SUEVIA 130.5011 Cow Brush EasyCleaner Instruction Manual

June 12, 2024
SUEVIA

SUEVIA 130.5011 Cow Brush EasyCleaner

SUEVIA 130.5011 Cow Brush EasyCleaner

Spare Parts

Spare Parts

Best.-Nr. Description
132.4021 Bearing unit
132.4025 Controller
132.4035 Shaft holder
132.4062 Feather key 8×70 C45
132.4076 Controller board
132.4090 Roll pin 10×50
132.4094 Gear motor
132.4095 Motion switch
132.4241 Frame unit
132.4242 Protective rubber
132.4245 Catch
132.4246 Brush
132.4250 Shaft
132.4251 Feather key 10×30 C45

Mounting

Mounting

Installation
  1. Measure the height of the smallest cow = mounting height of the brush
  2. A = height of the smallest cow + 45 cm
  3. B = A + 14 cm
  4. Fix Cow Brush on a stable wall with 4 pieces of screws/dowels or threaded rods
  5. Establish electrical connection
Technical Data
Ref. 130.5011
Electric motor 230 V, 50 Hz
Motor capacity 370 W
Rev. of bristle 34 U/min
Dimensions (H x B x T) 960 x 830 x 780 mm
Weight ca. 67 kg

Functional Principle

The SUEVIA Cow Brush is ready for use as soon as it is mounted on a solid wall and the electrical connection is established (an emergency shut-off switch and a residual current device are to be provided on site (see electrical circuit diagram).
By vibration the brush, the Cow Brush is starting up. Now the brush are rotating. Fixed operating time: 2 min. Resistance reverse mechanism adjustable. In case of an overload situation, e.g. wound up tail, the cow brush stops automatically and changes direction of rotation. After a short phase of making acquaintance, the Cow Brush is readily accepted by the animals.

SUEVIA Cow Brush is equipped with a security automatic shut-off. This automatic shut-off possibility stops the rotating brushes and starts turning them in the opposite direction as soon as the adjusted force is exceeded. (Factory-adjusted is an average force of 4 A).

Hole pattern for drilling
Hole Pattern For Drilling

Electric Connection

Electric Connection

Control System

Control System

Attention!
Electric Connection 230 V ; 1~; according connection diagram, observe VDE 0100! Electrical installation has to be completed by an authorized electrician.
All electric cables and equipment must be protected against mechanical damage or against possible damages by the animals.
Local national rules and regulations must be respected!
The Cow Brush has to be operated by an emergency stop switch (provided by the customer’s side)!
Cow Brush must be used in conjunction with a residual current device 230 V – 0,03 A (provided by the customer’s side)!

Maintenance and Cleaning

Every month

  • Check the right function of the ON/OFF switch

Quarterly

  • Examine the fix position of the screws.

  • Clean the motor from dirt or dust.

When using a high pressure cleaner:
do not concentrate the water jet directly on the motor or electrical cage!
Maintenance and Cleaning

Installation Hints

  • Archive this mounting instructions, delivered together with your Cow Brush together with the rest of your documentations so that it is available at any time!
  • The place, where you mount the Cow Brush, should be out of reach of children.
  • If the Cow Brush is mounted on walls made of brick or wood, threaded bars have to be used (the wall or brickwork does not have the necessary stability for simple heavy-duty dowels).
  • When setting up the Cow Brush in the open air, protect it with a roof against rain and snow.
  • In front of the Cow Brush must be enough free space for other animals to pass while one animal is brushing himself.
  • Electrical installation has to be completed by an authorized electrician.
  • The Cow Brush has to be operated with an emergency stop switch (by the customer)!
  • The Cow Brush must be used with an own residual current device 230 V – 0,03 A (by the customer)!
  • All electric cables and pipes have protected against possible mechanical damages or possible damages by animals.
  • During maintenance or repair the unit has to be separated from mains supply.
  • The puff at the animal’s tale must be cut shortest possible.
  • Do not wear long garments which are hanging around in the surroundings of the Cow Brush.
  • Avoid to be too close with your hair at the brush.
  • In general fur, hair, particles of clothing, body parts of people and animals involve a risk to be winded up!

Intended purpose
SUEVIA Cow Brush must only be used for care and cleaning purposes of the skin and body of cows and cattle with short hair. The user has to see to it that those types of cows or cattle with long hair are hold out of reach of Cow Brush. There exists the risk of the fur being wound up! Other applications are not permitted!

Safety Rules

SUEVIA Cow Brush has been designed according EC machine recommendations No. 2006/.. EWG to the latest technological levels. Optimal and secure function of this unit assumes safe and proper transport, professional installation, careful use and starting of machine as well as regular maintenance.
For this please observe the following:

  • project/planning documentation
  • transport and installation instructions
  • operating instructions

Intended Use
Assure yourself that before the Cow Brush is switched on nobody can be endangered.
Keep to the adjustments, maintenance schedule and inspections prescribed in the operating instructions including the details given for exchange of parts or equipment, etc..
This work must be undertaken by authorized persons.

Security hints
The unit could be dangerous for persons, in particular children, or animals or cause material damage, when inexpert handling or maintenance, etc. is done by non-skilled persons.
The operator has to ensure, that only skilled and qualified persons work on this unit.

For security recommendations please refer to:

  • National and local safety regulations
  • National and local electrical installation instructions
  • National and local earthing instructions
  • Association of electro-technical, electronic, informatic associations DIN VDE 0100
  • Electrical installation regulations for agricultural units
  • Instructions and specifications of safety an health protection VSG 1.1

Issue
Misprints and errors excepted. We reserve the right at any timefor technical changes without prior notice!
We can not be hold responsible for the correctness, sufficiency and actuality of document.

EC-Conformity Declaration

Exclusion of liability
Our general business conditions are valid.

We can not be held responsible for the fact that

  • The operating instructions or planning, transport and installation rules are not observed.
  • Cow Brush, including all additional equipment, was not connected accordingly and in proper described form. (was not installed or mounted by a skilled expert).
  • Cow Brush, including all additional equipment, was operated in an unsuitable way.
  • Cow Brush, including all additional equipment. was not maintained according to the recommendations.
  • Security installations were not used or made unoperational.
  • Technical changes or functional modifications were made by the operator, or by the installation experts, which are not allowed by manufacturer.

Conformity declaration
Non observation of these safety regulations and precautionary measures will result in the loss of validity of this conformity declaration delivered with each unit according to EC machine regulations.

EG – Konformitätserklärung
We hereby declare, that our product
130.5011
(product, model)
corresponds to the following relevant and valid regulations:

  • Recommendation 2006/42/EC “machines”
  • Recommendation 2004/108/EC electromagnetic compatibility
  • Recommendation 2006/95/EC “low voltage recommendation”
  • 1. GPSGV / 9.GPSGV

M. Scholl (Dipl. Ing. /FH)

SUEVIA HAIGES GmbH, Max-Eyth-Strasse 1, 74366 Kirchheim am Neckar – Germany

Logo

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals