Triangle Tube INSFS110S Instinct Solo Floor Standing Boiler Owner’s Manual
- June 12, 2024
- Triangle Tube
Table of Contents
Triangle Tube INSFS110S Instinct Solo Floor Standing Boiler
Product Information
- Product Name: Instinct Floor Standing 110 Solo
- Model Number: INSFS110S
- Input, MBH: 13.75 – 110
- Heating Net AFUE: 102
- Boiler Air Vent: 1
- Gas Connections: 3/4 inch
- Weight: 196 lbs
Instinct Floor Standing 110 Solo Features
- Heavy duty construction for floor standing installation
- Approved for zero clearance to combustibles
- 2” PVC, CPVC, PP venting up to 28 equivalent feet
- 3” PVC, CPVC, PP, or AL29-4C venting up to 100 equivalent feet
- Left or Right side optional boiler connections
- Left, Right, Top, or Back gas connections
- 10 year limited warranty on heat exchanger
- Up to 6 year limited warranty on parts, except igniter
- Up to 3 year labor allowance
Approvals
- 95% AFUE Efficiency
- ENERGY STAR Qualified
- ANSI Z21.13 and CSA 4.9 Boiler Standards Compliance
- ASME Boiler Certification – ASME “H” Stamp
- SCAQMD Rule 1146.2Low NOx Certification
CTRLMax Control System
- Graphical display with 5 navigation buttons
- EZ Setup allows quick and easy boiler settings adjustment
- Flexible configuration of 4 circulator outputs for custom applications
- Outdoor temperature reset to maximize efficiency
- Accepts two space heating call inputs with independent outdoor reset curves
- Domestic hot water priority with optional time-out
- Integrated cascade control for up to 6 Instinct boilers
- 0-10 VDC Modulation input
- Modbus building management system (BMS) interface, LonWorks® and BACnet® interface optional
- Adjustable warm weather shutdown
- Adjustable boiler freeze protection
- Logging function records sensor readings for system optimization and troubleshooting
- Describes lockouts in plain English and suggests solutions while storing last 8 errors
Standard Equipment
- Factory fitted remote Wifi monitoring
- Stainless steel premix burner
- Direct spark ignition with variable speed blower
- Full modulation with turndown ratio of 8:1
- Hydraulic Separator with dirt and air separation
- Automatic air vent
- ASME 30 PSI pressure relief valve
- Temperature and Pressure gauge
- Outdoor temperature sensor
- Automatic low water cutoff feature with early warning
- High temperature manual reset limit safety control
- Terminal block for circulator output
- Low voltage terminal strip with removable jumpers for manual or automatic reset limits
- Swing up control for easy access and servicing
- Polypropylene condensate pan and internal flue pipe
- 3 in 1 Universal vent adapter directly accepts PVC/CPVC, Polypropylene, Stainless steel connections with test ports
- Additional external 110V socket
Project / Location: _
Date: __
Consulting Engineer / Architect: ____
Mechanical Contractor: _
Boiler Dimensions
Instinct Floor Standing Boiler| ****
Details
---|---
Model Number| Input, MBH| Heating Capacity, MBH| Net AHRI
Rating, MBH
| AFUE| Boiler Connections| Air Inlet| Vent Outlet| Gas Connections| Shipping
Weight
Min| Max
INSFS110S| 13.75| 110| 102| 89| 95%| 1”| 3”| 3”| 3/4″| 196 lbs
- The Net AHRI Water Ratings shown are based on a piping and pickup allowance of 1.15.
- Triangle Tube should be consulted before selecting a boiler for installations having unusual piping and pickup requirements, such as intermittent system operation, extensive piping systems, etc.
- The ratings have been determined under the provisions governing forced draft burners.
Boiler Dimensions
Dimensions – In [mm]
A
| ****
B
| ****
C
| ****
D
| ****
E
| ****
F
| ****
G
| ****
H
| ****
J
| ****
K
| ****
L
| M, P, Q| ****
N
| ****
S
| ****
T
21 5/8”| 4”| 17 1/2”| 2 1/4″| 5 1/8”| 40 3/4”| 8 5/8| 12 5/8”| 30 3/8″| 7
3/4″| 6″| 2 5/8″| 8 1/2″| 2 1/2″| 21 5/8″
[550]| [101]| [445]| [58]| [130]| [1036]| [220]| [320]| [771]| [198]| [150]|