AC INFINITY AirLift Series Shutter Exhaust Fan System User Manual

June 4, 2024
AC Infinity

AC-INFINITY-logo

AC INFINITY AirLift Series Shutter Exhaust Fan System

Thank you for choosing AC Infinity. We are committed to product quality and friendly customer service. If you have any questions or suggestions, please don’t hesitate to contact us. Visit www.acinfinity.com and click contact for our contact information.

MANUAL CODE AL2005X1

PRODUCT

  • AIRLIFT S10
  • AIRLIFT S12
  • AIRLIFT S14
  • AIRLIFT S16
  • AIRLIFT T10
  • AIRLIFT T12
  • AIRLIFT T14
  • AIRLIFT T16
  • AIRLIFT T18
  • AIRLIFT T20
  • AIRLIFT T22
  • AIRLIFT T30
  • AIRLIFT T36

MODEL

  • AC-ALS10
  • AC-ALS12
  • AC-ALS14
  • AC-ALS16
  • AC-ALT10
  • AC-ALT12
  • AC-ALT14
  • AC-ALT16
  • AC-ALT18
  • AC-ALT20
  • AC-ALT22
  • AC-ALT30
  • AC-ALT36

UPC-A

  • 819137021433
  • 819137021440
  • 819137021457
  • 819137021464
  • 819137020900
  • 819137020917
  • 819137020924
  • 819137020948
  • 819137020948
  • 819137020955
  • 819137020962
  • 819137020986
  • 819137020993
  • MANUAL CODE AL2005X1
  • SERIOUS

SERIOUS INJURY OR DEATH
Please do not touch the fan’s impeller and blades. Secure all nearby objects including wires and cables from coming into contact with the fan’s impeller and blades. Use caution when deciding where to install this fan.

KEY FEATURES

HEAVY DUTY BUILD
Fans are enclosed in steel and wire guards to withstand shocks and harsh environments.

EFFICIENT EC-MOTOR
PWM-controlled EC-motor enables precise speed control, low noise, and higher energy efficiency.

SMART CONTROLLER
A programmable controller with a corded sensor can adjust airflow in response to temperature and humidity.AC-INFINITY-AirLift-Series-Shutter-Exhaust-Fan-
System-fig-1

WEATHERPROOF
The shutter fan unit is sealed to Ingress Protection 44 standards to be resistant to liquid and dust.

DUAL BALL BEARINGS
Long-life bearings are rated at 67,000 hours. Also allows the fan to be mounted in any direction.

SPEED CONTROLLER
Single button controller with circular readout display that enables fan speed control in eight speeds.

PRODUCT CONTENTS

AIRLIFT S-SERIESAC-INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-
fig-2

AIRLIFT T-SERIESAC-INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-
fig-3

FAN UNITAC-INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-
fig-4

MOUNTING

STEP 1
When installing in a large room like a greenhouse, barn, or garage, it is recommended that the shutter fan should be mounted on the opposite side of any ventilation openings for better air circulation. The fan should also be positioned higher in the room to exhaust out heated air, which will rise on its own due to natural convection.AC-INFINITY-AirLift-Series-Shutter-
Exhaust-Fan-System-fig-5

STEP 2
Measure the dimensions of the shutter fan’s mounting frame which will go through the wall. Select a location on the wall where you will be mounting the fan. Please make sure that the wall is free of any wires or pipes. Using the measurements of the shutter fan, use a level and ruler to draw an outline of the area to be drilled and cut.AC-INFINITY-AirLift-Series-Shutter-Exhaust-
Fan-System-fig-6

STEP 3
Depending on your mounting surface material, use the appropriate tools to cut into the wall. Use a drill or a hand saw to create an opening large enough to insert a saw blade or jigsaw inside the outlined area of the wall panel.AC-
INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-fig-7

STEP 4
Position the shutter fan through the hole cut in step 3. Use it to measure the positioning of the mounting screws then remove the fan unit. Then using a drill bit, create the four mounting holes.

STEP 5
From inside the room, position the shutter fan back into the opening of the fan. Make sure the controller connectors and power cord is on the inside of the room. Then, use the included hardware to secure the fan.

If you are using your own shutter, remove the AIRLIFT’s shutter by unscrewing the nuts and bolts from the fan guard. Reassemble the fan guard onto your existing shutter by reapplying the nuts and bolts in the same mounting locations.AC-INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-
fig-9

STEP 6
Once the fan is mounted securely you can then mount the controller using the included hardware. Place the controller near the fan in order to power the controller.AC-INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-
fig-10

POWERING

STEP 1
Locate the connector plug of the sensor probe and plug it into the bottom of the thermal controller.

STEP 2
Secure the sensor probe head nearby, preferably in the hottest area of the room. You can use the wire tie to secure the probe away from the fan blades.

STEP 3
Connect the Molex end from the fan to the bottom of the controller. AC-
INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-
fig-13

STEP 4
Lastly, to power the fan and the controller, plug the fan’s power cord into an AC power outlet.AC-INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-
fig-14

DAISY CHAIN AND SETUP

The fan controller can power up to two compatible fans to share the same programming.AC-INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-
fig-15

The controller included is compatible with AC Infinity fan models that contain an EC motor. Typically, EC-motor fans will have a separate cord coming out of it for the power and the controller. The compatible fans do not need to be the same model or part of the same product series. AC-INFINITY-AirLift-Series-
Shutter-Exhaust-Fan-System-fig-16

PROGRAMMING

FAN SPEED ADJUSTING
The controller features a single button that controls the fan speed from 0-8. Pressing the speed button increases the fan speed in one unit increments. Pressing the button at the 8 settings will set the fan speed back to 0.AC-
INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-
fig-17

POWERING ON AND OFF
Holding the speed button for 4 seconds will turn the fan OFF. Pressing it again from OFF will turn the fan ON at its last speed setting.

PROGRAMMING

  1. MODE BUTTON
    This button cycles through each of the controller’s modes: ON, OFF, TIMER, AUTO (4 triggers), and ALARM (4 settings).

  2. UP / DOWN BUTTON
    The up and down buttons adjust the settings of the mode that you are in. Up button increases and the down button decreases.

  3. LEAF BUTTON
    This turns the display off while programs run in the background. Hold for two seconds to lock or unlock the display.AC-INFINITY-AirLift-Series-Shutter-
Exhaust-Fan-System-fig-19

  4. PROBE TEMP.
    Displays the current temperature that the corded sensor probe is measuring. Shows “- -” if no probe is plugged in.

  5. CONTROLLER MODE
    This area displays the mode that the controller is currently in. Press the Mode Button to cycle through the modes.

  6. ALERT ICONS
    This area displays the alerts and statuses from the controller including alarms and screen lock.

  7. PROBE HUMIDITY
    Displays the current humidity that the corded sensor probe is measuring. Shows “- -” if no probe is plugged in.

  8. FAN SPEED
    Displays the current speed the fan is running at, or what speed it should be running at if no fans are plugged in.

  9. SETTING
    Displays the value you have set for the current mode. Press the up or down button to change.

MODE SETTING

Press the Mode button to cycle through the controller’s available programming modes and settings: ON Mode, OFF Mode, TIMER Mode, AUTO Mode (4 triggers), ALARM Settings (4 settings).

ON MODE
In this mode, the fans will run continuously regardless of temperature or humidity. The speed set in this mode will be the max speed the fans can reach in AUTO Mode.AC-INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-
fig-20

OFF MODE
In this mode, the fans will not run regardless of temperature or humidity. While in this mode, pressing the up or down button will change the display’s brightness. There are four settings for brightness, (Setting:1/2/3/A3). On setting A3, if the device is left unattended for 30 seconds, the display will automatically dim its brightness back to setting 1. Holding the up or down button will change the display’s units F or C.AC-INFINITY-AirLift-Series-
Shutter-Exhaust-Fan-System-fig-21

TIMER MODE
In this mode, press the up or down button to set a time for the timer. The fans will run at the speed set in ON Mode until the timer’s clock runs out, in which the fans will stop running. The clock will begin counting down if no buttons are pressed for 3 seconds. Leaving the timer mode while the countdown is running will pause the clock until you return to this mode.AC-INFINITY-
AirLift-Series-Shutter-Exhaust-Fan-System-fig-22

AUTO MODE: HIGH TEMP.
In this mode, press the up or down button to set a high-temperature trigger. The fans will activate if the probe’s measured temperature exceeds the temperature you have set in this mode. The activated fans will slowly increase in speed until it reaches the speed set in ON Mode. Whenever the measured temperature falls below your set temperature, the fans will slowly decrease in speed until the fans stop. You may also hold the up and down button simultaneously to turn off this trigger, in which the digits under settings will show OFF.AC-INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-
fig-23

Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode.

AUTO MODE: LOW TEMP.
In this mode, press the up or down button to set a low-temperature trigger. The fans will activate if the probe’s measured temperature falls below the temperature you have set in this mode. The activated fans will slowly increase in speed until it reaches the speed set in ON Mode. Whenever the measured temperature rises above your set temperature, the fans will slowly decrease in speed until fans stop. You may also hold the up and down button simultaneously to turn off this trigger, in which the digits under settings will show OFF .AC-INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-
fig-24

Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode.

AUTO MODE: HIGH HUMID.
In this mode, press the up or down button to set a high humidity trigger. The fans will activate if the probe’s measured humidity exceeds the humidity you have set in this mode. The activated fans will slowly increase in speed until it reaches the speed set in ON Mode. Whenever the measured humidity falls below your set humidity, the fans will slowly decrease in speed until fans stop. You may also hold the up and down button simultaneously to turn off this trigger, in which the digits under settings will show OFF.AC-INFINITY-
AirLift-Series-Shutter-Exhaust-Fan-System-fig-25

Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode.

AUTO MODE: LOW HUMID.
In this mode, press the up or down button to set a low humidity trigger. The fans will activate if the probe’s measured humidity falls below the humidity you have set in this mode. The activated fans will slowly increase in speed until it reaches the speed set in ON Mode. Whenever the measured humidity rises above your set temperature, the fans will slowly decrease in speed until the fans stop. You may also hold the up and down button simultaneously to turn off this trigger, in which the digits under settings will show OFF.AC-
INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-
fig-26

Note that this trigger can activate as long as you are in AUTO Mode, even if you are viewing a different trigger within AUTO Mode.

ALARM SETTING: HIGH TEMP.
In this settings mode, press the up and down button to set a high-temperature alarm. The alarm will activate if the probe’s measured temperature exceeds the temperature you have set in this mode. When the alarm triggers, the fan will start spinning at max speed regardless of your other settings. You may also hold the up and down button simultaneously to turn off this alarm, in which the digits under settings will show OFF. You will need to be in AUTO, ON, or TIMER mode for this alarm to be able to activate.AC-INFINITY-AirLift-Series-
Shutter-Exhaust-Fan-System-fig-27

Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.

ALARM SETTING: LOW TEMP.
In this settings mode, press the up and down button to set a low-temperature alarm. The alarm will activate if the probe’s measured temperature falls below the temperature you have set in this mode. When the alarm triggers, the fan will start spinning at max speed regardless of your other settings. You may also hold the up and down button simultaneously to turn off this alarm, in which the digits under settings will show OFF. You will need to be in AUTO, ON, or TIMER mode for this alarm to be able to activate.AC-INFINITY-AirLift-
Series-Shutter-Exhaust-Fan-System-fig-28

Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.

ALARM SETTING: HIGH HUMID.
In this settings mode, press the up and down button to set a high humidity alarm. The alarm will activate if the probe’s measured humidity exceeds the humidity you have set in this mode. When the alarm triggers, the fan will start spinning at max speed regardless of your other settings. You may also hold the up and down button simultaneously to turn off this alarm, in which the digits under settings will show OFF. You will need to be in AUTO, ON, or TIMER mode for this alarm to be able to activate.AC-INFINITY-AirLift-Series-
Shutter-Exhaust-Fan-System-fig-29

Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.

ALARM SETTING: LOW HUMID.
In this settings mode, press the up and down button to set a low humidity alarm. The alarm will activate if the probe’s measured humidity falls below the temperature you have set in this mode. When the alarm triggers, the fan will start spinning at max speed regardless of your other settings. You may also hold the up and down button simultaneously to turn off this alarm, in which the digits under settings will show OFF. You will need to be in AUTO, ON, or TIMER mode for this alarm to be able to activate.AC-INFINITY-AirLift-
Series-Shutter-Exhaust-Fan-System-fig-30

Note that alarm triggers can only activate in AUTO, ON, or TIMER Mode. Please leave ALARM SETTING to arm the controller.

FAHRENHEIT OR CELSIUS
To change to displayed units between Fahrenheit and Celsius, please set the controller to OFF Mode, then hold the up button for Fahrenheit (°F) or hold the down button for Celsius (°C).

DISPLAY BRIGHTNESS
To adjust the brightness of the display, please set the controller to OFF Mode, then press the up or down button to increase or decrease the brightness level. Four brightness settings are available.

TEMPERATURE CALIBRATION
To adjust the temperature that the probe sensor is measuring, please press the MODE and UP buttons simultaneously. This can be done while the controller is any mode or setting. The calibration cycle ranges from -8°F to 8°F (or -4°C to 4°C) and will be applied to the probe sensor’s measurements.

HUMIDITY CALIBRATION
To adjust the humidity that the probe sensor is measuring, please press the MODE and DOWN buttons simultaneously. This can be done while the controller is any mode or setting. The calibration cycle ranges from -8% to 8% and will be applied to the probe sensor’s measurements.

CONTROLLER LOCK
To lock the controller to prevent settings to be changed accidentally, hold the LEAF button for two or more seconds. While the display is locked, you will not be able to switch modes or change any settings. You will only be able to put the controller in the ECO display by pressing the LEAF button. Holding the LEAF button for two or more seconds will unlock the controller.

ECO-MODE
The controller can be put into an ECO display in which the screen will be turned off but all programs, settings, and alarms will be running in the background. This can be done by pressing the LEAF button. You may also do this while the controller is locked. To exit the ECO display, simply press any buttons.

ALERT ICONS
On the top left of the display is the alert icon section. Icons may flash when the controller wishes to alert you that a particular function or alarm is being triggered.AC-INFINITY-AirLift-Series-Shutter-Exhaust-Fan-System-
fig-31

DISPLAY LOCK ALERT
This icon is visible when the controller has been locked. The icon will flash to alert you that the controller is locked if you try to change the mode or settings.

HUMIDITY ALARM ALERT
This icon will flash when the high or low humidity alarm that you have set has been triggered.

TEMPERATURE ALARM ALERT
This icon will flash when the high or low-temperature alarm that you have set has been triggered.

CHECK FAN ALERT
This icon will flash when the fan’s sensor detects interference to its operation. Please check the fan for possible issues. If the fan is rotating, it may be static pressure resistance and operating as intended. If the fan is not rotating, please see the warranty page for replacement information. (This is only available on certain models.).

AC INFINITY PRODUCTS

Register Booster Fans
The AIR TAP series is a line of register booster fans designed to quietly increase airflow coming from your central heat and air conditioning systems, increasing comfort for your home. Features a thermal controller with intelligent programming that will automatically adjust airflow strength in response to heating and cooling temperatures you have set.

Duct Fans
The CLOUDLINE series is a line of duct fans designed to quietly ventilate AV rooms and closets, as well as various DIY air circulation and exhaust projects. Features a thermal controller with intelligent programming that will automatically adjust duct fan speeds in response to changing temperatures.

Crawlspace Fans
The AIRTITAN is a line of weather-proof fans designed to provide ventilation, odor, and moisture control for crawl spaces and basements. It features a digital controller with intelligent programming that will adjust airflow strength in response to high and low temperatures, as well as humidity.

WARRANTY

This warranty program is our commitment to you, the product sold by AC Infinity will be free from defects in the manufacturing for a period of two years from the date of purchase. If a product is found to have a defect in material or workmanship, we will take the appropriate actions defined in this warranty to resolve any issues.

The warranty program applies to any order, purchase, receipt, or use of any products sold by AC Infinity or our authorized dealerships. The program covers products that have become defective, malfunctioned, or expressively if the product becomes unusable. The warranty program goes into effect on the date of purchase. The program will expire two years from the date of purchase. If your product becomes defective during that period, AC Infinity will replace your product with a new one or issue you a full refund.

The warranty program does not cover abuse or misuse. This includes physical damage, submersion of the product in water, incorrect Installation such as wrong voltage input, and misuse for any reason other than intended purposes. AC Infinity is not responsible for consequential loss or incidental damages of any nature caused by the product. We will not warrant damage from normal wear such as scratches and dings.

To initiate a product warranty claim, please contact our customer service team at [email protected].

If you are not 100% satisfied with this product, we will be happy to replace it or issue you a full refund. Please contact us!

COPYRIGHT © 2020 AC INFINITY INC. ALL RIGHTS RESERVED
No part of the materials including graphics or logos available in this booklet may be copied, photocopied, reproduced, translated, or reduced to any electronic medium or machine-readable form, in whole or in part, without specific permission from AC Infinity Inc. www.acinfinity.com.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AC Infinity User Manuals

Related Manuals