Linear OSCO GSLG-A-423 Slide Gate Operator Instruction Manual
- June 1, 2024
- Linear OSCO
Table of Contents
Linear OSCO GSLG-A-423 Slide Gate Operator
Product Information
Specifications
- Mounts bolted to posts secured in concrete footings
- Gate must have fabric cover with openings no larger than 2-1/4 inches
- Use two 3 – 3-1/2 OD galvanized posts for mounting
- Designed for gates used for vehicles
- Requires separate pedestrian access opening
Product Usage Instructions
Mounting Pad Installation
The gate operator mounts bolted to posts secured in concrete footings.
Ensure posts support the operator to prevent movement during operation. Refer
to Linear drawing #2700-360 for optional pad mounting instructions.
Gate Preparation
Before installation, ensure the gate rolls or slides freely and that
exposed rollers are covered. The gate must be covered with fabric meeting
specified requirements. Mesh is optional for picket-style gates with certain
spacing.
Mounting Specifications
Use two 3 – 3-1/2 OD galvanized posts and secure with concrete footings as per
guidelines. Attach the operator using provided hardware. Ensure correct
placement of side plates as per illustration.
Drive Chain and Gate Brackets Assembly
Refer to Page 4 for assembling the drive chain and gate brackets. Maintain
proper chain sag and ensure it does not come into contact with moving parts of
the gate or ground.
Warnings
Ensure separate pedestrian access opening is provided. Gate must be
installed with sufficient clearance from adjacent structures to reduce risk of
entrapment.
FAQ
-
Q: Can the gate operator be used for pedestrian gates?
A: No, the operator is intended for installation only on gates used for vehicles. Pedestrians must have a separate access opening. -
Q: How should I ensure safety during installation?
A: Follow all mounting specifications, ensure proper gate preparation, and maintain clearances as per warnings provided in the manual.
Mounting Pad Installation
The gate operator mounts bolted to posts secured in concrete footings. The posts support the operator and prevent it from moving during operation. For optional pad mounting instructions, see Linear drawing #2700-360.
Gate Preparation
Before installing, make sure the gate rolls or slides freely, and that all
exposed rollers are properly covered. The gate must be covered with fabric
with openings no larger than 2-1/4” in size, to a minimum height of 72” above
ground level. On picket-style gates, if pickets are spaced less than 2-1/4”
apart, mesh is optional.
Mounting Specifications
- Use two 3 – 3-1/2” OD galvanized posts and secure with concrete footings as shown, length to be determined by local codes, frost line depth and soil conditions.
- Attach the operator with the U-bolts, side plates and hardware provided. Four 3/16” side plates go on the outside top and bottom, two 1/2” side plates go on the inside top, and two 3/16” side plates go on the inside bottom (see the illustration at right).
- To assemble the drive chain and gate brackets, refer to Page 4. Make sure that the chain sag does not exceed recommended sizes and that the chain does not come into contact with the moving parts of the gate or ground.
WARNING
The operator is intended for installation only on gates used for vehicles.
Pedestrians must be supplied with a separate access opening. The pedestrian
access opening shall be designed to promote pedestrian usage. Locate the gate
such that persons will not come into contact with the vehicular gate during
the entire path of travel of the vehicular gate.
WARNING
The gate must be installed in a location so that enough clearance is supplied
between the gate and adjacent structures when opening and closing to reduce
the risk of entrapment.
COVER GATE WITH FABRIC WITH OPENINGS SMALLER THAN 2 1/4″ TO A MINIMUM HEIGHT OF 72″ ABOVE GROUND. ON PICKET STYLE GATES, IF PICKETS ARE SPACED LESS THAN 2 1/4″ APART MESH IS OPTIONAL.
GSLG-A Slide Gate Operator Installation Guide
P1222 Revision X5 6-22-2011
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>