Rasonic RPD-YL13U Compressor Dehumidifier Instruction Manual

June 12, 2024
Rasonic

Rasonic-logo

Rasonic RPD-YL13U Compressor Dehumidifier

Rasonic-RPD-YL13U-Compressor-Dehumidifier-product-img

Safety Precautions

  • Do not operate the unit before carefully reading this instruction guide.
  • Please keep this manual for product warranty and future reference.
  1. Failure or negligence in observing these safety precautions could cause fire, electric shock, or personal injury.

  2. Please be sure your electricity is correct.

  3. Use an independent socket for the appliance. Do not use extension cords to avoid overload and the risk of fire and electric shock.

  4. Please do not place the device near a window or in the bathroom to prevent of electrical shock.

  5. Please ensure the unit is not placed close to the high-temperature appliance to prevent of plastic destruction and fire. 6) Never operate this unit in an explosive, corrosive, or dusty atmosphere to avoid
    hazards.Rasonic-RPD-YL13U-Compressor-Dehumidifier-
fig-1

  6. Always guide if children operate. Never disassemble the unit to avoid hazard, if noise, odor, and abnormal sound are found, please call Shun Hing Electric Service Centre Ltd. to check and repair the dehumidifier.

  7. Operate this unit on a stable surface to avoid vibration and noise.

  8. If toppled over, please pull out the plug at once.

  9. Make sure outlet ventilation is not blocked at all times.Rasonic-RPD-YL13U-Compressor-Dehumidifier-fig-2

  10. Ensure air intake and air outlet ventilation are not blocked at all times. Ensure there is 30 cm of clear space on all sides of the unit. Do not operate the appliance in narrow spaces such as wardrobes or cabinets. Poor ventilation may result in heat and fire.

  11. Do not spray water on the unit, spraying water may cause malfunctioning and electric shock.

  12. Never pull the socket by using damp hands, otherwise, it may cause an electric shock.Rasonic-RPD-YL13U-Compressor-Dehumidifier-fig-4

  13. Always switch off the appliance before unplugging it to avoid electric shock or other hazards.

  14. Switch off and unplug the unit, empty and clean the water reservoir when not using the unit for a long time.

  15. Do not pull the power cord by force because it will cause damage to the power cord.

  16. Never put fingers or other objects in any openings of the unit to avoid injury and product damage.

  17. You must pay attention when moving the unit, empty the tank and unplug the appliance before moving.

  18. This appliance can be used by children aged 8 years and above and persons with reduced physical, sensory, or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.

  19. This appliance is not intended for use by persons (including children) with reduced physical, sensory, or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning the use of the appliance by a person responsible for their safety.

  20. If the supply cord is damaged, it must be replaced by Shun Hing Electric Service Centre Ltd. in order to avoid a hazard.

  21. Check the appliance carefully before ideal for a long time.

  22. Do not exceed the rating of the power outlet or extension cord or connection device. Otherwise, it may cause electric shock or fire due to excess heat generation.

  23. You should never try to take apart or repair the unit by yourself. It may cause the failure of the machine or an electric shock.

  24. Before cleaning, turn off the power and unplug the unit. It may cause electric shock or injury.

  25. Do not drink or use the water drained from the unit. It contains contaminants and could make you sick.

  26. Do not take the water bucket out during operation. It may trigger the bucket’s full protection of the unit and cause electric shock.

  27. Place the unit on a level, a sturdy section of the floor. If the unit falls over, it may cause water to spill and damage belongings, or cause electrical shock or fire.

  28. Do not cover the intake or exhaust openings with clothes, towels, or other objects. A lack of airflow can lead to overheating and fire.

  29. Care should be taken when using the unit in a room with the following persons: Infants, children, elderly people, and people not sensitive to humidity.

  30. Do not use in areas where chemicals are handled. This will cause the unit deterioration due to chemicals and solvents dissolved in the air.

  31. Do not place heavy objects on the power cord and take care so that the cord is not compressed. There is a danger of fire or electric shock.

  32. Do not place flower vases or another water container on top of the unit. Water may spill inside the unit, causing insulation failure and electrical shock or fire.

  33. Always insert the filters securely. Clean the filter once every two weeks. Operation without filters and dust clogs may cause failure.

  34. If water enters the unit, turn off the unit and disconnect the power, otherwise, it may cause failure of the appliance or an accident.

  35. Do not climb up on or sit on the unit. You may be injured if you fall or if the unit falls over.

  36. Be sure the unit is properly grounded to minimize shock and fire hazards.

  37. The dehumidifier must not be left unattended while it is connected to the supply main. Unplug when the appliance is not in use.

Operating Condition

  1. Working condition:
    Ambient temperature: 5c- 35c
    Ambient humidity: 30%RH–90%RH

  2. This device is only for indoor use e.g.: living room, bedroom, office, etc. Never use it in the outdoors.

  3. For the best efficiency and energy saving, make sure the door and window are closed before switching on the unit.

  4. Ensure that the unit is placed on a stable and flat floor surface to prevent excessive vibration and noise. If the appliance tilts, it may cause water overfill and machine overturn.

  5. Never place the unit under the dripping clothes.

Rasonic-RPD-YL13U-Compressor-Dehumidifier-fig-7

Product Structure

Rasonic-RPD-YL13U-Compressor-Dehumidifier-fig-8 Rasonic-RPD-YL13U-Compressor-Dehumidifier-fig-9

Operating Introduction

Control Panel

Rasonic-RPD-YL13U-Compressor-Dehumidifier-fig-10

Functions & Name of Key Pads

  1. ON/OFF: Switch on/off the power
  2. TIMER: Turn off hours settings
  3. HUMIDITY: Press the button to set up humidity ranges of performance (40%/50%/60%/CONT [Continuous Drainage])
  4. SPEED: Press the button to set the airspeed (Low/High)
  5. WATER FULL: Water tank full indication
  6. DEFROST: Defrost indication – the machine will stop dehumidifying and operate defrosting mode

Operation of Key Pads

  • 【On/Off】 button : When a user plugs the device into a power socket, all indicator lights in the control panel will dim after 1 second.
  • On: Press 【On/Off】button to turn on the unit, The machine work at continue dehumidifying, the louver will open manually, the power indicator light and function indicator light up, the fan at high speed running, the compressor resume operation after 3 minutes.
  • Off: When the machine is working, press the 【On/Off 】button again to turn off the unit, 1 beep signal from the buzzer can be heard at the same time.

【TIMER】button

  • Press 【Timer】 to set the operating time for 2H/4H/6H, and the timer indicator lights up.

【HUMIDITY】button

Press the 【HUMIDITY】 button to set desired humidity 40%→50%→60%→ CONT →40%→ …… Set the 40%— expectation of ambient humidity value is 40%, when the appliance detects that the current ambient humidity is less than or equal to 38%RH, the compressor stops working, the appliance starts and the fan runs at low speed; when the appliance detects that the current ambient humidity is more than or equal to 42%RH, the compressor will work and the fan starts to run in setting speed. It is similar to another humidity for 50% / 60%.

【SPEED】button

  • Press 【SPEED】 button to select the fan working at the “High speed” level or “Low speed” level. Meanwhile, the high or low-speed indicator light is illuminating.

WATER FULL

  • When the tank is full, the compressor and fan will automatically shut off and the buzzer will alarm. Meanwhile, the indicator lights of “power” and “tank full” will illuminate.

Memory function

  • Press the 【ON/OFF】 button to switch off the unit and the device is on standby, the device will memorize the last setting if the user turns it on again.
    Notice: Timer is not applicable in memory function.

  • When power resumes after a power failure or electricity suspension, the machine cannot restart automatically and there is no memory function.

Automatic Defrosting

When the machine is working in low temperatures, in order to protect the cooling system, the automatic defrosting function will be activated. When the sensor detects the temperature of the evaporator lower or equal to -1℃, the compressor will be continuously running for 30 minutes, then stop, the machine start defrosting, and the 【Defrost】 icon lighten. When the sensor detects the temperature of the evaporator higher or equal to 2℃ and the defrost time longer or equal to 10 minutes, the auto-defrost mode end and the compressor start to work, the machine began to dehumidify, the 【Defrost】 icon light off.

Water tank full automatic stop function

When the device is set to operate in dehumidification mode, and the water level in the water tank reaches the preset height, the buzzer will alarm and the machine will stop. Take out the water tank and empty the water, and then reinstall the water tank, the device will resume the operation which is set before the water tank is full. (The device will resume operation after the water tank is put back for 3 minutes.)

Note: This function is only available when the dehumidification operation is ON.
WARNING: If the water tank is full of dirty water or foreign objects, the buoys may not float normally as the water level in the water tank rises. This may cause the water tank to overflow and cause the water to flow to the floor. Please clean the tank and buoy in time.

Compressor protection function
When the device is set in the dehumidification operation, and the compressor stops working if it is restarted immediately, the cooling system pressure is not balanced, this may lead to compressor protection function—that is, the compressor will delay 3 minutes to restart. Within 3 minutes, the machine stops dehumidification.

Continuous Drainage
When the machine needs to be drained continuously, connect the drainage hose of 15mm inner diameter to the drain outlet on the rear shell through the drain nozzle. The machine will run continuously and the water tank will not be filled with water. At this point, Water Tank Full Automatic Stop Function will not work. When draining continuously, the drainage hose should be laid flat on the ground without folding or upturning. Otherwise, drainage may not be even or not drained.

Cleaning and Maintenance

Cautions: Make sure the unit is switched off before cleaning.

  1. Clean the Grille and Case
    • Use water and a mild detergent. Do not use poisonous or corrosive detergent.
    • Do not splash water directly onto the main unit. Doing so may cause an electrical shock, the insulation to deteriorate or rust.
    • The air intake and outlet grilles get soiled easily, so use a vacuum cleaner or brush to clean them.
  2. Clean the bucket
    • Clean the bucket to prevent the growth of mold, mildew, and bacteria every few weeks.
    • Partially fill the bucket with clean water and add a little mild detergent. Swish it around in the bucket, empty it, and rinse it.
  3. Clean the air filter
    • The air filter behind the front grille should be checked and cleaned at least every 30 days or more often if necessary.
    • Remove Procedure: Grip the tab on the filter and pull it outward.
    • Reinstall Procedure: Aim 2 pcs tabs at the bottom of the filter to the machine’s tabs, then press the 2 pcs tabs at the top of the filter.

Troubleshooting

Before calling for service, please review the chart below.

Problems Checklist
Dehumidifier does not start  Make sure the power plug is pushed completely

into the outlet.

Check the fuse/circuit breaker box.

Dehumidifier has reached its pre-set level or the bucket is full.

The water bucket is not in the proper position.

Poor performance of dehumidifying|   Did not allow enough time to remove the moisture.

Make sure there are no curtains, blinds, or furniture blocking the front or back of the dehumidifier.

The ambient humidity may be lower than the humidity setting.

Check that all doors, windows, and other openings are securely closed.

Room temperature is too low, below 5C (41F).

There is a kerosene heater or something giving off water vapor in the room.

Noise during operating|  The air filter is clogged.

The unit is tilted instead of upright as it should be.

The floor surface is not level.

Frost appears on the coil|  This is normal. The dehumidifier has an auto- defrost feature.
Water leakage|  The hose to the connector or hose connection may be loose.

I intend to use the bucket to collect water, but the back drain plug is removed.

Power indicator and defrost indicator lights flashing

|  PCB board temperature sensor may be short-circuited.

Environment temperature ≦0℃或≧

40℃

No connection with the PCB board

If the error repeats, please contact Shun Hing Electric Service Centre Ltd.

---|---
Defrost indicator light flashing|  Defrost temperature sensor may be short- circuited

Evaporator temperature keep lasting ≧40℃

If an error remains, please contact Shun Hing Electric Service Centre Ltd.

All indicator lights flashing| Refrigerant leak

If an error remains, please contact Shun Hing Electric Service Centre Ltd.

If the above solutions cannot fix the problem, stop using them immediately and contact Shun Hing Electric Service Centre Ltd to check and repair them.

Special Avowal

  1. The information above has been checked. Our company reserves the hermeneutic power to any printing errors or misunderstandings in the content.
  2. If there are technical improvements on the appliance, the operation manual will be updated without any prior notice. The product appearance and color are subject to the actual appliance.
  3. An electronic copy of the user manual can be emailed to the customer. If necessary, please call Shun Hing Electric Works & Engineering Co., Ltd.: 28612767.

After Sales Service

For any defect, in the judgment of the technician from Shun Hing Electric Service Centre Limited, caused under normal use, we are responsible for repairing or replacing parts of the said electrical appliance free of charge within one year guarantee period commencing from the date of purchase. Any defective part which has been replaced shall become our property. Guarantee service does not cover the repair or replacement of accessories, external cables or cabinets, etc. Additional charges shall be levied if services are required. Please present the official invoice and the guarantee certificate with the sales point’s chop or the redemption center’s chop for free maintenance. For inquiries, please call Shun Hing Electric Service Centre Limited hotline at 2406 5666. Free guarantee service will not be provided to the unit if: 1) it has been explicitly or implicitly modified, tampered with, altered, or repaired in any way by persons other than technicians of the Company. Or 2) it has been damaged through misuse, negligence, liquid ingress or corrosion, power interruption, natural calamities or accident, or external factors. Or 3) it is not a fixed installation on land. Or 4) the normal operation of the unit is affected by improper installation. Or 5) the domestic model of the unit is used for industrial or commercial purposes. Or 6) the change of location or ownership of the unit and not inform Shun Hing Electric Service Centre Limited.

Product Specification

Model RPD-YL13U
Rated voltage 220-240V ~ 50Hz
Dehumidifying capacity 7L /day    (26.7C 60%RH)

13L /day    (30C 80%RH)

Power consumption| 155W         (26.7C 60%RH)
Refrigerant| R134a / 95g
Water tank capability| 2L
Dimension ( W X D X H )| 290mm x 240mm x 476 mm

SHUN HING ELECTRIC WORKS & ENGINEERING CO., LTD

MAINTENANCE AND REPAIR SERVICE

  • SHUN HING ELECTRIC SERVICE CENTRE LTD

  • OFFICE: 11TH FLOOR, SHUN HING CENTRE, 2 SHING YIU STREET, KWAI CHUNG, NEW
    TERRITORIES, HONG KONG

  • TEL: (852) 2406 5666

  • FAX: (852) 2408 0316

  • WEBSITE: www.shesc.com.

CONSUMABLES/ ACCESSORIES SALES HOTLINE

  • TEL: (852) 2406 5666

CUSTOMER SERVICE CENTRES

  • 1ST FLOOR, SHUN HING CENTRE, 2 SHING YIU STREET, KWAI CHUNG, NEW TERRITORIES, HONG KONG
  • TEL: (852) 2406 5439
  • FAX: (852) 2408 1389
  • AVENIDA DE VENCESLAU DE MORAIS, NO. 193-199, 5 ANDAR-I, EDF. INDUSTRIAL NAM LENG, MACAU
  • TEL: (853) 2836 2928
  • FAX: (853) 2833 6405
  • www.shesc.com.
  • For the latest information on customer service centers, please visit www.shesc.com or call us at our hotline.

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals