Xunzel XJ – PureInverter Series Advanced Pure Sine Wave Inverters User Manual
- June 12, 2024
- XUNZEL
Table of Contents
XJ | XJTS | XJC SERIES
User Manual
XJ – PureInverter Series Advanced Pure Sine Wave Inverters
XJ – PureInverter Series
XJ-400W-12V HANDY
XJ-500W-24V | XJ-600W-12V | XJ-1000W-12V
XJ-1000W-24V | XJ-2000W-12V | XJ-2000W-24V
XJC – PureInverter + Charger Series
XJC-1000W-12V-40A | XJC-2000W-12V-55A
XJTS – PureInverter Transfer Switch
XJTS-3000W-12V | XJTS-3000W-24V © Copyright XUNZEL
IMPORTANT INFORMATION. READ. KEEP
-
WARNING! ELECTRIC SHOCK HAZARD
– Connections and safety features must be executed according to the locally applicable regulations.
– Ensure that the equipment is used under the correct ambient conditions. The unit must be used and stored in an indoor area away from direct sunlight, moisture, dusty environment, heat, freezing temperatures or conductive contaminant. Ensure there is adequate free space for ventilation around the product and check that the ventilation vents are not blocked.
– The product has no internal user-serviceable components. Never open the housing as high voltages may be present inside! -
WARNING! FIRE HAZARD
– Use DC-cables with an appropriate size. Place a fuse in the positive wiring nearby battery (P.29).
– Consult battery information to ascertain that it is intended for use in conjunction with the unit.
Always comply with the battery safety instructions.
– If positive and negative wires on the DC input are exchanged, the unit will be damaged. Damage of this kind is not covered by warranty. -
WARNING! Do not connect the AC-output of the unit to an incoming AC source. Do not use the unit with life support systems or any other medical equipment or devices.
-
SAFETY CLASS I. This is a Safety Class I product (supplied with a protective grounding terminal).
Operation of the unit without proper grounding may lead to hazardous situations! Comply with local grounding requirements and regulations. -
SAFETY EQUIPMENT. This product should be installed by a qualified electrician. Ensure that safety equipment is used.
-
KEEP AWAY FROM CHILDREN AND ANIMALS. Electrical devices are not children’s toys. Always keep and use the device out of the reach of children and animals.
-
EMC INFORMATION. This equipment has been tested and found to comply with the limits for CE EMCstandard.
-
BATTERY BANK. The use of XUNZEL deep cycle battery is highly recommended when using the unit.
-
ELECTRIC SHOCK HAZARD. The unit ‘On/Off’ switch does not disconnect the DC power from the battery. Use a DC Disconnect Switch or disconnect the DC input cables before working on any circuit connected to the unit. Failure to follow these instructions can result in death or serious injury.
-
AC LOAD ON POWER INVERTER. Although the unit can provide high surge power, some high surge loads like sump-pumps, heavy duty motors etc. may still trigger the inverter protection system even though the load falls within the power rating of the inverter. A higher power Inverter is required for these appliances.
WARRANTY
RESPONSIBILITY
Under no circumstances will XUNZEL assume any responsability derived from:
- Damages that occur due to force majeure.
- Faulty assembly or connection.
- Damage to the product resulting from mechanical influences and excess voltage.
- Alterations to the product without express permission from the manufacturer.
- Use for purposes other than those described in the operating manual.
- Possible errors in the manuals and the results thereof.
- Reverse polarity in DC input wiring.
- Use of battery bank with lower capacity than recommended.
- Use of battery bank with incorrect nominal voltage.
- Use of smaller cable section or longer cable length.
- Connecting the AC-output of the unit to an incoming AC source.
NOTE: Specifications and functionalities of the unit are subject to
change without notices.
Copyright © XUNZEL. All rights reserved. Production, transfer, distribution,
storage, publication or use of part of all the contents (artwork, designs,
pictures, …) in this document without prior written permission of XUNZEL is
prohibited.
DESCRIPTION
- POWER ON/OFF
- DC INPUT – BATTERY NEGATIVE (-)
- DC INPUT – BATTERY POSTITIVE (+)
- AC OUTPUT ES SALIDA CA
- GROUNDING TERMINAL
- FANS
- USB
- LED INDICATORS
- LCD DISPLAY
- DETACHABLE DISPLAY
- REMOTE PORT
- REMOTE™ PORT
- AC INPUT
Serial Number: —
Conformity
LVD Directive 2014/35/EU
EMC Directive 2014/30/EU
RoHS Directive 2011/65/EU| | XUNZEL ENERGY S.L.
ES-B-20961561
Igartualdea, 57
ES-20850 Mendaro (Spain)
T: +34 943 531 681
info@xunzel.com |
www.xunzel.com
© Copyright XUNZEL | XU-2203004-PMA
---|---|---
**** WEEE 2012/19/EC
Reg. 4790-RII-AEE
2004/12/EC
Ref. 20457