Hotpoint AH12H12D3B PTAC Heat Pump
Product Information
- Model: AH12H12D3B
- Dimensions and Installation Information (in inches):
- Wall Case Dimensions:
- A: 30 inches
- C: 70 inches
- Wall Opening Dimensions: Add 1/4 to A and C dimensions for all cut-outs.
- RAB80 Minimum H x Minimum W: 16-1/4 inches x 42-1/4 inches
- AH12 Electric Heater 230/208 Volt Line Cord Connected Units:
- Heater Watts: 3,500 / 2,897
- Heater BTU: 10,900 / 8,900
- Heater Amps: 15.3 / 13.7
- Min Circuit: 20 amps
- Recommended Protective Device: 20 amp time-delay fuse or breaker
- AH12 Heat Pump:
- Heat Pump Watts: 895 / 855
- Heat Pump BTU: 10,800 / 10,500
- COP: 3.2
Product Usage Instructions
To install the AH12H12D3B unit, follow these steps:
- Measure the wall opening dimensions and ensure they meet the minimum requirements of 16-1/4 inches in height and 42-1/4 inches in width.
- Add 1/4 inch to both the A and C dimensions to account for all cut-outs in the wall.
- Prepare the wall opening according to the measured dimensions.
- Place the AH12H12D3B unit into the wall opening, ensuring a secure fit.
- If using the electric heater function, connect the unit to a 230/208 volt power source using the provided line cord.
- For proper operation of the electric heater, ensure that the circuit is rated for a minimum of 20 amps. Install a 20 amp time-delay fuse or breaker as the recommended protective device.
- If using the heat pump function, connect the unit to a suitable power source.
- Refer to the product manual for further instructions on operating the AH12H12D3B unit.
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRICAL WIRING
- All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.
NOTE: Aluminum wiring may pose special problems – consult a qualified electrician.
GRILLE OPTIONS
- Stamped Aluminum Grille – RAG70
ELECTRICAL CONNECTION
- 230/208 volt units must be plugged into a receptacle. Installation must comply with local electrical codes and regulations.
- Power cord is permanently attached on all Hotpoint chassis.
AH12 ELECTRIC HEATER
230/208 VOLT| LINE CORD CONNECTED UNITS
Heater Watts| 3,500 / 2,897
Heater BTU| 10,900 / 8,900
Heater Amps| 15.3 / 13.7
Min Circuit| 20
Recommended protective Device| 20 amp time-delay fuse or breaker
AH12 HEAT PUMP
Heat Pump Watts| 895 / 855
Heat Pump BTU| 10,800 / 10,500
COP| 3.2
WALL CASE DIMENSIONS
RAB80 WALL SLEEVE
Heavy-gauge galvanized steel, with insulation, for quick self-assembly. A –
42”, B – 13-3/4”, C – 16”
MAXIMUM CORD EXTENSION
WALL OPENING DIMENSIONS
Add 1/4” to A and C dimensions for all cut-outs.
RAB80 16-1/4” Min. H x 42-1/4” Min. W
FEATURE AND BENEFITS
-
12,000 / 11,800 cooling BTU
-
10.5 EER
-
10,800 / 10,500 heating BTU
-
3.2 COP
-
R32 Refrigerant – Environmental friendly, low GWP (Global Warming Potential)
-
3-Speed Fan – Give guests control over their comfort with three fan speeds to choose from
-
4-Temperature Limiting Options – Easily select one of four temperature ranges for peak efficiency and total customer comfort
-
Intuitive Display – Allow guests to easily customize their preferred settings and reduce maintenance calls with an easy-to-use control panel
-
Power Cord (LCDI) Included – Hotpoint PTACs come with everything needed for a quick and easy installation
-
Automatic Emergency Heat – Keep guests comfortable with
a heating option that uses electric resistance heat in heat pump mode -
Freeze and Frost Protection – Automatic freeze and indoor frost control keep units operating in peak condition
-
Auto Power Recovery – In case of power failures, units automatically resume their operation when power restores, reducing maintenance calls
-
Self Diagnostics – Quickly and easily identify service needs with a nine-point diagnostic code system
-
Backed by an Industry Leader – With a long history of creating durable products at an affordable price, Hotpoint is your trusted PTAC brand
PRELIMINARY SPECIFICATIONS – SUBJECT TO CHANGE