Hotpoint RGBS400DMBB Free-Standing Standard Clean Gas Range Instruction Manual
- June 12, 2024
- Hotpoint
Table of Contents
- IN THE COMMONWEALTH OF MASSACHUSETTS
- FIRE OR EXPLOSION HAZARD
- FOR YOUR SAFETY
- TOOLS YOU WILL NEED
- MATERIALS YOU MAY NEED
- BEFORE YOU BEGIN
- DIMENSIONS AND CLEARANCES
- DIMENSIONS AND CLEARANCES (CONT.)
- CONVERTING TO PROPANE
- INSTALLATION AT HIGH ALTITUDE
- GAS SUPPLY
- ELECTRICAL CONNECTIONS
- SURFACE BURNERS
- CHECK SURFACE BURNERS
- CHECK BAKE AND BROIL BURNERS
- INSTALL AND CHECK ANTI-TIP DEVICE
- LEVEL THE RANGE
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
Hotpoint RGBS400DMBB Free-Standing Standard Clean Gas Range
IN THE COMMONWEALTH OF MASSACHUSETTS
- This product must be installed by a licensed plumber or gas fitter.
- When using ball type gas shut-off valves, they shall be the T-handle type.
- A flexible gas connector, when used, must not exceed 5 feet.
FIRE OR EXPLOSION HAZARD
If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. Installation must be performed by a qualified installer.
Read these instructions completely and carefully. Installation of this range must conform with local codes, or in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 / NFPA.54, latest edition. In Canada, installation must conform with the current Natural Gas Installation Code, CAN/CGA-B149.1 or the current Propane Installation Code, CAN/CGAB149.2, and with local codes where applicable. This range has been design-certified by CSA International according to ANSI Z21.1 , latest edition and Canadian Gas Association according to CAN/CGA-1 .1 latest edition.
When installing a gas appliance the use of old flexible connectors can cause gas leaks and personal injury. Always use a NEW flexible connector.
Leak testing of the appliance shall be conducted according to the manufacturer instructions.
The range must be electrically grounded in accordance with local codes or, in the absence of local codes, in accordance with the National Electrical Code (ANSI/NFPA 70, latest edition). In Canada, electrical grounding must be in accordance with the current CSA C22.1 Canadian Electrical Code Part 1 and/or local codes. See Electrical Connections in this section.
Do not install this product with an air curtain hood or other range hood that operates by blowing air down on the cooktop. This airflow may interfere with operation of the gas burners resulting in fire or explosion hazard.
FOR YOUR SAFETY
|
---|---
Tio-Over Hazard
- A child or adult can tip the range and be killed.
- Install the anti-tip bracket to the wall or floor. Engage the range to the anti-tip bracket by sliding the range back such that the foot is engaged.
- Re-engage the anti-tip bracket if the range is moved.
- Failure to do so can result in death or serious burns to children or adults.
If you did not receive an anti-tip bracket with your purchase, call 1.800.626.8774 to receive one at no cost. (In Canada, call 1.800.561 .3344.) For installation instructions of the bracket, visit: GEAppliances.com. (In Canada, GEAppliances.ca.)
Anti-Tip Bracket Kit Included
Before beginning the installation , switch power off at service panel and lock
the service disconnecting means to prevent power from being switched on
accidentally. When the service disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to the service panel.
TOOLS YOU WILL NEED
-
Phillips screwdriver
-
Flat-blade screwdriver
-
Pencil and ruler
-
Pipe wrenches (2) (one for backup)
-
Open-end or adjustable wrench
-
Level
-
Drill, awl or nail
MATERIALS YOU MAY NEED
-
Gas line shut-off valve
-
Pipe joint sealant or UL-approved pipe thread tape with Teflon* that resists action of natural and propane gases
-
Flexible metal appliance connector (1/2″ 1.0.).
A 5-foot length is recommended for ease of installation but other lengths are acceptable.
Never use an old connector when installing a new range. -
Flare union adapter for connection to gas supply line (3/4″ or 1/2″ NPT x 1/2″ 1.0.)
-
Flare union adapter for connection to pressure regulator on range (1/2″ NPT x 1/2″ 1.0.)
-
Liquid leak detector or soapy water.
*Teflon: Registered trademark of DuPont
BEFORE YOU BEGIN
IMPORT ANT – Save these instructions for local inspector’s use.
IMPORT ANT – Observe all governing codes and ordinances.
IMPORT ANT – Remove all packing material and literature from oven before connecting gas and electrical supply to range.
IMPORT ANT – To avoid damage to your cabinets, check with your builder or cabinet supplier to make sure that the materials used will not discolor, delaminate or sustain other damage. This oven has been designed in accordance with the requirements of UL and CSA International and complies with the maximum allowable wood cabinet temperatures of 194°F (90°C).
Note to Installer – Be sure to leave these instructions with consumer.
Note to consumer – Keep these instructions for future reference.
Servicer – The electrical diagram is in an envelope attached to the back of the range.
Proper installation is the responsibility of the installer.
Product failure due to improper installation is not covered under warranty.
Before installing your range on linoleum or any other synthetic floor covering, make sure the floor covering can withstand 180°F without shrinking, warping or discoloring. Do not install the range over carpeting unless a sheet of 1/4″ thick plywood or similar insulator is placed between the range and carpeting.
Mobile Home – Additional Installation Requirements
The installation of this range must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile
Home Construction and Safley, Title 24, HUD Part 280). When such standard is not applicable, use the Standard for Manufactured
Home Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the current standards CAN/CSAA240- latest edition, or with local codes.
When this range is installed in a mobile home, it must be secured to the floor during transit. Any method of securing the range is adequate as long as it conforms to the standards listed above.
DIMENSIONS AND CLEARANCES
Provide adequate clearances between the range and adjacent combustible surfaces. These dimensions must be met for safe use of your range.
Allow 30″ (76.2 cm) minimum clearance between burners and bottom of unprotected wood or metal cabinet, or allow a 24″ (61 cm) minimum when bottom of wood or metal cabinet is protected by no less than 1/4″ (6.4 mm) thick flame-retardant millboard covered with no less than No. 28 MSG sheet metal (.015″ [.38 mm] thick), .015″ (.38 mm) thick stainless steel, .025″ (0.64 mm) aluminum or .020″ (0.5 mm) copper.
Installation of a listed microwave oven or cooking appliance over the cooktop shall conform to the installation instructions packed with that appliance.
For island installation, maintain 2-1/2″ minimum from cutout to back edge of countertop and 3″ minimum from cutout to side edges of countertop.
DIMENSIONS AND CLEARANCES (CONT.)
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
To prevent drafts from affecting burner operation, seal all openings in floor
under appliance and behind appliance wall.
CONVERTING TO PROPANE
GAS (OR CONVERTING BACK TO NATURAL GAS FROM PROPANE)
This range leaves the factory set for use with natural gas. If you want to
convert to propane gas, the conversion must be performed by a qualified
propane gas installer.
The conversion orifices and instructions can be found on back of the range.
Keep these instructions and all orifices in case you want to convert back to
natural gas.
INSTALLATION AT HIGH ALTITUDE
Over 6000ft, product configured for natural gas or propane requires installation of kit (WB49X25441 for natural gas and WB49X25442 for propane gas). Follow the instructions included with the kit.
GAS SUPPLY
Fire Hazard: Do not use a flame to check for gas leaks.
Explosion Hazard: Do not exceed 25 ft-lbs of torque when making gas line
connections. Overtightening may crack the pressure regulator resulting in fire
or explosion hazard.
Gas Pressure Regulator
You must use the gas pressure regulator supplied with this range. For proper operations the inlet pressure to the regulator should be as follows:
Natural Gas:
Minimum pressure: 6″ of Water Column
Maximum pressure: 13″ of Water Column
Propane Gas:
Minimum pressure: 11 ” of Water Column
Maximum pressure: 13″ of Water Column
If you are not sure about the inlet pressure contact local gas supplier.
Shut off the main gas supply valve before disconnecting the old range and leave it off until the new hook-up has been completed. Don’t forget to relight the pilot on other gas appliances when you turn the gas back on. Because hard piping restricts movement of the range, the use of a CSA International certified flexible metal appliance connector is recommended unless local codes require a hard-piped connection.
If the hard piping method is used, you must carefully align the pipe; the range cannot be moved after the connection is made.
To prevent gas leaks, put pipe joint compound on, or wrap pipe thread tape with Teflon* around, all male (external) pipe threads.
A. Install a manual shut-off valve in the gas line in an easily accessed
location outside of the range. Make sure everyone operating the range knows
where and how to shut off the gas supply to the range.
B. Install male 1/2″ flare union adapter to the 1 /2″ NPT internal thread
at inlet of regulator. Use a backup wrench on the regulator fitting to avoid
damage.
C. Install male 1/2″ or 3/4″ flare union adapter to the NPT internal
thread of the manual shut-off valve, taking care to back-up the shut-off valve
to keep it from turning.
D. Connect flexible metal appliance connector to the adapter on the
range. Position range to permit connection at the shut-off valve.
E. When all connections have been made, make sure all range controls are
in the off position and turn on the main gas supply valve. Use a liquid leak
detector at all joints and connections to check for leaks in the system.
When using pressures greater than 1/2 psig to pressure test the gas supply system of the residence, disconnect the range and individual shut-off valve from the gas supply piping. When using pressures of 1 /2 psig or less to pressure test the gas supply system, simply isolate the range from the gas supply system by closing the individual shut-off valve.
When checking for proper operation of the regulator, the inlet pressure must be at least 1″ greater than the operating (manifold) pressure as given on rating label of product.
*Teflon: Registered trademark of DuPont
CONNECTOR HOOKUP
Installer: Inform the consumer of the location of the gas shut-off valve.
ELECTRICAL CONNECTIONS
Shock Hazard: This appliance must be properly grounded.
Failure to do so can result in electric shock.
Electrical Requirements – 120-volt, 60 Hertz, properly grounded circuit protected by a 15-amp or 20-amp circuit breaker or time delay fuse. It is recommended that a separate circuit serving only this range be provided.
Note: Use of automatic, wireless, or wired external switches that shut off power to the appliance are not recommended for this product.
Grounding
The power cord of this appliance is equipped with a three-prong (grounding) plug which plugs into a standard three-prong grounding wall receptacle to minimize the possibility of electric shock hazard from this appliance.
The customer should have the wall receptacle and circuit checked by a qualified electrician to make sure the receptacle is properly grounded.
Where a standard two-prong wall receptacle is encountered, it is the personal responsibility and obligation of the customer to have it replaced with a properly grounded three-prong wall receptacle.
DO NOT, UNDER ANY CIRCUMSTANCES, CUT OR REMOVE THE THIRD {GROUND) PRONG FROM THE POWER CORD. DO NOT USE AN ADAPTER. DO NOT USE AN EXTENSION CORD.
Ground Fault Circuit Interrupters (GFCl’s) are not required or recommended for gas range receptacles. Performance of the range will not be affected if operated on a GFCl-protected circuit but occasional nuisance tripping of the GFCI breaker is possible.
SURFACE BURNERS
Fire or Explosion Hazard:
Do not operate the burner without all burner parts in place.
A. Burners – Place surface burners into corresponding positions on
cooktop.
B. Caps – Place caps on proper size burner.
C. Grates – The left and right grates are interchangeable. Place the
grates on the cooktop.
CHECK SURFACE BURNERS
Push and turn a knob to the LITE position. A clicking sound indicates proper operation of the ignition system. When lighting any burner, sparks will appear at all burners but gas flows from only the one selected. Once air is purged from the supply line, burner should light within 4 seconds. After burner lights, rotate the knob out of the LITE position. Try each burner in succession until all burners have been checked.
Quality of Flames
Determine the quality of flames visually. Normal burner flames should look like (A) or (B).
(A) Soft blue flames Normal for natural gas
(B) Yellow tips on outer cones- Normal for propane gas
Long, bright yellow flames are not normal. Normal flames may show signs of an orange tint when well heated or signs of flickering orange due to particles in the gas or air.
CHECK BAKE AND BROIL BURNERS
- Set Bake function to 350°F. Burner should light in 30 to 60 seconds.
- Set broil to Broil Hi. Burner should light in 30 to 60 seconds.
INSTALL AND CHECK ANTI-TIP DEVICE
Never completely remove the leveling leg as the range will not be secured
to the anti-tip device properly.
Follow instructions supplied with ANTI-TIP bracket.
Anti-Tip Bracket Kit Included
LEVEL THE RANGE
Never completely remove the leveling leg as the range will not be secured
to the anti-tip device properly.
A. Plug in the unit.
B. Measure the height of your countertop at the rear of the opening (X).
C. Adjust two rear leveling legs so that the rear of cooktop is at the
same height or higher than the counter (Y).
D. Slide unit into place.
E. Install oven shelves in the oven and position the range where it will
be installed.
F. Check for levelness by placing a spirit level on one of the oven
shelves. Take two readings-with the level placed diagonally first in one
direction and then the other.
G. Adjust front leveling legs until the range is level.
H. Look under the unit and verify that the rear leg is fully engaged with
the anti-tip device. If not, remove the unit and adjust the height of the rear
leg so that it is properly engaged.
WHEN ALL HOOKUPS ARE COMPLETED
Make sure all controls are left in the off position. Make sure the flow of combustion and ventilation air to the range is unobstructed.
Check that all packing materials and tape have been removed. This will include tape on metal panel under control knobs (if applicable), adhesive tape, wire ties, cardboard and protective plastic. Failure to remove these materials could result in damage to the appliance once the appliance has been turned on and surfaces have heated.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>