PASCO LXi2 Datalogger User Manual
- June 12, 2024
- PASCO
Table of Contents
Product Guide | 012-17261B
SPARK LXi2 Datalogger (PS-3600B)
Introduction
The SPARK LXi2 is a combination datalogging device and interface with a
ruggedized cover. It blends PASCO probeware with PASCO data collection and
analysis software programs.
The SPARK LXi2 features two PASPORT input ports, as well as ports for the
included temperature probe and voltage probe.
Components
-
Power button
Press and hold to turn the device on or off. -
PASPORT input 1
Use this port to connect a PASPORT sensor. -
Voltage input port
Use this port to connect the included Voltage Probe. -
USB-A communications port
Use this port to connect a USB device, such as a USB flash drive. -
Temperature Probe port
Use this port to connect the included Temperature Probe. -
PASPORT input 2
Use this port to connect a second PASPORT sensor. -
USB-C charging port
Connect the included USB charger to charge the battery. -
Battery Status LED
This light indicates the charging status of the battery. The light is yellow when the LXi2 is charging, turns green when fully charged, and blinks red when low on power. -
Camera
Use the camera to record images in SPARKvue. -
Headphone jacks
-
Volume control
Included equipment:
- SPARK LXi2 Datalogger
- Voltage Probe
- Fast Response Temperature Probe
- USB charger with USB cable
Charge the battery
Charge the SPARK LXi2’s battery overnight to ensure power for a full day’s
use. To charge the battery, connect the charging port to the included USB
charger via the USB cable. Fully power off the LXi2 to minimize power loss
between use, as the device will still lose some power while in sleep mode.
Connect sensors
Wireless
Connect to the device wirelessly through the SPARKvue or MatchGraph apps.
PASPORT
Plug a PASPORT Sensor into one of the PASPORT Input Ports.
The software will automatically identify the sensor.
Voltage and temperature ports
Plug the Voltage Probe into the voltage input port. Plug the temperature probe
into the Temperature Probe port. SPARKvue will automatically identify the
sensors.
SPARK LXi2 apps
The SPARK LXi2 comes with the following preinstalled apps:
SPARKvue
Use SPARKvue to collect and analyze data from Wireless and PASPORT sensors
connected to the SPARK LXi2.
MatchGraph
Use a Motion Sensor or a Smart Cart with MatchGraph to help engage students as
they interpret position and velocity graphs by making a game of it.
Spectrometry
Use Spectrometry with PASCO spectrometers to measure absorbance,
transmittance, intensity, and fluorescence.
Periodic Table
A period table that can be used for quick reference.
Calculator
A standard scientific calculator.
Files
Access the files contained on your SPARK LXi2 datalogger.
Set Up
Use this app to access various settings, including WiFi, Bluetooth, display,
and sound.
SPARK LXi Help
Use this help guide to learn more about the features and applications
contained on the SPARK LXi2 datalogger.
Technical support
Need more help? Our knowledgeable and friendly Technical Support staff is
ready to answer your questions or walk you through any issues.
Chat pasco.com
Phone 1-800-772-8700 x1004 (USA)
+1 916 462 8384 (outside USA)
Email support@pasco.com
You can also consult the PASCO Video Library at
www.pasco.com/resources/video for
additional help.
Warranty
For a description of the product warranty, see the Warranty and Returns page
at www.pasco.com/legal.
Copyright
This document is copyrighted with all rights reserved. Permission is granted
to nonprofit educational institutions for reproduction of any part of this
manual, providing the reproductions are used only in their laboratories and
classrooms, and are not sold for profit. Reproduction under any other
circumstances, without the written consent of PASCO scientific, is prohibited.
Trademarks
PASCO and PASCO scientific are trademarks or registered trademarks of PASCO
scientific, in the United States and in other countries. All other brands,
products, or service names are or may be trademarks or service marks of, and
are used to identify, products or services of, their respective owners. For
more information visit www.pasco.com/legal.
Product end-of-life disposal
This electronic product is subject to disposal and recycling regulations that
vary by country and region. It is your responsibility to recycle your
electronic equipment per your local environmental laws and regulations to
ensure that it will be recycled in a manner that protects human health and the
environment. To find out where you can drop off your waste equipment for
recycling, please contact your local waste recycle or disposal service, or the
place where you purchased the product. The European Union WEEE (Waste
Electronic and Electrical Equipment) symbol on the product or its packaging
indicates that this product must not be disposed of in a standard waste
container.
Battery disposal
Batteries contain chemicals that, if released, may affect the environment and
human health. Batteries should be collected separately for recycling and
recycled at a local hazardous material disposal location adhering to your
country and local government regulations. To find out where you can drop off
your waste battery for recycling, please contact your local waste disposal
service, or the product representative. The battery used in this product is
marked with the European Union symbol for waste batteries to indicate the need
for the separate collection and recycling of batteries.
CE statement
This device has been tested and found to comply with the essential
requirements and other relevant provisions of the applicable EU Directives.
FCC statement
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause
undesired operation.
Note 1: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of FCC rules. These
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses and
can radiate radio frequency energy and, if not installed and used in
accordance with the instructions, may cause harmful interference to radio
communications. However, there is no guarantee that interference will not
occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/TV technician for help.
NOTE 2: Any changes or modifications to this unit not expressly approved
by the party responsible for compliance could void the user’s authority to
operate the equipment.
NOTE 3: Operation in the band 5150–5250 MHz is only for indoor use to
reduce the potential for harmful interference to co-channel mobile satellite
systems.
RF exposure information and statement . this device meets government
requirements for exposure to radio waves. The guidelines are based on
standards that were developed by independent scientific organizations through
evaluation of scientific studies. The standards include a substantial safety
margin designed to assure the safety of all persons regardless of age or
health. The SAR limit of USA(FCC) is 1.6W/Kg averaged. Has also been tested
against this SAR limit. SAR information on this and other pad can be viewed
on-line at www.fcc.gov/oet/ea/fccid/.
Please use the device FCC ID number for search. This device was tested
simulation typical 0 mm to body. To maintain compliance with FCC RF exposure
requirements, the use of belt clips, holsters and similar accessories should
not contain metallic components in its assembly, the use of accessories that
do not satisfy these requirements may not comply with FCC RF exposure
requirements, and should be avoided.
ISED Canada compliance statement
This device complies with ISED Canada license-exempt RSS standard(s).
Operation is subject to the following two conditions: (1) this device may not
cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
Operation in the band 5150–5250 MHz is only for indoor use to reduce the
potential for harmful interference to co-channel mobile satellite systems. RF
exposure information and statement . this equipment complies with IC RSS-102
radiation exposure limits set forth for an uncontrolled environment. The
guidelines are based on standards that were developed by independent
scientific organizations through periodic and thorough evaluation of
scientific studies. The standards include a substantial safety margin designed
to assure the safety of all persons regardless of age or health. The SAR limit
of IC is 1.6W/Kg averaged. Device types: Has also been tested against this SAR
limit. This device was tested simulation typical 0 mm to body. To maintain
compliance with FCC RF exposure requirements, the use of belt clips, holsters
and similar accessories should not contain metallic components in its
assembly, the use of accessories that do not satisfy these requirements may
not comply with FCC RF exposure requirements, and should be avoided. The
highest reported SAR value for body conditions is 1.201W/Kg respectively.
References
- PASCO scientific | Science Lab Equipment and Teacher Resources
- Privacy Policies | PASCO
- PASCO Video Library - Resources | PASCO
- Privacy Policies | PASCO
- PASCO Video Library - Resources | PASCO
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>