Before using your air conditioner, please read this manual carefully and keep it for future reference.
IMPORTANT SAFETY INSTRUCTIONS
READ THIS MANUAL
Inside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You’ll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.
To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. The seriousness is classified by the following indications.
WARNING
| This symbol indicates the possibility of death or serious injury.
---|---
CAUTION
| This symbol indicates the possibility of injury or damage to property.
| Never do this.| | Always do this.
WARNING
Plug in power plug proper1y.
- Otherwise, it may cause electric shock or fire due to excess heat generation.
Do not operate or stop the unit by inserting or pulling out the power plug.
- It may cause electric shock or fire due to heat generation
Do not damage or use an unspecified power cord.
- It may cause electric shock or fire.
- If the power cord is damaged, it must be replaced by the manufacturer or an authorised service centre or a similar1y
qualified per son in order to avoid a hazard.
Always install circuit breaker and a dedicated power circuit.
- Incorrect installation may cause fire and electric shock.
Do not operate with wet hands or in damp environment.
It may cause electric shock.
Do not direct airflow at room occupants only.
- This could damage your health.
Always ensure effective grounding.
- Incorrect grounding may cause electric shock.
Do not allow water to run into electric parts.
- It may cause failure of machine or electric shock.
Do not modify power cord length or share the outlet with other appliances.
- It may cause electric shock or fire due to heat generation.
Unplug the unit if strange sounds, smell, or smoke comes from it.
- It may cause fire and electric shock.
Do not use the socket if it is loose or damaged.
- It may cause fire and electric shock.
Do not open the unit during operation.
- It may cause electric shock.
Keep firearms away.
- It may cause fire.
Do not use the power cord close to heating appliances.
- It may cause fire and electric shock.
Do not use the power cord near flammable gas or combustibles, such as gasoline, benzene, thinner, etc.
- It may cause an explosion or fire.
Ventilate room before operating air conditioner if there is a gas leakage from another appliance.
- It may cause explosion, fire and, burns.
Do not disassemble or modify unit
- It may cause failure and electric shock
CAUTION
When the air fi8lter is to be removed, do not touch the metal parts of the unit
- It may cause injury
Do not put a pet or house plant where it will be exposed to direct air flow.
- This could injure the pet or plant
Ventilate the room when used together with a stove etc
- An oxygen shortage may occur.
Do not use strong detergent such as wax or thinner but a soft cloth
- Appearance may be deteriorated due to change of product color or scratching of its surface.
Do not clean the air conditioner with water.
- Water may enter the unit and degrade the insulation. It may cause an electric shock.
Do not use for special purpose
- Do not use this air conditioner to preserve precision devices, food, pets, plants, and art objects. It may cause deterioration of quality, etc.
Stop operation and close the window in storm or hurricane.
- Operation with windows opened may cause wetting of indoor and soaking of household furniture.
When the unit is to be cleaned, switch off, and turn off the circuit breaker.
- Do not clean unit when power is on as it may cause fire and electric shock, it may cause an injury.
Ensure that the installation bracket of the outdoor appliance is not damaged due to prolonged exposure.
- If bracket is damaged, there is concern of damage due to falling of unit.
Always insert the filters securely. Clean filter once every two weeks.
- Operation without filters may cause failure.
Hold the plug by the head of the power plug when taking it out.
- It may cause electric shock and damage.
Turn off the main power switch when not using the unit for a long time.
- It may cause failure of product or fire
Do not place obstacles around air-inlets or inside of air-outlet.
- It may cause failure of appliance or accident.
Do not place heavy object on the power cord and ensure that the cord is not compressed.
- There is danger of fire or electric shock.
Do not drink water drained from air conditioner.
- It contains contaminants and could make you sick.
Use caution when unpacking and installing . Sharp edges could cause injury.
If water enters the unit, turn the unit off at the power outlet and switch off the circuit breaker. Isolate supply by taking the power-plug out and contact a qualified service technician.
CAUTION
- This appliance is not intended for use by persons (including children) with reduced physical ,sensory or mental capabilities or lack of experience and knowledge. unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety.
- Children should be supervised to ensure that they do not play with the appliance.
- If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard.
- The appliance shall be installed in accordance with national wiring regulations.
- Do not operate your air conditioner in a wet room such as a bathroom or laundry room.
- The appliance with electric heater shall have at least 1 meter space to the combustible materials.
- Contact the authorised service technician for repair or maintenance of this unit.
- Contact the authorised installer for installation of this unit.
IMPORTANT SAFETY INSTRUCTIONS
NOTE:
The power supply cord with this air conditioner contains a current detection device designed to reduce the risk of fire. Please refer to the section Operation of Current Device for details. In the event that the power supply cord is damaged, it cannot be repaired-it must be replaced with a cord from the Product Manufacturer.
WARNING
Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord.
Grounding type wall receptacle
Do not, under any circumstances, cut, remove, or bypass the grounding prong.
Power supply cord with 3-prong grounding plug and current detection device
WARNING
For Your Safety
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
WARNING
Prevent Accidents
To reduce the risk of fire, electrical shock, or injury to persons when using your air conditioner, follow basic precautions, including the following:
- Be sure the electrical service is adequate for the model you have chosen. This information can be found on the serial plate, which is located on the side of the the cabinet and behind the grille.
- If the air conditioner is to be installed in a window, you will probably want to clean both sides of the glass first. If the window is a triple-track type with a screen panel included, remove the screen completely before installation.
- Be sure the air conditioner has been securely and correctly installed according to the installation instructions in this manual. Save this manual for possible future use in removing or installing this unit.
- When handling the air conditioner, be careful to avoid cuts from sharp metal fins on front and rear coils.
WARNING
Electrical Information
The complete electrical rating of your new room air conditioner is stated on the serial plate. Refer to the rating when checking the electrical requirements.
- Be sure the air conditioner is properly grounded. To minimize shock and fire hazards, proper grounding is important. The power cord is equipped with a three-prong grounding plug for protection against shock hazards.
- Your air conditioner must be used in a properly grounded wall receptacle. If the wall receptacle you intend to use is not adequately grounded or protected by a time delay fuse or circuit breaker, have a qualified electrician install the proper receptacle. Ensure the receptacle is accessible after the unit installation.
- Do not run air conditioner without side protective cover in place. This could result in mechanical damage within the air conditioner.
- Do not use an extension cord or an adapter plug.
Operation of Current Device
(Applicable to the unit adopts current detection device only)
The power supply cord contains a current device that senses damage to the power cord. To test your power supply cord do the following:
- Plug in the Air Conditioner.
- The power supply cord will have TWO buttons on the plug head. Press the TEST button, you will notice a click as the RESET button pops out.
- Press the RESET button, again you will notice a click as the button engages.
- The power supply cord is now supplying electricity to the unit. (On some products this it also indicated by a light on the plug head.)
NOTE:
- Do not use this device to turn the unit on or off .
- Always make sure the RESET button is pushed in for correct operation.
- The power supply must be replaced if it fails reset when either the TEST button is pushed, or it cannot be reset. A new one can be obtained from the product manufacturer.
- If power supply cord is damaged, it cannot be repaired. It MUST be replaced by one obtained from the product manufacturer.
NOTE: This air conditioner is designed to be operated under condition as follows:
Cooling operation| Outdoor temp:| 64-109°F/18-43°C(64-125°F/18-52°C for
special tropical models)
---|---|---
Indoor temp:| 62-9O°F/17-32°C
Heating operation| Outdoor temp:| 23-76°F/-5-24°C
Indoor temp:| 32-8O°F/O-27°C
Note: Performance may be reduced outside of these operating temperatures.
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT- Save these instructions for local inspector’s use.
IMPORTANT- Observe all governing codes and ordnances.
Note to Installer- Be sure to leave these instructions with the Consumer.
Note to Consumer- Keep these instructions for future reference.
Skill level- installation of this appliance requires basic mechanical skills.
Completion time- Approximately 1 hour.
We recommend that two people install this product.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the
Warranty.
You MUST use all supplied parts and use proper installation procedures as
described in these instructions when installing this air conditioner.
WINDOW REQUIREMENTS
Your air conditioner is designed to install in standard double hung windows with opening widths of 23 to 36 inches(584mm to 914mm).
Table 1
CUATION
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of the air conditioner.
Aluminum house wiring may present special problems- consult a qualified electrician.
When handling unit, be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils.
TOOLS YOU WILL NEED
-
Screwdriver
-
Level
TOOLS YOU MAY USE
-
Screwdriver
-
Pencil
-
Ruler or tape measure
-
Scissors or knife
NOTE:
Save Carton and these Installation Instructions for future reference. The carton is the best way to store unit during winter, or when not in use.
INSTALLATION INSTRUCTIONS (for 15000 Btu/h)
BEFORE YOU BEGIN
Read these instructions completely and carefully.
IMPORTANT – Save these instructions for local inspector’s use.
IMPORTANT – Observe all governing codes and ordnances.
Note to Installer- Be sure to leave these instructions with the Consumer.
Note to Consumer- Keep these instructions for future reference.
Skill level• installation of this appliance requires basic mechanical skills.
Completion time- Approximately 1 hour.
We recommend that two people install this product.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under the
Warranty.
You MUST use all supplied parts and use proper installation procedures as
described in these instructions when installing this air conditioner.
CAUTION
Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.
Do not change the plug on the power cord of the air conditioner.
Aluminum house wiring may present special problems- consult a qualified electrician.
When handling unit, be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils.
NOTE:
Preliminary Instructions
Do the following before starting to install unit. See illustrations below. Check dimensions of your unit to determine model type:
Unit Height: | 18 5/8″ | 17 5/8″ |
---|---|---|
Unit Width: | 26 1/2″ | 235/8″ |
Min. Window Opening: | 19 1/2″ | 18 1/2″ |
Min. Window Width: | 31″ | 28″ |
Max. Window Width: | 42″ | 401/2″ |
- Check window opening size– the mounting parts furnished with this air conditioner are made to install in a wooden sill double-hung window. The standard parts are for window dimensions listed above. Open sash to a minimum of 19 inches(483mm). See Fig .D.
- Check condition of window– all wood parts of window must be in good shape and able to firmly hold the needed screws. If not, make repairs before installing unit.
- Check your storm windows– if your storm window frame does not allow the clearance required , correct by adding a piece of wood as shown in Fig. E, or by removing storm window while room air conditioner is being installed .
- Check for anything that could block airflow-check area outside of window for things such as shrubs, trees, or awnings. Inside, be sure furniture, drapes, or blinds will not stop proper airflow.
- heck the available electrical service- Power supply must be the same as that shown on the unit serial nameplate. Power cord is 48 inches long. Be sure you have an outlet near.
- Carefully unpack air conditioner- Remove all packing material. Protect floor or carpet from damage. Two people should be used to move and install unit.
Hardware(Packed with the unit)
| 7/16 inch Locking screw and Flat washer for window panels| 2 ea.
---|---|---
| 3 / 4 (or 1/2)inch Long Hex-head Screw| 7
| Safety Lock| 1
| 1 / 2 inch Long screw and Locknut| 4 ea
| 3 / 4 inch Long Flat Head Bolt and Locknut| 2 ea
| Sill Angle Bracket| 2
| Lock Frame(For Wooden windows)(on some models)| 2
| 3 / 4 inch Long Screw( on some models)| 2
| Long hex-head locking screw for top angle, side retainer 5 /16 inch Long| 10
| Foam insert| 2
| Window sash seal foam| 1
| Safety Lock (for Vinyl-Clad window)(on some models)| 2
| Locking screw# 10X 1/ 4 panhead Phillips
screws (for Vinyl-Clad window)(on some models)| 2
| R1 hardware| 2
| Weather stripping
(10″3/4’1/12″)| 5
NOTE: R1 hardware and Weather stripping is only for Energy star models:
Tools Required
A large flat blade screw driver; Tape measure Adjustable wrench or pliers ;Pencil ;Level Socket wrenches; Phillips Screwdriver
A. Window Mounting
Remove Chassis
-
Pull down front grille and remove filter. (See Fig.1 ).
-
Lift front grille upwards and place to one side .
-
Locate the four front screws and remove. These screws will be needed to re-install the front panel (see Fig .2).
-
Push metal cabinet side to release plastic tabs on each side of front panel (see Fig.3).
-
Gently lift front panel off unit(see Fig .3A).
-
Disconnect the connector plug of the display panel from the unit and place front panel to one side(see Fig .4).
-
Remove shipping screws from top of unit and also on the side by the base if installed (see Fig .5).
-
Hold the cabinet while pulling on the base pan handle, and carefully remove the unit.
-
Add two foam inserts to holes in top of cabinet where shipping screws were removed from (see Fig.6).
-
Your unit may come with internal packaging . This packaging must be removed prior to installing the air conditioner back into the cabinet.(see Fig. 7).
Install Top Angle and Side Bracket
- Attach foam gasket to top angle above holes as shown in Fig .6.
- Install top angle and side retainers to cabinet as shown in Fig.8 (10 screws).
Assemble Window Filler Panels
-
Place cabinet on floor, a bench, or a table .
-
Slide”!” section of window filler panel into side retainer on the side of the cabinet (see Fig .9 & Fig .10). Do both sides.
-
Insert top and bottom legs of window filler panel frame into channel in the top angle and bottom rail. Do both sides.
-
Insert washer head locking 7/16″ screws (2) into holes in top leg of filler panel frame (see step 6). Do not totally tighten. Allow leg to slide freely. Screws will be tightened after section 6.
Place Cabinet in
-
Open window and mark center of window stool as shown(Fig.11 ).
-
Place cabinet in window with bottom stool angle firmly seated over window stool as shown . Bring window down temporarily behind top angle to hold cabinet in place(Fig.12).
-
Shift cabinet left or right as needed to line up center of cabinet on center line marked on stool.
-
Fasten cabinet to window stool with 2 screws into holes(You may wish to pre-drill pilot holes).
-
Add bottom rail seal over screws to window stool.
Install Support Bracket
-
Hold each support bracket flush against outside of sill, and tight to bottom of cabinet as shown in Fig .15A. Mark brackets at top level of sill, and remove.
-
Assemble sill angle bracket to support brackets at the marked position(Fig .15B). Hand tighten , but allow for any changes later.
NOTE: Check that air conditioner is tilted back about 11/4″ to 15/ ~• (tilted about 3°to 4 °downward to the outside). After proper installation, condensate should not drain from the overflow drain hole during normal use, correct the slope otherwise (Fig .14 ).
-
Install support brackets(with sill angle brackets attached) to correct hole in bottom of cabinet as shown in Fig .16.
-
Tighten all 6 bolts securely.
Extend Window Filler Panels
-
Carefully raise window to expose filler panel locking screws. Loosen screws so filler panels slide easily.
-
Extend panels to fill window opening completely. Tighten locking screws on top(Fig .17).
-
Close window behind top angle .
-
Attach the top angle to window frame: Use a 3/32″ drill bit to drill one hole through the hole in the middle of top angle into the window frame, and drive one 3/ 4″ (or 1/ 2″) HEX-HEAD locking screw through hole in the middle of top angle into the window frame as shown (Fig .17 A).
Attach Window Filler Panels to Window Frame
- Extend the window filler panels out against the window frame.
- Use a 1/8″ drill bit to drill a starter hole through the hole in the top leg of each window filler panel and into the window sash (Fig . 18A and Fig. 18B). Connect with one 3/ 4″ ( or 1 / 2″) long hex head screw.
Install Window Sash Seal and Safety Lock
- Trim sash seal to fit window width . Insert into space between upper and lower sashes(Fig .18).
- Attach right angle safety lock (Fig .19).
Install Chassis into Cabinet and Install Front to Unit
- Lift air conditioner and carefully slide into cabinet leaving 6 inches protruding.
- DO NOT push on controls or finned coils.
- Be sure chassis is firmly seated towards rear of cabinet.
- Installation of front is the reverse of removal outlined in Section 1.
INSTALL R1 HARDWARE (only be applicable to Energy star models)
In order to minimize air leaks and ensure optimal insulation, it is necessary to install the included R 1 hardware to the side curtain Follow the instructions below.
Step 1. After the unit is installed to the window, measure the inner width of the side curtain as shown (Fig .20).
Step 2. Remark a line on the provide R1 insulation panel according to a length 1/8″(3mm) less than the measured width in step 1, then cut the R1 insulation panel along the line (Fig.12).
Step 3. Slide the R1 insulation panel into the side curtain, the side with pattern should facing the indoor side .(Fig .22).
Step 4. Repeat on the other side.
INSTALL WEATHER STRIPPING (only be applicable to Energy star models)
In order to minimize air leaks between the room air conditioner and the window opening, trim the weather stepping with a proper length, peel off the protective backing and plug any gaps if needed (Fig .23).
B. Thru-The-Wall Installation
NOTE: Consult local building codes prior to installation, or a qualified carpenter.
Select Wall Location
The air conditioner has a slide-out chassis, so that it can be installed through an outside wall as specified below:
Max. Wall thickness: 1 Z’ or 1 O’
IMPORTANT: Side louvers must never be blocked .
NOTE: All parts needed for Thru-The-Wall installation are provided, except a wood frame, shims, and 10 wood screws(#10-1″ long minimum). Select a wall surface that:
- does not support major structural loads such as the frame construction at ends of windows, and under truss-bearing points , etc.
- does not have plumbing or wiring inside.
- is near existing electrical outlets, or where another outlet can be installed .
- faces , and is not blocked to the area to be cooled .
- allows unblocked airflow from rear sides and end(outside) of installed air conditioner.
Prepare Wall
- Prepare wall in frame construction (including brick and stucco veneer). Working from inside the room , find wall stud nearest the center of area where air conditioner will be installed (by sounding wall , or by magnetically finding nails).
- Cut or knock out a hole on each side of center stud.
- Measure between inside edges of every other stud as shown in Fig.1.
Carefully measure and cut an opening with the following dimensions depending
on your model. See Fig .1 and Fig .2.
WIDTH ” X “= inside model width plus twice the thickness of framing material
used.
HEIGHT”Y’ =inside model height plus twice the thickness of framing material
used.
Inside Frame Height: 18-7/8″(47.9cm) or18” (45.7cm)
Inside Frame Width: 26-3/4″(67.9cm) or 23-7/8″(60.6cm)
- Build a wooden frame with the INSIDE dimensions of your model listed above. (Measure twice remember). Frame depth should be the same as wall thickness . Fill in the space from the opening to the studs with wood spacers , as shown .
- Nail frame to spacers to spacers with front flush with drywall.
NOTE: If wall thickness is 8-1/2″ or more, add aluminum flashing over bottom of frame opening to assure no water can enter area between inner and outer wall.
Prepare and Install Cabinet
- Slide chassis from cabinet. Refer back to Step one of Window Mounting.
- Place cabinet into opening with bottom rail resting firmly on bottom board of wooden frame.
- Position cabinet to achieve proper slope for water removal.(See Fig .5 below.)
- Secure bottom rail to wood frame with two large wood screws 1″(2 .5cm) long using the two holes in the bottom of the channel resting on frame. (See Fig .6 ).
NOTE : Check that air conditioner is tilted back about 11/4″ to 15/8″(tilted about 3°to 4°downward to the outside). After proper installation, condensate should not drain from the overflow drain hole during normal use, correct the slope otherwise (Fig.14 ).
Refer to Step 5 of Window Mounting for assembly of support brackets. A wooden strip nailed to the outside wall should be used in conjunction with sill support angle brackets.
- Screw or nail cabinet wooden frame using shims if frame is oversized, to eliminate distortion. See Fig .8.Remember to maintain proper slop as described in Step 3.
- Install chassis into cabinet by following all steps in Step 8 of Window Mounting.
OPTIONAL: Caulking and installation of trim on interior wall may be done. You can buy wood from your local number or hardware supply. On the outside, caulk openings around top and sides of cabinet, and all sides of wood sleeve to the opening .
NOTE: See Step 5, Item 3 of Window Mounting Instructions for bottom rail seal location .
C. Masonry Construction
- Cut or build a wall opening in the masonry wall similar to the frame construction (refer to Step of Thru-the-wall Installation for a wall thickness greater than 8-1/2″ ).
- Secure cabinet in place using masonry nails, or the right masonry anchor screws. (Another way to do this is to build an in -between frame of 2×4 s as shown in the Step 2 Prepare Wall illustrations-but make it double framed on either side, and install between masonry wall opening and cabinet. Frame must be securely anchored to masonry wall opening). This way gives very good louver clearance on either side of cabinet.
- Install a lintel to support masonry wall above cabinet. Existing holes in cabinet can be used and/ or additional holes can be drilled to fasten cabinet at various positions. Be sure that side louver clearance is in accordance with Step 1 above.
- Install exterior cabinet support brackets as shown in Step 2 of Thru-the-wall installation . Caulk or flash if needed , to provide a weathertight seal around top and sides of cabinet.
- To complete installation, apply wood trim molding around room side projection of cabinet.
NORMAL SOUNDS
NOTE:
All the illustrations in this manual are for explanation purpose only. Your air conditioner may be slightly different. The actual shape shall prevail.
AIR CONDITIONER FEATURES
ELECTRONIC CONTROL OPERATING INSTRUCTIONS
Before you begin , thoroughly familiarize yourself with the control panel as shown below and all its functions, then follow the symbol for the functions you desire. The unit can be controlled by the unit control alone or with the remote.
TO TURN UNIT ON OR OFF:
Press ON/OFF button to turn unit on or off.
NOTE: The unit will initiate automatically the Energy Saver function under Cool , Dry, Auto (only Auto-Cooling and Auto-Fan) modes.
TO CHANGE TEMPERATURE SETTING:
Press / UP/DOWN button to change temperature setting.
NOTE: Press or hold either UP(▴) or DOWN (▾) button until the desired temperature is seen on the display. This temperature will be automatically maintained anywhere between 62°F(17°C) and 86°F(30°C). If you want the display to read the actual roogn temperature, see To Operate on Fan Only section .
CLEAN AIR FEATURE: (on some models)
Press Clean Air button the ion generator is energized and will help to remove pollen and impurities from the air, and trap them in the filter.
TO ADJUST FAN SPEEDS:
Press to select the Fan Speed in four steps-Auto, Low, Med or High. Each time the button is pressed, the fan speed mode is shifted .For some models, the fan speed can not be adjusted under HEAT mode. On Dry mode the fan speed is controlled at Low automatically.
SLEEP FEATURE:
Press Sleep button to initiate the sleep mode. In this mode the selected temperature will increase (cooling) or decrease (heating) by 2°F/1 (or 2)°C 30 minutes after the mode is selected . The temperature will then increase (cooling) or decrease (heating) by another 2°F/1 (or 2)°C after an additional 30 minutes. This new temperature will be maintained for6 hours before it returns to the originally selected temperature. This ends the Sleep mode and the unit will continue to operate as originally programmed . The Sleep mode program can be cancelled at any time during operation by pressing the Sleep button again .
CHECK FILTER FEATURE:
Press Check filter button to initiate the is feature . This feature is a reminder to clean the Air Filter for more efficient operation . The LED(light) will illuminate after 250 hours of operation . To reset after cleaning the filter, press the Check Filter button and the light will go off.
ENERGY SAVER FEATURE:
Press Energy saver button to initiate this function . This function is available on COOL, DRY, AUTO (only AUTO-COOLING and AUTO-FAN) modes. The fan will continue to run for 3 minutes after the compressor shuts off. The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature, at which time the compressor turns back on and Cooling Starts.
FOLLOW ME FEATURE:(on some models)
This feature can be activated from the remote control ONLY. The remote control serves as a remote thermostat allowing for the precise temperature control at its location.
To activate the Follow Me feature, point the remote control towards the unit and press the Follow Me button. The remote display is actual temperature at its location . The remote control will send this signal to the air conditioner every 3 minutes interval until press the Follow Me button again .If the unit does not receive the Follow Me signal during any 7 minutes interval, the unit will beep to indicate the Follow Me mode has ended .
TO SELECT THE OPERATING MODE:
To choose operating mode, press Mode button .Each time you press the button, a mode is selected in a sequence that goes from Auto, Cool , Dry ,heat(cooling only models without)and Fan. The indicator light beside will be illuminated and remained on once the mode is selected .
The unit will initiate automatically the Energy Saver function under Cool , Dry, Auto(only Auto-Cooling and Auto-Fan) modes.
To operate on Auto feature:
- When you set the air conditioner in AUTO mode, it will automatically select cooling, heating(cooling only models without), or fan only operation depending on what temperature you have selected and the room temperature.
- The air conditioner will control room temperature automatically round the temperature point set by you.
- In this mode, the fan speed cannot be adjusted, it starts automatically at a speed according to the room temperature .
To operate on Fan Only:
- Use this function only when cooling is not desired such as for room air circulation or to exhaust stale air(on some models). (Remember to open the vent during this function, but keep it closed during cooling for maximum cooling efficiency.) You can choose any fan speed you prefer.
- During this function, the display will show the actual room temperature, not the set temperature as in the cooling mode.
- In Fan only mode ,the temperature is not adjusted. To operate on Dry mode:
- In this mode, the air conditioner will generally operate in the form of a dehumidifier. Since the conditioned space is a closed or sealed area , some degree of cooling will continue.
TIMER: AUTO START/STOP FEATURE:
- When the unit is on or off, first press Timer button, the TIMER ON indicator light illuminates. It indicates the Auto Start program is initiated.
- When the time of TIMER ON is displayed ,press the Timer button again, the TIMER OFF indicator light illuminates. It indicates the Auto Stop program is initiated.
- Press or hold the UP or DOWN button to change the Auto time by 0.5 hour increments, up to 10 hours. then at 1 hour increments up to 24 hours. The control will count down the time remaining until start.
- The selected time will register in 5 seconds, and the system will automatically revert back to display the previous temperature setting or room temperature when the unit is on .(when the unit is off, there is no display.)
- Turning the unit ON or OFF at any time or adjusting the timer setting to 0.0 will cancel the Auto Start/Stop timed program.
DISPLAYS
DISPLAYS:
Shows the set temperature in” °C” or ” °F ” and the Auto-timer settings. While on Fan only mode, it shows the room temperature .
Error codes:
AS-Room temperature sensor error-Unplug the unit and plug it back in .If error repeats, call for service.
NOTE: In Fan only mode,it will display” LO” or” HI” .
- Evaporator temperature sensor error-Unplug the unit and plug it back in .If error repeats, call for service.
NOTE: “• “is displayed as shown in the left picture.
HS -Electric heating sensor error-Unplug the unit and plug it back in .If error repeats, call for service.
NOTE:
If the unit breaks off unexpectedly due to the power cut, it will restart with the previous function setting automatically when the power resumes.
Air Directional Louvers
The 4-way air directional louvers allow you to direct the air flow Up or Down(on some models) and Left or Right throughout the room as needed . To adjust the air directional louvers side-to -side, use the center handles as you move it side-to-side.
ADDITIONAL THINGS YOU SHOULD KNOW
Now that you have mastered the operating procedure, here are more features in your control that you should become familiar with.
- The Cool circuit has an automatic 3 minute time delayed start if the unit is turned off and on quickly. This prevents overheating of the compressor and possible circuit breaker tripping .The fan will continue to run during this time.
- The control is capable of displaying temperature in degrees Fahrenheit or degrees Celsius. To convert rom one to the other, press and hold the Left and Right Temp/Timer buttons at the same time, for 3 seconds.
Fresh Air Vent Control
The Fresh Air Vent allows the air conditioner to :
-
Recirculate inside air – Vent Closed (See Fig. A)
-
Draw fresh air into the room- Vent Open (see Fig .B)
Exchange air from the room and draws fresh air into the room – Vent and Exhaust Open (see Fig .C)
CARE AND CLEANING
CAUTION
Clean your air conditioner occasionally to keep it looking new. Be sure to unplug the unit before cleaning to prevent chock or fire hazards.
Air Filter Cleaning
The air filter should be checked at least once a month to see if cleaning is necessary. Trapped particles in the filter can build up and cause an accumulation of frost on the cooling coils.
Air Filter Cleaning
- Remove the filter by sliding out from the right-hand side.
- Wash the filter using liquid dishwashing detergent and warm water. Rinse filter thoroughly. Gently shake excess water from the filter. Be sure the filter is thoroughly dry before replacing. Or, instead of washing you may vacuum the filter clean.
Note: Never use hot water over 40 °C(104°F) to clean the air filter. Never attempt to operate the unit without the air filter.
Cabinet Cleaning
- Be sure to unplug the air conditioner to prevent shock or fire hazard. The cabinet and front may be dusted with an oil-free cloth or washed with a cloth dampened in a solution of warm water and mild liquid dishwashing detergent. Rinse thoroughly and wipe dry.
- Never use harsh cleaners, wax or polish on the cabinet front.
- Be sure to wring excess water from the cloth before wiping around the controls. Excess water in or around the controls may cause damage to the air conditioner.
- Plug in air conditioner
Winter Storage
If you plan to store the air conditioner during the winter, remove it carefully from the window according to the installation instructions. Cover it with plastic or return it to the original carton.
TROUBLESHOOTING TIPS
Before calling for service, review this list. It may save your time and expense. This list includes common occurrences that are not the result of defective workman-ship or materials in this appliance.
Problem | Solution |
---|---|
Air conditioner does not start | _Wall plug disconnected. Push plug |
firmly into wall outlet._
House fuse blown or circuit breaker tripped. Replace fuse with time delay
type or reset circuit breaker.
Plug Current Device Tripped. Press the RESET button.
Power is OFF. Turn power ON.
Air from unit does not feel cold enough| Room temperature below
62°F(17°C ). Cooling may not occur until room temperature rises above
62°F(17°C).
Temperature sensing behind air filter element touching cold coil. Keep it
from the cold coil.
Set to a Lower temperature.
Compressor stopped when changing modes. Wait for 3 minutes after set to the
COOL mode.
Air conditioner cooling, but room is too warm- ice forming on cooling
coil behind decorative front.| Outdoor temperature below
64°F(18°C). To defrost the coil, set FAN ONLY mode.
Air filter may be dirty. Clean filter. Refer to Care and Cleaning section.
To defrost, set to FAN ONLY mode.
Thermostat set too cold for night-time cooling. To defrost the coil, set to
FAN ONLY mode. Then, set temperature to a Higher setting.
Air conditioner cooling, but room is too warm- NO ice forming on cooling
coil behind decorative front.| Dirty air filter- air restricted.
Clean air filter. Refer to Care and Cleaning section.
Temperature is set too High, set temperature to a Lower setting.
Air directional louvers positioned improperly. Position louvers
for better air distribution.
Front of units is blocked by drapes, blinds, furniture, etc. – restricts
air distribution. Clear blockage in front of unit.
Doors, windows, registers, etc. Open- cold air escapes. Close
doors, windows, registers.
Unit recently turned on in hot room. Allow additional time to remove” Stored
heat” from walls, ceiling, floor and furniture.
Air conditioner turns on and off rapidly| Dirty air filter- air
restricted. Clean air filter.
Outside temperature extremely hot. Set FAN speed to a Higher setting to
bring air past cooling coils more frequently.
Noise when unit is cooling| Air movement sound. This is
normal . If too loud, set to a slower FAN setting.
Window vibration – poor installation. Refer to installation
instructions or check with installer.
Water dripping INSIDE when unit is cooling.| Improper
installation. Tilt air conditioner slightly to the outside to allow water
drainage. Refer to installation instructions – check with installer.
Water dripping OUTSIDE when unit is cooling.| Unit
removing large quantity of moisture from humid room. This is normal during
excessively humid days.
Remote Sensing Deactivating Prematurely (some models)| Remote
control not located within range. Place remote control within 20 feet & 180
radius of the front of the unit.
Remote control signal obstructed. Remove obstruction.
Room too cold| Set temperature too low.
Increase set temperature.
AIR CONDITIONER WARRANTY
Your product is protected by this warranty:
Warranty service must be obtained from Medea Consumer Services or an authorized Medea servicer.
| WARRANTY PERIOD| MIDEA, THROUGH ITS AUTHORIZED SERVICERS, WILL:| THE
CONSUMER WILL BE RESPONSIBLE FOR:
---|---|---|---
FULL ONE-YEAR WARRANTY| One year from original purchase date| Pay all costs
for repairing or replacing parts of this appliance which prove to be defective
in materials or workmanship.| Transportation and costs of service calls that
are listed under NORMAL RESPONSIBILITIES OF THE **CONSUMER***
Medea replacement parts shall be used and will be warranted only for the period remaining on the original warranty.
**NORMAL RESPONSIBILITIES OF THE CONSUMER***
This warranty applies only to products in ordinary household use, and the consumer is responsible for the items listed below:
- Proper use of the appliance in accordance with instructions provided with the product.
- Proper installation by an authorized service professional in accordance with instructions provided with the appliance and in accordance with all local plumbing, electrical and / or gas codes.
- Proper connection to a grounded power supply of sufficient voltage, replacement of blown fuses, repair of loosen connections or defects in house wiring.
- Expenses for making the appliance accessible for servicing.
- Damages to finish after installation.
EXCLUSIONS
This warranty does not cover the following:
- Failure caused by damage to the unit while in your possession (other than damage caused by defect or malfunction), by its improper installation, or by unreasonable use of the unit, including without limitation, failure to provide reasonable and necessary maintenance or to follow the written Installation and Operating Instructions.
- Damages caused by services performed by persons other than authorized Midea servicers; use of parts other than Midea replacement parts; obtained from persons other than such Midea customer service; or external causes such as abuse, misuse, inadequate power supply or acts of God.
- If the unit is put to commercial, business, rental, or other use or application other than for consumer use, we make no warranties, express or implied, including but not limited to, any implied warranty of merchantability or fitness for particular use or purpose.
- Products without original serial numbers or products that have serial numbers which have been altered or cannot be readily determined.
Note: Some states do not allow the exclusion or limitation of incidental or consequential damages. So this limitation or exclusion may not apply to you.
IF YOU NEED SERVICE
Keep your bill of sale, delivery slip, or some other appropriate payment record. The date on the bill established the warranty period should service be required. If service is performed, it is your best interest to obtain and keep all receipts. This written warranty gives you specific legal rights. You may also have other rights that vary from state to state. Service under this warranty must be obtained by following these steps, in order:
- Contact Midea Consumer Services or an authorized Midea servicer at 1-866-646-4332
- If there is a question as to where to obtain service, contact our consumer relations Department.
Read User Manual Online (PDF format)