AC INFINITY AirLift Series Shutter Exhaust Fan System User Manual
- June 4, 2024
- AC Infinity
Table of Contents
AC INFINITY AirLift Series Shutter Exhaust Fan System
Thank you for choosing AC Infinity. We are committed to product quality and friendly customer service. If you have any questions or suggestions, please don’t hesitate to contact us. Visit www.acinfinity.com and click contact for our contact information.
MANUAL CODE AL2005X1
PRODUCT
- AIRLIFT S10
- AIRLIFT S12
- AIRLIFT S14
- AIRLIFT S16
- AIRLIFT T10
- AIRLIFT T12
- AIRLIFT T14
- AIRLIFT T16
- AIRLIFT T18
- AIRLIFT T20
- AIRLIFT T22
- AIRLIFT T30
- AIRLIFT T36
MODEL
- AC-ALS10
- AC-ALS12
- AC-ALS14
- AC-ALS16
- AC-ALT10
- AC-ALT12
- AC-ALT14
- AC-ALT16
- AC-ALT18
- AC-ALT20
- AC-ALT22
- AC-ALT30
- AC-ALT36
UPC-A
- 819137021433
- 819137021440
- 819137021457
- 819137021464
- 819137020900
- 819137020917
- 819137020924
- 819137020948
- 819137020948
- 819137020955
- 819137020962
- 819137020986
- 819137020993
- MANUAL CODE AL2005X1
- SERIOUS
SERIOUS INJURY OR DEATH
Please do not touch the fan’s impeller and blades. Secure all nearby objects
including wires and cables from coming into contact with the fan’s impeller
and blades. Use caution when deciding where to install this fan.
KEY FEATURES
HEAVY DUTY BUILD
Fans are enclosed in steel and wire guards to withstand shocks and harsh
environments.
EFFICIENT EC-MOTOR
PWM-controlled EC-motor enables precise speed control, low noise, and higher
energy efficiency.
SMART CONTROLLER
A programmable controller with a corded sensor can adjust airflow in response
to temperature and humidity.
WEATHERPROOF
The shutter fan unit is sealed to Ingress Protection 44 standards to be
resistant to liquid and dust.
DUAL BALL BEARINGS
Long-life bearings are rated at 67,000 hours. Also allows the fan to be
mounted in any direction.
SPEED CONTROLLER
Single button controller with circular readout display that enables fan speed
control in eight speeds.
PRODUCT CONTENTS
AIRLIFT S-SERIES
AIRLIFT T-SERIES
FAN UNIT
MOUNTING
STEP 1
When installing in a large room like a greenhouse, barn, or garage, it is
recommended that the shutter fan should be mounted on the opposite side of any
ventilation openings for better air circulation. The fan should also be
positioned higher in the room to exhaust out heated air, which will rise on
its own due to natural convection.
STEP 2
Measure the dimensions of the shutter fan’s mounting frame which will go
through the wall. Select a location on the wall where you will be mounting the
fan. Please make sure that the wall is free of any wires or pipes. Using the
measurements of the shutter fan, use a level and ruler to draw an outline of
the area to be drilled and cut.
STEP 3
Depending on your mounting surface material, use the appropriate tools to cut
into the wall. Use a drill or a hand saw to create an opening large enough to
insert a saw blade or jigsaw inside the outlined area of the wall panel.
STEP 4
Position the shutter fan through the hole cut in step 3. Use it to measure the
positioning of the mounting screws then remove the fan unit. Then using a
drill bit, create the four mounting holes.
STEP 5
From inside the room, position the shutter fan back into the opening of the
fan. Make sure the controller connectors and power cord is on the inside of
the room. Then, use the included hardware to secure the fan.
If you are using your own shutter, remove the AIRLIFT’s shutter by unscrewing the nuts and bolts from the fan guard. Reassemble the fan guard onto your existing shutter by reapplying the nuts and bolts in the same mounting locations.
STEP 6
Once the fan is mounted securely you can then mount the controller using the
included hardware. Place the controller near the fan in order to power the
controller.
POWERING
STEP 1
Locate the connector plug of the sensor probe and plug it into the bottom of
the thermal controller.
STEP 2
Secure the sensor probe head nearby, preferably in the hottest area of the
room. You can use the wire tie to secure the probe away from the fan blades.
STEP 3
Connect the Molex end from the fan to the bottom of the controller.
STEP 4
Lastly, to power the fan and the controller, plug the fan’s power cord into an
AC power outlet.
DAISY CHAIN AND SETUP
The fan controller can power up to two compatible fans to share the same programming.
The controller included is compatible with AC Infinity fan models that contain an EC motor. Typically, EC-motor fans will have a separate cord coming out of it for the power and the controller. The compatible fans do not need to be the same model or part of the same product series.
PROGRAMMING
FAN SPEED ADJUSTING
The controller features a single button that controls the fan speed from 0-8.
Pressing the speed button increases the fan speed in one unit increments.
Pressing the button at the 8 settings will set the fan speed back to 0.
POWERING ON AND OFF
Holding the speed button for 4 seconds will turn the fan OFF. Pressing it
again from OFF will turn the fan ON at its last speed setting.
PROGRAMMING
-
MODE BUTTON
This button cycles through each of the controller’s modes: ON, OFF, TIMER, AUTO (4 triggers), and ALARM (4 settings). -
UP / DOWN BUTTON
The up and down buttons adjust the settings of the mode that you are in. Up button increases and the down button decreases. -
LEAF BUTTON
This turns the display off while programs run in the background. Hold for two seconds to lock or unlock the display. -
PROBE TEMP.
Displays the current temperature that the corded sensor probe is measuring. Shows “- -” if no probe is plugged in. -
CONTROLLER MODE
This area displays the mode that the controller is currently in. Press the Mode Button to cycle through the modes. -
ALERT ICONS
This area displays the alerts and statuses from the controller including alarms and screen lock. -
PROBE HUMIDITY
Displays the current humidity that the corded sensor probe is measuring. Shows “- -” if no probe is plugged in. -
FAN SPEED
Displays the current speed the fan is running at, or what speed it should be running at if no fans are plugged in. -
SETTING
Displays the value you have set for the current mode. Press the up or down button to change.
MODE SETTING
Press the Mode button to cycle through the controller’s available programming modes and settings: ON Mode, OFF Mode, TIMER Mode, AUTO Mode (4 triggers), ALARM Settings (4 settings).
ON MODE
In this mode, the fans will run continuously regardless of temperature or
humidity. The speed set in this mode will be the max speed the fans can reach
in AUTO Mode.
OFF MODE
In this mode, the fans will not run regardless of temperature or humidity.
While in this mode, pressing the up or down button will change the display’s
brightness. There are four settings for brightness, (Setting:1/2/3/A3). On
setting A3, if the device is left unattended for 30 seconds, the display will
automatically dim its brightness back to setting 1. Holding the up or down
button will change the display’s units F or C.
TIMER MODE
In this mode, press the up or down button to set a time for the timer. The
fans will run at the speed set in ON Mode until the timer’s clock runs out, in
which the fans will stop running. The clock will begin counting down if no
buttons are pressed for 3 seconds. Leaving the timer mode while the countdown
is running will pause the clock until you return to this mode.
AUTO MODE: HIGH TEMP.
In this mode, press the up or down button to set a high-temperature trigger.
The fans will activate if the probe’s measured temperature exceeds the
temperature you have set in this mode. The activated fans will slowly increase
in speed until it reaches the speed set in ON Mode. Whenever the measured
temperature falls below your set temperature, the fans will slowly decrease in
speed until the fans stop. You may also hold the up and down button
simultaneously to turn off this trigger, in which the digits under settings
will show OFF.
Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode.
AUTO MODE: LOW TEMP.
In this mode, press the up or down button to set a low-temperature trigger.
The fans will activate if the probe’s measured temperature falls below the
temperature you have set in this mode. The activated fans will slowly increase
in speed until it reaches the speed set in ON Mode. Whenever the measured
temperature rises above your set temperature, the fans will slowly decrease in
speed until fans stop. You may also hold the up and down button simultaneously
to turn off this trigger, in which the digits under settings will show OFF
.
Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode.
AUTO MODE: HIGH HUMID.
In this mode, press the up or down button to set a high humidity trigger. The
fans will activate if the probe’s measured humidity exceeds the humidity you
have set in this mode. The activated fans will slowly increase in speed until
it reaches the speed set in ON Mode. Whenever the measured humidity falls
below your set humidity, the fans will slowly decrease in speed until fans
stop. You may also hold the up and down button simultaneously to turn off this
trigger, in which the digits under settings will show OFF.
Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode.
AUTO MODE: LOW HUMID.
In this mode, press the up or down button to set a low humidity trigger. The
fans will activate if the probe’s measured humidity falls below the humidity
you have set in this mode. The activated fans will slowly increase in speed
until it reaches the speed set in ON Mode. Whenever the measured humidity
rises above your set temperature, the fans will slowly decrease in speed until
the fans stop. You may also hold the up and down button simultaneously to turn
off this trigger, in which the digits under settings will show OFF.
Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode.
ALARM SETTING: HIGH TEMP.
In this settings mode, press the up and down button to set a high-temperature
alarm. The alarm will activate if the probe’s measured temperature exceeds the
temperature you have set in this mode. When the alarm triggers, the fan will
start spinning at max speed regardless of your other settings. You may also
hold the up and down button simultaneously to turn off this alarm, in which
the digits under settings will show OFF. You will need to be in AUTO, ON, or
TIMER mode for this alarm to be able to activate.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.
ALARM SETTING: LOW TEMP.
In this settings mode, press the up and down button to set a low-temperature
alarm. The alarm will activate if the probe’s measured temperature falls below
the temperature you have set in this mode. When the alarm triggers, the fan
will start spinning at max speed regardless of your other settings. You may
also hold the up and down button simultaneously to turn off this alarm, in
which the digits under settings will show OFF. You will need to be in AUTO,
ON, or TIMER mode for this alarm to be able to activate.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.
ALARM SETTING: HIGH HUMID.
In this settings mode, press the up and down button to set a high humidity
alarm. The alarm will activate if the probe’s measured humidity exceeds the
humidity you have set in this mode. When the alarm triggers, the fan will
start spinning at max speed regardless of your other settings. You may also
hold the up and down button simultaneously to turn off this alarm, in which
the digits under settings will show OFF. You will need to be in AUTO, ON, or
TIMER mode for this alarm to be able to activate.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.
ALARM SETTING: LOW HUMID.
In this settings mode, press the up and down button to set a low humidity
alarm. The alarm will activate if the probe’s measured humidity falls below
the temperature you have set in this mode. When the alarm triggers, the fan
will start spinning at max speed regardless of your other settings. You may
also hold the up and down button simultaneously to turn off this alarm, in
which the digits under settings will show OFF. You will need to be in AUTO,
ON, or TIMER mode for this alarm to be able to activate.
Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.
FAHRENHEIT OR CELSIUS
To change to displayed units between Fahrenheit and Celsius, please set the
controller to OFF Mode, then hold the up button for Fahrenheit (°F) or hold
the down button for Celsius (°C).
DISPLAY BRIGHTNESS
To adjust the brightness of the display, please set the controller to OFF
Mode, then press the up or down button to increase or decrease the brightness
level. Four brightness settings are available.
TEMPERATURE CALIBRATION
To adjust the temperature that the probe sensor is measuring, please press the
MODE and UP buttons simultaneously. This can be done while the controller is
any mode or setting. The calibration cycle ranges from -8°F to 8°F (or -4°C to
4°C) and will be applied to the probe sensor’s measurements.
HUMIDITY CALIBRATION
To adjust the humidity that the probe sensor is measuring, please press the
MODE and DOWN buttons simultaneously. This can be done while the controller is
any mode or setting. The calibration cycle ranges from -8% to 8% and will be
applied to the probe sensor’s measurements.
CONTROLLER LOCK
To lock the controller to prevent settings to be changed accidentally, hold
the LEAF button for two or more seconds. While the display is locked, you will
not be able to switch modes or change any settings. You will only be able to
put the controller in the ECO display by pressing the LEAF button. Holding the
LEAF button for two or more seconds will unlock the controller.
ECO-MODE
The controller can be put into an ECO display in which the screen will be
turned off but all programs, settings, and alarms will be running in the
background. This can be done by pressing the LEAF button. You may also do this
while the controller is locked. To exit the ECO display, simply press any
buttons.
ALERT ICONS
On the top left of the display is the alert icon section. Icons may flash when
the controller wishes to alert you that a particular function or alarm is
being triggered.
DISPLAY LOCK ALERT
This icon is visible when the controller has been locked. The icon will flash
to alert you that the controller is locked if you try to change the mode or
settings.
HUMIDITY ALARM ALERT
This icon will flash when the high or low humidity alarm that you have set has
been triggered.
TEMPERATURE ALARM ALERT
This icon will flash when the high or low-temperature alarm that you have set
has been triggered.
CHECK FAN ALERT
This icon will flash when the fan’s sensor detects interference to its
operation. Please check the fan for possible issues. If the fan is rotating,
it may be static pressure resistance and operating as intended. If the fan is
not rotating, please see the warranty page for replacement information. (This
is only available on certain models.).
AC INFINITY PRODUCTS
Register Booster Fans
The AIR TAP series is a line of register booster fans designed to quietly
increase airflow coming from your central heat and air conditioning systems,
increasing comfort for your home. Features a thermal controller with
intelligent programming that will automatically adjust airflow strength in
response to heating and cooling temperatures you have set.
Duct Fans
The CLOUDLINE series is a line of duct fans designed to quietly ventilate AV
rooms and closets, as well as various DIY air circulation and exhaust
projects. Features a thermal controller with intelligent programming that will
automatically adjust duct fan speeds in response to changing temperatures.
Crawlspace Fans
The AIRTITAN is a line of weather-proof fans designed to provide ventilation,
odor, and moisture control for crawl spaces and basements. It features a
digital controller with intelligent programming that will adjust airflow
strength in response to high and low temperatures, as well as humidity.
WARRANTY
This warranty program is our commitment to you, the product sold by AC Infinity will be free from defects in the manufacturing for a period of two years from the date of purchase. If a product is found to have a defect in material or workmanship, we will take the appropriate actions defined in this warranty to resolve any issues.
The warranty program applies to any order, purchase, receipt, or use of any products sold by AC Infinity or our authorized dealerships. The program covers products that have become defective, malfunctioned, or expressively if the product becomes unusable. The warranty program goes into effect on the date of purchase. The program will expire two years from the date of purchase. If your product becomes defective during that period, AC Infinity will replace your product with a new one or issue you a full refund.
The warranty program does not cover abuse or misuse. This includes physical damage, submersion of the product in water, incorrect Installation such as wrong voltage input, and misuse for any reason other than intended purposes. AC Infinity is not responsible for consequential loss or incidental damages of any nature caused by the product. We will not warrant damage from normal wear such as scratches and dings.
To initiate a product warranty claim, please contact our customer service team at support@acinfinity.com.
If you are not 100% satisfied with this product, we will be happy to replace it or issue you a full refund. Please contact us!
COPYRIGHT © 2020 AC INFINITY INC. ALL RIGHTS RESERVED
No part of the materials including graphics or logos available in this booklet
may be copied, photocopied, reproduced, translated, or reduced to any
electronic medium or machine-readable form, in whole or in part, without
specific permission from AC Infinity Inc.
www.acinfinity.com.
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>