Airwell XVVA-050 Console Type Indoor Unit User Manual
IMPORTANT NOTE:
Read this manual carefully before installing or operating your new air conditioning unit. Make suretosave this manual for future referenc
Console Type Indoor Unit (new)
Features
**
Compact unit, space saving
The console indoor unit is very slim and will be harmonious with room. It can
be placed at the corner, and it is very space saving.
Dual air sending position
The console indoor unit can send the air from the top and the bottom, which
will realize the indoor temperature be adjusted soon.
Quiet operation
Thanks to the low noise centrifugal fan, the unit always works quietly, it
lets your life more comfortable.
High efficiency filter
The console indoor unit adopts high efficiency filter to improve the air
quality.
Specification
MODEL | XVVA-025N-01M22 |
---|---|
Power supply | Ph-V-Hz |
**** Cooling | Capacity |
Capacity | kW |
Power input | W |
Current | A |
**** Heating | Capacity |
Capacity | kW |
Power input | W |
Current | A |
Heating capacity at low temp. | kW |
Operating current | A |
Power consumption | kW |
**** Indoor motor | Brand |
Model | |
Type | |
Insulation class | |
IP class | |
Power input | W |
Power output (up/down) | W |
Speed (High/Middle/Low) | rpm |
**** Indoor fan | Brand |
Type | |
Quantity | |
**** Indoor coil | a. Number of rows |
b. Tube pitch (a)×row pitch(b) | mm |
c. Fin spacing | mm |
d. Fin type (code) | |
e. Tube outside dia. and type | mm |
f. Coil length×height×width | mm |
g. Number of circuits |
|
---|---
Cabinet| Cabinet coating type| | Plastic
Control box IP class| | IP20
**** Construction| Sheet metal thickness| | IP20
Drain pan material| | PS
Drain pan insulation| | 22
Drain pump option| | NO
Branch outlet option| | NO
Indoor wall| Material| | Plastic
Thickness| mm| /
Double or single skin| | Single
Air filter| Material| | PPP
Mesh| | 15*13
Pressure drop| Pa| 5
*** Piping dimension| Liquid pipe| mm| 6.35
Gas pipe12.7| mm| 12.7
Drain hose| mm| 16
Fresh air dimension| mm| /
Sound pressure level (H/M/L)| dB(A)| 45/42/39/35/32
Sound power level (H/M/L)58/55/52/48/45| dB(A)| 58/55/52/48/45
Standard static pressure| Pa| 0
Indoor air flow (H/M/L)| m3/h| 700/210/600
Dimension (WHD)| mm| 783/303/695
Packing (WH*D)| mm|
Net weight| kg| 15.2
Gross weight| kg| 18.7
Nominal condition: indoor temperature (cooling): 27DB (°C)/19WB (°C), indoor
temperature (heating): 20DB (°C) Outdoor temperature (cooling): 35DB (°C)/24WB
(°C), outdoor temperature (heating): 7DB (°C)/6WB (°C)The noise level will be
measured in the third octave band limited values, using a Real Time Analyser
calibratedsound intensity meter. It is a sound pressure noise level.
MODEL | XVVA-035N-01M22 | XVVA-050N-01M22 |
---|---|---|
Power supply | Ph-V-Hz | 1,220~230,50/60 |
**** Cooling | Capacity | kBtu/h |
Capacity | kW | 3.6 |
Power input | W | 34 |
Current | A | 0.32 |
**** Heating | Capacity | kBtu/h |
Capacity | kW | 4 |
Power input | W | 34 |
Current | A | 0.32 |
Heating capacity at low temp. | kW | 2.6 |
Operating current | A | 0.32 |
Power consumption | kW | 0.034 |
**** Indoor motor | Brand |
ZWK465A000114/SIC-41CVJ-F130-20
Model| | Broad-Ocean/Nidec| Broad-Ocean/Nidec
Type| | DC| DC
Insulation class| | E| E
IP class| | 41| 41
Power input| W| 34| 36
Power output (up/down)| W| 30| 30
Speed (High/Middle/Low)| rpm| 750/650/550/450/350| 800/700/600/500/350
Indoor fan| Brand| | Shunwei| Shunwei
Type| | Centrifugal| Centrifugal
Quantity| | 1| 1
**** Indoor coil| a. Number of rows| | 2| 2
b. Tube pitch (a)×row pitch(b)| mm| 2113| 2113
c. Fin spacing| mm| 1.4| 1.4
d. Fin type (code)| | Hydrophilic aluminum
e. Tube outside dia. and type| mm| Ф7 Inner groove tube
f. Coil length×height×width| mm| 509×378×26| 509×378×26
g. Number of circuits| | 3| 3
MODEL | XVVA-035N-01M22 | XVVA-050N-01M22 |
---|---|---|
**** Cabinet | Cabinet coating type | |
Control box IP class | IP20 | |
**** Construction | Sheet metal thickness | |
Drain pan material | PS | |
Drain pan insulation | 22 | |
Drain pump option | NO | |
Branch outlet option | NO | |
**** Indoor wall | Material | |
Thickness | mm | / |
Double or single skin | Single | |
**** Air filter | Material | |
Mesh | 15*13 | |
Pressure drop | Pa | 5 |
**** Piping dimension | Liquid pipe | mm |
Gas pipe | mm | 12.7 |
Drain hose | mm | 16 |
Fresh air dimension | mm | / |
Sound pressure level (H/M/L) | dB(A) | 47/44/41/38/34 |
Sound power level (H/M/L) | dB(A) | 60/57/54/51/47 |
Standard static pressure | Pa | 0 |
Indoor air flow (H/M/L) | m3/h | 580/500/420/350/270 |
Dimension (WHD) | mm | 700/210/600 |
Packing (WHD) | mm | 783/303/695 |
Net weight | kg | 15.2 |
Gross weight | kg | 18.7 |
Nominal condition: indoor temperature (cooling): 27DB (°C)/19WB (°C), indoor temperature (heating): 20DB (°C) Outdoor temperature (cooling): 35DB (°C)/24WB (°C), outdoor temperature (heating): 7DB (°C)/6WB (°C)The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibratedsound intensity meter. It is a sound pressure noise level.
Dimension
Piping diagram
Wiring diagram
Electric characteristics
Units | Power supply | Indoor fan motor | Power input (w) |
---|---|---|---|
Model | Phase | FQY | Voltage |
Heating
XVVA-025N-01M22| 1| 50/60| 220| 198~242| 0.38| 1.20| 30| 0.30| 31| 31
XVVA-035N-01M22| 1| 50/60| 220| 198~242| 0.39| 1.24| 30| 0.31| 34| 34
XVVA-050N-01M22| 1| 50/60| 220| 198~242| 0.43| 1.36| 30| 0.34| 36| 36
Symbols:
MCA: Min. circuit amps (A)
MFA: Max. fuse amps of circuit breaker
Output: Fan motor rated output (w)
FLA: Full load amps (A)
Note:
-
Voltage range
The units are applicable for the electrical systems where voltage supplied to unit is in the range. -
Maximum allowable voltage unbalance between phases is 2%.
-
MCA=1.25FLA MFA≤4FLA
-
Power supply uses the circuit breake
Air velocity and temperature distribution
A) On the floor
a. Cooling / Air velocity distribution
Cooling
Blowy angle: 25 Air velocity distributio
b. Cooling / Temperature distribution
Cooling
Blowy angle: 25 Temperature distribution
c. Heating / Air velocity distribution
Heating
Blowy angle: 5 Air velocity distribution
d. Heating / Temperature distribution
Heating
Blowy angle: 5 Temperature distribution
Sound pressure level
Testing illustrate:
Testing condition:
a. Unit running in the nominal condition.
b. Test in the semi-anechoic chamber.
c. Noise level varies from the actual factors such as room structure, etc
Octave band leve:
Installation
Parts
Operation hints
Emergency operation of indoor unit
- When the remote controller is lost or damaged, the emergency switch can be operated under the panel. (as shown in the figure).
- In the OFF state, pressing the emergency switch can turn on automatic operation. Air conditioning automatically selects operation mode according to indoor temperature (cooling or heating).
- However, temperature setting and wind speed can not be changed. In the ON state, press this button to stop the air conditioner.
Indoor air supply control
CAUTION
-
Before opening the front frille, be sure to stop the operation and tum the breaker OFF.
-
Do not touch the metal parts on the inside of the indoor unit, as it may result in injury.
-
Regardless of the operating mode or situation, air blows from the upper air outlet.
-
Use this swich when you do not want air coming out of lower air outlet. (While sleeping etc..)
-
Air conditioner automatically decides the appropriate blowing pattern depending on the operating mode and situation.
-
During Cool/Dry and Fan mode, so that cold air does not come into direct contact with people, air is blown upper air outlet.
EMERGENCY OPERATION AND TEST OPERATION EMERGENCY OPERATION
Carry out ghis operation only when the remote controller is defective or lost.
Unit start
When the emergency operation switch is pressed, a sound you can hear, which
means the start of this operation
Follow the requriements below.
Room temperature| Designated temperature| Timer mode| Air
flowspeed| Operation mode| Anion
---|---|---|---|---|---
23°C| 26°C| None| AUTO| COOL| None
≤23°C| 23°C| None| AUTO| HEAT| None
Unit stop (to cancel emergercy operation) Press the emergency switch and hear a sound, the unit stops.
TEST OPERATION
Use this switch in the test operation when the room temperature is less than 16 °C, do not used it in the normal operat
Unit start
Continue to press the test operation switch for more than 5 seconds. After you
hear the ”Bl” sound twice, release your finger from the switch, the test
operation starts and the air conditioner srarts with the air flow speed
setting ”Hl”.
Unit stop (to cancel test operation)
Push the test run switch or operate with remote controller to cancel the test
run. If you use the remote controller to cancel the test run, the conditioner
will then run as per the working mode displayed on the remote controller.
Power failure resume (please set and apply as necessary)
With setting of power failure resume, if sudden power failure occurs, the unit
will resume original operation when power is supplied again.
Setting method:
with ON of remote controller (except TIMER and FAN),repeatedly press SLEEP
button 10 times in 5 seconds,after 4 Beep from the buzzer,the unit comes into
power failure resume mode.
To cancel:
press SLEEP button continuously 10times in 5 seconds,the buzzer sounds Beep
twice and power failure resume function is canceled.
Note :
When sudden power failure happens during unit operation in power failure
resume mode, if the air conditioner is not desired for use in a long period,
please shut off the power supply in case that the unit automatically resume
operation when power is re-supplied, or press ON/OFF to turn off the unit when
power resumes
Special function
A. Emergency switch:
a) Press the emergency switch in stop condition, indoor unit operate with
AUTO, AUTO SPEED, 24 Setting modes, pressure the emergency switch in start
condition, indoor unit will stop operation.
b) Malfunction history list checking: In cooling or heating mode, using
the remote controller set automatic wind
speed, press Press SWING button 6 times can query the recent history of fault,
the times the buzzer rang or timing lights flashing times stands for a recent
fault code
B. Temp. consumption:
The heating mode, the temp. compensation range is -14 ~ 0°C. Set the temp.
consumption in Heating mode with remote controller, heating mode ,set 30°C as
the reference point, press the sleep butter 7 times, the buzzer ring 2 times,
the unit enter temp. consumption condition. Temp. consumption data=current
temp.-30 °C In the cooling mode, the temp. compensation range is -7 ~ 7 °C .
Set the temp. consumption in Cooling mode with remote controller, cooling mode
,set 23°C as the reference point, press the sleep butter 7 times in 5 seconds
, the buzzer ring 2 times, the unit enter temp. consumption condition. Temp.
consumption data=current temp.-23°C
C. Compulsive Defrost:
In heating mode, setting high speed ,set temp. is 30 °C , press sleep button
for 6 times, buzzer short ring 3 times, unit enter manual defrost mode..
D. Auto start function:
In on condition ,press the sleep button 10 times within 5 seconds, buzzer
short ring 4 times stands for enter auto
restart function; press the sleep button 10 times within 5 seconds, buzzer
short ring 2 times stands for exit auto restart function . The memory
information: on/off condition, mode, fan speed, setting temp., swing position
E. Room card Function:
Room card function can realize by remote controller. Press the light button 12
times with remote controller,if the buzzer rings 4 times that the room card is
valid, if the buzzer rings 2 times that the room card is invalid.
Note:
If the wired controller is selected, then the implementation of special
functions of A, B, C and D can refer to the wired controller manual. E
function shall be set up by the installation personnel during debugging and
installation
Installation Procedures
CAUTIONS:
To ensure proper installation, read ”Cautions” carefully before working. After
installation, start the unit correctly and show customers how to operate and
maintain the unit.
Meanings of Warning and Cautions :
WARNING : Serious injury or even death might happen, if it is not
observed.
CAUTION : lnjury to people of damages to machine might happen, if it is
not observed
WARNING
- Installation shall be done by professional people, don’t install unit by yourself. Incorrect installation will cause water leakage, electric shock or fire.
- Install unit as per the Manual. Incorrect installation will cause water leakage, electric shock or fire accident.
- Be sure to use specified accessaries and parts. Otherwise, water leakage, electric shock, fire accident or unit falling down may happen.
- Unit should be placed on a place strong enough to hold the unit. Or, unit will fall down causing injuries.
- When install the unit, take in consideration of storms, typhoom, earthquake. Incorrect installation may cause unit to fall down.
- All electric work shall be done by experienced people as per eocal code, regulations and this Manual.
- Use exclusive wire for the unit. Incorrect installation or undersized electric wire may cause electric shock or fire accident.
- All the wires and circuit shall be safe. Use exclusive wire firmly fixed. Be sure that external force will not affect terminal bolck and electric wire. Poor contact and installation may cause fire accident. Arrange wire correctly when connectin indoor and outdoor power supply. Fix terminal cover firmly to avoid
- In case retrigerant leakage occurred during unit installation, keep a good ventilation in the room.
- Poisonous gas will occur when meet with fire.
- Check the unit upon installation. Be sure there is no leakage. Refrigerant will induce poisonous gas when meet heat source as heater, oven, etc.
- Cut power supply before touching terminal bolck
CAUTION:
-
Unit shall be grounded. But grounding shall not be connected to gas pipe water pipe, telephone line. Poor grounding will cause electric shock.
-
Be sure to install a leakage breaker to avoid electric shock.
-
Arrange water drainage according to this Manual. Cover pipe with insulation materials in case dew may occur. Unproper installation of water drainage will cause water leakage and wer your furniture.
-
To maintain good picture or reduce noise, keep at least 1 m from T.V. radio, when install indoor and outdoor unit,
connecting wire and power line. (If the radio wave is relatively strong, 1 m is not enough to reduce noise). -
Don’t install unit in following places:
(a) Oil mist or oil gas exists, such as kitchen, or, plastic parts may got aged, or water leakage.
(b) Where there is corrosive gas. Copper tube and welded part may be damaged due to corrosion, causing leakage.
(c) Where there is strong radiation. This will affect unit’s control system, causing malfunction of the unit
(d) Where flamable gas, dirt, and volatile matter (thinner, gasoline) exist, These matter might cause fire accident. -
Refer to paper pattern when installing unit.
Cautions for the installation personnel
Don’t fail to show customers how to operate unit.
BEFORE INSTALLATION <Don’t discard any accessories until comp>
- Determine the way to carry unit to installation place.
- Don’t remove packing until unit reaches installation place.
- If unpacking is unkavoidable, protect unit properly.
SELECTION OF INSTALLATION PLACE
Installation place shall meet the following and agreed by customers:
- Place where proper air flow can be ensured.
- No block to air flow. Water drainage is smpoth.
- Place strong enough to support unit weight. Place where inclination is not evident on ceiling.
- Enough space for mainenance.
- Indoor and outdoor unit piping length is within limit. (Refer to Installation Manual for outdoor unit.)
- Indoor and outdoor unit, power cable, inter unit cable are at least 1 m away fromT.V. radop.
This is helpful to avoid picture disturbance and noise. (Even if 1 m iskept, noise can still appear if radio wave is strong)
DRAWING FOR THE INSTALLATION OF INDOOR UNITS
Indoor Unit Installation
- Making a Hole on the Wall and Fitting the Piping Hole Cover
- Make a hole of 55mm in diameter, slightly descending to outside the wal
- Install piping hole cover and seal it off with putty after installation.
- Installation of the Indoor Unit Removal of Front Grille
-
Hole the front panel by the tabs on the both sides and lift it until it stops with a click.
-
Loosen the marked four screws and open the grille.
Drawing of pipe
[Rear piping]
- Draw pipes and the drain hose, then fasten them with the adhesive tape. [Left-Left-rear piping]
- In case of left side piping, cut away, with a nipper, the lid for left piping.
- In case of left-rear piping, bend the pipes according to the piping direction to the mark of hole for left-rear piping which is marked on heat insulation materials.
- Insert the drain hose into the dent of heat insulation materials of indoor unitl.
- Insert the indoor/outdoor electric cable from backside of indoor unit, and pull it out on the front side, then connect them.
- Coat the flaring seal face with refrigerant oil and connect pipes. Cover the connection part with heat insulaiton materials closely, and make sure fixing with adhesive tape.
-
Indoor/outdoor electric cable and drain hose must be hound with efrigerant piping by protecting tape.
[Other direction piping] -
Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to the position of wall hole, When bending,be careful not to crash pipes.
-
Connect beforehand the indoor/outdoor electric cable, and then pull out the connected to the heat insulation of connecting part specially
Fixing the indoor unit body
lndoor installation can be done in any of the following two ways:
-
Fix the wall board,then use four screws to fix the unit on the wall. As the figure shown.
-
Remove the front panel, then use two fastening screws to fix the unit on the floor. As the figure shown
-
Once refrigerant piping and drain piping connections are complete, fill the gap of the through hole with putty. Attach the front panel and front grille in their orginal positions once all connections are complete
REFRIGERANT PIPING
- (As for outdoor piping, please refer to installation Manual of outdoor unit.)
- Outdoor is precharged with refrigerant.
- Be sure to see the Fig.1, when connecting and removing piping from unit.
- For the size of the flare nut, please refer to Table 1.
- Apply refrigerant oil at both inside and outsid of lflare nut. Tighten it band tight 3-4 turns then tighten it.
- Use torque specified in Table 1. (Too much force may damage flare nut, causing gas leakage).
- Check piping joints for gas leakage. Insulate piping as shown in Fig. below.
- Cover joint of gas piping and insulator 7 with seal.
Pipe size
Model | Gas pipe | Liquid pipe |
---|---|---|
XVVA-050/035/025N-01M22 | ø6.35mm | ø12.7mm |
Table 1
Pipe size | Tighten torque | A(mm) | Flare shape |
---|---|---|---|
ø6.35 | 1420~1720N.cm (144~176kgf.cm) | 8.3~8.7 | ![Flare |
shape](https://manuals.plus/wp-content/uploads/2023/08/Screenshot_29-59.jpg)
ø9.52| 3270~3990N.cm (333~407kgf.cm)| 12.0~12.4
ø12.7| 4950~6030N.cm (490~500kgf.cm)| 12.4~16.6
ø15.88| 6180~7540N.cm (630~770kgf.cm)| 18.6~19.0
ø19.05| 9720~11860 N.cm (990~1210 kgf.cm)| 22.9~23.3
INSTALLATION OF WATER DRAINAGE PIPE
(1) Install water drainage pipe
-
Pipe dia, shall be equal or larger than that of unit piping.(pipe of polyethylene; size: 20mm; O.D:26mm)
-
Drain pipe should be short, with a downward slope at least 1/100 to prevent air bag from happening.
-
If downward slope can’t be made, take other measures to lift it up.
-
Please install the drain hose so as to be downward slope without fall.
-
Please don’t do the drainage as shown below.
-
Please pour water in the drain pan of the indoor unit, and confirm that drainage is carried out surely to outdoor.
-
In case that the attached drain hose is in a room, please apply heat insulation to it without fall.
-
Use the self-provided stiff pipe and clamp with unit. Insert water pipe into water plug until it reaches the white tape.
-
Insulate drain hose in the room.
Electrical Wiring
Warning
- Electrical construction should be made with specific mains circuit by the qualified personnel according to the installation instruction. Electric shock and fire may be caused if the capacity of power supply is not sufficient.
- During arranging the wiring layout, specified cables should be used as the mains line, which accords with the local regulations on wiring. Connecting and fastening should be performed reliably to avoid the external force of cables from transmitting to the terminals. Improper connection or fastness may lead to burning or fire accidents.
- There must be the ground connection according to the criterion. Unreliable grounding may cause electrical shocks. Do not connect the grounding line to the gas pipe, water pipe, lightening rod and telephone l
Attention
-
Only copper wire can be used. Breaker for electric leakage should be provided, or electric shock may occur.
-
The wiring of the mains line is of Y type. The power plug L should be connected to the live wire and plug N connected to null wire while should be connected to the ground wire. For the type with auxiliary electrically heating function, the live wire and the null wire should not be misconnected, or the surface of electrical heating body will be electrified. If the power line is damaged, replace it by the professional personnel of the manufacturer or service center.
-
The power line of indoor units should be arranged according to the installation instruction of indoor units.
-
The electrical wiring should be out of contact with the high-temperature sections of tubing as to avoid melting the insulating layer of cables, which may cause accidents.
-
After connected to the terminal tier, the tubing should be curved into be a U-type elbow and fastened with the pressing clip.
-
Controller wiring and refrigerant tubing can be arranged and fixed together.
-
The machine can’t be powered on before electrical operation. Maintenance should be done while the power is shut down.
-
Seal the thread hole with heat insulating materials to avoid condensation.
-
Signal line and power line are separately independent, which can’t share one line. [Note: the power line, signal line are provided by users. Parameters for power lines are shown as below: 3×(1.0-1.5) mm2 ; parameters for signal line: 2×(0.75-1.25)mm2 (shielded line)]
-
5 butt lines (1.5mm) are equipped in the machine before delivery, which are used in connection between the valve box and the electrical system of the machine. The detailed connection is displayed in the circuit diagram
-
lndoor units and outdoor units should be connected to the power source separately. lndoor units must share one single electrical source, but its capacity and specifications should be calculated. lndoor & outdoor units should be equipped with the power leakage breaker and the overflow breaker.
Signal Wiring Drawing?
Outdoor units are of parallel connection via three lines with polarity. The
master unit, central control and all indoor units are of parallel connection
via two lines without polarity. The singal line between wired controller and
indoor units are polarity There are three connecting ways between wired
controller and indoor units:
A. One wired controller controls one indoor unit, the wired controller
connects with the ABC terminal of indoor unit.
B. Two wired controllers control one indoor unit. Either of the wired controls can be set to be the master wired controller while the other is set to be the slave wired controller.
Master and slave controller setting method for RWV05, other controllers’ setting method please refer to the controller manual
No. | Type | State of switch | Function description |
---|---|---|---|
SW1-1 | Select the master or the slave controller | ON | Slave controller |
OFF | Master controller |
C. One wired controller controls multiple units
0151800452 PCB
Note:
- Plug the wired controller terminal to the CN22 terminal of master unit which wired address is 0.
- The CN22-1 terminal of the previous unit is connected to the CN22 terminal of the next unit
- Wired address setting
0151800452SW01_1 SW01_2 SW01_3 SW01_4| Wired control address| [1]| [2]| [3]| [4]| Wired control address
---|---|---|---|---|---|---
OFF| OFF| OFF| OFF| Master unit in group control
OFF| OFF| OFF| ON| Slave unit 1 in group control
OFF| OFF| ON| OFF| Slave unit 2 in group control
OFF| OFF| ON| ON| Slave unit 3 in group control
…| …| …| …| ……
ON| ON| ON| ON| Slave unit 15 in group control - One controller can Max. control 16 indoor units.
- Hand-in-hand connection method
- The singal line is polarity
- The singal line diameter and length
Length of signal line (m)| Wiring dimensions
---|---
≤ 250| 0.75mm2×3 core shielded line
- The shielding lay of the signal line must be grounded at one end.
- The total length of the signal line shall not be more than 250m
Indoor power supply wiring & signal wiring between indoor and outdoor & signal wiring between indoor
Items
Total current ofindoor units (A)| Cross section (mm2)| Length (m)| Rated
current of overflow breaker (A)| Rated current of residual circuit breaker
(A)Ground fault Interrupter (mA) Response time (S)| Cross sectionalarea of
signal Line
---|---|---|---|---|---
Outdoor-indoor (mm2)| Indoor-indoor (mm2)
<7| 2.5| 20| 10| 10 A, 30 mA, 0.1S or below| 2 cores×(0.75-2.0)mm2 shielded
line
≥7 and <11| 4| 20| 16| 16 A, 30 mA, 0.1S or below
≥11 and <16| 6| 25| 20| 20 A, 30 mA, 0.1S or below
≥16 and <22| 8| 30| 32| 32 A, 30 mA, 0.1S or below
≥22 and <27| 10| 40| 32|
- The electrical power line and signal lines must be fastened tightly.
- Every indoor unit must have the ground connection.
- The power line should be enlarged if it exceeds the permissible length.
- Shielded lays of all the indoor and outdoor units should be connected together, with the shielded lay at the side of signal lines of outdoor units grounded at one point.
- It is not permissible if the whole length of signal line exceeds 1000m.
Test Run & Fault Code
Before Test Run
- Before switching it on, test the supply terminal tier (L, N terminals) and grounding points with 500V megaohm meter and check if the resistance is above 1MO. lt can’t be operated if it is below 1MΩ.
- Connect it to the power supply of outdoor units to energize the heating belt of the compressor. To protect the compressor at startup, power it on 12 hours prior to the operation.
Check if the arrangements of the drainpipe and connection line are
correct.
The drainpipe shall be placed at the lower part while the connection line
placed at the upper part. Heat preservation measures should be taken such as
winding the drainpipe esp. in the indoor units with heating insulating
materials. The drain pipe should be made a slope type to avoid protruding at
the upper part and concaving at the lower part on the way
Checkup of Installation
- check if the mains voltage is matching
- check if there is air leakage at the piping joints
- check if the connections of mains power and indoor & outdoor units are correct
- check if the serial numbers of terminals are matching
- check if the installation place meets the requirement
- check if there is too much noise
- check if the connecting line is fastened
- check if the connectors for tubing are heat insulated
- check if the water is drained to the outside
- check if the indoor units are positioned
Ways Of Test Run
Do ask the installation personnel to make a test run. Take he testing procedures according to the manual and check if the temperature regulator works properly. When the machine fails to start due to the room temperature, the following procedures can be taken to do the compulsive running. The function is not provided for the type with remote control.
- Set the wired controller to refrigerating/heating mode, press “ON/OFF” button for 5 seconds to enter into the compulsive refrigerating/heating mode. Repress “ON/OFF” button to quit the compulsive running and stop the operation of the air conditioner.
WARNING :
The design and specifications are subject to change without prior notice for
product improvement. Consult with the sales agency or manufacturer for
details.
AIRWELL RESIDENTIAL SAS
10,Rue du Fort de Saint Cyr,
78180 Montigny le Bretonneux – France
www.airwell.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>