Hotpoint AH12H15D3B PTAC Heat Pump Unit Instruction Manual
- June 12, 2024
- Hotpoint
Table of Contents
AH12H15D3B
Hotpoint® PTAC Heat Pump Unit with Electric Heat Backup 20 amps, 230/208
Volt
DIMENSIONS AND INSTALLATION INFORMATION (IN INCHES)
ELECTRICAL WIRING
- All wiring, including installation of receptacle, must be made in accordance with local electrical codes and regulations.
NOTE: Aluminum wiring may pose special problems – consult a qualified electrician.
GRILLE OPTIONS
- Stamped Aluminum Grille – RAG70
ELECTRICAL CONNECTION
- 230/208 volt units must be plugged into a receptacle. Installation must comply with local electrical codes and regulations.
- Power cord is permanently attached on all Hotpoint chassis.
WALL CASE DIMENSIONS
RAB80 WALL SLEEVE
Heavy-gauge galvanized steel, with insulation, for quick self-assembly.
A – 42”, B – 13-3/4”, C – 16”
MAXIMUM CORD EXTENSION
WALL OPENING DIMENSIONS
Add 1/4” to A and C dimensions for all cut-outs.
RAB80 16-1/4” Min. H x 42-1/4” Min. W
AH12 ELECTRIC HEATER
230/208 VOLT| LINE CORD CONNECTED UNITS
Heater Watts| 3,500 / 2,897
Heater BTU| 10,900 / 8,900
Heater Amps| 15.3 / 13.7
Min Circuit| 20
Recommended protective Device| 20 amp time-delay fuse or breaker
FEATURE AND BENEFITS
- 9,200 / 9,000 cooling BTU
- 11.3 EER
- R32 Refrigerant – Environmental friendly, low GWP (Global Warming Potential)
- 3-Speed Fan – Give guests control over their comfort with three fan speeds to choose from
- 4-Temperature Limiting Options – Easily select one of four temperature ranges for peak efficiency and total customer comfort
- Intuitive Display – Allow guests to easily customize their preferred settings and reduce maintenance calls with an easy-to-use control panel
- Power Cord (LCDI) Included – Hotpoint PTACs come with everything needed for a quick and easy installation
- Automatic Emergency Heat – Keep guests comfortable with a heating option that uses electric resistance heat in heat pump mode
- Freeze and Frost Protection – Automatic freeze and indoor frost control keep units operating in peak condition
- Auto Power Recovery – In case of power failures, units automatically resume their operation when power restores, reducing maintenance calls
- Self Diagnostics – Quickly and easily identify service needs with a nine-point diagnostic code system
- Backed by an Industry Leader – With a long history of creating durable products at an affordable price, Hotpoint is your trusted PTAC brand