AcuityBrands IC1JB JSF LED New Construction Junction Box Surface Mount Downlight Instruction Manual

June 12, 2024
AcuityBrands

IC1JB JSF
JUNO SLIMFORM ™ LED
IC RATED LED NEW CONSTRUCTION JUNCTION BOX SURFACE MOUNT DOWNLIGHT
FOR INSTALLATION INTO
FIRE RATED CEILING ASSEMBLIES
IC1JB JSF

IC1JB JSF LED New Construction Junction Box Surface Mount Downlight

Project:|
---|---
Fixture Type:|
Location:|
Contact/Phone:|

PRODUCT DESCRIPTION

IC LED Air-Loc ® new construction junction box housing with energy efficient Juno SlimForm™ LED round surface mount trim for a complete downlight solution in
multiple sizes 7″ to 13″

  • May be installed in maximum 2 hour fire-rated ceiling assemblies per International Building Code Section 714
  • Can be completely covered with insulation
  • Dimmable
  • Optional finish trims and shrouds available for custom, designer look similar to standard recessed downlights
  • Designed to provide 50,000 hours of life
  • 5 year limited warranty.

PRODUCT SPECIFICATIONS – TRIM

Surface Mount Trim Shallow, less than 1″, solid ring with white finish

  • Non conductive fixture for shower light applications
  • Optional, field installable finish trims available for 7″ version to change the exterior finish of fixture
  • Optional, field installable decorative baffle and cone shrouds for 7″ version provides the aesthetic and source shielding similar to the experience of a fully recessed downlight.

Optics Light quide technology combined with diffusing lens conceals the LEDs from direct view and provides uniform lens luminance.
LED Light Engine LEDs mounted directly to heatsink designed to provide superior thermal management and ensure long life

  • 2700K, 3000K, 3500K or 4000K LED color temperature
  • LEDs binned for 4-step MacAdam ellipse color consistency
  • 90 CRI minimum.

LED Driver Choice of dedicated 120 volt (120) driver or universal voltage (MVOLT) driver that accommodates input voltages from 120-277 volts AC at 50/60Hz

  • Power factor > 0.9 at 120V input
  • 120 volt driver is dimmable with the use of most incandescent, magnetic low voltage and electronic low voltage wall box dimmers
  • Universal voltage driver is dimmable with the use of most 0-10V wall box dimmers
  • External driver is only available on 7″ model
  • For a list of compatible dimmers, see JUNOSLIMFORM-DIM.

Emergency Battery Option Available on fixture sizes 11″ and larger

  • Battery factory assembled to fixture with integral test switch (EL option)
  • Drives LEDs for 90 minutes to meet Life Safety Code (NFPA-LSC), National Electrical Code (NEC), and UL requirements
  • Title 20 certified battery pack available when ordering E10WLCP option
  • EBX option provides back box without battery for consistent look when used in same space as fixtures with EL emergency option.
    Electrical Connections Fixture provided with leads for direct wire connection.
    Life Rated for 50,000 hours at >70% lumen maintenance.

PRODUCT SPECIFICATIONS – HOUSING

Junction Box Housing Designed for use in IC (insulated ceiling) or non-IC construction

  • Rough-in section (junction box, bar hangers) fully assembled for ease of installation
  • Painted steel 3-1/2″ deep 4″ square juction box
  • Provided with (4) 1/2″-3/4″ concentric, (2) 1/2″, (4) 3/4″ and (2) 1″ knockouts
  • cETLus listed for through-branch wiring, maximum 8 No. 12 AWG 90°C branch circuit conductors (4 in and 4 out).

Hardware Ships with retrofit mounting bracket, trim ring and quick connect whip; not required for JSF installation.

INSTALLATION

The IC1JB junction box housing must be installed per the International Building Code Section 714 guidelines to maintain up to a 2 hour ceiling fire rating. Precise ceiling cutout required. For use with ½” – 1-1/4″ ceiling thickness.
Mounting option JSFMTGPLT 4X4 is required for installation.
Real Nail ® 3 Bar Hangers Telescoping Real Nail 3 system permits quick placement of housing anywhere within 24″ O.C. joists or suspended ceilings

  • Bars scored in two locations for fast, clean breaking, allowing housing installation in tight applications
  • Captive bugle-headed ring shank nail for quick one-step installation and easy removal with claw hammer for fixture relocation
  • Integral T-bar notch for suspended ceilings
  • Locking set screw to lock junction box housing in position
  • Design covered under US Patent D552,969.

LISTINGS

Labels ENERGY STAR ® certified

  • Certified to the high efficacy requirements of California T24 JA8-2016
  • Assembly ETL listed to UL1598 for US and Canadian through branch wiring, damp location
  • ETL listed to UL514A • Suitable for wet locations (covered ceilings).

Testing All reports are based on published industry procedures; actual performance may differ as a result of the end-user environment and applications. All values are design or typical values, measured under laboratory conditions at 25 °C.
Warranty 5-year limited warranty. This is the only warranty provided and no other statements in this specification sheet create any warranty of any kind. All other express and implied warranties are disclaimed. Complete warranty terms located at: www.acuitybrands.com/support/warranty/termsand- conditions
Note: Actual performance may differ as a result of end-user environment and application.
All values are design or typical values, measured under laboratory conditions at 25 °C.
Specifications subject to change without notice.

FOR INSTALLATION INTO FIRE RATED CEILING ASSEMBLIES

DIMENSIONS

ROUND SPECIFICATIONS

| Width| Depth
---|---|---
JSF 7IN| 7.77 (19.74)| 0.75 (1.91)
JSF 11IN| 11.08 (28.14)| 0.9 (2.29)
JSF 13IN| 13.05 (33.15)| 0.9 (2.29)

All dimensions are in inches (centimeters) unless otherwise indicated.

JSF PERFORMANCE DATA

| JSF 7IN| JSF 1 IIN| JSF 13IN
---|---|---|---
| 120V| MVOLT| 120V| MVOLT| 120V| MVOLT
Lumens| 1000| 1000| 1300| 1300| 1800| 1800
CRI| 90CRI| 90CRI| 90CRI
CCT| 27K, 30K, 35K, 40K| 27K, 30K, 35K, 40K| 27K, 30K 35K, 40K
Voltage| 120V| 120V-277V| 120V| 120V-277V| 120V| 120V-277V
Input Power| 13W| 13W| 15W| 15W| 20W| 20W
Input Current| 150MA| 60MA| 180MA| 80MA| 240MA| 110MA
Frequency| 50/60Hz| 50/60Hz| 50/ 0Hz
Power Factor| >0.9| >0.9| >0.9

JSFMTGPLT 4X4
(Required for JSF installation)

EMERGENCY BATTERY FOR 11″ AND 13″

FOR INSTALLATION INTO FIRE RATED CEILING ASSEMBLIES

ORDERING INFORMATION

Example: IC1JB JSF 7IN 10LM 27K 90CRI 120 FRPC WH JSFMTGPLT
Junction box and trim can be ordered together or separate, but will always ship separately.

Series| Trim Series| Size/Lumens| Color Temperature| CRI
---|---|---|---|---
IC1JB New Construction Junction Box
for Fire Rated Ceiling Assemblies| JSF SlimForm Surface Mount Downlight – Round| 7IN 10LM 7″, 1000 Lumens
11IN 13LM 11″, 1300 Lumens
13IN 18LM 13″, 1800 Lumens| 27K 2700K
30K 3000K
35K 3500K
40K 4000K| 90CRI 90+ CRI
Voltage/Driver| Finish| Mounting Option| Emergency Battery 1,2,3
---|---|---|---
120 FRPC Dedicated 120V, Forward Reverse Phase Dimming MVOLT ZT Universal Voltage 120V-277V,
0-10V Dimming| WH White| JSFMTGPLT Slim Form mounting plate for
installation to 4X4 junction box| EL3† Battery Back-up Option
EBX Empty Back Box for Aesthetics E10WLCP 4†
EM Self-Diagnostic battery pack, 10W Constant Power, Certified in CA Title 20 MAEDBS.

JSFMTGPLT 4X4 required for use of IC1JB with JSF.
†: EL Battery Back-up option is not Energy Star certified
**: See Option Value Ordering Restrictions

TRIM – Optional, field installable finish trim rings available to change the exterior finish of fixture.
Example: JSFTRIM 7IN BZ

Series Size Finish

JSFTRIM SlimForm
Accessory- Trim| 5IN 5 inches
7IN 7 inches| BL Black
BZ Bronze
SN 5 Satin Nickel

Note:

  1. Emergency battery available with 11IN and 13IN only.
  2. Emergency battery is only available with MVOLT ZT.
  3. Emergency battery option not available in California due to Title 20 restrictions and is not ENERGY STAR ® compliant.
  4. E10WLCP ordering option is Title 20 certified for shipments to California.
  5. SN not available in 5IN.

Option Value Ordering Restrictions

JSF 120V Fixtures
Option Value| Restriction
5IN| Not available in 35K and 40K CCT
7IN| Not available in 30K CCT
131N| Not available in 35K and 40K CCT
JSF MVOLT Fixtures
5IN| Not available in 40K CCT
71N| Not Available in 30K and 35K CCT
1 1 IN| Not available in 27K, 30K, 35K and 40K CCT
131N| Not available in 27K CCT

FOR INSTALLATION INTO FIRE RATED CEILING ASSEMBLIES

PHOTOMETRICS

Distribution Curve| Distribution Data| Coefficient of Utilization| Illuminance Data at 30″ Above Floor for a Single Luminaire
---|---|---|---

JSF 7IN 27K, 2700K LEDs, input watts: 12.8, delivered lumens: 1060, LM/W = 82.8, test no. ISF 33600, tested in accordance to IESNA LM-79.

JSF 11IN 27K, 2700K LEDs, input watts: 15.2, delivered lumens: 1305, LM/W = 85.9, test no. ISF 33661, tested in accordance to IESNA LM-79.

JSF 13IN 27K, 2700K LEDs, input watts: 20.2, delivered lumens: 1779, LM/W = 88, test no. ISF 33663, tested in accordance to IESNA LM-79.

For 30K fixtures, use 1.02 multiplier; For 35K fixtures, use 1.03 multiplier, For 40K fixtures, use 1.07 multiplier.

One Lithonia Way • Conyers, GA 30012 • Phone 1-800-705-SERV (7378) • Visit us at www.acuitybrands.com
Printed in U.S.A. © 2018-2023 Acuity Brands Lighting, Inc. 05/30/23
Light Commercial & Residential

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

AcuityBrands User Manuals

Related Manuals