Product Information

The product is a remote control transmitter designed for controlling a ceiling fan with light. It operates on 2 1.5V/AAA batteries (included). The transmitter has two modes – Universal Mode and Learning Mode. In Universal Mode, the fan can be controlled with other remote transmitters with the same setting. In Learning Mode, the fan can be controlled with a specific remote transmitter by following the learn function setting process. The transmitter has dimming and non-dimming settings, allowing the user to adjust the brightness of the light. It also has a lock protection feature that stops the fan operation if there is an obstruction, and an overload protection feature that shuts off the fan if it is overloaded.

Product Usage Instructions

  1. To operate the transmitter, remove the battery cover and install 2 1.5V/AAA batteries (included). Replace the cover.

  2. Note: If not using the transmitter for a long period of time, remove the batteries to prevent damage and store it away from excess heat or humidity.

  3. Dimming / Non Dimming Setting:

    • To select the dimming function, press and hold the DIM button. The light will cycle from bright to dim to bright until the button is released.
    • To select the non-dimming function (light ON/OFF only), press the ON button. The light will maintain the last setting if turned off.
    • Note: The transmitter is pre-set with the dimming function at the factory.
  4. Universal Mode and Learning Mode:

    • Universal Mode: Place the dip switch at the UPPER position (COMMON CODE). The fan remote control is ready to use. In this mode, the fan can be controlled with other remote transmitters with the same setting.
    • Learning Mode: Place the dip switch at the LOWER position (L.CODE). To control the fan with a specific remote transmitter, follow the learn function setting process:
    1. Restore power source to your fan.
    2. Press and hold the LEARN button on the transmitter for at least 3 seconds. You must press the LEARN button within 60 seconds of restoring power to the fan.
    3. Note: Power must be off for a minimum of 10 seconds before turning it back on for remote control learn function setting.
    4. If the fan is installed with a light, the light will blink 2 times to indicate that the remote control setting process is complete. For fans without light, check operation using the remote transmitter.
    5. Note: To control multiple fans, ensure that they are set at the same setting. A fan can be controlled by a maximum of 2 transmitters.
  5. Receiver Protective Functions:

    • Lock Protection: If there is an obstruction in the fan blades or motor during operation, the motor will keep trying to run for 5 times and then stop after about 60 seconds of interruption. To reset, turn the fan off with the remote transmitter and then turn it on again. Alternatively, you can turn off the power for 15 seconds and then turn it back on before turning on the fan.
    • Overload Protection (Current Limit): The receiver limits the maximum current output when the fan or light load is increased abnormally. If the fan is overloaded, it will shut off.
  6. ANDERIC DC1 Remote Control Fan Speed and Light Functions:
    Fan Speed: Use the buttons numbered 1 to 6 to control the fan speed. 1 is the minimum speed, 3 is medium low speed, 5 is medium high speed, 2 is low speed, 4 is medium speed, and 6 is high speed.

    • The OFF button turns the fan off.
    • Forward/Reverse Button: Press this button once to change the direction of the fan rotation. The fan must be running to reverse. Please note that it may take a few seconds for the direction to change once the button has been pressed.

TRANSMITTER OPERATION

Remove the battery cover from the remote control transmitter and install batteries, Replace the cover.

Note : Use 2 1.5V/AAA batteries (included).

Note : If not using for long period of time, remove battery to prevent damage to remote transmitter, and store the remote transmitter away from excess heat or humidity.

DIMMING / NON DIMMING SETTING

The “DIM” selection is the light dimmable selection , the light will cycle from bright to dim to bright until button is released. The “ON” selection is the light ON/OFF only (non dimming function). Light will maintain last setting if turned off.

ANDERI-D-Reversibl- wit-6-Speed-for- Hampt-Bay-Monte-Carlo-fig-
\(2\)

Note: The remote control is pre-set with dimming function at factor y,

Note: Ensure electricity is turned off before installing the receiver (Refer to the ceiling fan instructions)

UNIVERSAL MODE AND LEARNING MODE

There is a “Universal Mode” and “Learning Mode” with the remote control.
When selecting “Universal Mode”, simply place dip (code) switch at UPPER position(COMMON CODE). Your fan remote control is ready to use.

Note: If using universal mode, your fan can be controlled with other remote transmitters with the same setting.

To control the fan with specific remote transmitter, choose “ Learning Mode” by placing the dip (code) switch at LOWER position(L.CODE) and then select function setting as below.
Learn function setting: Restore power source to your fan, press and hold the “ LEARN ” button for at least 3 seconds. You must press the “LEARN ” button within 60 seconds of restoring power to the fan.

Note: Power must be off for a minimum 10 seconds, then turn the power back on for remote control learn function setting.

Note: If the fan is installed with light, light will blink 2 times. The remote control setting process is complete and your fan is ready for use. For fans without light, check operation using remote transmitter. Note: To control multiple fans, ensure the settings are set at the same setting. A fan can be controlled by 2 transmitters maximum.

RECEIVER PROTECTIVE FUNCTIONS

Lock protection- The DC motor has a built-in safety feature against blade or motor obstruction during operation. should something obstruct the fan blades or motor, the motor will keep trying to run for 5 times and then stop operation after about 60 seconds of interruption. Please remove obstacles and reset. To reset, turn the fan off with remote transmitter and then turn the fan on. Or, you may turn the power off for 15 seconds. Then turn the power back on, and then turn the fan on.
Over load protection (current limit)- The device limits the maximum current output from the receiver/drive when the fan or light load is increased abnormally. The fan will shut off if over lamped.  Remote Control Fan Speed And Light Functions.

Fan speed

  1. minimum speed
  2. low speed
  3. medium low speed speed
  4. medium speed6 = high speed
  5. medium high
  6. high speed

 This button turns the fan off.
Forward/ Reverse button- This button controls the direction of the fan rotation.
Press once to change direction of the fan rotation. Fan must be running to reverse.
(Note: It can take a few seconds to change direction once button has been pushed.)
Light button- Press this button to turn light on or off. To dim light ( Setting at “DIM” position ), hold down the button, the light will cycle from bright to dim to bright until button is released.
Note : This remote control has an auto resume function, the fan and light will maintain the last setting if power is turned off.

WALL MOUNT CRADLE INSTALLATION

ANDERI-D-Reversibl- wit-6-Speed-for- Hampt-Bay-Monte-Carlo-fig-
\(4\)

Install Transmitter wall mount cradle with 2 screws provided.
THIS DEVICE COMPLIES WITH PART 15 OF THE FCC RULES OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS.

  1. THIS DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE AND
  2. THIS DEVICE MUST ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY CAUSE UNDESIRED OPERATION.

NOTE:

  1. When powering on after installation, the fan may start automatically due to factory preset settings.
  2. If fan or light isn’t working, reset power ( turn the power off for at least 10 seconds and then turn the power back on ) and redo the learn function setting.
  3. If there are multiple fans in the same room, when setting, please make sure the power supply for the setting fan is independent of the other fans.
  4. When turning the fan on or operating the forward/reverse function, it is normal for the fan to rotate and run on both directions, for approximately 1 minute and then stop. For support go to Anderic.com/DC1