easily downloaded from the
Internet.
Using following steps to connect to Switch’s console port:
- Connect the RS-232 serial interface to the serial port of the management PC.
- Connect the RJ-45 interface to the console port of the Switch.
- Open a terminal emulation program on the management PC and configure the properties of the connection as follows:
- Speed: 115200 baud
- Data bits: 8
- Parity: None
- Stop bits: 1
- Flow Control: None
- Connect to the Switch and the Command Line Interface (CLI) should be available.
When prompted to log in, enter admin as the default user name and password.
Shortcut Buttons (DIP Switches)
Some Switch settings can be applied using the Shortcut Buttons (DIP Switches),
without the need to log into the Switch interface.
DIP Switch | Function when in ON position |
---|---|
AI Loop Protect | Enables detection of connection loops on the network, |
disables ports if detected, preventing broadcast storms.
AI PoE| Automatically restart a remote device by disabling and re-enabling PoE
on the port if it detects the remote device has locked up(no incoming
traffic).
AI VLAN| Isolates RJ45 ports from each other, suppress network storms and
improves network performance. Uplink SFP ports continue to communicate with
all ports.
AI Extend| Enables Long Reach PoE delivery up to 250m on PoE ports. Port speed
changes to 10Mbps (Cat 5 or better cabling is recommended).
Device Reset
If you have any problems accessing the DIS-F200G, it can be reset using the
following instructions:
Press and hold the reset button for 2 to 10 seconds. After releasing the button the SYS LED light will stop flashing and after a moment will start flashing rapidly indicating a restart.
After restart the DIS-F200G will be reset to factory defaults.
Additional Information
You can refer to the user manual or visit https://support.dlink.com.au/ for
more support.
SAFETY INSTRUCTIONS
The following general safety guidelines are provided to help ensure your own personal safety and protect your product from potential damage. Remember to consult the product user instructions for more details.
- Static electricity can be harmful to electronic components. Discharge static electricity from your body (i.e. touching grounded bare metal) before touching the product.
- Do not attempt to service the product and never disassemble the product. For some products with user replaceable battery, please read and follow the instructions in the user manual.
- Do not spill food or liquid on your product and never push any objects into the openings of your product.
- Do not use this product near water, areas with high humidity or condensation unless the product is specifically rated for outdoor application.
- Keep the product away from radiators and other heat sources.
- Always unplug the product from mains power before cleaning and use a dry lint free cloth only.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>