oasis aquatics Top Mount Fibreglass Media Filters Instruction Manual

June 12, 2024
oasis aquatics


oasis aquatics Top Mount Fibreglass Media FiltersOasis SFG Series
Top Mount Fibreglass MEDIA FILTERS
oasisaquatics.com.au
Part of the group
Head Office
6-8 Austral Place, Hallam VIC 3803 T: 03 9887 2131
New South Wales Unit 2,10 Boden Rd, Seven Hills NSW 2147
T: 02 9838 0000
Queensland
11 Andys Court Upper Coomera QLD 4209
T: 07 5679 6821
oasisaquatics.com.au 
sales@sunloverheating.com.au

Top Mount Fibreglass Media Filters

FOR QUICK REFERENCE, RECORDS YOUR DETAILS HERE.
Model No:
Serial No:
Purchase Date:
Installer:
Warranty Registered Online:
Yes / No

PRESSURE GAUGE READING RECORD

Initial Reading Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa
Date PSI kPa

IMPORTANT WARNINGS & SAFETY INSTRUCTIONS

IMPORTANT WARNINGS
This manual contains important information about the installation, operation and safe use of this product. This information should be given to the owner and/or operator of this equipment. When installing and using this equipment, basic safety precautions should always be followed. Failure to follow safety warnings and instructions in this manual can result in serious injury and/or damage to your equipment. Read and follow all warning notices and instructions which are included in this manual.
Pool and Spa water circulation systems operate under hazardous pressure during start up, normal operation, and after pump shut off. Stand clear of circulation system equipment during pump start-up. Failure to follow safety and  operation instructions could result in violent separation of the pump housing and cover, and/or filter housing and clamp due to pressure in the system, which could cause property damage, severe personal injury, or death.
Before servicing pool and spa water circulation systems, all system and pump controls must be in the off position and filter manual relief valve must be in open position. Before starting system pump, all system valves must be set in a position that allows system water to return back to the pool.
DO NOT CHANGE FILTER CONTROL VALVE POSITION WHILST SYSTEM PUMP IS OPERATING.
Before starting system pump, fully open filter manual air relief valve.
Do not close filter manual air relief valve until a steady stream of water (not air) is discharged.
Cleaning the media filter by BACKWASHING and RINSING is essential to providing clean, safe and healthy swimming water.
To reduce the risk of injury, DO NOT permit young children to use this product unless they have been trained by the person responsible for their safety and they acknowledge their ability to use such equipment. To reduce the risk of accidents or incidents, service on the unit should only be performed by your local pool Professional.
FAILURE TO FOLLOW INSTRUCTIONS CAN CAUSE SEVERE INJURY AND / OR DEATH.
CAREFUL REMINDERS

  • It is recommended that installation of all equipment is complete by a suitably qualified pool professional who will ensure your products are installed to your local standards / codes to ensure optimum safety and performance.
  • All components of the filtration system including Pumps, Filters, Heaters must be positioned so to prevent being used as means of access to the pool by young children. To reduce risk of injury, do not permit children to use or climb on this product. Closely supervise children at all times.
  • Make sure all wiring connections are clean and that all wiring and electrical equipment is in good condition. Damaged wiring must be repaired or replaced by a qualified electrician as soon as damage is discovered
  • Do not add chemicals directly to the pool skimmer. Adding undiluted chemicals may damage pump, heater, etc and void warranty
  • Pump suction is hazardous and can cause entrapment, drowning or disembowel bathers
  • Do not block or cover any pool/spa suction
  • Do not use or operate swimming pools, spas or spa baths if a suction cover is broken, missing or loose
  • Suction covers and inlets must be installed as per Australian Standards guideline and provided for every pump to avoid suction entrapment

GENERAL OVERVIEW

Congratulations on your recent purchase of your Oasis Aquatics SFG Top Mount Fibreglass Media Filter.
Please take a moment to read through the entire manual before installing your new unit.
While every effort has been made to ensure that the information contained in this guide is accurate and complete, no liability can be accepted for any errors or omissions.
Oasis Aquatics reserves the right to change the specification of the hardware and software described herein at any time without prior notice.
There are 5 different size models in our range:

SFG24-40 SFG24-50 SFG28-50 SFG31-50 SFG36-50
Link by Clamp Type Valves Link by Nut Type Valves

It is important that you read through the manual to identify the key areas you need to understand, particularly the following:

  • Health and Safety Concerns
  • Installation requirements
  • How to operate the major features of the unit
  • The importance of maintenance
  • If you have a problem, what to trouble shoot before you contact your pool service professional
  • Finally, your entitlements under your product warranty.

Oasis Aquatics have developed their product line to provide you with the ultimate experience and are sure you will be delighted with your purchase.
Please note: This manual has been designed to cater for installation rules and codes in Australia.
Specific rules and regulations for other countries may differ. Please speak with your installer should you have any questions.
Your filter is high performance and corrosion proof designed with superior flow characteristics that is easy to operate.
Everything is made simple from installation, operation, to the maintenance of the filter. Your Oasis Aquatics filter will provide crystal clear, healthy swimming water with minimal maintenance.
Oasis Aquatics highly recommends the use of qualified service technicians to ensure the best performance as well as the health and safety of your family.
Thank you again for choosing an Oasis Aquatics SFG Top Mount Fibreglass Media Filter.

HOW IT WORKS

Your Oasis Aquatics SFG Top Mount Fibreglass Media Filter is designed to use the high-quality filter elements such as Media or Glass to remove dirt particles from pool water. These elements are specifically designed for your Oasis  Aquatics Media Filter and if looked after will provide you with years of trouble-free operation.
The pool water which contains dirt particles is pumped through your system to the filter. As pool water passes through the filter, dirt particles will be caught by the filter element and removed from the water.
The cleaned pool water is returned back to the pool through your piping system. The entire process is continuous and automatic. It is this process that provides the filtration and removal of organic material such as dust, dirt and fine  particles in your pool water.
After a period of time, the accumulated dirt in the filter causes a resistance to flow, reducing the pressure in the tank and will reduce the flow of water through your filtration system. This means it is time to clean your filter.
A good indication when to clean the filter element is by checking the pressure gauge reading.
Cleaning should be performed when you notice the pressure has increased by 10 PSI or 70 kPa from when it was clean.
The cleaning procedure should be followed for best results.
YOU MUST ALWAYS TURN YOUR FILTER PUMP OFF BEFORE CHANGING THE MULTIPORT CONTROL VALVE POSITION.
FAILURE TO DO SO WILL CAUSE ACCELERATED WEAR AND / OR DAMAGE TO THE VALVE MECHANISM

INSTALLATION

The filter should be installed as close to the pool as possible but keep a distance of at least 1.5m.
Locate the filter on rigid, level surface, preferably in a dry, shaded, and well-ventilated area.
Prior to installation take into consideration the following conditions:

  • Position of suction and return PVC connections
  • Access for backwashing operation and servicing, including media replacement
  • Protection from sun, rain, splashing etc
  • Drainage of filter room
  • Ventilation and protection of the full filtration system
  • Media is loaded through the top opening of the filter
  • The overall weight of the filter once the media is added (some filters will exceed 250kg once loaded and settlement will occur if the mounting is not of sufficient construction).

Once you are happy that the above has been considered, follow these steps:

  1. Place the empty tank in position.
    a. Loosen the flange clamp and remove filter control valve (if previously installed).

  2. Cover the standpipe with the media fill cover. This will prevent any media from getting into the pipe and working its way into your pool.

  3. Fill the tank with water to the level that covers the laterals, or about 1/2 of the tank height. This helps protect the laterals from excessive shock by the force of the media when pouring into the filter.

  4. Position a corner of the filter media bag over the tank and carefully pour in correct amount and grade of filter media. Work slowly and carefully to prevent any media from spilling. Repeat until you have added the amount of filter media needed for your filter.

  5. The filter media surface should be levelled and should come to about the middle of the filter tank.

  6. Remove the media fill cover from the top of the stand pipe ensuring all filter media particles are removed from the valve mounting surface.

  7. Assemble the Multiport Control Valve into the filter tank by placing the O-ring into the groove on the tank.

  8. Lower the Control Valve into the tank neck, taking care that the centre pipe slips into the hole in the bottom of the valve. Rotate the valve until the inlet is approximately in line with the pump.

  9. Place the clamp set around the tank and the valve and tighten just enough so that the valve may be rotated on tank for final positioning.

  10. Carefully screw pressure gauge (with O-ring in place) into tapped hole in valve body. Do not over-tighten.

  11. Connect pump to control valve opening marked PUMP.

  12. After connections are made, tighten clamps with screwdriver. Tapping around the clamp with a rubber mallet or screwdriver handle will help seat the clamp.

  13. Make return to pool pipe connection to control valve opening marked RETURN and complete other necessary plumbing connections, suction lines to pump, waste, etc.

  14. Make electrical connections to pump per pump instructions.

  15. To prevent water leakage, make sure all pipe connections are tight.
    DO NOT OVER TIGHTEN.

WARNING
Is it important when connecting the WASTE line that you adhere to any local standards and codes in relation to the disposal of the waste water. It is also highly recommended to use minimum 40mm (1.5”) PVC Pipe with the SFG25-40 Filter and minimum 50mm (2.0”) PVC Pipe with all other SFG Filters.
To reduce any pressure and to provide the best clean possible, reduce the distance and amount of bends used for the WASTE discharge line. oasis
aquatics Top Mount Fibreglass Media Filters - Parts 1

To prevent water leakage, be sure all pipe connections are tight.
Prior to starting the filtration process by turning on the pump, we highly recommend that you read through the pump instruction manual to ensure proper installation and to avoid the risk of electric shock.

Start-Up Procedure

  1. Make sure the correct amount of filter media is located in the tank and all connections have been connected and secured.

  2. Press downward and rotate the Multiport Control Valve handle to the ‘BACKWASH’ position. To prevent damage to control valve seal, always depress handle before turning.

  3. Start the pump according to the pump instruction manual (be sure all suction and return lines are open), allowing the filter tank to fill with water.
    Once water is flowing steady out the waste line, run the pump for at least 2 minutes. The initial backwashing of the filter is recommended to remove any impurities or fine particles in the media.

  4. Turn the pump off and set the control valve to ‘RINSE’ position. Start the pump and operate until water in sight glass is clear, which will usually take approximately 1 minute. Turn pump off and set valve to ‘FILTER’ position and  restart pump. The filter is now operating in the normal filter mode, filtering dirt particles from the pool water.

  5. Adjust pool suction and return valves to achieve desired flow. Check system and filter for water leaks and tighten connections, bolts, nuts as required.

  6. Take note of the initial pressure gauge reading for future reference. Variation may occur from pool to pool.

NOTE THE INITIAL PRESSURE GAUGE READING WHEN THE FILTER IS CLEAN.
It will vary from pool to pool depending upon the pump and general piping system.
As the filter removes dirt and impurities from the pool water, the accumulation of dirt in the filter will cause the pressure to rise and diminish the water flow. When the pressure gauge reading is 10 PSI or
70kPa, higher than the initial “clean” pressure you noted, it is time to backwash the filter (see BACKWASH function).
NOTE: During the initial clean-up of the pool water, it may be necessary to backwash frequently due to the unusually heavy initial dirt load in the water.
IMPORTANT: To prevent unnecessary strain on piping system and control valve, always turn off the pump before changing the operation of the control valve. To prevent damage to the pump and filter and for proper operation of the  system, clean pump strainer (basket) and skimmer basket(s) regularly.

MULTIPORT CONTROL VALVE FUNCTIONS

The Multiport Control Valve controls the direction of water flow throughout your filter allowing you to easily filter your swimming pool water and then clean your filter tank. Correct operation of the Multiport Control Valve will give you  healthy, clean water for many years.

  1. FILTER
    Normal Filtration and Vacuuming
    This is the standard position when your filtration system is in normal operation. The water flows in from your pool and is distributed across the top of the media bed in the filter. Through pressure this water is pushed down through  the Media allowing debris to be removed from the water and collected in the media bed. Water is then taken up through the laterals and the centre stem pipe and returned to the pool, usually via some form of sanitation and/or heating. The filter position can also be used for manual vacuuming and cleaning of small debris.

  2. BACKWASH
    Cleaning filter by reversing the flow
    This position is used when the media bed requires cleaning. Use the Pressure Gauge to indicate when this is required, usually 10 PSI or 70 kPa above operation of a clean filter. When backwash is selected the water flow is reversed  and goes down the stem pipe and out through the laterals. This lifts the media bed and allows debris to be taken up the filter and out through the waste pipe. The sight glass will show the quality of the water and you need to backwash until this water is clear.

  3. WASTE
    By-passes filter, used for vacuuming to waste or lowering water level
    The waste position allows you to pump excess water from the pool directly down the waste pipe. This position is useful after heavy rains where the water level is too high. Water is directed straight through the Multiport Control Valve and bypasses the filter, going directly to waste. You can also use this position to vacuum heavy concentration of debris from the pool.

  4. RECIRCULATE
    By-passes filter for circulating water to pool
    Similar to the Waste setting, recirculate allows the water to bypass the filter but goes straight back to the pool. This is a useful setting if you have applied some chemicals that need to be circulated, but not removed by the filter. In addition, if a leak develops in the filter use recirculate to continue circulating water until it is fixed. The recirculate setting can also be used to assist with the re-priming of the filter pump, as bypassing the media bed reduces the  resistance in the pump return circuit.

  5. RINSE
    Used after backwash to flush dirt from valve
    Rinse is a very important setting to use after you have completed the Backwash cycle. In the rinse setting, water is taken from the pool and distributed on the media bed. This downward flow settles the media bed after backwashing  and carries any remaining loose dirt through to the waste line.
    By using Rinse after Backwashing you will eliminate any debris returning to the pool water. Rinse until you see clear water in the sight glass and should take half the time of a Backwash cycle.

  6. CLOSED
    Shuts off all flow to filter or pool
    Closed setting acts like a valve and prevents flow of water through the tank, particularly useful if doing any maintenance on the filtration system.

BACKWASHING

Cleaning your Filter will give you the best quality swimming water that is clean, clear and safe for swimming. It is highly recommended to clean on a regular basis and to monitor the pressure gauge and BACKWASH when an increase of  10 PSI or 70 kPa is indicated from your clean filter.
TO PERFORM THE BACKWASH OPERATION, YOU MUST FOLLOWING THESE STEPS:

  1. Turn off filter pump
  2. Change the position of the Multiport Control Valve handle from FILTER to BACKWASH
  3. Turn filter pump back on. The water flow is automatically reversed through the filter so the water is directed from the bottom of the tank, up through the media, flushing the trapped dirt and debris out of the waste line
  4. Check sight glass. The duration of the backwash operation will depend on how dirty your filter is. Continuously check the sight glass until the water becomes clear.
  5. Turn off filter pump
  6. Change the position of the Multiport Control Valve handle from BACKWASH to RINSE
  7. Turn filter pump back on. The water flow will now be directed back through the Media bed and then out through the waste line. This will settle the media bed back for normal operation
  8. Check sight glass. Continue until water is running clear
  9. Turn off filter pump
  10. Change the position of the Multiport Control Valve handle from RINSE to FILTER.
  11. Turn on filter pump

WARNING
YOU MUST ALWAYS TURN YOUR FILTER PUMP OFF BEFORE CHANGING THE MULTIPORT CONTROL VALVE POSITION.
FAILURE TO DO SO WILL CAUSE ACCELERATED WEAR AND/OR DAMAGE TO THE VALVE MECHANISM
Cleaning the Media Filter by BACKWASHING and RINSING is essential to providing clean, safe and healthy swimming water. A regular cleaning program is highly recommended especially in commercial applications, the time between  cleans and length of cleaning time will depend on size of pool, bather load and other environmental conditions. Discuss with your local pool professional to work out a program that best suits your pool.
WHEN VACUUMING THE POOL
If using your Manual Vacuum System to clean the pool. The following can be used as a guide for settings on your Multiport Control Valve.

  • Light Soil, general clean – set the control valve to FILTER position
  • Heavy Soil, specific clean – set the control valve to WASTE position. If using the WASTE position, ensure that the pool water level is well above your skimmer box level as the water will be directed down the waste line.

WINTERISING

Winterising is preparing your pool for freezing conditions which can potentially damage all pool filtration equipment due to water expanding when frozen. We highly recommend the following steps when preparing your filter for winter  conditions:

  1. Backwash the filter for at least thirty minutes before closing down the pool for winterising. This will clean the filter bed thoroughly and remove any debris from the system.
  2. Drain the filter tank by removing the drain cap at the base of the filter tank. Leave the cap off during winter.
  3. Set the control valve handle between the RINSE and FILTER. This will lift the handle and help with the draining process by allowing air to enter into the tank.
  4. Unscrew the pressure gauge from the control valve and store the gauge indoors.
  5. Drain and winterise the filter pump according to the manufacturer’s instructions.
    This is an ideal time for any repairs that may be required during the off- season. Most pool professionals will recommend want is needed before the next pool season.

SYSTEM TROUBLESHOOTING

If you suspect for any reason your Oasis Aquatics SFG Top Mount Fibreglass Media Filter is not performing or running as it should be, here are some handy troubleshooting tips that may assist you. This table should assist with the majority of problems

WHAT IS THE PROBLEM? POTENTIAL CAUSE?
Media Entering the Pool • Media too small and getting through laterals

• Flow rate on filter pump is too high and pushing media through laterals
• Media bed calcified due to poor water chemistry
• Broken lateral
• Loose centre-pipe
• Too much media in filter pump
• Multiport control valve not correctly in FILTER position
• Too much air in filter
Pool Water is Cloudy due to poor Filtering| • Media bed is dirty and requires backwashing
• Incorrect media has been installed
• Media bed is too low
• Algae build-up in filter due to poor water chemistry
• Excessive dirt in pool
• Calcified media bed due to poor water chemistry
• Heavy swimmer load
• Flow rate on filter pump is incorrect for filter size and pool size
• Backwashing cycle is too short
• Backwash line is too small restricting water flow
Media coming out of Waste Line| • Flow rate on filter pump is too high and lifting media too high on backwash
Filter Leaking Water| • Tank cracked
• Drain plug not tight
• Valve to tank o-ring damaged
Multiport Control Valve Leaks| • Handle is not properly located in selected setting
• Valve to tank o-ring damaged
• Valve cover o-ring damaged
• Pressure gauge o-ring damaged
Abnormal Loss of Pool Water| • Leak inside multiport control valve
• Leak from pool or PVC piping
High Pressure Filter| • Filter requires backwashing
• Calcified media bed due to poor water chemistry
• Return lines too small for flow rate of filter pump
Low Pressure in Filter| • Multiport control valve incorrectly set
• Filter pump flow rate is too slow, check speed and other
control valves
• Filter pump has lost prime

Oasis Aquatics highly recommends regular checks and maintenance of your swimming pool equipment by a qualified pool professional.
This will extend the life of your equipment and give you the best performance.
NOTE: If the recommendation in this manual does not solve your particular problem(s), please contact your local dealer for service.

POOL CHEMISTRY GUIDELINES

To get the best performance out of any of your pool equipment, it is important that you manage your water chemistry to the ideal swimming levels. This could vary according to your location and Oasis Aquatics highly recommend that you employ the services of your local pool professional to get your pool set-up to exactly what is required.
The below chart gives some guidelines to the major water chemistry areas to provide the best performance and to maximise your equipment life. Should your chemistry fall outside the suggested ranges, this could be damaging to the equipment and its performance.

IMPORTANT POOL CHEMISTRY LEVELS RANGE
pH 7.2 to 7.6
Total Alkalinity 100 to 130 ppm
Total Chlorine 1.0 to 3.0 ppm
Stabiliser (Cyanuric Acid) 40 to 70 ppm
Salt / Mineral Max 5,000 ppm

PRO-ACTIVE MAINTENANCE PROGRAM

Like your motor vehicle it is important to maintain a regular service program for your pool equipment to ensure the best operation and long lasting results.
The below chart provides a guideline to follow to best look after your valuable equipment. Regular maintenance can identify any potential issues early and save on expensive maintenance at a later date

WHEN? WHAT ARE YOU LOOKING FOR? HOW CAN YOU FIX?
Weekly Check Pressure Gauge If pressure increases by 10 PSI / 70 kPa, then

BACKWASH and RINSE the filter as per instructions.
Check around the unit for
leaves/debris or signs of flooding.| Remove any debris that is restricting air circulation around the filter.
If in a flood prone location, rectify
Quarterly| Check for any Insects or Ants| It is a good practice to use a good quality surface spray around your equipment.
Make sure all units are turned off and then spray around all units to eliminate any insect/ants etc
Check for any leaks| If you notice any water leaking from the filter or other equipment, check gaskets first  and reseal.
If leaking continues, contact your local pool professional to assess and rectify
Annually| Compare operating pressure of
backwashed filter to initial pressure
(when new)| If pressure after backwash is more than 40 kPa or 6 PSI different from new filter, a media change may be required.
Consult with pool professional for advice.

SPECIFICATIONS & DIMENSIONS

Model| Valve Port Size| Filtration Area| Design Flow| Height| Diameter| Media| Glass Fine| Glass Course
---|---|---|---|---|---|---|---|---
mm| m2| m3/h| A| B| Kgs| kgs| kgs
SFG25-40| 40| 0.32| 15.60| 950| 635| 145| 45| 60
SFG25-50| 50| 0.32| 16.32| 980| 635| 145| 45| 60
SFG28-50| 50| 0.41| 20.16| 1092| 723| 200| 60| 75
SFG32-50| 50| 0.50| 24.90| 1200| 800| 260| 75| 105
SFG36-50| 50| 0.64| 31.20| 1300| 900| 300| 75| 150

oasis aquatics Top Mount Fibreglass Media Filters -
DIMENSIONS

REPLACEMENT PARTS OF FILTER

SFG25-40
REPLACEMENT PARTS OF FILTER

Item Part No Description Qty
1 8280105 6 Way 1.5″ (40mm) Top Mount Valve (Valve Only) 1
2 89280101 1.5″ (40mm) union (Black) with sight glass with O-ring 1
3 89280102 1.5″ (40mm) union set with O-ring 2
4 06011029 Maximum 40PSI Indication, Stainless Steel Casing 1
4 E190109 Connector for Pressure Gauge/Stopper 1
5 89010119 M6*50 Screws with Nut 2
6 89010101 Clamp Lock 1
7 02011134 O-Ring for Filter Neck 1
8 89010110 SFG25-40 Filter tank 1
9 89010103 SFG25-40 Lateral Assembly with Center Pipe 1
10 01172008 Laterals (126mm) for SFG25-40 8
11 01111062 21-28″ Filter Base for SFG25-40 1
12 01181052 Fastener for Filter Base 4
13 89010107 Water Drain Set 1
14 01015006 Media Diverter (Black) for 1.5″ (40mm) 1

REPLACEMENT PARTS OF MULTIPORT VALVE

oasis aquatics Top Mount Fibreglass Media Filters -
VALVE

Item Part No Description Qty
1 01013003 Handle (Big) 1
2 03018008 Pin for Handle 1
3 01181001 Washer for Handle 1
4 89280107 M6 x 30 Screw with Nut for Standard Lid 6
5 01013154 1.5″ (40mm) Top/Side Mount Valve Standard Lid (Black) 1
6 02011002 O-Ring for 1.5″ (40mm) Valve Lid 1
7 01181002 Washer for Spring 1
8 03014001 Spring for 1.5″ (40mm) Top/Side Mount Valve 1
9 02011022 O-Ring for Valve Rotor 2
10 01021001 1.5″ (40mm) Valve Rotor 1
11 02311002 Spider Gasket 1
12 E190147 1.5″ (40mm) Body with Diffuser (Black) 1
13 02011001 O-Ring for Diffuser 1
14 02020013 O-Ring for 1.5″Connector 3
15 01013015 1.5″ (40mm) Connector (Black) 3
16 02011003 O-Ring for 1.5″ (40mm) Adaptor 3
17 01171153 1.5″ (40mm) Union (A/E) 2
18 01013017 1.5″ (40mm) Union Nut (Black) 3
19 01041002 1.5″ (40mm) Union with Sight Glass (Short) 1
20 01172026 1.5″ (40mm) Union with Sight Glass Holder 1
21 89280120 Connector for Pressure Gauge/Stopper 1
22 89021307 Drain Plug with O-ring 1
23 06011029 Oil Pressure Gauge with O-ring 1
24 919305061 MPV01/MPV03 Upper part 1

SFG25-50
REPLACEMENT PARTS OF FILTER

Item Part No Description Qty
1 01013003 Handle (Big) 1
2 03018008 Pin for Handle 1
3 01181027 Washer for Handle 1
4 01181028 Defend Lock 1
5 01020009 2.0″ (50mm) Lid 1
6 01181002 Washer for Spring 1
7 02011022 O-Ring for Valve Rotor 2
8 03014014 Spring for Valve 1
9 89280805 2.0″ (50mm) Valve Rotor with Spider Gasket 1
10 02010003 O-Ring for Lid 1
11 E190213 2.0″ (50mm) Body with Diffuser 1
12 89280120 Drain Plug Fitting with O-ring 1
13 89021307 Drain Plug with O-Ring 1
14 06011029 Oil Pressure Gauge with O-Ring (40Psi) 1
15 02020016 1.5″ Union Nut (Black) 6
16 01013031 2.0″ (50mm) Connector (Black) 3
17 01171154 2.0″ (50mm) Union (A/E) 3
18 01013032 2.0″ (50mm) Union Nut (Black) 3
19 89280104 Sight Glass with O-Ring 1
20 02011005 O-Ring for Diffuser 1
21 919301023 MPV08 Upper part 1

REPLACEMENT PARTS OF MULTIPORT VALVE

oasis aquatics Top Mount Fibreglass Media Filters -
MULTIPORT

Item Part No Description Qty
1 89010601 Nut with Washer 12
2 88280306 6 Way 2″ Top Mount Valve (Valve Only) 1
3 6011029 Maximum 40PSI Indication, Stainless Steel Casing 1
4 89280103 2″ union set with O-ring 3
5 89280104 Sight Glass with O-Ring 1
6 2011126 Filter Neck Gasket 1
7 89010612 SFG28-50 Filter Tank with Base 1
7 89010603 SFG32-50 Filter Tank with Base 1
7 89010604 SFG36-50 Filter Tank with Base 1
8 89010611 SFG28-50 Standpipe with Hub 1
8 89010607 SFG32-50 Standpipe with Hub 1
8 89010608 SFG36-50 Standpipe with Hub 1
9 1172010 Laterals (185mm) For SFG28-50 8
9 1172011 Laterals (233mm) For SFG32-50 & SFG36-50 8
10 89010107 Water Drain Set 1
11 1111062 21 – 28inch Filter Base For SFG28-50 1
11 1112038 32 – 40inch Filter Base For SFG32-50 & SFG36-50 1

REPLACEMENT PARTS OF FILTER

Item Part No Description Qty
1 89010601 Nut with Washer 12
2 88280306 6 Way 2″ Top Mount Valve (Valve Only) 1
3 6011029 Maximum 40PSI Indication, Stainless Steel Casing 1
4 89280103 2″ union set with O-ring 3
5 89280104 Sight Glass with O-Ring 1
6 2011126 Filter Neck Gasket 1
7 89010612 SFG28-50 Filter Tank with Base 1
7 89010603 SFG32-50 Filter Tank with Base 1
7 89010604 SFG36-50 Filter Tank with Base 1
8 89010611 SFG28-50 Standpipe with Hub 1
8 89010607 SFG32-50 Standpipe with Hub 1
8 89010608 SFG36-50 Standpipe with Hub 1
9 1172010 Laterals (185mm) For SFG28-50 8
9 1172011 Laterals (233mm) For SFG32-50 & SFG36-50 8
10 89010107 Water Drain Set 1
11 1111062 21 – 28inch Filter Base For SFG28-50 1
11 1112038 32 – 40inch Filter Base For SFG32-50 & SFG36-50 1

REPLACEMENT PARTS OF MULTIPORT VALVE

oasis aquatics Top Mount Fibreglass Media Filters - MULTIPORT
3

Item Part No Description Qty
1 1013003 Handle (Big) 1
2 3018008 Pin for Handle 1
3 1181027 Washer for Handle 1
4 E190144 M6 x 33 Screw with Nut 10
5 1013158 50mm Top Mount Valve Standard Lid (Black) 1
6 3014014 Spring for Valve 1
7 2011006 O-Ring for 50mm Top Mount Valve Lid 1
8 2011022 O-Ring for Valve Rotor 2
9 1181002 Washer for Spring 2
10 1021002 50mm Valve Rotor 1
11 2311003 Spider Gasket 1
12 E190220 50mm Body with Diffuser (Black) 1
13 2011005 O-Ring for Diffuser 1
14 2020016 O-Ring for Connector 6
15 1013031 50mm Connector (Black) 3
16 1171154 50mm Union (A/E) 3
17 1013032 50mm Union Nut (Black) 3
18 89280104 Sight Glass with O-Ring 1
19 89280120 Connector for Pressure Gauge/Stopper 1
20 89021307 Drain Plug with O-ring 1
21 6011029 Oil Pressure Gauge with O-ring 1
22 919301014 MPV02 Upper part 1

WARRANTY

Australian Consumer Law
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Your Oasis Aquatics SFG Top Mount Fibreglass Media Filter is covered by a limited five (5) year warranty and commences from the date of purchase.
Please refer below for details as follows:

  • 5 year limited warranty on Oasis Aquatics SFG Top Mount Fibreglass Media Filter unit against component failure or defects workmanship and materials excluding obvious neglect, misuse, improper installation or improper  maintenance from date of purchase.

  • 12 months limited warranty on multiport valve, internal components, including o-rings, gaskets and gauges unit against defects in workmanship and materials excluding obvious neglect, misuse, improper installation or improper  maintenance from date of purchase.

  • 12 months warranty is provided on installation labour completed by Oasis Aquatics or Sunlover Heating staff from date of install.

  • Items that are replaced as part of routine maintenance are not covered by this warranty.
    This warranty is subject to the conditions and limitations herein after stated and is applicable to workmanship and materials only.
    You must notify Oasis Aquatics of the failure of any component of your product within seven (7) days of the recognised fault.
    Oasis Aquatics will at its option, repair or replace any defective parts. Component failure must be due solely to a defect in materials or workmanship. The manufacturer will not be held liable for damage caused by, but not limited to,  corrosion, scaling or stress.
    This warranty does not apply if failure is due to any abuse, misuse, improper installation or accident or to any of the following:

  • The customer has not complied with Oasis Aquatics terms and conditions of sale

  • The product was used in an application for which it wasn’t intended

  • The product was altered, modified or repaired by any other person than Oasis Aquatics or its Authorised Service Agents

  • The product has not been installed, maintained or operated in accordance with installation and operating instructions

  • Environmental influences such as flooding, storm, lighting, fire

  • Running filtration system without water

  • Damage beyond our control

This Warranty is solely for the benefit of the original consumer and with respect to the original installation only. and is therefore non transferable under any circumstance.
Oasis Aquatics shall have no liability for incidental or consequential damages. No person is authorized to make any representation or warranty on behalf of Oasis Aquatics other than what is stated here.
If a defect in materials or workmanship occurs within the warranty period Oasis Aquatics will, at its discretion repair or replace product or the defective part of the product free of charge or cause the product or the defective part to be  repaired or replaced by an Authorised Oasis Aquatics Service Agent free of charge.
Oasis Aquatics reserves the right to substitute defective parts or the product with parts or product of similar quality, grade and performance where an identical part or product is not available. Parts or products may be replaced by  refurbished goods of the same type rather than be repaired.
If the product is bought as a demonstration, refurbished, ex-rental, discontinued or otherwise previously unboxed unit, the warranty applicable shall be limited to twelve (12) months only.
On Commercial Installations, such as health clubs, swim schools, motels/hotels and hydrotherapy, parts and in field labour warranty, the warranty period is limited to twelve (12) months only.

TECHNICAL SUPPORT

For all warranty enquiries please contact your local distributor or contact Oasis Aquatics directly and we will either direct you to your nearest authorised repairer or assist you.
OASIS AQUATICS
Ph: 1800 815 913
Website: oasisaquatics.com.au
Email: sales@sunloverheating.com.au

DISCLAIMER
Information in this guide is intended to provide general information on a particular subject(s) in good faith and is not an exhaustive treatment of such subject(s). Its use is beyond the control of the author, contributor, publishers and  distributors and should not be relied upon without consulting your local Professional for comprehensive advice.
This guide includes subject(s) that should only be performed by or under the direction and advice of your local Professional and under no circumstances should the guide be used as a substitute for such professionals.
No representations or warranties are made that the content, advice and recommendations in this guide are current, free from errors or omissions, or appropriate for the user’s circumstances or abilities. No liability or responsibility is  accepted for any loss suffered as a result of any user’s reliance on such content.

WARRANTY REGISTRATION

Registering your Oasis Aquatics products is fast and easy, providing peace of mind that you’ve got great backup support for the life of your pool heating!

****Victoria
6-8 Austral Place
Hallam VIC 3803
Australia
T: 03 9887 2131
New South Wales
Unit 2, 10 Boden Road
Seven Hills NSW 2147
Australia
T: 02 9838 0000
Queensland
11 Andys Court
Upper Coomera QLD 4209
Australia
T: 07 5679 6821
oasisaquatics.com.au
sales@sunloverheating.com.au

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals