BBLove AET-R1B1 Non-Contact Infrared Forehead Digital Thermometer User Manual

October 30, 2023
BBLOVE

BBLove AET-R1B1 Non-Contact Infrared Forehead Digital Thermometer

BBLove-AET-R1B1-Non-Contact-Infrared-Forehead-Digital-Thermometer-
IMGG

Intended use

Thank you for purchasing our Infrared Thermometer, type AET-R1B1. This Infrared Thermometer is a non-sterile, reusable, handheld device. It can be used by consumers in homecare environments and doctors in clinic as a reference. It is intended for measuring the human body temperature of three months and above of people by detecting infrared heat from the center of the forehead.

  • For safe and proper use of this product, be sure to read and fully understand Safety Precautions contained in this user manual.
  • Keep this manual with you for a convenient reference.
  • Keep this manual in a proper way and avoid any loss.
  • If you need other information, please contact the manufacturer (See the PRODUCT INFORMATION).

Quick Start Guide

The correct measurement method to follow: Measure the forehead. Distance 15mm to 50mm.

Correct measurement method

BBLove-AET-R1B1-Non-Contact-Infrared-Forehead-Digital-Thermometer-
Fig-2

  1. Turn the thermometer on by pressing the “ON/OFF/MEASURE* button. To choose mode press “ON/OFF/MEASURE” on the shutoff mode. A beep sound will be heard following which the screen will flash with—°C indicating the unit is ready for use.
  2. Place the thermometer probe point near the forehead and press “ON/OFF/MEASURE” and release after ~ 1 second and the thermometer will beep and display the accurate temperature. Whenever consecutive readings are required, please wait for the -°C to flash. The above procedure can be repeated as many times as required.
  3. To turn off the device press and hold the “ON/OFF/MEASURE” switch for – 5 seconds and the thermometer will turn off automatically after ~ 60 seconds.

Unit description

BBLove-AET-R1B1-Non-Contact-Infrared-Forehead-Digital-Thermometer-
Fig-3

Display information

BBLove-AET-R1B1-Non-Contact-Infrared-Forehead-Digital-Thermometer-
Fig-4

Location indication
The icon flashes to indicate the correct measuring position when measuring.

Temperature data indication
The temperature reading is displayed after measuring.

Temperature unit indication
The unit of measuring temperature shows °C or °F.

Low battery symbol indicates
the icon prompts you to replace the battery when the power is low.

Memory symbol indication
shows in-memory query mode currently.

Load and replace batteries

  • When the battery icon is flashing, please replace a new battery immediately. The steps are as follow:
  • Press and hold the battery cover, and push it upward diagonally to push the cover away. Install 2*AAA batteries as shown in the positive and negative poles.
  • Close the battery cover.

BBLove-AET-R1B1-Non-Contact-Infrared-Forehead-Digital-Thermometer-
Fig-6

Warning
Please take out the battery if you do not use the thermometer for a long time. Please refer to the relevant laws and regulations for the disposal of waste batteries.

Before taking a measurement

  1. It is suggested to try the device by yourself first, so as to know how to use it.
  2. In order to avoid affecting the accuracy of the device due to the external too-cold or too-hot environment, it must be placed in a general environment of room temperature of 16°C-35°C for at least 30 minutes before use to avoid incorrect measurement results.
  3. The person measured should be kept at room temperature for at least 20 minutes to make the body temperature balanced.
  4. After strenuous exercise, you should rest for at least 30 minutes before taking measurements.
  5. Wipe the skin dry and push aside hair strands before commencing.
  6. When repeated measurements are made continuously, move away the probe between each measurement and rest for at least 5s before making the next to obtain the most correct result.
  7. The normal reading value is about 35.5°C~37.8°C. The user should take more temperature to know his or her own health temperature. Pay attention to physical changes or consult your doctor if there is any abnormality.
  8. Check the probe is clean before each measurement to ensure accuracy.

Correct posture to measure

Forehead temperature mode

Measure the forehead, the cap must be close to the forehead.

Instructions for Use

  1. Turn the thermometer on by pressing the “ON/OFF/MEASURE” switch.
  2. A beep sound will be then heard and the screen will then flash – -C. The unit is now ready for use. Place the thermometer’s probe point to the forehead, press “ON/OFF/MEASURE and release after ~ 1 second, the thermometer will beep and display the temperature. If a consecutive reading is required then please wait for the degree °C to flash. Repeat the above procedure as often as required.
  3. Press the “ON/OFF/MEASURE” switch for 5 seconds to turn off the thermometer. Or the unit will switch off automatically after 60 seconds.
    If a reading below 32°C is recorded a “Lo° sign will be displayed followed by 2 consecutive beeps.
    If a reading above 37.8°Cis recorded there will be 6 consecutive beeps.
    If a reading above 42.2°C is recorded a “Hi” sign will be displayed followed by 2 consecutive beeps.

Recalling Readings from Memory

  1. Ensure the thermometer is switched off.
  2. Press the ‘ON/OFF/MEASURE” button for 4 seconds to put the device on memory mode. The last reading will be displayed.
  3. Press and release the “ON/OFF/MEASURE button again to display the next reading in a sequence from the last reading to the first reading.
  4. The thermometer has the memory to recall the last 32 readings.
  5. The thermometer will automatically turn off if it idles for more than 12 seconds.

Changing Temperature Scales

  1. Ensure the thermometer is switched off.
  2. Press the “ON/OFF/MEASURE* button for 8 seconds to bring it into temperature mode. The current temperature unit will be displayed.
  3. Release and press the “ON/OFF/MEASURE” button again to toggle and select between °C and F.
  4. The thermometer will switch off automatically if it idles for more than 4 seconds and will display the last reading.

BBLove-AET-R1B1-Non-Contact-Infrared-Forehead-Digital-Thermometer-
Fig-8

[Explanation of Marks or Symbols)
The following symbols may appear in the manual, Infrared Thermometer and its accessories

Warning

BBLove-AET-R1B1-Non-Contact-Infrared-Forehead-Digital-Thermometer-
Fig-10

Error Messages

BBLove-AET-R1B1-Non-Contact-Infrared-Forehead-Digital-Thermometer-
Fig-11

Maintenance, storage, and calibration

Maintenance

  1. Remove any stains on the body with a soft and dry cloth.
  2. Clean the probe tip as follows: very gently wipe the surface with a cotton swab or soft cloth moistened with clinical alcohol, after the alcohol has completely dried out, you can use the thermometer. If the probe tip is damaged, please contact the maintenance center.
  3. Don’t wash with water or detergent containing abrasive or benzene
  4. Do not immerse in liquids.

Storage

  1. The device must not be stored or used at an excessively high or low temperature or humidity, in sunlight, in association with an electrical current or in dusty locations. Otherwise may occur inaccuracies.
  2. Remove the battery if non-use for long time.

Calibration
This thermometer is calibrated at the time of manufacture. If the thermometer is used according to the instruction, periodic recalibration is not required. If at any time you question the accuracy of the measurement, please contact the retailer immediately. Don’t attempt to modify or reassemble the thermometer.

Technical Specifications

BBLove-AET-R1B1-Non-Contact-Infrared-Forehead-Digital-Thermometer-
Fig-11

Guarantee
Two-year warranty is available from the purchasing date, excluding user- caused failures listed below.

  1. The failure resulted in unauthorized disassembly and modification.
  2. The failure resulted in an unexpected drop during application or transportation.
  3. The failure resulted in the operation away from proper instructions in User’s Manual.

Included in the delivery

  • infrared thermometer
  • Instruction for use
  • 2xAAA batteries

Manufacturer information

  • Manufacturer : Alicn Medical Shenzhen, Inc.
  • Address : 4/F, B Building, Shenfubao Modern Optical Factory,
  • Kengzi Street, Pingshan District, Shenzhen, Guangdong, China, 518122
  • Tel : 0086-0755-26501548
  • Fax : 0086-0755-26504849
  • Email : [email protected]
  • Website : http://www.alicn-med.com

Authorized EU Representative
Shanghai International Holding Corp. GmbH (Europe)
Address: Eiffestrasse 80, 20537 Hamburg, Germany
Tel: +49-40-2513175 Fax: +49-40-255726

Electromagnetic Compatibility

  1. This product needs special precautions regarding electromagnetic compatibility (EMC) and needs to be installed and put into service according to the EMC information provided, and this unit can be affected
    by portable and mobile radio frequency (RF) communications equipment.

  2. Do not use a mobile phone or other devices that emit electromagnetic fields, near the unit. This may result in incorrect operation of the unit.

  3. Caution: This unit has been thoroughly tested and inspected to assure proper performance and operation!

  4. Caution: This machine should not be used adjacent to or stacked with other equipment and if adjacent or stacked use is necessary, this machine should be observed to verify normal operation in the configuration in which it will be used.

BBLove-AET-R1B1-Non-Contact-Infrared-Forehead-Digital-Thermometer-
Fig-12

Guidance and manufacturer’s declaration – electromagnetic immunity – for all EQUIPMENT and SYSTEMS

BBLove-AET-R1B1-Non-Contact-Infrared-Forehead-Digital-Thermometer-
Fig-14

Guidance and manufacturer’s declaration – electromagnetic immunity – for EQUIPMENT and SYSTEM that is not LIFE-SUPPORTING

BBLove-AET-R1B1-Non-Contact-Infrared-Forehead-Digital-Thermometer-
Fig-15

NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies.

NOTE 2 These guidelines may not apply in all situations. Electromagnetic is affected by absorption and reflection from structures, objects, and people.

Field strengths from fixed transmitters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, land mobile radios, amateur radio, AM and FM radio broadcast,s and TV broadcasts cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the Non-contact infrared thermometer is used exceeds the applicable RF compliance level above, the Non-contact infrared thermometer should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as reorienting or relocating the Non-contact infrared thermometer.

Over the frequency range 150 kHz to 80 MHz, what field strengths should he lose then ? lim

Recommended separation distances between portable and mobile RF communications equipment and the EQUIPMENT or SYSTEM – for EQUIPMENT and SYSTEMS that are not LIFE-SUPPORTING

BBLove-AET-R1B1-Non-Contact-Infrared-Forehead-Digital-Thermometer-
Fig-16

For transmitters rated at a maximum output power not listed above the recommended separation distance in meters (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer.

NOTE 1
At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies.

NOTE 2
These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects, and people.

Frequently Aksed Questions

What is the intended use of the BBLove AET-R1B1 Non-Contact Infrared Forehead Digital Thermometer?

It is intended for measuring the human body temperature of three months and above of people by detecting infrared heat from the center of the forehead.

How do I turn on the thermometer?

What is the correct measurement method for using this thermometer?

Measure the forehead from a distance of 15mm to 50mm.

How do I know when the thermometer is ready to use?

A beep sound will be heard following which the screen will flash with---°C indicating the unit is ready for use.

How do I take a temperature reading with this thermometer?

How do I turn off the thermometer?

What should I do if I get a reading below 32°C or above 37.8°C?

How do I recall readings from memory?

Ensure the thermometer is switched off. Press the 'ON/OFF/MEASURE

How do I change the temperature scales?

How do I clean the thermometer?

Remove any stains on the body with a soft and dry cloth. Clean the probe tip as follows: very gently wipe the surface with a cotton swab or soft cloth moistened with clinical alcohol, after the alcohol has completely dried out, you can use the thermometer. If the probe tip is damaged, please contact the maintenance center.

What is the warranty for this thermometer?

Two-year warranty is available from the purchasing date, excluding user-caused failures listed in the user manual.

Download PDF Link:

BBLove-AET-R1B1-Non-Contact-Infrared-Forehead-Digital- Thermometer

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BBLOVE User Manuals

Related Manuals