IMPORTANT WARNING!
Read the safety features and the user manual carefully before installing and connecting the device to power.

SAFETY FEATURES

The following safety features must be observed during device’s use, operation and maintenance. This device can be operated by children from the age of 8 and by persons with reduced physical, sensorial or mental abilities or the lack of experience and knowledge only if they are under the supervision or have been informed about a safe use of the device and have understood the possible hazards. Children mustn’t play with the device. Children mustn’t clean or maintain it without supervision. Operating personnel must be informed about the nature and impact of the ultraviolet radiation UV-C on the human organism. Failure to comply with the safety features in this manual may cause physical injury or serious damage of the device, its parts or accessories.

The device contains UV-C discharge lamps.

UV-C radiation is dangerous for eyes and skin. Do not use UV-C discharge lamps outside of the device.

Do not use the device in explosive environment

Do not power up the device in the environment with flammable gases and smokes. Do not use any electronic devices in such environment due to the possible danger of explosion.

Water, humidity and heat

Do not use the device near water or in a high-humidity atmosphere, where condensation of water may occur inside the device. Do not expose the device to rain. It can cause an electric shock or a fire! Never install the device near a source of heat or hot air. During installation ensure that there is an access of air to the device and the ventilation openi gs are not covered.

Powering up the device

To power up the device, use the original power cable. Wait for at least 10 minutes after unpacking until the device’s temperature adjusts to the temperature of the environment. The purifier is protected with safety class I. with IP20 protection against the dangerous contact with electronic current.

KEY FEATURES

  • Destroys microorganisms such as bacteria, fungi, yeasts and viruses, including the CORONAVIRUS!
  • Closed-type device suitable for public places with frequent movement of persons.
  • Incredibly low noise due to its special fans.
  • Safety pin that automatically turns off the device when the cover is opened.
  • LED status and UV discharge lamp lifetime indication.
  • Multi-functional mounting: wall-mount or desktop use.
  • The device is designed to disinfect the air during the presence of human beings. UV-C radiation purifies the air in a special tunnel inside the device. Shielding at the device’s input and output prevents from UV radiation leakage. The device does not cause any harm to the present persons.
  • The device is designed and made in Slovakia

Air disinfection – use

The Air Purifier is designed for disinfection of interiors such as hospitals, doctors’ and vets’ practices, cleaning rooms, offices with or without AC units, food processing factories, storage rooms and public places with frequent movement of persons. The disinfection is achieved by forced air circulation through the chamber with UV discharge lamps. The device is designed the way that the radiation does not get out of the discharge lamp chamber. So-called germicidal radiation, that is ultraviolet radiation of the UV-C spectrum with a wavelength below 320 nm, is used for disinfection. Air disinfection is accomplished by performing this spectrum on microorganisms that are present in the air. It is used everywhere, where the disinfection of the environment using ordinary methods is not possible.
Air disinfection

Air purifier installation

During the purifier installation, consider natural air circulation in the room and place it the way that there are no barriers around, which would block getting sufficient amount of air circulation. The purifier can be installed on the wall with two screws introduced through holes on the rear side. Second option is an installation on the stand with four supplied screws. In this case, you can easily place the purifier on any flat surface. For the stand installation, a PH1 screwdriver is needed.
Air purifier installation

Microprocessor control unit description

Air purifier is equipped with a microprocessor control unit, which manages correct operation of the whole device, air circulation and calculates runtime of the discharge lamps. On the side, there are OK and SERVICE LED indicators, RESET button and the main switch. After turning on the main switch, fans will start running and the green OK LED indicator will light up. This means that the device is working correctly. Red SERVICE LED indicator will start flashing 500 hours before the discharge lamp lifetime ends. After the lifetime ends, the red LED will be on permanently.
Microprocessor control unit description

Maintenance

Air purifier requires regular maintenance. Remove the dust or other dirt using a nonaggressive cleaning aid. For correct functioning of the emitter it is necessary to keep the UV discharge lamp clean and monitor its lifetime. In case of a visible contamination located at the vents, it is necessary to clean the device thoroughly. If the switching of Air purifier by a programmable timer with an operating hours counter is not ensured, it is necessary to ensure the recording of operation so that it is possible to determine the status of the UV-C source at any time. In case of any doubts, it is necessary to verify its effectiveness by measuring the intensity of UV radiation. For more information about the device maintenance, please visit our website www.srsmedilux.com.

Replacing the UV discharge lamp

You need to replace the UV discharge lamps after their lifetime has ended. Even though they seem to light with the same colour, the intensity of the ultraviolet UV-C element is significantly lower.
Only a qualified person may open the device after disconnecting it from the power source. Unscrew the top cover and remove it.
WARNING: There is a danger of burning since the UV discharge lamps may be hot!
Allow them sufficient time to cool down.
Eject the discharge lamp from its base and remove it from the holder. Install new discharge lamps in the reverse order mentioned before. We recommend original OSRAM lamps of type HNS – see specification in the technical specifications section. When closing the device, ensure that the cover fits the device’s body and there is no gap that could cause UV radiation leakage. The counter must be reset after the replacement. Turn on the main switch and hold the reset button pressed for at least 5 seconds using a thin object. The GREEN SERVICE LED will turn on. Malfunctioning or broken tubes must be disposed as electronic waste.

Prevention from harmful effects of the UV-C radiation

UV-C radiation has harmful effect on a human organism depending on the intensity and the time of exposure. When it comes to the contact with eye, radiation can cause conjunctivitis. UV-C radiation is aggressive and harmful for humans, animals and plants.

PURITEC® HNS® discharge lamp description

OSRAM PURITEC® HNS® are low-pressure discharge lamps, which emit short-wave ultraviolet radiation. They are very environmentally friendly and they are a great alternative to chemical cleaners. Their radiation effectively destroys cells and is perfect for high effective cleaning of water, air and surfaces while eliminating the necessity to use chemical cleaners.
Operational principle of an UV-C discharge lamp:

UV-C radiation has photolytic effect on the DNA of microorganisms like bacteria, moulds, yeasts and viruses causing them to be incapable to replicate.

Cleaning effect is achieved by light at a wavelength under 320 nm, with optimal effect at 260 nm. HNS germicidal discharge lamps emit UV light at a wavelength of 254 nm and are ozone free.
HNS® discharge lamps do not generate ozone:

Main lines of the mercury discharge spectrum appear at 254 nm and 185 nm. Ultraviolet light at a lower wavelength below 240 nm creates ozone. Discharge lamp housing is made of fused quartz, which eliminates radiation below 240 nm. The discharge lamp emits radiation, which destroys microorganisms, but does not leak radiation that generates ozone.

Functions

General elimination of bacteria
Deactivation of escherichia coli

Relative effect
Diagram

Spectral power distribution of ozone-free lamps

Relative spectral radiant power
Diagram

Decrease In UVC radiation for the HNS L 24 W 2G11

UVC radiant power in %
Diagram

Switching cycle 165 minutes on, 15 minutes off. burning time in hours

The lamps have a maximum life of 18,000 hours. To maximize the effectiveness of killing viruses and bacteria, we recommend replacing the lamps after 9,000 hours. The device signals the need to replace the lamp.

Technical specifications

Type: SRSmedilux PMX2A48

Product coder: 9600XX

Operation

  • Voltage: AC 220 – 240 V
  • Frequency: 50 / 60 Hz
  • Current: 0.25 A

Protection: IP20

Operating environment according to STN 33 2000-5-51 (IEC 60364-5-51): AB5

  • inner environmenttemperature: 5– 40 ºC
  • absolute humidity: 1– 25 g/m3
  • relative humidit: 5 – 85 %

Airflow: 57 m3/hr
Noise level: < 20 dB
Dimensions: 600 x 150 x 70 m

Colour variants

  • white– PMX2A48
  • black– PMX2A48–B
  • different colour finish– PMX2A48–CC

Weight: 4.4 kg
Input power: 58 W

UV-C radiation supply

2x OSRAM HNS L 24 W 2G11 or UV compatible discharge lamp (2x PHILIPS TUV PL-L 24W/4P 1CT/25).

Pictogram explanation

**** General warning: Warns the user about the presence of important operational and maintenance instructions in the documentation attached to the device.

**** Dangerous voltage: Warns the user about the presence of non-isolated dangerous voltage inside the device, which can cause electric shock.

**** Warning: UV-C radiation is the strongest UV radiation – its wavelength is below 280 nm. The UV-C radiation penetrates deeply into the fibre and it is harmful for living organisms.

Crossed dust bin symbol means that the product or its components cannot be disposed as domestic waste. They must be disposed as electronic waste.

USER WARNING

During operation with the device, it is necessary to comply with the STN 343108- 68 regulations, which contain safety regulations about the handling of the electronic equipment by persons without electro-technical qualification – see more in the regulation No. 508/2009 of the Collection of Law of the Slovak Republic.

Never use a defective device (e.g. with a defective power cable).

Before any interference with the device or the device maintenance, it is necessary to disconnect the device from the power supply.

The device can be plugged only to a correctly installed electrical system with correct fusing that complies with lawful regulations and norms. It is dangerous to modify the device in any way

Failure to comply with the listed warnings can cause electric shock or damage of the device!

Classification of the PURITEC® HNS® discharge lamps according to IEC / EN 62471 (photo-biological hazard): hazard group 3

PURITEC® HNS® discharge lamp radiation poses a health risk. It can cause conjunctivitis and erythema (sun burn) after a short exposure. Skin and eyes must be protected against direct discharge lamp radiation!

UV-C discharge lamps cannot be used for general lighting!

The manufacturer reserves the right to make design changes to the device without changing the overall character.

SRSmedilux, Rybnicna 36/D, 83107 Bratislava, Slovakia
sales@SRSmedilux.com www.SRSmedilux.com +421232661800