LINEAR AM-SEK Ethernet Module
Product Information
- Product Name: AM-SEK Ethernet Module
- Part Number: 231625 Rev-D
- Ink: Black
- Paper Stock: 20# Mead Bond
- Size: Flat 17.000 x 11.000
- Folding: 1-Fold Vertical to 8.500 x 11, Fold Horiz 5.500 x 8.500
Product Usage Instructions
Local Connecting with AccessBase2000
- Open the AccessBase2000 application.
- Go to the network settings screen.
- Set each active network to connect using the virtual COM port number (COM2 – COM8) that was set up to communicate with the AM-SEK module.
Local Connecting with AXNET
- Create a Windows direct connect network for AXNET communications.
- Select the virtual COM port number assigned to the AM-SEK module for the Communications Cable Between Two Computers setting.
- Configure the port speed to 38400 bps.
Remote Connecting with AccessBase2000
- Open the AccessBase2000 application.
- Go to the network settings screen.
- Set each active network to connect using the virtual COM port number (COM2 – COM8) that was set up to communicate with the router’s external IP address and module’s public port number.
- NOTE: In existing installations, it is not recommended to connect with AccessBase2000 remotely on a separate setup PC. Always backup installation data to avoid loss of cardholder data and other programming.
Remote Connecting with AXNET
- Create a Windows direct connect network for AXNET communications.
- Select the virtual COM port number that was set up to communicate with the router’s external IP address and module’s public port number.
- Configure the port speed to 38400 bps.
- After the network connection is made and connected, use an Internet Web browser to connect to the AXNET panel.
Communicating with the Access Network
Local Connecting with AccessBase2000
After opening the AccessBase2000 application, go to the network settings
screen and set each active network to connect using the virtual COM port
number (COM2 – COM8) that was setup to communicate with its AM-SEK module.
Local Connecting with AXNET
Create a Windows direct connect network when setting up for AXNET
communications. Be sure to select the virtual COM port number assigned to the
AM-SEK module for the “Communications Cable Between Two Computers” setting. Be
sure to configure the port speed to 38400 bps.
Remote Connecting with AccessBase2000
After opening the AccessBase2000 application, go to the network settings
screen and set each active network to connect using the virtual COM port
number (COM2 – COM8) that was setup to communicate with the router’s external
IP address and module’s public port number.
NOTE: In existing installations, it is not recommended to connect with AccessBase2000 remotely on a separate setup PC. The installation’s database in the local PC could get overwritten, causing LOSS OF ALL CARDHOLDER DATA and other programming! Always backup installation data!
Remote Connecting with AXNET
Create a Windows direct connect network when setting up for AXNET
communications. Be sure to select the virtual COM port number that was setup
to communicate with the router’s external IP address and module’s public port
number. Be sure to configure the port speed to 38400 bps. After the network
connection is made and connected, use an Internet Web browser to connect to
the AXNET panel.
AM-SEK General Specifications
Note : AM-SEK Module is only available in the AM-SEK Kit and is not sold separately.
- Power: 12 VDC from plug-in power supply (included), also supports a 5 volt DC redundant input from an external power supply
- Network Connection: 100BASE-T RJ-45 connector
- Network Speed: Fast Ethernet 10/100 Mbps
- Serial Connection: Male DB9 for connection with A2C/DB9 serial cable (included)
- Serial Port Speed: 38.4 Kbps
- Mounting: DIN-rail or screw mounting
- Dimensions (AM‑SEK Module): 3-1/2” W x 3-3/4” H x 1” D Weight: 6-1/2 oz.
- AM-SEK Utilities are available for download at linear-solutions.com/product/serial-to-ethernet-adapter-kit/
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Using Ping to Test IP Addresses
- From the Windows START menu, select RUN.
- Enter COMMAND (or CMD) into the OPEN: field and press OK. The DOS command prompt window will open.
- To test an IP address enter PING and the IP address.
- If the Ping command displays “Request timed out.” the IP address is not currently used. The address can be assigned to a AM-SEK module.
- If the Ping command displays replies from the IP address, the address is already being used by a device and cannot be assigned to a AM-SEK module.
AM-SEK Kit Includes
Overview
The AM-SEK Kit includes a AM-SEK Serial-to-Ethernet Module that provides a
standard network TCP/IP connection for Linear’s AM3Plus, AE1000Plus, and
AE2000Plus access controllers. The module can be used as an alternative to a
traditional telephone modem typically used for remote access to Plus panel
controllers.
The AM-SEK module connects between the Plus panel’s RS-232 Serial port and the
installation’s Local Area Network (LAN). Access to the panel can be locally
through the LAN or remotely from the Wide Area Network (WAN). Typically the
module is connected to a port on a router located on the installation’s LAN.
In Plus panel networks, with multiple panels interconnected via RS‑485
wiring, the AM‑SEK module connects to Node #1 of an AXNET network, or Node #1
of any AccessBase2000 network.
The AM-SEK does not replace the RS-485 and modem connections in a multiple
access panel network. It does enable using an Ethernet network connection
(instead of a direct serial connection or modem) between a Windows PC and
supported Linear access panels to access and configure the panels using AXNET
and/or AccessBase2000 applications.
For easy configuration and setup, Windows® based software utilities are can be
downloaded from linear-solutions.com/product/serial-to-ethernet-adapter-kit/.
The utility software is used for setting up the AM-SEK module’s IP address and
the computer’s virtual COM ports. The utility software is compatible with
Windows XP®, Windows Vista® and Windows 7®.
To help with the module and router network configuration, a log sheet is provided to document the installation settings.
Network Issues
Computer network topologies range from simple to complex. These instructions
outline installation for a basic local area network. Large and complex
networks may require setup that is beyond the scope of these instructions. If
setup issues arise while configuring the AM-SEK module, seek assistance from
the IT professional responsible for maintaining the network.
Programming PC Overview
At the installation site, a programming PC needs to be connected to the Local
Area Network. This PC can be a permanent one in the installation, or can be a
temporary PC brought in by the installer.
Administrator access will be required to setup the virtual COM ports on the
PC. The virtual COM ports are assigned the IP address and port number of each
AM-SEK module.
If AccessBase2000 is used to manage the access network, it needs to be
installed on the management PC. To avoid overwriting the installation’s
database, don’t run AccessBase2000 remotely on a separate setup PC.
If AXNET is going to be used to manage the access network, the PC will use a
Windows direct connect network connection to communicate with the access
network. Refer to Page 5 of AXNET manual P/N 226505 for details on setting up
the Windows direct connect network connection.
Module Installation
- Mount the AM-SEK module in a secure and weather protected location.
- Connect the modular jack end of the A2C-DB9 cable to the RS-232 Port of the Linear “Plus” panel.
- Connect the DB9 connector end of the A2C-DB9 cable to the COM port on the AM-SEK module.
- Connect a CAT-5 network cable between the LAN connector on the AM-SEK module and an open port on the Local Area Network’s router (300 foot cable length maximum).
- Route the wire from the power supply and connect the power supply cable RED (+) and BLACK (-) terminals on the plug-in terminal block. Plug the terminal block into the module.
- Repeat Steps 1-5 for each additional AM-SEK module installed for different access networks in the installation.
- When power is applied, a module’s RUN indicator should light and the LAN indicator should flash.
TYPICAL INSTALLATION WITH THE AM-SEK MODULE FUNCTIONING AS THE INTERFACE BETWEEN THE PLUS PANEL AND THE INSTALLATION’S LOCAL AREA NETWORK
General AM-SEK Module Configuration
- From the Windows START menu, select RUN.
- Enter COMMAND (or CMD) into the OPEN: field and press OK. The DOS command prompt window will open.
- Enter IPCONFIG and press ENTER. The current Windows IP configuration for the PC will be displayed. Write down the IP Address, Subnet Mask, and Default Gateway address numbers. Keep the window open for reference or enter EXIT to close it.
-
Download the AM-SEK utilities from linear-solutions.com/product/serial-to-ethernet-adapter-kit/. Once downloaded extract the utilities zip file and and launch the monitor.exe application.
NOTE: The monitor.exe application has several buttons and options that are not used for AM-SEK module setup. -
Press the INVITE button. The application will display a list of all the AM-SEK modules discovered on the network.
NOTE: The monitor.exe application can only detect modules located on the LAN
side of the same router as the PC.
-
From the displayed list, select the IP address of the module to program. (To help to identify modules, checking the LOCATE box will cause the selected module to beep.) Press CONFIG.
-
The configuration for the selected module displays showing the fixed MAC address and currently programmed IP, Gateway and Subset Mask addresses.
-
A static IP address is required for the AM-SEK module. Verify that the AUTO IP box is un- checked.
-
To allow the module to communicate with the PC on the same network, the first three octets (xxx.xxx.xxx) of the AM‑ SEK module’s IP address must to be set to the same as the programming PC’s IP address. Set the first three octets for the module’s addresses into the IP ADDRESS field. To avoid conflicts with existing network devices, choose a high number from 150-254 for the forth octet.
Example: PC = 192.168.242.72 Module = 192.168.242.150
NOTE: The IP address for each AM-SEK module in an installation must be unique and not conflict with other devices on the network. The DOS PING command can be used to check if an IP address is currently used or vacant (see Page 4). -
Set the Gateway and Subnet Mask addresses to the same as the programming PC.
-
Write the settings in the log sheet to document the access network module and note the modules address settings.
-
Enter a name for HOST NAME to identify the module or the access network installation.
-
Press CONFIG NOW to send the configuration to the module.
-
The AM-SEK module should beep and an acknowledge window will display. Press OK.
PC Virtual COM Port Configuration
-
Launch the AMSEKver499.exe installation program. Install the virtual COM port program on to the PC as instructed by the installation wizard.
-
Select the virtual COM port(s) that will be used to connect to the AM-SEK module(s). Press OK.
NOTE: Serial-IP supports virtual COM ports 2-4096. AXNET can connect through any valid COM port. AccessBase2000 can only use ports 2-8. Each module in the installation will need a unique COM port assigned to the module’s IP address. -
In the SERIAL/IP CONTROL PANEL select a COM port to use to connect to a module. Be sure the CONNECT TO SERVER box is checked. Enter the module’s IP address in the IP ADDRESS field. Enter port 4660 into the PORT NUMBER field.
-
Press CONFIGURATION WIZARD. The Configuration window will be displayed. To test the PC’s COM port serial-to-IP connection, press START.
-
The status area will show the progress of the test. Green check marks indicate that the connection is OK. Red check marks indicate failures in the test. If the test fails, verify the address and port settings of both the module and the PC. Be sure the first three octets of the AM-SEK module’s IP address match the PC. Press USE SETTINGS to exit the wizard.
-
Repeat Steps 2 through 5 for any additional AM-SEK modules in the installation.
-
When finished, press CLOSE to exit the SERIAL/IP CONTROL PANEL. (The SERIAL-IP control panel can be restarted at any time from the Windows START menu.)
Setup for Remote Off-Site Access
The AM-SEK module installation and programming is identical for remote off-
site access, the difference is in the router programming and the IP address
used to communicate with the access network.
NOTE: For remote access, the AM-SEK module(s) must be connected to a router that supports a virtual server and has a STATIC external IP address. An Ethernet switch cannot be used.
To be able to reliably connect with the router remotely over time, the router’s external IP address must be a static IP. A dynamic IP address will change over time, which would require changing the virtual COM port setting each session before connecting.
Router Setup
Each AM-SEK module will have a unique IP address and will use private port
number 4660. It’s the “port forwarding” or “virtual server” in the router that
will resolve a public port number to each module’s IP address and private port
number.
When connecting remotely to a module through the router’s virtual server, the
router’s external IP address and module’s public port number are used.
Example address: 71.167.14.130:4001
- 71.167.14.130 is the router’s external IP address
- 4001 is the module’s public port number
NOTE: Although similar, each manufacturer’s router model’s setup screens are different. The “virtual server” may be called another name depending on manufacturer. Some routers do not support public to private port forwarding through a “virtual server”.
The router will need to be setup on-site from a PC connected to the Local Area Network. Following is a typical router setup procedure:
-
On a PC connected to the router, open a browser window.
-
Enter the internal IP address of the router in the address bar of the browser. The router’s login screen should be displayed.
-
Enter the username and password. Unless the router login has been reprogrammed, the typical default username is admin, and the password is blank. Click the OK to log into the router.
NOTE: If you cannot login to the router successfully, consult with the IT personnel at the installation for assistance. -
Virtual server or port forwarding is usually in the Advanced area of the router setup. Refer to the router manufacturer’s documentation.
-
For each AM-SEK module connected to the router, enter the module’s IP address, the module’s private port number (always 4660) and an unused unique public port number. Be sure to setup and enable a virtual server for each module connected.
NOTE: Each public port number chosen for modules must be unique and currently available (unused). -
For “traffic type” select TCP, for “schedule” select always. Terms will vary per router model.
-
Each connection may also be able to be given a name. Enter a descriptive name for the location of each AM-SEK module. This will help to identify the module’s router settings to yourself or others in the future.
- After setting up the router, be sure to select SAVE SETTINGS in the router.
Virtual COM Port Setup for Remote Access
Follow these steps to setup the virtual COM ports for remote access:
- Determine the exterior (WAN) IP address by checking the router’s device information page.
- From the Windows START menu, launch the Serial-IP Control Panel application.
- In the SERIAL/IP CONTROL PANEL select a COM port to use to connect to a module. Be sure the CONNECT TO SERVER box is checked. Enter the router’s external IP address in the IP ADDRESS field. Enter the module’s public port number that was set up for the module in the virtual server into the PORT NUMBER field.
- Press CONFIGURATION WIZARD. The Configuration window will be displayed. To test the PC’s COM port serial-to-IP connection, press START.
- The status area will show the progress of the test. Green check marks indicate that the connection is OK. Red check marks indicate failures in the test. If the test fails, verify the address and port settings. Press USE SETTINGS to exit the wizard.
- Repeat Steps 2 through 5 for any additional AM-SEK modules in the installation.
- When finished, press CLOSE to exit the SERIAL/IP CONTROL PANEL.
Write the settings in the log sheet to document the virtual COM port and virtual server address settings.
Technical support: 800-421-1587 •
M – F 8am – 7pm EST
Sales & Customer Service: 800-543-4283
• M – F 8am – 7pm EST • Website: www.linear-solutions.com
Nortek Security & Control LLC | 5919 Sea Otter Place, Suite 100, Carlsbad, CA 92010 USA
©2021 Nortek Security & Control LLC. All rights reserved. Linear is a registered trademark of Nortek Security & Control LLC.