INTERMATIC ET9500 1-Circuit Electronic Control Instruction Manual

June 12, 2024
Intermatic

INTERMATIC ET9500 1-Circuit Electronic Control

Product Information

  • The BEMS INTERFACE BOX (Model ET9500) is a gateway device used for connecting and controlling various electrical devices in a building energy management system (BEMS). It is designed for indoor and outdoor use and comes in a lockable metal enclosure with a Type 3R rating. The box has an input voltage range of 120-277 VAC and operates at a frequency of 50/60 Hz. It consumes a maximum power of 3 W and weighs approximately 11.8 lbs.
  • The ET9500 BEMS INTERFACE BOX is equipped with multiple knockout options for AC input and gateway connections. It supports wire sizes ranging from AWG #18 to #8. The box also features an ethernet or RS 485 connection for easy integration into the BEMS network.
  • The product is compliant with the Federal Communications Commission (FCC) regulations for electromagnetic interference.

Product Usage Instructions

  1. Install the mounting brackets to the enclosure following the instructions provided with the brackets.
  2. Securely mount the enclosure in the desired location using appropriate hardware capable of supporting the weight of the ET9500.
  3. Ensure that the unit is mounted vertically (upright) and there is enough space for the enclosure door to fully swing open.
  4. Remove the dead front cover and hardware from the ET9500, and retain them for later use.
  5. Select and remove the appropriate knockout(s) on the enclosure for AC input and gateway connections.
  6. Connect the wires to the proper terminals on the gatewaymodule, ensuring that no insulation is crimped in the terminal.
  7. Connect the ground wire to the ground screw and firmly tighten, making sure no insulation is crimped in the terminal.
  8. Replace the dead front cover and secure it with the screws removed earlier.
  9. Connect the ethernet or RS 485 cable to the Gateway module. Refer to the included Quick Start Guide for connection guidance.

Note : For any warranty claims or service, please visit www.intermatic.com or contact Intermatic Incorporated Customer Service at 815-675-7000.

Risk of Fire or Electric Shock

  • Disconnect power at the circuit breaker(s) or disconnect switch(es) before installing or servicing.
  • Installation and/or wiring must be in accordance with national and local electrical code requirements.
  • Use #18-#8 AWG wires, rated at least 90°C – COPPER conductors ONLY.
  • For outdoor locations or wet locations (rain-tight), conduit hubs that comply with requirements of the UL514B (standard for fitting conduit andoutlet boxes) are to be used.
  • KEEP DOOR CLOSED AT ALL TIMES when not servicing.
  • Replace dead front after servicing or installation.

Specifications

  • Input Voltage: 120-277 VAC, 50/60 Hz
  • Power Consumption: 3 W MAX
  • Shipping Weight: 11.8 lbs.
  • Enclosures: Type 3R indoor/outdoor lockable metal enclosure
  • Knockouts: Combination of 12 1/2 – 3/4 inch size
  • Wire Size: AWG #18-#8

Application notes

  • Thoroughly read instructions before installing.
  • Observe warnings and instructions on front panel and unit label of product.

Description

This document explains the setup and configuration of the Intermatic model ET9500 BEMS INTERFACE BOX (Gateway). The ET9500 allows for remote control (via computer application) of the circuits on the ET90000 series time switches through various forms of communication. The communication protocols are the following: BACnet®, Modbus, and Metasys® N2.
Follow these instructions to complete the installation of the ET9500 BEMS INTERFACE BOX (Gateway).

FCC

Federal Communications Commission (FCC) Notice for ET9500 BEMS INTERFACE BOX

This device complies with part 15 of the FCC rules. Operation of this device is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses and radiates radio frequency energy and, if not installed and used in accordance with instructions, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference that requires the user to correct at his or her own expense.
BACnet® is a registered trademark of ASHRAE.
Metasys® is a registered trademark of Johnson Controls, Inc.

Mounting and Installation

  1. Install mounting brackets to enclosure. (See instruction sheet included within included brackets)

  2. Securely mount enclosure to desired location using hardware capable of supporting the ET9500.
    Note : Unit must be mounted vertically (upright) on a surface or structure capable of supporting the unit. Space must be provided for the enclosure door to fully swing open.

  3. Remove and retain dead front and hardware from the ET9500.

  4. Choose and remove the selected knockout(s) for AC input and gateway connections from enclosure.
    Note : There are ½ inch and ¾ inch knockouts available. If a ¾ inch knockout is needed, remove the ½ inch knockout first and the ¾ inch outer ring. Smooth edge if necessary.

  5. Use appropriately rated fittings for installation.

  6. Strip supply wires to ½”.

  7. Connect wires to proper terminals on the gateway and firmly tighten making sure no insulation is crimped in terminal.

  8. Connect ground wire to ground screw and firmly tighten making sure no insulation is crimped in terminal.

  9. Replace dead front and secure with screws removed earlier.

  10. Connect ethernet or RS 485 cable to the Gateway module. See included Quick Start Guide for connection guidance.

DIMENSION

INTERMATIC-ET9500 1-Circuit-Electronic-Control-FIG-
\(4\)

LIMITED THREE-YEAR WARRANTY

If within the warranty period specified, this product fails due to a defect in material or workmanship, Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is extended to the original purchaser only and is not transferable. This warranty does not apply to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modified; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the product; (e) sealed lamps and/or lamp bulbs, LED’s and batteries; (f) the finish on any portion of the product, such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage, initial installation costs, removal costs, or reinstallation costs.
INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.
This warranty service is available by either (a) returning the product to the dealer from whom the unit was purchased or (b) completing a warranty claim online at www.intermatic.com. This warranty is made by: Intermatic Incorporated, Customer Service 7777 Winn Rd., Spring Grove, Illinois 60081-9698. For warranty service go to: http://www.Intermatic.com or call 815-675-7000.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Intermatic User Manuals

Related Manuals