Hotpoint AH12H07D3B PTAC Heat Pump Instructions

June 12, 2024
Hotpoint

Hotpoint AH12H07D3B PTAC Heat Pump

Product Information

  • Product Model: AH12H07D3B
  • Product Type: Electric Heater and Heat Pump

Electric Heater Specifications:

  • Watts: 3,500 / 2,897
  • BTU: 10,900 / 8,900
  • Amps: 15.3 / 13.7
  • Minimum Circuit: 20 amps
  • Recommended Protective Device: 20 amp time-delay fuse or breaker

Heat Pump Specifications:

  • Watts: 485 / 465
  • BTU: 6,200 / 6,000
  • COP: 3.6

Product Usage Instructions

Dimensions and Installation: Wall Case Dimensions:

  • A Dimension: 30 inches
  • C Dimension: 70 inches

Maximum Cord Extension: 30 inches Wall Opening Dimensions:

  • Add 1/4 inch to A and C dimensions for all cut-outs.
  • RAB80 Minimum Height: 16-1/4 inches
  • RAB80 Minimum Width: 42-1/4 inches

Electric Heater Usage: For the electric heater unit:

  • Connect the unit to a 230/208 volt line cord.
  • Ensure the minimum circuit is 20 amps.
  • Use a 20 amp time-delay fuse or breaker as a recommended protective device.

Heat Pump Usage: For the heat pump unit:

  • Connect the unit to the power supply.
  • Follow the provided electrical specifications.

AH12H07D3B
Hotpoint® PTAC Heat Pump Unit with Electric Heat Backup 20 amps, 230/208 Volt

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES) ELECTRICAL WIRING

All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.
NOTE: Aluminum wiring may pose special problems – consult a qualified electrician.

GRILLE OPTIONS
Stamped Aluminum Grille – RAG70

ELECTRICAL CONNECTION

  • 230/208 volt units must be plugged into a receptacle. Installation must comply with local electrical codes and regulations.
  • Power cord is permanently attached on all Hotpoint chassis.

WALL CASE DIMENSIONS
RAB80 WALL SLEEVE

Heavy-gauge galvanized steel, with insulation, for quick self-assembly. A – 42”, B – 13-3/4”, C – 16”

MAXIMUM CORD EXTENSION
WALL OPENING DIMENSIONS

  • Add 1/4” to A and C dimensions for all cut-outs.
  • RAB80 16-1/4” Min. H x 42-1/4” Min. W

AH12 ELECTRIC HEATER

230/208 VOLT| LINE CORD CONNECTED UNITS
Heater Watts| 3,500 / 2,897
Heater BTU| 10,900 / 8,900
Heater Amps| 15.3 / 13.7
Min Circuit| 20
Recommended protective Device| 20 amp time-delay fuse or breaker
AH12 HEAT PUMP
Heat Pump Watts| 485 / 465
Heat Pump BTU| 6,200/6,000
COP| 3.6

FEATURE AND BENEFITS

  • 7,300 / 7,200 cooling BTU
  • 12.9 / 13.0 EER
  • 6,200 / 6,000 heating BTU
  • 3.6 COP
  • R32 Refrigerant – Environmental friendly, low GWP (Global Warming Potential)
  • 3-Speed Fan – Give guests control over their comfort with three fan speeds to choose from
  • 4-Temperature Limiting Options – Easily select one of four temperature ranges for peak efficiency and total customer comfort
  • Intuitive Display – Allow guests to easily customize their preferred settings and reduce maintenance calls with an easy-to-use control panel
  • Power Cord (LCDI) Included – Hotpoint PTACs come with everything needed for a quick and easy installation
  • Automatic Emergency Heat – Keep guests comfortable with a heating option that uses electric resistance heat in heat pump mode
  • Freeze and Frost Protection – Automatic freeze and indoor frost control keep units operating in peak condition
  • Auto Power Recovery – In case of power failures, units automatically resume their operation when power restores, reducing maintenance calls
  • Self Diagnostics – Quickly and easily identify service needs with a nine-point diagnostic code system
  • Backed by an Industry Leader – With a long history of creating durable products at an affordable price, Hotpoint is your trusted PTAC brand

PRELIMINARY SPECIFICATIONS – SUBJECT TO CHANGE