TOWN COUNTRY TCWS54 Outdoor Gas Fireplace Instruction Manual

June 12, 2024
TOWN COUNTRY

TCWS54 Outdoor Gas Fireplace

Product Information:

The product is an outdoor gas fireplace with the model number
TCWS.54OD Series C. It features a screen for safety and is designed
for outdoor use only. The appliance is manufactured by Town &
Country Fireplaces.

The fireplace can produce carbon monoxide, which is an odorless
gas that can be harmful to health. Therefore, it should never be
used in enclosed spaces such as campers, tents, cars, or homes.

The appliance comes with a warning regarding hot glass, which
can cause burns. It is important not to touch the glass until it
has cooled down. Children should also be prevented from touching
the glass to avoid accidents.

There is a caution regarding the use of the fireplace without
reading and understanding the manual. Any deviation from the
provided instructions may void the warranty and pose hazards.

During pressure testing of the gas supply piping system, the
appliance and its individual shut-off valve must be disconnected if
the test pressures exceed 1/2 psig (3.5 kPa). If the test pressures
are equal to or less than 1/2 psig (3.5 kPa), the appliance must be
isolated from the gas supply piping system by closing its
individual manual shut-off valve.

When the fireplace is lit for the first time, there may be a
slight odor for a few hours. This is normal and temporary, caused
by the curing of paints, sealants, and lubricants used in the
manufacturing process. Ventilation by opening doors and windows is
recommended to dissipate any smoke or fumes that may cause
discomfort to some individuals.

Product Usage Instructions:

  1. Gas Smell: If you smell gas:

  2. Shut off gas to the appliance.

  3. Extinguish any open flame.

  4. If the odor continues, keep away from the appliance and
    immediately call your gas supplier or fire department.

  5. Storage of Flammable Vapors and Liquids: Do
    not store or use gasoline or other flammable vapors and liquids
    near the appliance or any other appliance. An LP-cylinder not
    connected for use should not be stored.

  6. Installation and Service: Installation and
    service must be performed by a qualified installer, service agency,
    or the gas supplier.

  7. Venting: Refer to the Venting section in the
    manual for instructions on proper venting. A Roof Termination
    Venting Chart is provided for reference.

  8. Hot Glass: The glass of the fireplace can
    cause burns. Do not touch the glass until it has cooled down.
    Ensure that children do not touch the glass to prevent
    accidents.

  9. Chemical Exposure: The product may expose you
    to chemicals including ceramic fibers and carbon monoxide, which
    are known to the State of California to cause cancer, birth
    defects, or other reproductive harm. For more information, visit
    www.P65Warnings.ca.gov.

  10. Safety Precautions: Read and understand the
    manual before installing or operating the fireplace. Any deviation
    from the provided instructions may void the warranty and pose
    hazards.

  11. Pressure Testing: During pressure testing of
    the gas supply piping system:

  12. If the test pressures exceed 1/2 psig (3.5 kPa), disconnect the
    appliance and its individual shut-off valve.

  13. If the test pressures are equal to or less than 1/2 psig (3.5
    kPa), isolate the appliance from the gas supply piping system by
    closing its individual manual shut-off valve.

  14. Initial Use: When lighting the fireplace for
    the first time, there may be a slight odor for a few hours. This is
    normal and temporary due to the curing process of paints, sealants,
    and lubricants used in manufacturing. Ventilate the area by opening
    doors and windows to dissipate any smoke or fumes that may cause
    discomfort to some individuals.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference.

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

DANGER: If you smell gas:
1. Shut off gas to the appliance 2. Extinguish any open flame. 3. If odor continues, keep away from the
appliance and immediately call your gas supplier or fire department.
WARNING: Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. An LP-cylinder not connected for use shall not be stored

SERIAL #
TCWS54 OUTDOOR GAS FIREPLACE INSTALLATION AND OPERATING INSTRUCTIONS

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment.

MODEL: TCWS.54OD SERIES C w/ screen

CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor. Using it in an enclosed space can kill you. Never use this appliance in an enclosed space such as a camper, tent, car or home.

WARNING: For Outdoor Use Only

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

Visit www.townandcountryfireplaces.net for the most recent version of this manual

1T8C1W12S1-.5240OD W SCREEN_181121-20

TCWS.54 OD W SCREEN

100005095

Table of Contents

Table of Contents ……………………………………………………………. 2 Caution ………………………………………………………………………….. 3 Safety ……………………………………………………………………………. 3 Important Note for the Commonwealth of Massachusetts ……. 4 This Fireplace Is Intended For Outdoor Use Only! ……………….. 5 Propane Conversion ………………………………………………………… 6 Fireplace Dimensions ………………………………………………………. 7 Minimum Clearances to Combustible Material ……………………. 7
Mantel Clearance Chart …………………………………………….. 7 Installation Requirements …………………………………………………. 8 Window Frame Removal ………………………………………………….. 8 Standoffs ……………………………………………………………………….. 9 Locating The Fireplace …………………………………………………….. 9 Framing and Finishing ……………………………………………………. 10
Steel Stud Framing Kit Dimensions …………………………… 10 Minimum Combustible ……………………………………………. 11 Framing Dimensions ……………………………………………….. 11 Non- Combustible Board Detail …………………………………. 11 Non-Combustible Recessed Installation Detail …………… 11 Steel Stud Framing Kit …………………………………………………… 12 Frame assembly……………………………………………………… 13 Screen Installation …………………………………………………………. 15 Honeywell Control Valve Plumbing and Electrical ………………. 16 Installation ……………………………………………………………… 16 Gas Supply …………………………………………………………………… 17 Gas Pressure Check ………………………………………………………. 17 Correct gas pressure requirement……………………………… 17

Venting …………………………………………………………………………. 18 Roof Termination Venting Chart ……………………………………….. 18
Ceiling Opening………………………………………………………. 19 Ceiling Firestop ………………………………………………………. 19 Vent Pipe ……………………………………………………………….. 19 Roof Support Bracket ……………………………………………… 19 Roof Vent Terminal ………………………………………………….. 20 Vent Terminal Clearance …………………………………………………. 21 Vent Pipe Sealant ………………………………………………………….. 22 Vent Restrictor Adjustment …………………………………………….. 23 Firebox Panels Installation ……………………………………………… 24 Lighting Instructions ………………………………………………………. 25 First Fire ……………………………………………………………………….. 25 Maintenance …………………………………………………………………. 26 Glass Panel: …………………………………………………………… 26 Annual Inspection:…………………………………………………… 26 Periodically:……………………………………………………………. 26 TCWS.54CODE Replacement Parts …………………………………. 27 Honeywell Control System Replacement Parts …………………. 28 Wiring Diagram ……………………………………………………………… 29 Roof Termination Kit ………………………………………………………. 30 Vent Pipe Dimensions ……………………………………………………. 31 Vent Offset Chart …………………………………………………………… 32 Quick Panel Removal for Valve Service ……………………………. 33 Rating Label Location ……………………………………………………. 34

! DANGER
HOT GLASS WILL CAUSE BURNS.
DO NOT TOUCH GLASS UNTIL COOLED.
NEVER ALLOW CHILDREN TO TOUCH GLASS.

WARNING: This product can expose you to chemicals including ceramic fibers, which are known to the State of California to cause cancer, and carbon monoxide, which is known to the State of California to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov.
This warning is applicable to all Pacific Energy Fireplace Products

100005095

2

TCWS.54OD W SCREEN_181121-20

Caution

FOR YOUR SAFETY – Do not install or operate your Town & Country fireplace without first reading and understanding this manual. Any installation or operational deviation from the following instructions voids the Town & Country Fireplaces Warranty and may prove hazardous.
This appliance and its individual shut off valve must be disconnected from gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPa).
This appliance must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
Note: When lit for the first time, the appliance will emit a slight odour for a couple of hours. This is due to the curing of paints, sealants and lubricants used in the manufacturing process. This condition is temporary. Open doors and windows to ventilate area. Smoke and fumes caused by the curing process may cause discomfort to some individuals.
Do not use the fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.
Safety

We recommend that our gas hearth products be installed and serviced by professionals who are certified in the United States by the National Fireplace Institute® (NFI) as NFI Gas Specialists

Due to high temperatures, this gas appliance should be located out of traffic and away from furniture and draperies.
Children and adults should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance.
Clothing or other flammable material should not be placed on or near the appliance.
Any grill, panel or door removed for servicing the unit must be replaced prior to operating. Failure to do so may create a hazardous condition.
Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. It is imperative that control compartments, burners and circulating air passageways of the appliance be kept clean.
It is our policy that no responsibility is assumed by the Company or by any of its employees or representatives for any damages caused by an inoperable, inadequate, or unsafe condition which is the result, either directly or indirectly, of any improper operation or installation procedures.
This appliance must not be connected to a chimney flue serving a separate solid fuel burning appliance.

TCWS.54OD W SCREEN_181121-20

3

100005095

Important Note for the Commonwealth of Massachusetts
From Massachusetts Rules and Regulations 248 CMR 5.08:
(a) For all side wall horizontally vented gas fuelled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied.
1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fuelled equipment, the installing plumber or gas fitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed, in addition, the installing plumber or gas fitter shall observe that a battery operated or hard-wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fuelled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard- wired carbon monoxide detectors.
a. In the event that the side wall horizontally vented gas fuelled equipment is installed in a crawl space or an attic, the hard-wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.
b. In the event that the requirements of this subdivision cannot be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed.
2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed as IAS certified.
3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fuelled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”.
4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fuelled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.089(2)(a) 1 through 4.
(b) EXEMPTIONS. The following equipment is exempt from 248 CMR 5.089(2)(a) 1 through 4. 1. The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and 2. Product Approved side wall horizontal vented gas fuelled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.
(c) MANUFACTURER REQUIREMENTS ­ GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include: 1. Detailed instructions for the installation of the venting system design or the venting system components; and 2. A complete parts list for the venting system design or venting system.
(d) MANUFACTURER REQUIREMENTS ­ GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fuelled equipment does not provide the parts for venting the fuel gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer. 1. The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and 2. The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions.
(e)) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fuelled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation.

100005095

4

TCWS.54OD W SCREEN_181121-20

This Fireplace Is Intended For Outdoor Use Only!

WARNING: Solid fuels should not be burned in this appliance.

Warning: This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

· The fireplace must be located inside of a weatherproof enclosure.
· Flashing must be installed around the fireplace opening in accordance with local building codes in order to prevent moisture from entering the enclosure.
· A drip pan (not supplied with the unit) must be installed under the fireplace and be provided with a means of draining.
· Care must be taken to select materials and building practices which will protect the enclosure and fireplace from exposure to moisture.
· Not for use with a power vent.

TCWS.54OD W SCREEN_181121-20

5

100005095

Propane Conversion

THIS FIREPLACE IS DESIGNED FOR USE WITH A HONEYWELL PILOT, DO NOT USE ANY OTHER PILOT WITH YOUR OUTDOOR FIREPLACE.
1. Remove the compression fitting from the bottom of the orifice housing and gently tap the pilot in your hand. The natural gas orifice should fall out (Figure 1).

2. Insert the propane orifice that came in your instruction pack as shown into the orifice housing and reattach the pilot to the compression fitting and pilot tube (Figure 2) & (Figure 3).

3. Using the valve conversion kit that came in the instruction pack, convert the valve to propane following the instructions provided with the kit (Figure 4).

Figure 2: Orifice insert.

ORIFICE HOUSING ORIFICE
COMPRESSION FITTING
ORIFICE

Figure 3: ORIFICE.

ORIFICE HOUSING

Figure 1: PILOT. COMPRESSION
FITTING

Figure 4: Valve conversion kit.

100005095

6

TCWS.54OD W SCREEN_181121-20

Fireplace Dimensions

74 3/4″

74 3/4″

36 7/8″

37 7/8″

13 5/8″ 53 7/8″

25 3/4″ 28 5/8″

55″ 18″

29 3/4″

Figure 5: TCWS.54 OD with Screen dimensions.

Minimum Clearances to Combustible Material

COMBUSTIBLE FRAMING AND FINISH WALL ABOVE STANDOFFS

MAY USE COMBUSTIBLE FACING MATERIAL IN THIS AREA

NON-COMBUSTIBLE FINISH MATERIAL SEE FIG #8 & 9

D E

A

F

B C

TOP OF LINTEL BAR

FIREPLACE FRONT

STEEL FRAMING STANDOFFS

NON-COMBUSTIBLE ZONE. DO NOT INSTALL ANY COMBUSTIBLE MATERIAL, ELECTRICAL WIRING OR GAS PLUMBING IN THIS AREA.

Mantel Clearance Chart

  • MANTEL CLEARANCE

A

9″

B

6″

C

3″

** MANTEL DEPTH

D

12″

E

6 3/4″

F

1 1/2″

Figure 6: Mantel clearances.

CEILING
24″ *

AODR JMAACNETNETLWSUAPLPLORT 4″

29 3/4″
COMBUSTIBLE FLOOR

6″
COMBUSTIBLE HEARTH
UNIT MAY BE RECESSED UP TO 6″ WITH NONCOMBUSTIBLE MASONRY TYPE MATERIAL

Figure 7: Mantel.

Minimum Clearances: Side standoffs ………………………………………………. 0 in. Back standoffs ……………………………………………… 0 in. Top standoffs ……………………………………………….. 0 in. Bottom of appliance ………………………………………. 0 in. Adjacent side wall…………………………………………. 4 in. Ceiling to appliance …………………………………….. 24 in. *Mantel to appliance ……………… ……….See Figure #6 **Maximum Mantel extension .. ……….See Figure #6 Mantel support……………………………………………… 4 in. Vertical vent pipe ……………………………………1 3/4″ in.

(0 mm) (0 mm) (0 mm) (0 mm) (102 mm) (610 mm)
(102 mm) (45 mm)

TCWS.54OD W SCREEN_181121-20

7

100005095

Installation Requirements
The Town & Country Fireplace installation and venting must conform to the current CAN/CGA-B149 installation code (in Canada) or the current National Fuel Gas Code, ANSI Z223.1 (in the USA), and approved per local codes. Only qualified (licensed or trained) personnel should install this product. In the state of Massachusetts, only a licensed Plumber and Gas Fitter may install this product.
Window Frame Removal
Warning: Turn off the fireplace, and allow ample time for the unit to cool before proceeding. Caution: The ceramic glass is very fragile, and should be handled with care. The window frame is held in place by two spring-loaded latches that are operated by a one-piece latch handle. 1. Remove the TC Finishing Touch Trim Kit from the window frame. (If installed) 2. Using a screwdriver or other similar object, push against the notch in the top of the latch and grab the bottom of the
latch handle as it protrudes. Lift handle until latch hook disengages (Figure 8) & (Figure 9). Repeat for other side while holding glass so it does not tip out. 3. Tilt the top of the window frame out to clear the top edge of the unit. Grasp the sides of the frame and lift up and out to disengage from its bottom track. 4. Place the window frame in a safe place to avoid damage. 5. Re-assemble in reverse order. Latch handle should snap into place and be flush with window frame when engaged correctly. 6. Reinstall Trim Kit if required.
TIP: To ensure glass is properly latched, grasp the top left and right sides of the glass frame, under moderate pressure it should pull forward and return to original position evenly on both sides.
HANDLE

Figure 8: Accessing handle.
100005095

Figure 9: Handle.

8

TCWS.54OD W SCREEN_181121-20

Standoffs
The standoffs are shipped loose inside the fireplace and must be installed on the top and the side of the fireplace as shown in (Figure 10). Do this once the fireplace is on site and in position.
TOP STANDOFFS

SIDE STANDOFF (THIS SIDE ONLY)

CONTROL BOX

HANDLE
Figure 10: TCWS54CODE standoffs.
Locating The Fireplace
In planning the installation for the fireplace, it is necessary to determine where the unit is to be installed, location of vent system and where gas supply piping may be plumbed. Various installations are possible, such as, into an existing wall, a corner, a built-in wall or a wall projection (Figure 11). Due to high temperatures, do not locate this fireplace in areas of high traffic or near furniture or draperies. The minimum clearances from the fireplace to combustible surfaces must be adhered to and are shown in Figure 6 & 7.

EXAMPLES OF COMMON LOCATIONS SEE FIG #15 FOR DIMENSIONS

Figure 11: TCWS54CODE Possible locations.

TCWS.54OD W SCREEN_181121-20

9

100005095

Framing and Finishing

Note: The fireplace should be in place and venting installed before framing in or building an enclosure around the unit.
The Town & Country fireplace must be framed in as described below or totally enclosed with non-combustible material, such as facing brick.
Determine the total thickness of facing material to be used. The framing Kit is adjustable, and will allow for 3/8″ to 1-3/8″ finishing surface to be flush with the front of the unit. If preferred, additional masonry type non- combustible material can be installed above and to the sides up to 6 inches forward of the appliance.
The finishing material must not interfere with glass frame access.
A Steel Stud Framing Kit is supplied with the fireplace and must be used unless the fireplace is totally enclosed with non-combustible material. Assemble the framing kit as per the instructions on pages 11 – 13

of this manual. Attach the steel frame to the fireplace once the fireplace is in its final position. Set the depth and secure the steel frame to the framing brackets on each side of the unit. Ensure that the studs are set back far enough to allow for thickness of finishing surface.
The sides, back and top of the fireplace can be framed in up to the steel studs and the fireplace standoffs using conventional lumber. Consult local building codes for specific requirements.
Due to high temperatures, non-combustible backer board, such as cement board or its equivalent, must be used to sheet in the front of the fireplace, extending 12″ below, 12″ above and 9 5/8″ to the side of the framing edge bars (Figure 13). Standard sheetrock (dry wall) may be used beyond this.
If the backer board is not to be finished with other non-combustible material such as tiles, it is recommended that the instructions in (Figure 15) be followed closely.

Fabricate and install appropriate flashing to local building code.
Note: Installing unit without flashing installed will void the warranty
Note: Provide proper drainage to divert water underneath the unit
Chase Insulation: When installing this fireplace against a non-insulated exterior wall or chase, it is recommended that the outer walls be insulated to the same degree as other exterior walls. Do not place fireplace directly against the insulation. Cover the insulation and plastic vapour barrier with a solid surface, such as dry wall (sheetrock). Consult local codes. Do not insulate or use plastic vapour barrier within the framing kit.
CAUTION: SEE (Figure 15) BEFORE PROCEEDING.

NON-COMBUSTIBLE ZONE. DO NOT INSTALL ANY COMBUSTIBLE MATERIAL, ELECTRICAL WIRING, INSULATION, PLASTIC VAPOR BARRIER OR GAS PLUMBING WITHIN THE STEEL STUD FRAMING

Steel Stud Framing Kit Dimensions (Supplied with fireplace)

ALL OTHER FRAMING CAN

BE DONE WITH

76″

CONVENTIONAL LUMBER

55″

100005095

Figure 12: TCWS54CODE with supplied steel frame.

10

TCWS.54OD W SCREEN_181121-20

Non-Combustible Board Detail
NON-COMBUSTIBLE BOARD
12″

NON-COMBUSTIBLE MATERIAL MUST EXTEND 12″ ABOVE, 9 5/8″ TO THE SIDES AND 12″ BELOW THE FRAMING EDGES.

9 5/8″ 12″

Figure 13: TCWS54CODE Non-combustible board dimensions.

Non-Combustible Recessed Installation Detail
NON-COMBUSTIBLE BOARD

STEEL STUDS

NON-COMBUSTIBLE MASONRY TYPE MATERIAL
MAXIMUM FACING DEPTH
Figure 14: Recessed installation detail.

Minimum Combustible Framing Dimensions

11 5/16″

76 1/4″ 3/8″ – 1 3/8″

23 5/8″ to
24 5/8″

84″ to 85 1/2″ 33 3/8″
47 1/8″
76″ 119″ 121″

Figure 16: WS54 OD w Screen framing dimensions.

TCWS.54OD W SCREEN_181121-20

11

IF FINISHING THE WALL ABOVE THE UNIT WITH PAINT, THE FRAMING KIT SHIPPED WITH THE UNIT SHOULD BE DISCARDED. IT IS RECOMMENDED TO USE FULL SHEETS OF CALCIUM SILICATE BOARD OR ITS EQUIVALENT AND FULL LENGTH METAL STUDS TO FINISH AND FRAME AROUND THE UNIT. FOLLOW THE MANUFACTURERS MOUNTING AND FINISHING INSTRUCTIONS CLOSELY. NOTE: IT IS RECOMMENDED TO PREDRILL MOUNTING HOLES IN THE BOARD PRIOR TO SECURING TO THE FRAMING. THIS WILL PREVENT THE BOARD FROM CRACKING.
NON-COMBUSTIBLE BOARD
Figure 15: Non combustible calcium silicate board.
55 1/4″
76 1/4″
100005095

Steel Stud Framing Kit

1 2 3 4 5 6
7 Figure 17: TCWS54CODE Framing kit parts.

Each Kit Contains:

Item

Part #

Description

1 5049.9912 SCREW, WAFER #8 x 1/2

2 8293.4

STUD, SIDES 55″ L

3 8293.2

STUD, OUTER SIDES 55″ L

4 8293 5 8293.6 6 8293.8

STUD, UPPER/LOWER 75 1/4″ L
INNER CROSS BRACE 56 5/8″ L
STUD, CENTER 25″ L

7 8293.9

LOWER CROSS BRACE 56 5/8″ L

Qty. Pkg 40
2
2
2
1
3
1

100005095

12

TCWS.54OD W SCREEN_181121-20

Frame assembly
1. On a flat surface, lay one 76″ (#4) stud on its end and at the top of your working area. This will be the top most horizontal stud.
2. Position all three 25″ studs (#6) vertically with the center stud aligning with the center of the above (#4) horizontal stud. Use supplied screws to affix the tops of the vertical studs to the horizontal stud.
3. Position two – 55″ studs (#2) on either side of the three vertical studs (#6), centering them so that they are approximately 56″ from each other while being evenly centered in relation to the top (#4) stud. Use supplied screws to affix the tops of these studs to the top horizontal stud.
4. Position stud (#5) horizontally along the bottom ends of the three 25″ (#6) vertical studs while aligning the ends of this stud with the two 55″ (#2) studs. This stud has an angled bottom which makes one side of the stud higher on one edge than the other. The higher edge will face toward the fireplace once assembled. Use supplied screws to affix this stud to all five vertical studs (#2) & (#6).
5. Position stud (#7) horizontally approximately 12″ from the bottom of the two vertical studs (#2). Make sure that the slot side is facing up. Affix the ends of this stud to the vertical (#2) studs.
6. With the tabs bent outward, position the two 55″ (#3) studs vertically, one at each end of the top most horizontal stud (#4) and affix.
7. Place the final 76″ (#4) horizontal stud at the bottom of the assembly and affix to the four vertical studs.
8. Turn the assembly over and affix the remaining screws to the other side of the frame.
FRONT VIEW (slightly angled)
4

2 3

6

6

LONG EDGE UP

5

BEND OUT FRAMING TABS TO FRONT 6
2
3

SLOTS UP 7

WIDE FACE FORWARD
SCREW INTO SIDE

4

Figure 18: TCWS54CODE Steel frame assembled.

TCWS.54OD W SCREEN_181121-20

13

100005095

The lintel on the TCWS 54 Outdoor w/ screen is in a fixed position on the fireplace and there is no adjustment to move the lintel toward you or away from you once the fireplace has been located in its final position. Instead, the fireplace itself must be manoeuvered so that the front face of the lintel determines the final position of the fireplace.
The Framing Kit is adjustable and allows for a 1inch of adjustment in mounting depth along the Framing Brackets. Use this adjustability to help with the desired installation of the front facing material.
The thickness of the facing material, could be 3/8″ inch calcium silicate board or a 1 3/8″ rock facing and must be taken into consideration before settling on a final position of the fireplace.
1. Attach the assembled frame to the fireplace
· Bend out the framing mounting tabs 90 degrees before inserting the unit into its framed housing (Figure 20).
· Align the assembled frame between the fireplace framing brackets (Figure 19).Install screws at the fastening points. Set the depth of the Steel frame based on the desired depth of facing and tighten the screws.(There are access holes in the outer side studs (3) if needed).

2. Secure to Existing Framing
· Using the Framing Mounting Tabs, secure the frame assembly to the wood frame through the holes in the tabs.

Figure 19: Framing bracket fastening points.

Figure 20: Framing tabs bent out.

100005095

14

TCWS.54OD W SCREEN_181121-20

Install Non-Combustible Board (not supplied)
This fireplace may be recessed up to a maximum depth of 6″, this recess must be constructed from non combustible material. The space between the outside lintels and the firebox must be completely free of any obstructions or debris and the window with trim fitted must be able to move freely. No building material is permitted to protrude past the lintel bars attached to the fireplace under ANY circumstance.
NON COMBUSTIBLE FINISH MATERIAL

FRAMING EDGES GLASS FRAME
Figure 21: Non-combustible facing area.

Screen Installation

Insert the tab into the Slot in Lintel

Figure 22: Screen Tab install.ai

Figure 23: Screen Magnets.ai

1. Install the screen with the tabs down and on the back. Wth the Screen tilted towards you at the top, insert the tabs into the two slots located in the bottom section of the Lintel.
2. Tilt the screen into place until it contacts the magnets and is held in place.

TCWS.54OD W SCREEN_181121-20

15

100005095

Honeywell Control Valve Plumbing and Electrical

The gas control system is located on the right hand side of the firebox behind an access panel and the decorative firebox panel (if installed). The fireplace is operated via a wall switch.
The wall control is connected to the fireplace by a 14-2 AWG wire, not supplied with the fireplace.
Installation
1. Place the fireplace in the desired location.
2. Remove the window from the fireplace.
3. Remove access panel from right hand side of the firebox (Figure 24).
4. Remove the cover from the electrical box (Figure 25).
5. Run one 110 V. AC switched electrical supplies to the control box and connect to the transformer (Figure 26). The fireplace operates on 24V AC supplied by a transformer rated at 110 volts, 60Hz. See wiring diagram on page 29 for correct connections on terminal block.
6. Connect the gas supply to the valve (Figure 27).

ACCESS PANEL Figure 24: Access panel location.
ELECTRICAL BOX COVER
Figure 25: Electrical box cover.
TERMINAL BLOCK, ELECTRICAL CONNECTIONS
Figure 26: Electrical connections.

100005095

GAS INLET

Figure 27: Gas inlet.

16

TCWS.54OD W SCREEN_181121-20

Gas Supply

Caution: The gas line should be installed by a qualified service person in accordance with all building codes. This section is intended as a guide for qualified technicians installing this appliance. Consult local and/or national building codes before proceeding.
· Gas supply line access holes are located at the top and left sides of the Control Box. Gas valve inlet accepts a 3/8″ N.P.T. fitting. Correct gas line diameter must be used to assure proper operation and pressure.
· The fireplace has an input rate of 54,900 BTU/HR on both Natural Gas and Propane.
· NOTE: A sediment trap, as per national fuel gas code, must be installed in the gas supply line no more than 6 feet from the gas control valve to minimize the possibility of any loose scale or dirt within the gas supply line from entering the control valve.
· DO NOT HARD PIPE GAS LINE TO VALVE. A method of disconnecting the valve from the gas line such as a union or flare fitting must be provided to allow for repair or replacement of the gas valve.
Check local codes for additional requirements.
1. Connect the gas supply to the valve (Figure 27).
2. Turn on the gas supply and check that all connections are tight and leak free.
WARNING: Use EXTREME CAUTION when using soap and water to do a leak test on the valve/ fittings. There are electronics around and below the valve, that can/will be damaged if they come in contact with water.
WARNING: The access panel including gasket must be reinstalled after conversion/installation or servicing has been completed. Failure to do so will cause overheating and premature failure of the control system.
Gas Pressure Check
Note: To test the gas pressure, turn off the gas supply before removing the plug from the supply pressure test port or manifold pressure test port.
Verify gas pressures with the fireplace lit and on the highest setting.
Please refer to the Burner Installation Manual for gas pressure testing procedure.

Correct gas pressure requirement
Natural Gas Propane

Min. Pressure
(For purpose of input adjustment)
Max. Pressure

5.0″ WC 13.9″ WC

12.5″ WC 13.9″ WC

Manifold Pressure Maximum Minimum

3.8″ WC 2.1″ WC

11″ WC 5.5″ WC

TCWS.54OD W SCREEN_181121-20

17

SUPPLY PRESSURE MANIFOLD PRESSURE
Figure 28: Test ports.
100005095

Venting

Before installing venting for this unit, the installer should read these instructions to insure that the proper vent configuration has been selected. Use only Town and Country Termination kits #:TCVT.RTA – Roof Termination Kit
Vent system components approved for use with the Town and Country Fireplace are shown on page 21.
Various combinations of vent runs may be used. Refer to (Figure 29) for details. For optimum performance and flame appearance, keep the vent length to a minimum and limit the number of elbows. Connections between each vent system component must be tightly joined, secured with sheet metal screws and sealed with high temperature self adhesive tape.
VENT SUPPORTS: A minimum of 1 support every 4′ must be used.
CAUTION: UNDER NO CONDITION SHOULD COMBUSTIBLE MATERIAL BE CLOSER THAN 1 3/4 INCHES FROM ANY PART OF THE VENT PIPE.
Roof Termination Venting Chart

48′ MAX.
Various combinations of vent runs may be used.

Refer to (Figure 29) for details. For optimum

performance and flame appearance, keep the

40′

vent length to a minimum and limit the number of

elbows. Connections between each vent system

component must be tightly joined, secured with

sheet metal screws and sealed.

CAUTION:
Under no condition should combustible material be closer than 1 3/4 inches from any part of the vent pipe.
Only 45º elbows can be used in this vent system. Maximum number of elbows is 2.

20′

MINIMUM VERTICAL

10′

VENT HEIGHT 10 ft (3m)

If using an elbow, there must be a minimum of 18″ ( 45cm) of vertical vent before installing the elbow.

4′ MAX.

100005095

Figure 29: TCWS54CODE Venting chart.

18

TCWS.54OD W SCREEN_181121-20

A 14 1/2″

B

Figure 30: Roof opening frame.

Size of the opening will have to increase with the pitch of the roof to ensure a 1 3/4″ inch air space clearance between vent pipe and combustibles.

Roof Pitch

A

B

0/12 4/12 6/12 8/12 12/12

14 1/2″ 16 1/2″
18″ 19 3/4″
24″

7 1/4″ 8 3/4″
10″ 11″ 13 3/4″

TCWS.54OD W SCREEN_181121-20

Ceiling Opening
1. Determine the exact position of the fireplace so that the vent pipe is centered (if possible) between two building framing members. Lay out the vent system path, minimizing the number of elbows and length of vent. Consult your local building codes prior to proceeding.
2. Cut and frame a 14 1/2″ opening in the floor, ceiling or roof where the vent system will pass. Size of the opening in the roof may need to be increased as the pitch of the roof increases. Avoid cutting rafters.
Ceiling Firestop
Where a vent pipe passes through a floor or ceiling, a ceiling firestop (TCVT. THIMA) must be used to retain insulation and maintain proper clearances.
From below, push the ceiling firestop through the opening and secure in place. If the firestop is used to penetrate a floor, the outer shield may be trimmed in length. If the firestop penetrates into an attic, leave the shield full length to keep insulation away from the vent pipe. Additionally, after the vent pipe is in place, install a storm collar on top of the shield. This will prevent loose insulation from falling into the area between the vent pipe and the shield.

VENT PIPE
ROOF SUPPORT BRACKET (TCVT.93915)
19

Vent Pipe
1. Install the first section of vent pipe into the collar on top of the fireplace. Secure in place with screws and seal with approved “High Temperature” self-adhesive aluminium tape provided.
2. Continue adding vent pipe lengths up and through the firestop(s) and through the roof. The vent pipe must extend above the roof according to the sloped roof pitch table on page 21.
Seal the vent pipe as per “Vent Pipe Sealant” section.
Roof Support Bracket
Slip the roof support bracket down over the vent pipe. Rotate the 90° brackets to accommodate roof pitch. Attach the brackets to the roof joists with nails or building screws. Tighten the band around the vent pipe and secure in place with screws.
Figure 31: Roof support bracket.
100005095

Roof Vent Terminal
1. Place the roof flashing over the vent pipe, secure and seal it to the roof using the methods and materials appropriate for the type of roof on the building. Shingle roof example shown (Figure 32).
2. Place the storm collar down over the vent pipe until it is level. Tighten storm collar for a snug fit. Apply a thick horizontal ring of mastic around the pipe at top of the storm collar (Figure 32).
3. Lower the roof vent terminal cap over the vent pipe and secure in place with screws provided (Figure 32). Seal screw heads and joints with caulking to prevent any moisture entering the venting system.

Note: Adjustable for various roof pitches, from flat roof to 12/12 pitch roof.
MASTIC

VERTICAL TERMINATION CAP (TCVT.9365)
VENT PIPE STORM COLLAR (TC42.90665)

100005095

FLASHING

Figure 32: Roof vent terminal.

NOTE: ADJUSTABLE FOR VARIOUS ROOF PITCHES, FROM FLAT ROOF TO 12/12 PITCH ROOF.

20

TCWS.54OD W SCREEN_181121-20

Vent Terminal Clearance

Minimum clearances to the vent terminal must be maintained VENT TERMINAL MINIMUM CLEARANCES

as shown in (Figure 33). Measure clearances to the nearest

TO ADJACENT STRUCTURES

edge of termination hood.

NOTE: Vent terminal must not be recessed NOTE: LOCAL CODES OR REGULATIONS MAY REQUIRE DIFFERENT CLEARANCES.

36″ (91.5 cm)

24″ (61 cm)

Terminal to Sloped Roof

Pitch Table

(minimum)

ft

m

Flat to 6/12

1.00

0.30

Over 6/12 to 7/12

1.25

0.38

Over 7/12 to 8/12

1.50

0.46

Over 8/12 to 9/12

2.00 0.61

Over 9/12 to 10/12

2.50 0.76

Over 10/12 to 11/12

3.25 0.99

Over 11/12 to 12/12

4.00 1.22

See: Roof pitch table

Figure 33: Roof terminal clearances.

Vent System Components Town & Country
12″ Pipe Length……………………………………….TCVT.811X12 18″ Pipe Length……………………………………….TCVT.811X18 24″ Pipe Length……………………………………….TCVT.811X24 48″ Pipe Length……………………………………….TCVT.811X48 12″ Adjustable Pipe Length………………… TCVT.811X12ADJ 45° Elbow ………………………………………….. TCVT.811XLB45 Wall/Offset Support …………………………………TCVT.811XOS A minimum of 1 support every 4′ must be used.
Roof Termination Kit …………………………………….. TCVT.RTA Wall Shield/Ceiling Firestop………………………..TCVT.THIMA
Roof Flashing, Adjustable ……………………. TCVT.811FLADJ Roof Flashing, Flat ………………………………. TCVT.811FLFLT Roof Flashing, Steep …………………………… TCVT.811FLSTP
or any flashing that fits 11″ pipe

TCWS.54OD W SCREEN_181121-20

21

100005095

Vent Pipe Sealant

APPROVED “HIGH TEMP.” SELF-ADHESIVE TAPE (SUPPLIED)

VENT PIPE

Figure 34: Sealing the vent with tape.
All outer joints of the vent pipe must be sealed with the approved “High Temperature” self-adhesive aluminium tape provided. Wrap the tape completely around the joint and press firmly in place. Inner pipe does not need to be sealed.

100005095

22

TCWS.54OD W SCREEN_181121-20

Vent Restrictor Adjustment

The vent restrictor is located on the underside of the firebox top. The unit leaves the factory with the vent restrictor open. The restrictor is built into the appliance for secondary air flow adjustment. Adjustment enables tuning the airflow for optimum flame appearance and performance for a wide variety of vent configurations.

Setting:

·

Determine the vent height.

·

Determine the vent horizontal length.

·

From the chart determine the restrictor position.

Refer to the chart (Figure 35) for the correct position of restrictor for the vent configuration of your installation. Restrictor positions are based upon lab tests. The ideal position may vary slightly with installation.

Restrictor position is too closed if the flame has the following characteristics:

·

Flame is excessively tall and lifting.

·

Flame lacks movement.

·

Flame soots.

Restrictor position is too open if the flame has the following characteristics:

·

Flame height is low.

·

Flame has excessive movement.

To adjust the restrictor:

·

Loosen the screw holding the restrictor.

·

Move the restrictor to its intended opening.

·

Re-tighten the screw.

WALL AND ROOF TERMINATION RESTRICTOR POSITION

48′

1″ OPEN

40′ 2″ OPEN

30′

4″ OPEN

20′ FULLY OPEN

10′ 0

1

2

3

4

Figure 35: Restrictor position chart.

OPENING

VENT RESTRICTOR

TCWS.54OD W SCREEN_181121-20

Figure 36: Vent restrictor.

23

100005095

Firebox Panels Installation

1. Remove the 2 inner screws from the upper heat shield (Figure 37).

2. Slip the top porcelain panel into the lip at the front of the firebox and tip the panel up to align with the screw holes. Secure with the previously removed screws (Figure 38).

Insert the back panel into the firebox by tilting the panel and rest the panel on the seat tabs at the back of the firebox (Figure 39).

3. While supporting the back panel insert the left side panel into the firebox. Position the top of the panel against the side of the unit, inserting the top panel tab into the slot at the top of the side panel and slide the bottom into position (Figure 40).
NOTE: Seat tabs can be lowered if the rear panel is tight.
NOTE: Centering tabs on the panel should be located at the outside of the seat tabs.
NOTE: Notch at bottom of side panel faces to front of unit.
4. Repeat step 4 for the other side panel.

Figure 37: 2 Inner screws location.
SEAT TABS
Figure 39: Rear panel seat tab location.

Figure 38: Securing top porcelain panel.
SEAT TABS
Figure 40: Seat tab.

5. Place the front panel on the front lip of the firebox, wide flange facing the front (Figure 41) (Proceed to step #7 if you are installing a TCWS.54NG03.C2 Black Diamond burner with this unit.)
NOTE: Install burner now.

Figure 41: Front panel location.

6. Place the other front panel piece at the rear of the firebox with the wide flange facing to the rear against the back panel.

100005095

24

TCWS.54OD W SCREEN_181121-20

Lighting Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
A. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor. WHAT TO DO IF YOU SMELL GAS: – Do not try to light any appliance.

– Do not touch any electric switch; do not use any phone in your building. – Immediately call your gas supplier from a neighbour’s phone. Follow the gas supplier’s instructions. – If you cannot reach your gas supplier, call the fire department. C. Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. D. Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance & to replace any part of the control system & any gas control which has been under water.

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information above on this label. 2. Set wall switch/ hand held remote to lowest setting. 3. This appliance is equipped with an ignition device which
automatically lights the pilot. Do not try to light the pilot by hand. 4. Push the “On/ Off” switch to the fireplace Off. 5. Allow sufficient length of time (minimum 5 minutes) for any gas in the combustion chamber to escape. If you still smell gas, STOP! Follow “B” in the safety information above on this label. If you don’t smell gas, go to the next step.

6. Push the “On/ Off” switch to turn the fireplace on. – If the burner does not light, repeat steps 4 through 6. – If the burner will not light or stay lit after several tries,push the “On/ Off” switch to the fireplace off and call your service technician or gas supplier. Note: Sufficient time must be allowed for air to escape from lines if the unit is being lit for the first time.
7. Set fireplace to desired setting by using either the wall switch or hand held remote.

TO TURN OFF GAS TO APPLIANCE

1. Set wall switch / hand held remote to lowest setting. 2. Push the “on/ off” switch to the “Off” position.

3. Turn off all electric power to the appliance and remove backup batteries if service is to be performed or for extended shutdown.

Due to high surface temperatures, keep children, clothing and furniture away. Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance. A cause de la temperature elevee des parios, tenir eloignes les enfants, les vetements et les meubles. Maintenir propres le bruleur et le compartiment de commande. Voir les instructions relatives a l’installation et au fonctionnement qui accompagnent l’appareil.

CAUTION: Hot while in operation. Do not touch. Severe burns may result. Keep children, clothing,
furniture, gasoline and other liquids having flammable vapours away. Keep burner and control compartment clean. See installation and operating instructions accompanying the appliance.
ATTENTION: L’appareil est chaud lorsqu’il fonctionne. Ne pas toucher l’appareil. Risque de
brûlures graves. Serveiller les enfants. Garder les vêtements, le meubles, l’essence ou autres liquides produisant des vapeurs inflammables loin de l’appareil. S’assurer que le brûleur et le compartiment des commandes sont propres. Voir les instructions d’installation et d’utilisation qui accompagnent l’appareil.

310106

5051.173

5-TC30

First Fire
When lit for the first time, the fireplace will emit a slight odour for a couple of hours. This is due to the curing of paints, sealants and lubricants used in the manufacturing process. This condition is temporary. Open doors and windows to ventilate area. Odour caused by the curing process may cause discomfort to some individuals.
It is normal for fireplaces fabricated of steel to give off some expansion and/or contraction noises during the start up or cool down cycle. Similar noises are found with your furnace ,heat exchanger or cook stove oven.

TCWS.54OD W SCREEN_181121-20

25

100005095

Maintenance
CAUTION: Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool before servicing appliance. It is recommended that the fireplace and its venting should be inspected at least once a year by a qualified service person.

Glass Panel:

Warning: Do not operate fireplace with glass panel removed, cracked or broken. Replacement of the glass panel should be done by a licensed or qualified service person.

Do not strike or otherwise impact the glass in anyway that may cause it to break. If the glass becomes cracked or broken it must be replaced before using the fireplace. Replacement glass can be obtained from your nearest Town & Country Fireplaces dealer. The size required is 52″ x 16″ x 5mm. Use ceramic glass only. Do not substitute with any other type.

To remove broken glass, remove window frame as noted in “Window Frame Removal” section.

Unclip the Glass Retainer Clips located at the top and sides of the Window Frame. Pull the top edge of the glass out of the frame first, then lift it up and out of the bottom edge.

Install the new piece of glass with the gasket into the frame so that the thicker bead of gasket faces the fireplace.

Re-install glass retaining clips.
Annual Inspection:
a) Remove glass panel and pebble assemblies. Inspect pebble and burner assemblies for soot buildup. If excessive buildup of soot is present, have a qualified service person inspect and adjust unit for proper combustion. Clean logs and burner with a brush or vacuum cleaner, paying close attention to burner ports.

b) Check the pilot system for proper flame size and operation. Clean pilot free of soot, dust or any other deposits.

c) Check that the vent pipe and vent terminal are open and free from blockage or debris. If the venting is disassembled for cleaning, it must be properly assembled and re-sealed. Refer to VENTING section for proper procedure.

d) Check glass panel gasket, replace if necessary. It is important that the glass seal be maintained in good condition.
e) Check and replace batteries as needed.

FLAME SENSOR

PILOT FLAME

Note: The appliance area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids.
Periodically:
a) Viewing glass may be cleaned as necessary with fireplace glass cleaner.

b) Exterior finish may be cleaned with mild soap and water.

CAUTION:
Do not use abrasive cleaners on glass or any other part of the fireplace.

Do not clean glass when hot.

Figure 42: Honeywell pilot.

100005095

26

TCWS.54OD W SCREEN_181121-20

TCWS.54CODE Replacement Parts

(WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION)

ITEM DESCRIPTION

PART NO.

ITEM DESCRIPTION

PART NO.

1 TCWS BODY ASSEMBLY ……………………..22030014 #2 GLASS ASSEMBLY (c/w gasket)….

GLAS.2062ASSY #3 FRAMING KIT ………………………………TCWS.54FRKIT #4 PANEL SETS
BLACK PORCELAIN……………………………22200062 BROWN PORCELAIN………………………….22200060 COPPER PORCELAIN…………………………22200061 TITANIUM PORCELAIN ……………………….22200063

6 ORIFICE (2pcs)………………………………………5022.87 #7 MAIN GAS SUPPLY TUBES (3pcs)

…………5019.223 #8 BURNER SUPPORT ……………………………………9498 #9 PILOT ASSEMBLY………………TCCV.WS54ODPILOT #10 1/2″ TEE ……………………………………………..5019.013
*NOT SHOWN

1

1a

2

9

8

6

10

7

1b

3

HONEYWELL CONTROL ASSEMBLY – See Page 28 3a

4

4d

4b

4c

4a

KIT CONTENTS: #1. TCWS BODY ASSEMBLY 1a SPRING LATCH ASSEMBLY (2) 1b CONTROL BOX

2 GLASS ASSEMBLY (c/w gasket)

3 FRAMING KIT 3a STEEL STUDS

TCWS.54OD W SCREEN_181121-20

4 PANEL SETS 4a PANEL, FRONT BASE 4b PANEL, LEFT SIDE 4c PANEL, UPPER 4d

PANEL, REAR 4e PANEL, RIGHT SIDE
27

4e 100005095

Honeywell Control System Replacement Parts

(WHEN ORDERING, INCLUDE PART NUMBER WITH DESCRIPTION)

ITEM DESCRIPTION

PART NO.

1 CONTROL ASSEMBLY KIT …………… TCRP.9000 #2 BULKHEAD ASSEMBLY KIT ………….

TCRP.8133 #3 CONTROL BOX KIT…………….. TCRP.92762WLD #4 TEST FITTING ……………………………….. 5019.104

1c 1b

1 #3

1l 1d
1a

2a 2e

2c

2d

1j

1f 1g

2b 1k

1m 1h

1e

4

2

KIT CONTENTS: #1 CONTROL ASSEMBLY KIT
1A VALVE C/W FITTINGS 1B 1/4″ FLEX TUBE 1C 1/2″ FLEX TUBE 1D CONTROL MOUNTING BRACKET 1E IGNITION MODULE 1F ELECTRICAL TERMINAL BLOCK 1G ELECTRICAL TRANSFORMER 1H PRESSURE TEST ASSEMBLY 1J TC36ST PRESSURE TEST PLATE 1K TC36ST LOCKING PLATE 1L WING NUTS (2) 1M TRANSFORMER BOX COVER PLATE
REMOTE RECEIVER (NOT SHOWN)

2

BULKHEAD ASSEMBLY KIT

2A

INLET PLATE

2B

INLET PLATE GASKET

2C

ELEC BULKHEAD GASKET

2D

1/2″ BULKHEAD FITTING

2E

1/4″ BULKHEAD FITTING

3 CONTROL BOX KIT

4 TEST FITTING

100005095

28

TCWS.54OD W SCREEN_181121-20

Wiring Diagram

VR8204M1091 HONEYWELL VALVE
MV
PV/MV
PV GAS CONTROL
TERMINAL

BLACK WHITE ORANGE
GREEN

S86 VALVE MODULE
MV
PV/MV PV
GND
24VAC COM 24VAC HOT

WHITE ORANGE

24VAC

TRANSFORMER

WHITE

BLACK

SPARK/FLAME SENSOR WIRE

BURNER SWITCH (NOTSUPPLIED)

115VAC HOT 60Hz

(STANDAR AWG 14-2 WIRE OR EQUIVALENT) (NOT SUPPLIED)

115VAC COMMON 60Hz

PILOT

TCWS.54OD W SCREEN_181121-20

29

100005095

STORM COLLAR TC42.90665

Roof Termination Kit

16 1/2″

VERTICAL TERMINATION CAP TCVT.9365
9″

ROOF SUPPORT BRACKET TCVT.93915
Figure 43: Vent terminal kit.

CEILING FIRESTOP TCVT.THIMA

100005095

30

TCWS.54OD W SCREEN_181121-20

Vent Pipe Dimensions

9 1/2″

10 15/16″

TCVT.811X12ADJ

11″ 12″ Pipe…………….. 10 1/4″ 18″ Pipe…………….. 16 1/4″ 24″ Pipe…………….. 22 1/4″ 48″ Pipe…………….. 46 1/4″

  • 11 1/8″ TCVT.811X

45

12 9/16″
13 1/8″ TCVT.811XLB45
Figure 44: Pipe dimensions.

TCWS.54OD W SCREEN_181121-20

31

100005095

Vent Offset Chart

A

B

C

12″ PIPE

18 5/8″

18″

18″ PIPE

22 7/8″

22 3/8″

A

24″ PIPE 10 7/8″ 48″ PIPE

27 1/8″ 44 1/16″

26 1/2″ 43 1/2″

1 1/4Ó

11 3/8″

ADDING AN ADJUSTABLE SECTION TO PIPE WILL INCREASE OFFSET BY 2 1/8″ TO 6 3/4″

1 1/4″

C B

A

B

C

12″ PIPE

13 7/16″

23 1/4″

18″ PIPE

17 9/16″

27 5/8″

A

24″ PIPE

21 7/8″

31 3/4″

48″ PIPE

38 3/4″

44 7/8″

C

ADDING AN ADJUSTABLE SECTION TO PIPE WILL INCREASE OFFSET BY 2 1/8″ TO 6 3/4″

1 1/4″

B

Figure 45: Vent offset chart.

100005095

32

TCWS.54OD W SCREEN_181121-20

Quick Panel Removal for Valve Service
FRONT PANEL BASE

Figure 46: Front panel base.

Figure 47: Clearing the securing tab.

Figure 48: Right panel.

Figure 49: Access panel.

1. Remove front panel base. Also remove rear panel base if Black Diamond Burner is fitted (Figure 46). 2. Push up on the heat shield, at the right end of the unit near the middle, enough to clear the securing tab (Figure 47). 3. Pull the top of the right panel toward the center of the unit using caution not to scratch the back panel (Figure 48). 4. Once the right panel is tilted inwards it can be lifted clear of the burner tray and removed.
NOTE: The right hand side rock cluster may need to be removed to prevent damage while working through the access hole. Covering the sand with paper or cardboard will also minimize disturbance during the servicing process. 5. The access panel is now visible (Figure 49) and can be removed. 6. Reassemble in reverse order.

WARNING: The control box shield, access panel and gasket must be replaced. Failure to do so will overheat and cause premature failure of the control.

TCWS.54OD W SCREEN_181121-20

33

100005095

Rating Label Location

NOTE: The Safety Label is located on a plate found in a slot between the left hand side lintel and the left hand side window frame. This plate is attached to the side casing with a cable.

MODEL/MODELE: TCWS54CODE

VENTED OUTDOOR GAS FIREPLACE – NOT FOR USE WITH SOLID

FUEL. FOYER AU GAZ À ÉVACUATION – NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE

1

DECORATIVE APPLIANCE: NOT INTENDED AS A SOURCE OF HEAT

APPAREIL DÉCORATIF: NON PRÉVU COMME SOURCE DE CHALEUR

ANSI Z21.97-2012 Outdoor Decorative Gas Fireplaces. CSA 2.41-2012 Outdoor Gas Fireplaces
Certified for / Certifié pour Canada and U.S.A.

This appliance is Equipped For Use With / Cet Appareil est Equipe Pour Utilise Avec:

NATURAL GAS/ DU GAZ NATUREL

LP GAS/ DU GAZ LP

FOR USE WITH EN CASE D’EMPLOI AVEC:

NATURAL GAS/ DU GAZ NATUREL

LP GAS/ DU GAZ LP

SERIES/SERIE:
C3
MADE IN CANADA FABRIQUE AU CANADA

Minimum supply pressure / Pression minimum d’alimentation: (For the purpose of input adjustment / dans le but de régler l’alimenation) Maximum supply pressure / Pression maximum d’alimentation:
Manifold pressure / Pression de la tuyauterie: Maximum
Orifice Size / Diametre de l’injectuer: Input BTU/hr (kW) / Entree BTU/h (kw)

5.00 in/wc 5.00 po/c.e. (1.24 kPa )
13.90 in/wc 13.90 po/c.e. (3.46 kPa )
3.80 in/wc 3.80 po/c.e. (0.95 kPa )
FRONT: NCx2 REAR:
Max: 54,900.00 (16.09) Min: 46,200.00 (13.54)

12.50 in/wc 12.50 po/c.e. (3.11 kPa )
13.90 in/wc 13.90 po/c.e. (3.46 kPa )
11.00 in/wc 11.00 po/c.e. (2.74 kPa )
FRONT: LCx2 REAR:
Max: 54,900.00 (16.09) Min: 46,200.00 (13.54)

Electrical rating / Normes electriques du ventilateur :115V, 60hz, 1.5 A This appliance equipped for altitudes0 – 4500 ft. (0 – 1371.6 m) / Cet unité est conçu pour des altitudes variant entre 0 – 4500 pieds (0 – 1371.6 m). In Canada, also certified for installation in a bedroom or a bedsitting room/ Aussi certfié pour installation dans une chambre à coucher ou une salle de séjour. This appliance must be installed in accordance with local codes, if any; if none, follow the current CAN/CGA-B149 (Canada), or ANSI Z223.1 (USA) Installation Codes. Installer l’appareil selon les codes ou règlements locaux, ou, en l’absence de tels règlements, selon les codes d’installation CAN/CGA-B149 (Canada), or ANSI Z223.1 (USA) en vigeur.
FOR OUTDOOR USE ONLY / POUR USAGE EXTÉRIEUR SEULEMENT
WARNING: Do not store or use gasoline or other flammable vapors or liquids in the vicinity of this or any other appliance. An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance. AVERTISSEMENT : Ne stockez pas ou utilisez l’essence ou d’autres vapeurs inflammables ou des liquides aux alentours de ceci ou un autre appareil. Un cylindre LP non connecté pour l’utilisation ne sera pas stocké aux alentours de ceci ou un autre appareil.

FOR USE WITH THE GLASS CERTIFIED WITH THE APPLIANCE ONLY/ POUR UTILISATION UNIQUEMENT AVEC LES PORTES IN VERRE CERTIFIÉES AVEC L’APPAREIL

MINIMUM CLEARANCES TO COMBUSTIBLES / CLAIRANCES MINIMALES AVEC LES COMBUSTIBLE Left and Right side are determined when facing the front of the appliance. / Les côtés droit et gauche se déterminent en se mettant devant l’appareil et en lui faisant face.

Hearth In Front
Objects In Front Vent Pipe / Déchargez le Tuyau Sidewall to Appliance / Du mur latéral a l’appareil

0.00 in./0.00 po (0 mm)
36.00 in./36.00 po (914 mm) 1.75 in./1.75 po (44 mm) 4.00 in./4.00 po (102 mm)

Pacific Energy Fireplace Products Ltd. Duncan, British Columbia
Canada

Top, Back and Side Standoffs / Sommet, Arrière et Côté Butée Mantel to Appliance / Du manteau al’appareil Maximum Mantel Extension / Allongement maximum du manteau
*See Installation Manual for more detail / Voyez des Directive de l’Installation pour plus détaux. Mantel Supports / Supports du manteau

0.00 in./0.00 po (0 mm) 9.00 in./9.00 po (229 mm) 12.00 in./12.00 po (305 mm)
2.00 in./2.00 po (51 mm)

WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information, consult a qualified installer, service agency or the gas supplier. AVERTISSEMENT: Une installation, un réglage, une modification, une, reparation ou un entretien mal effectué peut causer des dommages matériels ou des blessures. Voir la notice de l’utilisateur qui accompgne l’appareil. Pour de l’aide ou des renseignements supplémentaires, consultez un installateur, un technicien agréé ou le fournisseur de gaz.

P.4.1-15 Efficiency: NG: 26.3% LP: 26.3%
DATE OF MANUFACTURE
03/2021

22032021

100005077-50

100005095

34

TCWS.54OD W SCREEN_181121-20

TCWS.54OD W SCREEN_181121-20

35

100005095

© 2019 Copyright Pacific Energy Fireplace Products LTD Reproduction, adaptation, or translation without prior written permission is prohibited, except as allowed under the copyright laws.
For Technical Support, please contact your retailer. www.townandcountryfireplaces.net 2975 Allenby Rd., Duncan, BC V9L 6V8
Printed in Canada