Hotpoint AH12H09D3B PTAC Heat Pump Instruction Manual

June 12, 2024
Hotpoint

Hotpoint AH12H09D3B PTAC Heat Pump

Hotpoint-AH12H09D3B-PTAC-Heat-Pump-FIG- \(5\)

Product Information

The AH12H09D3B is a combination unit that includes an electric heater and a heat pump. It operates at 230/208 volts and is designed for line cord connection. The unit has a heater with a power rating of 3,500 watts (10,900 BTU) at 230 volts and 2,897 watts (8,900 BTU) at 208 volts. The heater requires a minimum circuit of 20 amps and is recommended to be protected by a 20 amp time-delay fuse or breaker.
In addition to the electric heater, the AH12H09D3B also features a heat pump. The heat pump has a power rating of 720 watts (8,400 BTU) at 230 volts and 690 watts (8,200 BTU) at 208 volts. It has a COP (Coefficient of Performance) of 3.4. This combination unit provides both heating and cooling capabilities.

Product Usage Instructions

Dimensions and Installation:

  • Wall Case Dimensions: A = 30 inches, C = 70 inches
  • Maximum Cord Extension: 30 inches
  • Wall Opening Dimensions: Add 1/4 inch to A and C dimensions for all cut-outs
  • RAB80 Minimum Dimensions: Height = 16-1/4 inches, Width = 42-1/4 inches

Electric Heater:

  • Ensure the unit is connected to a power source with the appropriate voltage (230/208 volts)
  • Make sure the circuit supplying power to the unit is at least 20 amps
  • Use a 20 amp time-delay fuse or breaker to protect the heater

Heat Pump:

  • Connect the unit to a power source with the appropriate voltage (230/208 volts)
  • The heat pump has a power rating of 720 watts (8,400 BTU) at 230 volts and 690 watts (8,200 BTU) at 208 volts
  • The COP of the heat pump is 3.4

Please refer to the user manual for complete installation, operation, and maintenance instructions.
Hotpoint® PTAC Heat Pump Unit with Electric Heat Backup 15 amps, 230/208 Volt

DIMENSIONS AND INSTALLATION

DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)+

WALL CASE DIMENSIONS
RAB80 WALL SLEEVE Heavy-gauge galvanized steel, with insulation, for quick self-assembly. A – 42”, B – 13-3/4”, C – 16”

MAXIMUM CORD EXTENSION
WALL OPENING DIMENSIONS Add 1/4” to A and C dimensions for all cut-outs. RAB80 16-1/4” Min. H x 42-1/4” Min. W

ELECTRICAL WIRING

All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.
NOTE : Aluminum wiring may pose special problems – consult a qualified electrician.

GRILLE OPTIONS

  • Stamped Aluminum Grille – RAG70

ELECTRICAL CONNECTION

230/208 volt units must be plugged into a receptacle. Installation must comply with local electrical codes and regulations.
Power cord is permanently attached on all Hotpoint chassis

SPECIFICATION

AH12 ELECTRIC HEATER

230/208 VOLT| LINE CORD CONNECTED UNITS
Heater Watts| 3,500 / 2,897
Heater BTU| 10,900 / 8,900
Heater Amps| 15.3 / 13.7
Min Circuit| 20
Recommended protective Device| 20 amp time-delay fuse or breaker
AH12 HEAT PUMP
Heat Pump Watts| 720 / 690
Heat Pump BTU| 8,400 / 8,200
COP| 3.4

FEATURE AND BENEFITS

Hotpoint-AH12H09D3B-PTAC-Heat-Pump-FIG-
\(3\)

  • 9,500 / 9,500 cooling BTU
  • 11.4 EER
  • 8,400 / 8,200 heating BTU
  • 3.4 COP
  • R32 Refrigerant – Environmental friendly, low GWP (Global Warming Potential)
  • 3-Speed Fan – Give guests control over their comfort with three fan speeds to choose from
  • 4-Temperature Limiting Options – Easily select one of four temperature ranges for peak efficiency and total customer comfort
  • Intuitive Display – Allow guests to easily customize their preferred settings and reduce maintenance calls with an easy-to-use control panel
  • Power Cord (LCDI) Included – Hotpoint PTACs come with everything needed for a quick and easy installation
  • Automatic Emergency Heat – Keep guests comfortable with a heating option that uses electric resistance heat in heat pump mode
  • Freeze and Frost Protection – Automatic freeze and indoor frost control keep units operating in peak condition
  • Auto Power Recovery – In case of power failures, units automatically resume their operation when power restores, reducing maintenance calls
  • Self Diagnostics – Quickly and easily identify service needs with a nine-point diagnostic code system
  • Backed by an Industry Leader – With a long history of creating durable products at an affordable price, Hotpoint is your trusted PTAC brand

PRELIMINARY SPECIFICATIONS – SUBJECT TO CHANGE

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals