CleanSpace C5T1001 Pro Respirators Instruction Manual

June 12, 2024
CleanSpace

USER INSTRUCTIONS

CleanSpace C5T1001 Pro Respirators - ClEan Space PRO CST1001

Please take a moment to register for warranty of your CleanSpace Respirator at cleanspacetechnology.com/warrantyregistration.
Before use, the wearer must read and understand the entirety of these User Instructions including all warnings, all additional information relating to the appropriate use of CleanSpace filters and accessories and all relevant information documented in national standards. If you have questions regarding this system, please contact CleanSpace Customer Service on +612 8436 4000 or e-mail [email protected].
This product is part of a system that helps protect against certain airborne contaminants. Misuse may result in sickness. For proper use, consult an Occupational Health Specialist, these User Instructions or contact CleanSpace Technology Customer Support on [email protected].

Warnings & Limitations

1.1. LIST OF WARNINGS WITHIN THESE USER INSTRUCTIONS
1.1.1 GENERAL

  • This product is part of a system that helps protect against certain airborne contaminants. Misuse may result in sickness.
    For proper use, consult an Occupational Health Specialist, these User Instructions or contact CleanSpace Technology Customer Support on [email protected].

  • Properly selected, used and maintained respirators help to protect against certain airborne contaminants. It is essential to follow all instructions and government regulations on the use of this product in order for the product to help protect the wearer. Misuse of respirators may result in overexposure to contaminants and lead to sickness. For proper use, consult an Occupational Health Specialist, these User Instructions or contact CleanSpace Technology Customer Support on [email protected] or the website: cleanspacetechnology.com

  • You must recalibrate the internal pressure sensor any time that your CleanSpace Respirator is exposed to changes in temperature of more than 36°F (20°C), changes in altitude of more than 328ft (100m) or before using the respirator for the first time. It is best practice to also recalibrate if the unit has been in storage, particularly if the storage temperature is not known.

1.1.2 BATTERY

  • Using the respirator after the Low Battery Alarm has triggered can cause the flow to fall below the minimum design flow. This may result in overexposure to contaminants and lead to sickness.
  • Always correctly use and maintain the internal lithium-ion battery packs. Failure to do so may result in fire or explosion, or could adversely affect respirator performance and result in injury, sickness or death.
  • CleanSpace PRO is not intrinsically safe. Do not use in flammable or explosive atmospheres. Doing so may result in injury or death.
  • In the extremely rare circumstance that the battery is damaged and electrolyte comes in contact with eyes, flush with water immediately and seek urgent medical attention.
  • The battery shall only be charged in non-hazardous areas. Move out of the hazardous area before charging. The Power Unit must not be placed on charge in enclosed cabinets without ventilation, near flammable liquids or gases or near heat sources. Do not use, charge or store the device outside the recommended temperature limits.
  • CleanSpace Respirators use a unique charger. Do not attempt to charge your CleanSpace Respirator with any other charger.
  • CleanSpace Power Units contain a battery, sensitive electronics, and a motor. NEVER immerse the Power Unit in water.

1.1.3 FILTER

  • Using a filter that has exceeded service limits can cause the flow to fall below the minimum design flow. This may result in overexposure to contaminants and lead to sickness.
  • Using the respirator without a filter installed will provide no respiratory protection. This may result in overexposure to contaminants and lead to sickness.
  • Do not use compressed air or a brush to clean the filter. HEPA filters are very easily damaged by using compressed air or by brushing. Misuse of CleanSpace Respirators by cleaning the filter may result in overexposure to contaminants and lead to sickness.
  • It is essential that the correct filter type is selected for the chosen application.
  • Use only NIOSH-approved CleanSpace filters. If used with other filters CleanSpace Respirators are not NIOSH approved.
    Use of other filters may result in overexposure to contaminants and lead to sickness.

1.1.4 OPERATION

  • If a satisfactory quantitative fit factor or a passing qualitative test cannot be achieved with any of the masks, the CleanSpace Respirator must not be used.
  • Be sure to remove the Seal Check Cap before entering the contaminated area. The cap blocks the exhalation valve, making it more difficult for your exhaled air to be expelled from the mask. Failure to remove the cap will lead to increased levels of rebreathed Carbon Dioxide and may result in headache or dizziness. Never leave the cap in place for more than 2 minutes.
  • If a satisfactory seal check cannot be achieved, do not enter the contaminated area.
  • If the Power Unit stops or the user encounters difficulty with the respirator, leave the contaminated area. If you have an acute or spontaneous health episode (i.e. experiencing dizziness) and believe removing the respirator while you leave the contaminated area may help, remove the respirator and leave the contaminated area immediately.
  • Never dry the mask or exhalation valve with a cloth that may leave behind lint. Lint contamination of the exhalation valve may cause it to leak, resulting in overexposure to contaminants and lead to sickness.

Throughout these User Instructions, this symbol will highlight important warnings.

1.2. LIMITATIONS
Use this respirator strictly in accordance with the information contained in these User Instructions. Never modify or alter this product.
1.2.1 CLEANSPACE RESPIRATOR LIMITATIONS

  • Please refer to your local standards and your workplace guidelines to determine the respiratory protection equipment that is most suited to your workplace and your needs.
  • This respirator, when used with the Half Mask, does not protect your eyes. In conditions that may damage or irritate eyes, use protective eyewear.
  • Only use your respirator with the approved parts and accessories listed on the Approval Label.
  • Do not use the respirator unless it is powered and running normally.
  • Do not use the respirator while it is being charged.
  • Do not use in airborne contaminant concentrations above those specified in your national regulations.
  • Do not use for respiratory protection against unknown atmospheric contaminants or when concentrations of contaminants are unknown or immediately dangerous to life or health (IDLH).
  • Do not use in oxygen deficient or oxygen enriched atmospheres. Do not use in flammable or explosive environments.
  • Only for use by trained personnel.
  • Filters need to be changed regularly. The frequency of change depends on use and the concentration of contaminants in the atmosphere.
  • Do not use for escape purposes. National regulations may impose specific limitations on the use of filters depending on the filter class and the facemask used.
  • If the respirator has been used in an area that has caused it to become contaminated with a substance requiring special decontamination procedures it should be placed in a suitable container and sealed until it can be decontaminated.
  • Do not disassemble the respirator case. There are no user serviceable parts inside.
  • Failure to follow all instructions on the use of this product, and/or failure to use the respirator during times of exposure, may lead to adverse effects on the wearer’s health and may render the warranty void.

1.2.2 IMMEDIATE EVACUATION
Leave the contaminated area immediately if any of the following occurs. If the user encounters breathing difficulty the respirator should be doffed.

  • The respirator warning lights and/or sounds activate for the Low Battery Alarm, Filter Absent Alarm or the Filter Change Alert.
  • Any part of the respirator is damaged.
  • Airflow into the mask decreases or stops.
  • Breathing becomes difficult or increased resistance occurs.
  • You feel dizzy or your airway is irritated.
  • You can taste or smell contaminants.

1.2.3 OPERATING CONDITIONS
Your respirator is suitable for use in the following atmospheric conditions.

  • Temperature: 14°F to 113°F (-10°C to 45°C).
  • Relative humidity: 0 to 90% non-condensing.

The respirator will stop functioning if its internal temperature rises above 140°F (60°C) or falls below 14°F (-10°C).
If using the respirator at an altitude greater than 655ft (200m) above sea level or less than 0ft (0m), make sure the operating altitude is set correctly before use. The operating altitude can be set by either recalibrating the Power Unit (see Section 3.3) or by using the CleanSpace Smart App.
This product is part of a system that helps protect against certain airborne contaminants. Misuse may result in sickness. For proper use, consult an Occupational Health Specialist, these User Instructions or contact CleanSpace Technology Customer Support on [email protected].

1.3. NIOSH – APPROVAL, CAUTIONS AND LIMITATIONS

1.3.1 NIOSH APPROVAL
CleanSpace PRO is a NIOSH-approved respirator system. Refer to these User Instructions and to the NIOSH approval label provided with each CleanSpace PRO for a listing of components that can be used to form a NIOSH-approved respirator.
1.3.2 NIOSH CAUTIONS AND LIMITATIONS
A – Not for use in atmospheres containing less than 19.5 percent oxygen.
B – Not for use in atmospheres immediately dangerous to life or health.
C – Do not exceed maximum use concentrations established by regulatory standards.
F – Do not use powered air-purifying respirators if airflow is less than four cfm (115 lpm) for tight fitting facepieces or six cfm (170 lpm) for hoods and/or helmets.
I – Contains electrical parts that may cause an ignition in flammable or explosive atmospheres.
J – Failure to properly use and maintain this product could result in injury or death.
L – Follow the manufacturer’s User’s Instructions for changing cartridges, canister and/or filters.
M – All approved respirators shall be selected, fitted, used, and maintained in accordance with MSHA, OSHA, and other applicable regulations.
N – Never substitute, modify, add, or omit parts. Use only exact replacement parts in the configuration as specified by the manufacturer.
O – Refer to User’s Instructions, and/or maintenance manuals for information on use and maintenance of these respirators.
P – NIOSH does not evaluate respirators for use as surgical masks.
S – Special or critical User’s Instructions and/or specific use limitations apply. Refer to User’s Instructions before donning.
1.4. S – SPECIAL OR CRITICAL USER INSTRUCTIONS
This respirator contains a system for synchronizing with your breathing and regulating mask pressure. This system should be recalibrated if it experiences a change in temperature of more than 36°F (20°C), a change in altitude of more than 328ft (100m) or before using the respirator for the first time. It is best practice to also recalibrate if the unit has been in storage, particularly if the storage temperature is not known.
For the most accurate battery charge indication, the respirator must be plugged into its charger and the charger must be plugged into a power source. Wait for all three (3) Battery Charge Indicators to light solidly without flashing. If the third Battery Charge Indicator is flashing rapidly, the battery is 95% charged.
If the Power Unit stops, leave the contaminated area. If the user encounters breathing difficulty the respirator should be doffed.
After doffing, the user should leave the contaminated area immediately.
1.5. RESPIRATOR PROGRAM MANAGEMENT
Occupational use of respirators must be in compliance with applicable health and safety standards. Before occupational use of this respirator, a written respiratory protection program must be implemented meeting all the local government requirements. In the United States, employers must comply with OSHA 29 CFR 1910.134 which includes medical evaluation, training, and fit testing. Employers must also meet the requirements of Standard Practice for Respiratory Protection ASTM F3387 and any applicable OSHA substance specific standards. For additional information on this contact OSHA at www.OSHA.gov. In Canada, CSA standard Z94.4 requirements and/or the requirements of the applicable jurisdiction must be met. Contact an industrial hygienist or CleanSpace Technical Service with questions concerning the applicability of the respirator to your job requirements.

System Description

CleanSpace PRO is a complete NIOSH approved respiratory protection system (“respirator”). When used in accordance with its NIOSH approval, the respirator helps reduce exposure to certain particulates. CleanSpace PRO does not provide protection against vapors or gases. See NIOSH Cautions and Limitations and the Approval Labels for CleanSpace PRO for additional information on approvals. CleanSpace Respirators are Powered Air Purifying Respirators (PAPRs) which means that they draw ambient air through the filter using a fan and supply the filtered air to the wearer via the mask. The fan produces enough flow to ensure that the pressure inside the mask is positive, which helps to provide a high level of protection to the user. CleanSpace Respirators are breath responsive, which means that they provide more flow during inhalation and less flow during exhalation whilst maintaining positive pressure in the mask. The components approved for use in the CleanSpace PRO respiratory system are shown below in Section 2.1.
Properly selected, used and maintained respirators help to protect against certain airborne contaminants. It is essential to follow all instructions and government regulations on the use of this product in order for the product to help protect the wearer. Misuse of respirators may result in overexposure to contaminants and lead to sickness. For proper use, consult an Occupational Health Specialist, these User Instructions or contact CleanSpace Technology Customer Support on [email protected] or the website: cleanspacetechology.com.
2.1. SYSTEM COMPONENTS
Throughout these User Instructions, reference is made to various commonly used components and features of the respirator.
Familiarize yourself with these parts before reading the rest of the User Instructions. For a list of components and their respective part numbers refer to Section 7.

CleanSpace C5T1001 Pro Respirators - fig1

A. Mask AirClip
B. Mask Release Button
C. Power Unit AirClip
D. Bellow
E. Adjust Button
F. Filter Release Button
G. Power Unit Hoop

2.2. CONTROLS AND INDICATORS
2.2.1 KEYPAD
A keypad is located on the top of the Power Unit. It contains all controls and indicators.

CleanSpace C5T1001 Pro Respirators - fig2

2.2.2 POWER BUTTON
The Power Button is used to switch the operating mode of the CleanSpace Respirator. There are three operating modes.
OFF Mode
The CleanSpace Respirator is unpowered.
The Battery Charge Indicator is not illuminated.
There is no airflow to the mask.
In OFF Mode, pressing the Power Button once will switch the CleanSpace Respirator to STANDBY Mode.
Note: The Power Button cannot be used to switch the Power Unit to OFF Mode.
STANDBY Mode
The CleanSpace Respirator is actively monitoring and ready to deliver filtered air to the mask with any pressure change.
The Battery Charge Indicator displays battery charge.
There is no airflow to the mask.
In STANDBY Mode, if breathing is detected the CleanSpace Respirator will automatically switch to ON Mode.
In STANDBY Mode, if no breathing is detected for 3 minutes, the CleanSpace Respirator will switch to OFF Mode. This conserves battery life.
Note: From STANDBY Mode, pressing the Power Button will switch the system to ON Mode. This is not normal procedure.
ON Mode
The CleanSpace Respirator is actively monitoring and delivering filtered air to the mask.
The Battery Charge Indicator displays battery charge.
The blue On Light is illuminated, indicating the Power Unit is in ON Mode.
In ON Mode, if no breathing is detected within 5 seconds, the CleanSpace Respirator will automatically switch to STANDBY Mode. This conserves battery life when not being worn.
CleanSpace Respirators can only switch to ON Mode from STANDBY Mode.
2.2.3 BATTERY CHARGE INDICATOR
A Battery Charge Indicator is located on the keypad of all CleanSpace Respirators. It is comprised of three green lights. The battery is fully charged when the charger is connected to the Power Unit and all three lights are solid green. The battery charge and approximate useful time remaining when the CleanSpace Respirator is NOT on charge are shown below.

Battery Charge Indicator| Battery Charge (%)| Approximate Useful Time Remaining (hrs)*
---|---|---
3 Green Solid Lights| 80 — 100 %| Up to 14 hours
2 Green Solid Lights| 50 — 80 %| 6 —10 hours
1 Green Solid Light| 20 — 50 %| 2 — 6 hours
1 Green Flashing Light| 5 — 20 %| < 2 hours
1 Green Flashing Light andLow Battery Alarm| < 5 %| < 15 minutes (Leave contaminated area immediately)
Unpowered| 0%| 0 minutes
(Do not use. Recharge)

*Operating time is strongly affected by filter type, filter loading, mask seal, work rate, altitude, and other factors. The operating times quoted above are average durations at moderate work rates at sea level. Actual operating times may vary widely from the quoted average durations.
2.2.4 FLOW TEST BUTTON
The Flow Test measures the rate of flow produced by the CleanSpace Respirator to ensure it can deliver a minimum design flow of 120 l/min. When CleanSpace Respirators are in STANDBY Mode, pressing the Flow Test Button initiates the Flow Test. Refer to Section 3.4 for instructions on running the flow test.
2.3. ALARMS
2.3.1 FILTER CHANGE ALERT
The Filter Change Alert:

  • Is triggered when the filter exceeds service limits and needs to be changed.
  •  Consists of a repeated aural alert of two beeps per second and a red flashing Filter Alarm Light.
  • Can be muted by pressing the Power or Flow Test Button once. Unless the filter is changed, the alert will resume when the CleanSpace Respirator next switches to STANDBY Mode.
  •  If the Filter Change Alert is triggered but the filter is still new, make sure the operating altitude is set correctly. The operating altitude can be set by either recalibrating the Power Unit or by using the CleanSpace Smart App.

If the Filter Change Alert is triggered, the filter has exceeded service limits and should be changed.
Using a filter that has exceeded service limits can cause the flow to fall below the minimum design flow.
This may result in overexposure to contaminants and lead to sickness.

2.3.2 LOW BATTERY ALARM
The Low Battery Alarm:

  • Is triggered when the battery charge decreases below the level at which it may be able to supply the minimum design flow of 120 l/min.
  • Consists of a repeated aural alert of three beeps per second and one green flashing Battery Charge Indicator light.
  • Cannot be muted.

If the Low Battery Alarm is triggered, you must leave the contaminated area IMMEDIATELY and recharge the battery.
Using the respirator after the Low Battery Alarm has triggered can cause the flow to fall below the minimum design flow. This may result in overexposure to contaminants and lead to sickness.

2.3.3 FILTER ABSENT ALARM
The Filter Absent Alarm:

  • Is triggered when the respirator is in ON Mode and it detects that there is no filter present.
  • Consists of a continuous aural alert and a red flashing Filter Alarm Light.
  •  Can be muted by pressing the Power or Flow Test Button once. Unless a filter is inserted, the alarm will resume in one minute.

If the Filter Absent Alarm is triggered, you must install a filter before entering the contaminated area.
Using the respirator without a filter installed will provide no respiratory protection. This may result in overexposure to contaminants and lead to sickness.
2.4. BATTERY
CleanSpace Respirators have an internal lithium ion (Li-ion) battery. Lithium ion (Li-ion) batteries have the highest energy density of all battery types and are widely used in portable electronic devices. CleanSpace Respirators use quality Li-ion batteries and are designed to be viable over a minimum of 500 complete charge and discharge cycles while still maintaining at least 70% of their specified full capacity. For detailed battery information refer to the Product Information section of the CleanSpace website
cleanspacetechnology.com.

2.4.1 BATTERY PRECAUTIONS
The following precautions must be followed during use:

  • Avoid mechanical shocks or impacts from any sharp or hard objects.
  • Do not use the respirator if there are any signs of severe mechanical damage.
  • Do not use or place the respirator in extreme heat, such as in direct sunlight, near heat sources, etc. The battery will be damaged if its temperature rises above 158°F (70°C). The respirator will stop functioning if its internal temperature rises above 140°F (60°C) or falls below 14°F (-10°C). Do not use, charge or store the device outside the recommended temperature limits.
  • Do not dispose of the respirator in a fire.
  • Do not use the respirator in heavy rain or allow it to get wet or immersed in liquid.
  • Do not disassemble the Power Unit case. Disassembly will void the Manufacturer’s Warranty. There are no user serviceable parts inside.

Always correctly use and maintain the internal lithium-ion battery packs. Failure to do so may result in fire or explosion, or could adversely affect respirator performance and result in injury, sickness or death.
CleanSpace PRO is not intrinsically safe. Do not use in flammable or explosive atmospheres. Doing so may result in injury or death.
In the extremely rare circumstance that the battery is damaged and electrolyte comes in contact with eyes, flush with water immediately and seek urgent medical attention.

2.4.2 CHARGING THE BATTERY
The battery can only be charged at temperatures between 32°F and 95°F (0°C and 35°C), should not be charged in electromagnetic environments (such as near welding machines) and should not be worn while being charged. To charge the battery.

  1. Locate the charging port on the underside of the Power Unit.
  2. Ensure the Universal Charger is plugged into a power source.
  3.  Insert the charger cable connector into the charging port.
  4. Charging is indicated by at least one green flashing light on the Battery Charge Indicator.
  5. When fully charged, three green solid lights will display on the Battery Charge Indicator.
  6. If the third green Battery Charge Indicator light is flashing rapidly, charging is 95% complete.
  7. When the Power Unit is charged, disconnect the charger cable from the charging port.

IMPORTANT: To ensure the battery is 100% charged, ensure the charger is connected to the Power Unit and the Battery Charge Indicator lights all turn on solid green (no flashing).
The battery shall only be charged in non-hazardous areas. Move out of the hazardous area before charging. The Power Unit must not be placed on charge in enclosed cabinets without ventilation, near flammable liquids or gases or near heat sources. Do not use, charge or store the device outside the recommended temperature limits.
CleanSpace Respirators use a unique charger. Do not attempt to charge your CleanSpace Respirator with any other charger.

2.5. FILTERS
2.5.1 FILTER PRECAUTIONS
The following precautions must be followed during use:

  • Always change the filter outside of the contaminated area and with the respirator doffed.
  •  CleanSpace filter media cannot be cleaned. Cleaning the filter media may cause damage. The filter media is contained within a filter case. The filter case may be wiped with a dry cloth free of chemicals.
  • Used filters should be disposed of responsibly and treated as non-recyclable hazardous waste (dependent on the contaminant being filtered).
  • Change the filter if it is damaged or there is suspected damage.
  • Filters should be changed regularly. The frequency of filter replacement depends on several factors: period of use,  concentration of airborne contaminants, exertion levels and workplace protocols where hazards present a risk for cross contamination (e.g. biohazards).

Do not use compressed air or a brush to clean the filter. HEPA filters are very easily damaged by using compressed air or by brushing. Misuse of CleanSpace Respirators by cleaning the filter may result in overexposure to contaminants and lead to sickness.
It is essential that the correct filter type is selected for the chosen application.
Use only NIOSH-approved CleanSpace filters. If used with other filters CleanSpace Respirators are not NIOSH approved. Use of other filters may result in overexposure to contaminants and lead to sickness.
2.5.2 CHANGING THE FILTER
Change the filter when:

  • The Filter Change Alert triggers – audible (2 beeps per second) and visual (red Filter Alarm Light flashes).
  • The Filter Absent Alarm triggers but there is a filter in place.
  • The battery is fully charged and the operating altitude is set correctly, but the Flow Test indicates that the respirator is not able to produce the minimum design flow of 120 l/min.
  • The filter has been exposed to water or other liquids.
  • The outside of the filter case is heavily soiled.
  • There is any sign of damage or suspected damage to the filter.
  • The filter reaches its expiry date. The expiry date is marked on the filter label.
  •  There are signs of dust or contaminants on the inside surface of the filter.

A CleanSpace Respirator with a clean filter will run for much longer than one with a filter that contains dust contaminants. To maximize your work time between battery charges, change the filter often in high dust environments.
To remove a used filter, simply press down on either Filter Release Button (refer to Section 2.1) and the filter will be released.
To install a new filter, align the filter so that the ‘CleanSpace’ text faces up (in the same direction as the keypad) and push the filter towards the Power Unit until you hear a click. The filter should be seated securely in place.

CleanSpace C5T1001 Pro Respirators - fig4

Before Donning the CleanSpace Respirator

3.1. CLEANSPACE RESPIRATOR FIT
3.1.1 MASK SELECTION AND FIT
Before using your CleanSpace Respirator, you must determine the right mask for your face and know how to adjust the system to achieve a good fit. It is vital that your mask is the right size for your face and fits properly. Mask fit must be confirmed with a fit test performed by a specialist / designated mask fitter according to OSHA regulations 1910.134; however the information below will help your mask fitting specialist to select the mask most likely to fit you and may therefore save time. The ‘Face Width’ and ‘Face Length’ of a user are defined by the images below.

CleanSpace C5T1001 Pro Respirators - fig5

Use the table below to determine which CleanSpace Half Mask is likely to provide the best fit for your face.

CleanSpace C5T1001 Pro Respirators - fig6

*If the medium mask fails initially, the mask fitting specialist will determine whether to try the small or the large mask next.
3.1.2 NECK SUPPORT SELECTION AND FIT
Your CleanSpace Respirator is supplied with two sizes of Neck Support – Small (“S”) and Medium (“M”). “S” is for people with smaller necks and heads while “M” is for those with medium sized heads and necks. Users for whom the “M” Neck Support does not provide enough room (both bellows are fully extended but mask is still too tight on face) should use the respirator without a Neck Support. This configuration provides extra room and is comfortable due to the curved design of the case. As a general rule, use the smallest size Neck Support that is comfortable.
Half Mask System
Selecting the right size of Neck Support is vital to achieving a good Half Mask fit. With the correct sized Neck Support, the Half Mask should achieve a good seal without using up all the travel in the respirator’s bellow adjustment system. This gives an opportunity to adjust the respirator further for increased comfort and freedom of movement.
3.1.3 HARNESS FIT
The Harness is a required component when using the CleanSpace Respirator Half Mask System. It is used to support the weight of the Power Unit and to ensure a good, comfortable fit. The Harness has a rear strap that can be adjusted by the user to fit a variety of different head sizes. Users with a larger head should use the hole which ‘elongates’ the rear strap (left-hand arrow in the image below) while users with smaller heads should use the hole which ‘shortens’ the rear strap (right-hand arrow in the image below). When fitted correctly, the Harness should sit comfortable on the crown of the head.

3.1.4 FIT TESTING
Fit testing must be carried out by a specialist / designated mask fitter. The fit must be confirmed by a fit test performed according to OSHA regulations 1910.134. A fit test must be performed during initial selection of a respirator, or whenever the user’s face changes shape (for instance due to weight gain or loss) and at least annually. Refer to OSHA regulations 1910.134, or our product resource section at cleanspacetechnology.com for more information on fit testing requirements.
CleanSpace recommends fit testing in ON Mode (i.e. with the device operating as it will in the contaminated area). Entering or remaining in the contaminated area with the respirator in OFF Mode is considered non-normal operation.
If a satisfactory quantitative fit factor or passing qualitative test cannot be achieved with any of the masks, the CleanSpace Respirator must not be used.

3.2. PRE-USE INSPECTION
Before each entry into a contaminated area, carry out a visual inspection of all components of your CleanSpace Respirator system. If parts are missing or damaged replace them only with approved parts before proceeding.

  • Check the POWER UNIT for cracks, holes or other damage or missing parts. Do not use the device if there is any damage or misuse. Check both bellows for splits or holes. Check that the bellows have not become distorted as this may obstruct the air supply to the mask. Check the Neck Support (if required). Check that the battery has sufficient charge to complete the work period by pressing the Power Button. The Battery Charge Indicator light(s) will illuminate to indicate the approximate charge. A full charge is recommended.
  • Check the FILTER carefully. The filter seal must be clean and free from damage of any kind. Examine the visible internal surfaces for any sign that dust has penetrated the media. If dust is found, do not use the filter. The body of the filter must be free of cracks or signs of damage. If any sign of impact or scratching is found, discard the filter. Fit the filter to the respirator (refer to Section 2.5).
  • Check the MASK to ensure that there are no cracks, tears, dirt or distortion. Check the mask exhalation valve for damage or dirt build up. If it is dirty, remove any dirt, hairs or anything that could affect the seal of the valve against its seat. Check that the valve seat is clean. If the valve is damaged, replace it.
  • Check the HARNESS is intact, is not frayed or damaged and has good elasticity.

3.3. RECALIBRATION
This respirator contains a system for synchronizing with your breathing, regulating mask pressure and updating the operating altitude of the Power Unit. This system should be recalibrated if it experiences a change in temperature of more than 36°F (20°C), a change in altitude of more than 328ft (100m) or before using the respirator for the first time. It is best practice to also recalibrate if the unit has been in storage and the storage temperature is not known. Steps to recalibrate:

  1.  Remove the filter and mask (if fitted) from the Power Unit.
  2. With the respirator in STANDBY Mode (i.e. one or more Battery Charge Indicator lights on), press the Power Button and the Flow Test Button on the keypad at the same time.
  3.  When both the blue On Light and the red Filter Alarm Light illuminate, release both buttons.
  4. Do not touch or move the respirator during the recalibration process.
  5. After 5 seconds, the Power Unit will run and air will blow from the left-hand bellow.
  6. When the airflow stops, recalibration is complete, and the Battery Charge Indicators will return to indicating battery charge status.
  7.  Refit the filter to the Power Unit.

You must recalibrate the internal pressure sensor any time that your CleanSpace Respirator is exposed to changes in temperature of more than 36°F (20°C), changes in altitude of more than 328ft (100m) or before using the respirator for the first time. It is best practice to also recalibrate if the unit has been in storage, particularly if the storage temperature is not known.
3.4. FLOW TEST
The Flow Test checks that the CleanSpace Respirator can deliver a minimum flow of 120 l/min. This test should be completed before each entry into a contaminated area.
3.4.1 FLOW TEST PROCEDURE

  1. Leave the filter in place.
  2.  Place the respirator flat on a table or other support.
  3. Ensure the Power Unit is in STANDBY Mode (press the Power Button once if not). Press and release the Flow Test Button.
  4. The respirator will automatically run the Flow Test. During the test, air will flow from the left-hand bellow.
  5. After 2 seconds the respirator reports the test result using the Battery Charge Indicator lights on the keypad. Use the table below to interpret the indicators.
Flow Test Result Meaning Note
3 Solid Green Lights PASS Excellent (Flow > 1801/min)

result will display for a few seconds.
Power Unit will then switch to OFF Mode.
2 Solid Green Lights| PASS| Good
1 Solid Green Light| PASS| Acceptable
1 Red Flashing Filter Alarm Light & 3 Flashing Green Lights| FAIL| Fail
(Flow < 1201/min)| Reset by pressing the Power Button once.
Power Unit will then switch to STANDBY Mode.

3.4.2 FAILED FLOW TEST
Do not use the respirator until a new filter has been fitted and/or the battery has been fully charged and the test has been repeated with a PASS result. If the respirator fails the test but the filter is new and the battery is fully charged, make sure the operating altitude is set correctly. The operating altitude can be set by either recalibrating the Power Unit or by using the CleanSpace Smart App. If the respirator continues to fail the flow test, contact CleanSpace Technology and do not use the respirator until it has been evaluated.
Important: The Flow Test is not a battery charge test. Three Battery Charge Indicator lights means that, at the moment it is tested, the unit can deliver high flow. It does not mean the battery is fully charged. Check the battery charge separately. Refer to Section 2.2.3.

Donning the Half Mask CleanSpace Respirator

Locate your Power Unit, Half Mask, Neck Support and Harness. Make sure the Half Mask, Neck Support (if required) and Harness are the same size or setting that you used for your last successful fit test. Ensure a clean filter is fitted to the Power Unit.
Important: Read through this entire chapter before beginning to don the CleanSpace Respirator.
STEP 1 – FIT THE NECK SUPPORT TO THE POWER UNIT
The Neck Support has circular openings at each end which snap over buttons on the Power Unit case. Position the Neck Support in place against the buttons and then press firmly until the Neck Support clips securely into place.

CleanSpace C5T1001 Pro Respirators - fig8

STEP 2 – FIT THE HARNESS TO THE HALF MASK
Connect the two side straps of the Harness to the circular clips located on the inside of the mask, ensuring that the harness strap with the front marker is facing forwards. Loosen the side straps as far as they will travel.

CleanSpace C5T1001 Pro Respirators - fig9

STEP 3 – FIT THE HALF MASK TO THE POWER UNIT
Ensure that the peak of the mask and the keypad on the Power Unit are both facing up. Bring the right-hand side of the Mask and Power Unit together until the AirClips click into place. Loosen the bellows as far as they will go by pressing the Adjust Buttons on each side of the Power Unit whilst gently extending the bellows away from the Power Unit.

CleanSpace C5T1001 Pro Respirators - fig10

STEP 4 – SWITCH THE POWER UNIT TO STANDBY MODE
Press the Power Button once to switch the Power Unit to STANDBY Mode from OFF Mode. The Battery Charge Indicator should display the level of charge. The respirator should be fully charged before use.

CleanSpace C5T1001 Pro Respirators - fig11

STEP 5 – DON THE RESPIRATOR
To don the respirator:

  1. Drape the Power Unit around the back of the neck and connect the left-hand side of the Mask and Power Unit until the AirClips click into place.
  2.  Lift the mask onto your face and pull the Harness upwards and over the face until it sits comfortably on the crown of your head.
  3. Breathe in, the Power Unit will automatically switch to ON Mode. If it doesn’t, check that the respirator is in STANDBY Mode.
  4. Locate the rear harness hook and clip it securely to the Power Unit Hoop.

CleanSpace C5T1001 Pro Respirators - fig12

STEP 6 – ADJUST THE RESPIRATOR
If required, the CleanSpace Respirator can be adjusted after donning by either tightening the bellows or tightening the Harness.

  1. Tighten the bellows by placing one hand on the back of the Power Unit and one hand over the front of the mask. Push the Power Unit forwards and the mask backwards, tightening the fit. Ensure bellow adjustments are symmetrical. If the mask is too tight, loosen the bellows by pressing the Adjust Buttons.
  2. Tighten the Harness by pulling the side straps downwards. The Harness can also be loosened if required by lifting the ratchet clips upwards and pulling the base of the side straps downwards.
  3. Tighten the rear hook by pulling upwards on the back strap. The respirator should sit evenly and level.

CleanSpace C5T1001 Pro Respirators - fig13

STEP 7 – COMPLETE A USER SEAL CHECK
The User Seal Check is an OSHA requirement and is used to ensure that an adequate seal is achieved each time the respirator is donned. There are two ways to complete a seal check with your CleanSpace Respirator.
OPTION 1 – NEGATIVE PRESSURE SEAL CHECK
Please note – due to changes in pressure, the Power Unit may switch between modes and the air may blow during this process.
This is normal and will not affect the seal check.

  1. Unclip the left-hand AirClip while holding the Power Unit close to your head with your right hand.
  2.  Block the left-hand mask air inlet with your thumb.
  3. Breathe in. You should not be able to draw any air into the mask. The mask should collapse inwards as you inhale, with no leaks. Listen for any squeaking or whistling noises which may indicate that air is leaking past the seal.
  4. Hold your breath for approximately 5 seconds. The mask should stay collapsed against your face. If the mask seal slowly recovers (mask moves away from your face) there is a leak.
  5.  If there is a leak, readjust the mask, confirm the left-hand mask air inlet is completely blocked and repeat the seal check until no leakage is observed.
  6.  After passing the seal check, reconnect the left-hand side of the mask and Power Unit, ensuring the AirClips click into place. Once reconnected, the respirator will either
    a) Automatically switch to ON Mode.
    b) If it is already in ON Mode, it will continue to operate as required.

OPTION 2 – POSITIVE PRESSURE SEAL CHECK

  1. Clip the Seal Check Cap (PAF-0058) onto the valve of the mask. Ensure that that no air is flowing from the valve.
  2. Tilt your head in each direction and use your fingers to feel around the perimeter of the mask for leaks. For extra sensitivity, breathe out firmly to increase the mask pressure and wet your fingers (easier to detect leaks).
  3. If there is a leak, readjust the mask and repeat the seal check until no leakage is observed.
  4. After passing the seal check, remove the Seal Check Cap by gently twisting the handle so that one side of the cap comes loose from the exhalation valve. Be careful not the dislodge the exhalation valve cover.

CleanSpace C5T1001 Pro Respirators - fig14

Be sure to remove the Seal Check Cap before entering the contaminated area. The cap blocks the exhalation valve, making it more difficult for your exhaled air to be expelled from the mask. Failure to remove the cap will lead to increased levels of rebreathed Carbon Dioxide and may result in headache or dizziness. Never leave the cap in place for more than 2 minutes.
If a satisfactory seal check cannot be achieved, do not enter the contaminated area.

The Contaminated Area

5.1. HUMAN FACTOR CONSIDERATIONS
5.1.1 NOISY ENVIRONMENTS
In most noisy environments, the respirator alarms are still clearly audible to the user. However, if there is a chance you will not hear them, you must take the following extra precautions.

  • Do not enter the contaminated area unless all three (3) green Battery Charge Indicator lights are illuminated.

  • Do not work in a high noise area for more than four (4) hours. At the end of four (4) hours, leave the contaminated area and check;
    – the Filter Alarm Light is not illuminated; AND
    – all three (3) green Battery Charge Indicator lights are still illuminated.

  •  If two (2) or fewer green Battery Charge Indicator lights are illuminated, recharge the CleanSpace Respirator until three (3) solid green lights are displayed.

  •  If the red Filter Alarm Light is illuminated, change the filter.

  • Be particularly aware of difficulty breathing or of the powered airflow stopping. If either of these things occur, exit the contaminated area immediately.

5.1.2 COMMUNICATION
The following recommendations are suggested to aid communication whilst wearing a CleanSpace Respirator.

  • Speak 30% louder in volume.
  •  Truncate sentences – shorten communication to ensure it is clear and concise.
  • Use closed loop communication – exchange information, acknowledge receipt of that information and confirm the recipient has interpreted the information correctly.

5.2. ENTERING THE CONTAMINATED AREA
Prior to entering the contaminated area, complete the inspections and checks listed in these User Instructions.

  • Ensure a User Seal Check has been completed and the motor is responding to your breathing.
  • Familiarize yourself with the Adjust Buttons and the Mask Release Buttons.
  • Check no alarms are sounding or flashing. If your work environment is noisy, you may be unable to hear the alarms. In this case you must follow the special precautions set out in Section 5.1.
  • If additional PPE is required, ensure this is donned also.
  • Enter the contaminated area.

If the Power Unit stops or the user encounters difficulty with the respirator, leave the contaminated area.
If you have an acute or spontaneous health episode (i.e. experiencing dizziness) and believe removing the respirator while you leave the contaminated area may help, remove the respirator and leave the contaminated area immediately.
5.3. EXITING THE CONTAMINATED AREA
Leave the contaminated area immediately if any of the following conditions occur:

  •  The Filter Change Alert, Low Battery Alarm or the Filter Absent Alarm triggers.
  • Any part of the system becomes damaged.
  • Airflow into the mask decreases or stops.
  • Breathing becomes difficult.
  •  You feel dizzy or your vision is impaired.
  • You smell or taste contaminants.
  • Your face, eyes, nose or mouth experience irritation.
  • You suspect the concentration of environmental contaminants has reached levels at which this respirator may no longer provide protection.
  • Oxygen/carbon dioxide levels change such that PAPRs should no longer be worn.

Follow the exiting and decontamination procedures as documented in the workplace Respiratory Protection Program. Follow those procedures with the instructions below when removing the respirator.
5.4. DOFFING THE HALF MASK RESPIRATOR
To doff the Half Mask CleanSpace Respirator:

  1. Unclip the rear hook of the Harness from the Power Unit Hoop.
  2. Slide the Harness forward over your head, toward the nose of the mask.
  3. Locate one of the Mask Release Buttons on either side of the respirator.
  4. Press the button and gently pull the Power Unit away from the mask.
  5. Remove the respirator from your face.

After the Power Unit is removed, the air will continue to blow for approximately 5 seconds before automatically switching to STANDBY Mode when no breathing is detected. There is no need to turn the respirator off, after three (3) minutes in STANDBY Mode, the respirator will automatically switch to OFF Mode.

CleanSpace C5T1001 Pro Respirators - fig15

Care and Cleaning

6.1. CLEANING
We recommend that you clean your respirator after every use. CleanSpace Respirator components should be cleaned separately.
Determine the method most appropriate to your cleaning requirements. If using a wipe, refer to the Compatible Cleaning and Disinfecting Agents Supplement available from CleanSpace Technology at cleanspacetechnology.com.
Important: The methods to clean the equipment (outlined below) are not a disinfection or sterilization protocol. If disinfection or sterilization is required, contact CleanSpace Customer Service at [email protected].
6.1.1 HALF MASK
Determine the method most appropriate to your cleaning requirements. If using a wipe, refer to the chemical agent and disinfectant supplement information available from CleanSpace Technology.
If washing the Half Mask, remove the valve cover. To do this, locate the snap feature on the cover that secures it to the valve seat. This feature is located on the bottom edge of the valve seat. Using your thumb nail or a small blunt object such as a pen, press on the snap until the cover springs free of the valve seat as shown in the image below. Then, wash the mask (including the exhalation valve leaf and cover) thoroughly with a mild detergent in warm water (less than 122°F (50°C)). Rinse well in warm running water to ensure any residue from the cleaning solution has been removed.

CleanSpace C5T1001 Pro Respirators - fig16

After cleaning, allow the mask to air dry in a clean environment (valve up to prevent pooling) or hand dry with a clean, lint-free cloth. Do not dry the mask by exposing directly to heat. Before use, ensure that the exhalation valve leaf is properly seated against the valve body and operates freely. Reinstall the valve cover. Visually check the valve leaf again after the cover has been installed to ensure the valve leaf is completely sealed against the valve body.
Never dry the mask or exhalation valve with a cloth that may leave behind lint. Lint contamination of the exhalation valve may cause it to leak, resulting in overexposure to contaminants and lead to sickness.
6.1.2 POWER UNIT
Use cleaning wipes or a cloth dampened with cleaning agent to wipe down the outside of the Power Unit. After cleaning, use a clean cloth to remove any residue from the cleaning agent. Allow the Power Unit to air dry in a clean environment or dry the Power Unit using use a clean, lint-free cloth.
Using a Cleaning and Storage Plug, higher level cleaning is available for the Power Unit. Please visit the resources section of the CleanSpace website for more information at cleanspacetechnology.com.
CleanSpace Power Units contain a battery, sensitive electronics, and a motor. NEVER immerse the Power Unit in water.

6.1.3 FILTER
CleanSpace particulate filter media cannot be cleaned. The filter media is contained within a filter case. Dispose of the filter responsibly when a change is required. Refer to Section 2.5 for more information.
6.1.4 HARNESS AND NECK SUPPORT
The Harness and Neck Supports can be cleaned using the method described for the CleanSpace Masks.
6.2. STORAGE
The respirator and additional components should be stored under the following conditions when not being used.

  • Relative Humidity: 0% to 75%.
  • Temperature: 50°F to 86°F (10°C to 30°C) Out of direct sunlight, in a clean, dry environment.

6.3. RECALIBRATION
This respirator contains a system for synchronizing with your breathing and regulating mask pressure. This system should be recalibrated if it experiences a change in temperature of more than 36°F (20°C), a change in altitude of more than 328ft (100m) or before using the respirator for the first time. It is best practice to also recalibrate if the unit has been in storage, particularly if the storage temperature is not known. Refer to Section 3.3 for the recalibration procedure.
6.4. SERVICING
It is the purchaser’s responsibility to ensure that CleanSpace respirators and components are regularly maintained to an operational standard. CleanSpace recommends annual servicing of CleanSpace respirators by an accredited CleanSpace technician. For more information go to cleanspacetechnology.com.

List of Components

Type Description Product Code
Power System Power System — CST PRO CST1001
Power Unit Power Unit — CST PRO CST1002
Mask Half Mask — Small CST1014
Half Mask — Medium CST1015
Half Mask — Large CST1016
Half Mask with Harness—Small CST1034
Half Mask with Harness — Medium CST1035
Half Mask with Harness — Large CST1036
Filter Filter HE — High Capacity CST1004
Neck Support Neck Support — Small CST1019
Neck Support — Medium CST1020
Harness Harness CST1021
Accessories Universal Charger PAF-1100
Seal Check Cap PAF-1009

For information on the full range of available products, please refer to the CleanSpace website at cleanspacetechnology.com.

Specifications

Operation

Weights| System: 600g (Power Unit, filter, Half Mask (M), Neck Support (M), Harness). Half Masks (with Harness): 145g to 175g.
Harness: 30g.
Air Flow (Breath Responsive)| Minimum: 120 l/min, Maximum: 230 L/min.
Dependent on filter type, filter loading, altitude and battery condition.
Operating Temperature Range| Minimum: 14°F (-10°C), Maximum: 113°F (45°C).
The CleanSpace Respirator will shut down when battery temperature is greater than 140°F (60°C) or less than 14°F (-10°C).
Operating Humidity Range| Zero to 90%, non-condensing.
Operating Altitude Range| Minimum: Approx. -3280 ft (-1000m), Maximum: Approx. 13780 ft (4200m).
Operating Run Time| Up to approximately 14 hours.
Run time is strongly influenced by filter type, filter loading, mask seal, work rate, altitude and other factors. Run times may vary widely.
Battery
Charger| Input: 100 — 240VAC, 50 — 60 Hz. Output: 14.7 VDC, 24 Watts
Charging Temperature Limits| 32°F to 95°F (0°C to 35°C).
The battery will not accept charge outside of this range.
Optimal Storage Conditions| 50°F to 86°F (10°C to 30°C) & 0% to 75% relative humidity. Out of direct sunlight, in a clean, dry environment.
Battery (Type/Capacity)| Lithium-Ion — 11.1V, 1850 mAh, 20.54Wh.
Recharge Time| 2 hours (to 95%).
Alarms & Alerts
Filter Change Alert| Triggers when the filter has exceeded service limits and needs to be changed. Audible alert: 2 beeps repeated every second, 75dB(A) at ear.
Visual alert: Red Filter Alarm Light flashes.
Low Battery Alarm| Triggers when the remaining operating time is approximately 15 minutes. Audible alarm: 3 beeps, repeated every second, 75dB(A) at ear.
Visual alarm: Single green Battery Charge Indicator light flashes.
Filter Absent Alarm| Triggers when the respirator detects that there is no filter present. Audible alarm: Constant, continuous beep, 75dB(A) at ear.
Visual alarm: Red Filter Alarm Light flashes.

Warranty

This product has been manufactured using quality parts and processes. CleanSpace Technology Pty Ltd warrants that the product is free from defective workmanship and parts for a period of two (2) years from the date of original purchase provided the product has been used, cleaned and maintained in accordance with these instructions and CleanSpace Technology’s recommendations. This warranty does not include consumable parts, such as filters and face masks, which must be replaced regularly by the user. Consumable parts are warranted up to the point of use, provided they have been stored correctly and are within their expiry date.
This warranty does not cover:

  • Where the product has been used for industrial purposes outside the recommendations of CleanSpace Technology Pty Ltd;
  • Where damage has been caused by misuse, neglect, accident, or excessive wear and tear.

Any claim under this warranty must be made within two (2) years of the date of purchase of the product. All warranty claims must be made by returning the defective product to your supplier together with the proof of purchase. The purchaser is responsible for all freight. In the event that any part of the product is found by CleanSpace Technology to be defective, CleanSpace Technology will either repair or at its discretion replace the faulty part.
This warranty is given by:

CleanSpace Technology Pty Ltd
ABN 24 146 453 554,
Unit 5. 39 Herbert Street
St. Leonards, NSW 2065 Australia;
T: +61 2 8436 4000
E: [email protected]

This warranty is provided in addition to other rights and remedies you have under law. You are entitled to replacement or refund for a major failure. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Disclaimer:
Whilst CleanSpace Technology has made every effort to ensure that the details and information given in both our printed and online publications are accurate at the time of issue, full technical specifications are not necessarily included. Furthermore, CleanSpace Technology has a policy of continuous improvement and the right is reserved to alter details and information as the need arises. Accordingly, the Customer should check any details and information they wish to rely on with CleanSpace Technology at the time of purchase. CleanSpace Technology cannot accept liability in respect of any errors or omissions herein contained or for any loss or damage malfunction or consequential loss arising from reliance upon our publication. The Customer will be responsible for any risk to health or safety from goods in the Customer’s possession and/or control. The Customer’s attention is drawn to the fact that statutory regulations and recognized codes of practice exist covering the use and handling of some goods (including safety products). The Customer must ensure that persons who use the goods receive adequate training and safety literature.

©2023 CleanSpace Technology Pty Ltd. All rights reserved.
No page or part of these User Instructions may be reproduced in any form without written permission of the copyright owner shown above. CleanSpace Technology reserves the right to correct typographical errors. All information is correct at the time of going to print.
S008-7014 Rev 2, 10th July 2023
Released on Change Note ECN2059

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

CleanSpace User Manuals

Related Manuals