LEDONE LOC-GDHB Series high bay light Installation Guide

June 4, 2024
LEDone

LEDONE LOGO LOC-GDHB Series
Installation Guide

SAFETY INSTRUCTIONS:

Read instructions carefully before attempting to install the fixture.

  • All wiring should be performed by a qualified electrician.
  • Disconnect power before installing or servicing. This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances.
  • Proper grounding is required to ensure personal safety.

CAUTION: Risk of fire

  • WARNING: Make certain power is OFF before installing or maintaining the fixture. No user-serviceable parts inside.
  • WARNING: Risk of shock when the photoelectric switch is provided.
  • WARNING: Please check if the voltage marked on the luminaire is consistent with the input voltage to be connected.
  • WARNING: Do NOT use in an area with strong acid mist.
  • WARNING: Make sure the installation position can withstand 10 times the weight of the luminaire before installing.
    • Install it at a flat place without vibration, swinging, or fire hazards.

CLEANING & MAINTENANCE:

CAUTION: Be sure the fixture temperature is cool enough to touch. Do NOT clean or maintain while the fixture is energized.

  1. Clean glass lens with a non-abrasive glass cleaning solution.
  2. Do NOT open the fixture to clean the LED. Do NOT touch the LED.

Note: These instructions do not cover all details or variations in equipment, nor do they provide for every possible situation during installation, operation, or maintenance.

TROUBLESHOOT:

  • If the light will not come on:
    • A. Light switch is turned off. Turn the light switch on.
    • B. Fuse is blown, or circuit breaker is turned off. Replace the fuse or turn the circuit breaker on.
    • C. Incorrect circuit wiring. Verify that fixture is wired properly.

WIRING:

Universal voltage driver permits operation at 120V through 347V, 50/60Hz. Follow wiring directions as in Fig. 1.

  1. Connect the BLACK fixture lead to the (+) LINE supply lead.
  2. Connect the WHITE fixture lead to the (-) COMMON supply lead.
  3. Connect the GROUND wire from the fixture to the supply ground.

LEDONE LOC GDHB Series high bay light - FIG 1

0-10V DIMMABLE WIRING:
Universal voltage driver permits operation at 120V through 347V, 50/60Hz. A 5-wire cord is provided. For 0-10V dimming, follow the wiring instructions in Fig. 2.

  1. Connect the BLACK fixture lead to the (+) LINE supply lead.
  2. Connect the WHITE fixture lead to the (-) COMMON supply lead.
  3. Connect the GROUND wire from the fixture to the supply ground. Do NOT connect the GROUND of the dimming fixture to the output.
  4. Connect the PURPLE fixture lead to the (V+) DIM lead.
  5. Connect the GRAY fixture lead to the (V-) DIM lead.
  6. Cap the YELLOW fixture lead, if present. Do NOT connect.

MOUNTING:

1. HOOK MOUNTING: Follow mounting directions as in Fig. 3 to 6
a. Fix the hook on the light. (clockwise rotation)
b. Use an electric drill to bore a hole in the wall.
c. Fix the hanger on the wall with screws.
d. Fix one end of the chain to the wall, another to the hook from the light, and complete installation.

LEDONE LOC GDHB Series high bay light - FIG 3LEDONE LOC GDHB Series high bay light - FIG
4 2. U-BRACKET MOUNTING: Follow mounting directions as in Fig. 7 to 10
a. Use an electric drill to bore 2 holes in the wall.
b. Set the expansion screws to the existing drilling holes.
c. Fix the u-bracket to the wall by nut, plain cushion, and spring shim.
d. Use a wrench to reverse the hexagon nut and adjust the requested angle.

LEDONE LOC GDHB Series high bay light - FIG 5LEDONE LOC GDHB Series high bay light - FIG
6

LEDONE LOGOPhone: (844) LEDONE6
Fax: 1-510-217-9461
Web: www.ledonecorp.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals