verve 5059340251165 Water Meter Counter Instruction Manual
- June 12, 2024
- Verve
Table of Contents
- verve 5059340251165 Water Meter Counter
- Product Information
- Product Usage Instructions
- Before you start
- Technical data
- Product Description
- General Instructions
- Intended use
- Safety
- Starting up
- Operation
- Description of functions
- Setting of displayed parameters
- Maintenance
- Storage
- Disposal
- Troubleshooting
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
verve 5059340251165 Water Meter Counter
Product Information
The product code is V21222_5059340251165_MAND1_2223. This product is available on the website www.screwfix.fr.
Product Usage Instructions
- Before using the product, ensure that you have read and understood the user manual provided.
- Make sure to wear appropriate protective gear such as gloves and safety goggles before using the product.
- Inspect the product for any visible damage before use. Do not use if the product appears to be faulty or damaged.
- Ensure that the product is compatible with the task or application you intend to use it for.
- Follow the specific instructions provided in the user manual regarding the setup and operation of the product.
- Always use the product in a well-ventilated area to avoid inhaling any fumes or harmful substances.
- Do not exceed the recommended usage limits or apply excessive force when using the product.
- When not in use, store the product in a safe and dry place away from children and pets.
- Regularly clean and maintain the product according to the instructions provided in the user manual.
- If you experience any issues or have any questions about the product, refer to the troubleshooting section in the user manual or contact our customer support.
Before you start
Intended use: water flow measurement. Application: for domestic use. Place of installation: any. Working position: any. Working medium: water. Application of the directive and standards: 2014/30/EC, 2011/65/EC, 1907/2006.
Technical data
- Mln./Max. working pressure : 0.5 bar (7.25 psi)/ 6 bar (87 psi).
- Max. water temperature: 40″C.
- Flowing medium: pure fresh water.
- Functions : battery saving.
- Power supply : 3V
- alkaline battery CR2032 (supplied).
- Flow measurement range: 1-29 I/min.
- Flow measurement: 0 to 999.9 gallons/liter.
- Tolerance of measurement: -/+10%.
- Working time: dependent on the operation of the device.
- Watertight product : yes.
Product Description
(fig. A)
- Quick release plate, [BJ Body with display and hose connection.
General Instructions
Before using the product for the first time please read the genuine user’s manual, follow its instructions, and keep It for later use or subsequent user.
Intended use
This product was developed for home use – it is not intended for industrial applications. The manufacturer shall refuse liability for any damage resulting due to the use of the device Inconsistent with the Intended application as well as Improper operation or assembly thereof. Please supervise children to make sure that they are not playing with the product.
Safety
Do not use the device In drinking water systems. Use the device for clean water only with a maximum temperature of 40″C. The use of turbid, dirty water may cause the meter to stop. Check the device for damage before each use, and discontinue use If there Is damage visible. Do not use any sealants or lubricants to connect the device to the tap. Never pun on the connected hose. Do not install the device near heat sources (max. ambient temperature is 60″C). Do not use the device near energized equipment.
Starting up
Connect the device to the installation. The -now meter starts automatically when the water Is turned on.
Operation
(fig. B)
Automatic water -now measurement. Battery saving mode: the screen wlll go off
If there Is no water flow for 5 minutes or no button Is activated. To activate
the function from the battery saving mode: 1. hold down the CLEAR [1] or RESET
[2] button to activate the meter. 2. The device will detect the fan rotation
(water flow) and start the measuring. Operational steps (flg.C):1. When water
ls flowing: FLOW-A [4] and FLOW-B [5] synchronously count the water flow (fig.
3). 2. To resat FLOW-A [4] to zero, press CLEAR [1], then FLOW-B [5] shows the
total irrigation volume/water flow (fig. 4). 3.
FLOW-A [4] starts counting the water flow from zero, whileFLOW-B [5]
synchronously collects the data from the flow meter (fig. 5).4. To reset
FLOW- A [14] and FLOW-B [5] to zero, hold down the RESET [2] button. The
flowmeter will start counting the water flow from zero.
Description of functions
(fig. B)
CLEAR [1] button – resetting a single measurement. RESET [2] button –
resetting the total measurement. P-MIN [3] water flow rate – shows the current
flow rate in L/min or Gal/ min. FLOW-A [4] – single use water consumption.
FLOW-B [5] – total water consumption. All icons on the display appear when the
device is started.
Setting of displayed parameters
(fig. B)
CLEAR [1] button: by pressing once, a single measurement is reset; by holding
the button for 3 seconds, the function is switched from flow volume to flow
rate or from flow rate to flow volume. RESET [2] button: by pressing once, the
total measurement is reset; by holding the button for 3 seconds, the unit is
switched from litre to gallon or from gallon to litre. Switching the flow rate
to the flow size (fig. 1): By holding down the CLEAR [1] button and then
releasing it, the arrow symbol will start flashing. Select the flow rate or
flow, holding CLEAR [1] again allows you to return to the previous function.
Change of measurement of the converter (gallon/litre) (fig. 2): After pressing
the RESET [2] button for more than 3 seconds, select GAL or LIT. Pressing
RESET [2] again for more than 3 seconds allows you to return to the unit
change.
Maintenance
(fig. A)
Check battery condition. The battery should be replaced when its flashing
symbol appears on the screen.
End of work
The device stops measuring when the water is turned off.
Storage
Store the device out of reach of children in a dry, closed and frost-free place to avoid possible damage.
Disposal
According to directive 2012/19/EU. The device must not be disposed of together with regular household waste. The device must be disposed of in accordance with local environmental regulations.
Troubleshooting
- No indication on the display: Battery discharged > replace the battery; The minimum pressure of 0.5 bar is not achieved > provide 0.5 bar.
- Leakage at the water Loosen the water connection at the tap > screw the connection back on.
52-096KF
012210/2022
Min. 0.5 BAR / 7.25 PSI
Max. 6 BAR / 87 PSI
CR2032 Battery 3V
UK Manufacturer:
Kingfisher International Products Limited, 3 Sheldon Square, London, W2 6PX,
United Kingdom
EU Manufacturer:
Kingfisher International Products B.V. Rapenburgerstraat 175E 1011 VM
Amsterdam The Netherlands
www.kingfisher.com/products
www.diy.com www.screwfix.com
www.screwfix.ie
Keep out of reach of children
Product contains a coin/button cell
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>