Hotpoint AH12E12D3B PTAC with Electric Heat 20 Amps Owner’s Manual

June 12, 2024
Hotpoint

Hotpoint AH12E12D3B PTAC with Electric Heat 20 Amps

Hotpoint-AH12E12D3B-PTAC-with-Electric-Heat-20-Amps-
PRODUCT

Product Information

  • Model: AH12E12D3B
  • Dimensions: A = 30 inches, C = 70 inches
  • Wall Case Dimensions: RAB80 16-1/4″ Min. H x 42-1/4″ Min. W
  • Maximum Cord Extension: 30 inches
  • Heater Watts: 3,500 / 2,897
  • Heater BTU: 10,900 / 8,900
  • Heater Amps: 15.3 / 13.7
  • Min Circuit: 20 amps
  • Recommended Protective Device: 20 amp time-delay fuse or breaker
  • Revision: 31-5000814 Rev. 0
  • Date: 07-23

Product Usage Instructions

  1. Measure and mark the wall opening dimensions based on the provided A and C dimensions.
  2. Add 1/4 inch to both A and C dimensions for all cut-outs.
  3. Ensure the wall opening dimensions are at least 16-1/4 inches in height and 42-1/4 inches in width for the wall case.
  4. Connect the unit to a 230/208 volt line using a cord.
  5. Ensure the line cord is extended up to a maximum of 30 inches.
  6. Refer to the provided heater watts and amps information to determine the electrical requirements.
  7. Install a dedicated circuit with a minimum rating of 20 amps for the heater.
  8. Use a recommended protective device such as a 20 amp time-delayfuse or breaker.

DIMENSIONS AND INSTALLATION

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)

WALL CASE DIMENSIONS
RAB80 WALL SLEEVE Heavy-gauge galvanized steel, with insulation, for quick self-assembly. A – 42”, B – 13-3/4”, C – 16”

MAXIMUM CORD EXTENSION
WALL OPENING DIMENSIONS Add 1/4” to A and C dimensions for all cut-outs. RAB80 16-1/4” Min. H x 42-1/4” Min. WHotpoint-AH12E12D3B-PTAC-with-Electric-
Heat-20-Amps-FIG- \(2\)

ELECTRICAL WIRING

All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.
NOTE : Aluminum wiring may pose special problems – consult a qualified electrician.

GRILLE OPTIONS

Stamped Aluminum Grille – RAG70

ELECTRICAL CONNECTION

  • 230/208 volt units must be plugged into a receptacle. Installation must comply with local electrical codes and regulations.
  • Power cord is permanently attached on all Hotpoint chassis.

SPECIFICATION

AH12 ELECTRIC HEATER

230/208 VOLT| LINE CORD CONNECTED UNITS
Heater Watts| 3,500 / 2,897
Heater BTU| 10,900 / 8,900
Heater Amps| 15.3 / 13.7
Min Circuit| 20
Recommended protective Device| 20 amp time-delay fuse or breaker

FEATURE AND BENEFITS

Hotpoint-AH12E12D3B-PTAC-with-Electric-Heat-20
-Amps-FIG- \(3\)

  • 12,000 / 11,800 cooling BTU
  • 10.7 EER
  • R32 Refrigerant – Environmental friendly, low GWP (Global Warming Potential)
  • 3-Speed Fan – Give guests control over their comfort with three fan speeds to choose from
  • 4-Temperature Limiting Options – Easily select one of four temperature ranges for peak efficiency and total customer comfort
  • Intuitive Display – Allow guests to easily customize their preferred settings and reduce maintenance calls with an easy-to-use control panel
  • Power Cord (LCDI) Included – Hotpoint PTACs come with everything needed for a quick and easy installation
  • Automatic Emergency Heat – Keep guests comfortable with a heating option that uses electric resistance heat in heat pump mode
  • Freeze and Frost Protection – Automatic freeze and indoor frost control keep units operating in peak condition
  • Auto Power Recovery – In case of power failures, units automatically resume their operation when power restores, reducing maintenance calls
  • Self Diagnostics – Quickly and easily identify service needs with a nine-point diagnostic code system
  • Backed by an Industry Leader – With a long history of creating durable products at an affordable price, Hotpoint is your trusted PTAC brand

PRELIMINARY SPECIFICATIONS – SUBJECT TO CHANGE

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Hotpoint User Manuals

Related Manuals