GIMA QDC-303, P4000IIE Interchangeable Cell Air Mattress Instruction Manual

June 12, 2024
GIMA

GIMA QDC-303, P4000IIE Interchangeable Cell Air Mattress

Product Information

The Professional Medical Products are manufactured by Guangdong Yuehua Medical Instrument Factory Co., Ltd. The specific models included in this range are QDC-303 (GIMA 28564), P4000IIE (B) (GIMA 28565), and QDC-303+P4000IIE (B) (GIMA 28566). These products are made in China.

SUNGO Europe B.V., located at Fascination Boulevard 522, Unit 1.7, 2909VA Capelle aan den IJssel, The Netherlands, is the authorized distributor of these medical products in Europe. Gima S.p.A, located at Via Marconi, 1 – 20060 Gessate (MI) – Italy, is the manufacturer and can be contacted at gima@gimaitaly.com or export@gimaiatly.com. More information can be found at www.gimaitaly.com.

Product Usage Instructions

Professional Medical Products have the following specifications:

  • Weight: QDC-303 – 2.3kg, P4000IIE (B) – 1.4kg
  • Maximum Load Capacity: 135kg
  • Power Supply: ~ 220V 50Hz
  • Maximum Current: 0.1A
  • Fuse Type: T1A 250V

Please follow these instructions to use the product:

  1. Ensure that the power supply is compatible with ~220V 50Hz.
  2. Connect the product to the power source using the appropriate power cable.
  3. Make sure the maximum load capacity of 135kg is not exceeded.
  4. Refer to the user manual for specific instructions on how to operate the QDC-303, P4000IIE (B), or QDC-303+P4000IIE (B) models.
  5. In case of any issues or inquiries, contact the manufacturer or authorized distributor for assistance.

For further details on usage and safety precautions, please refer to the complete user manual provided with the product.

Installation

GIMA-QDC-303,-P4000IIE-Interchangeable-Cell-Air-Mattress-
fig-1

Wiring diagram

GIMA-QDC-303,-P4000IIE-Interchangeable-Cell-Air-Mattress-
fig-2

Instructions

A BUBBLE MATTRESS consists of two parts: the mattress and the pump. The pump is a small-sized compressor uses, to ensure quiet and high energy value efficiency. The control panel is easy can be used. The mattress relieves the pressure in the order of alternating deflation and inflation, 6 minutes in measured time. It is widely known that the constant pressure of the bony bump is the main cause of skin injuries. The continuous movement of the unit reduces areas of constant pressure and increases circulation.

Use

  1. Place the mattress on the bed frame with the flexible hose outlet at the foot of the structure.
  2. Use the built-in hooks to hang the pump on the end of the bed or place it on a straight and flat area.
  3. Connect the mattress air hose to the pump.
  4. Connect the pump to a wall outlet. Check the supply pipes for possible hazards be away.
  5. Press the power button on the pump control panel. The pump starts to inflate the mattress.
  6. After inflation, control the mattress with the control button of the pump.

Attention

  1. Do not smoke near the mattress.
  2. Keep the pump away from heat sources.
  3. Risk of explosion when used near flammable anesthetics.
  4. Replace the fuse as described in T1A 250V. Power supply: ~ 220V 50Hz, 0.1A

Product Features

Sizes

MATTRESS (length x width x height)| 200cm×90cm×7cm
Valve extension| 50cm mindkét oldalon
PUMP (length x width x height)| 25cm×12cm×10cm
WEIGHT OF THE PRODUCT
MATTRESS WEIGHT| 2.3kg
PUMP WEIGHT| 1.4kg
YIELD
MAXIMUM PATIENT WEIGHT| 135kg
ELECTRICAL CHARACTERISTICS
SUPPLY IN OPERATION| ~ 220V 50Hz, 0.1A MAX
MELTING FUSE:| T1A 250V
ENVIRONMENTAL CONDITIONS
OPERATING CONDITIONS|
Ambient temperature| 10°C – 40°C (50°F – 104°F)
Relative humidity| 10% – 75%
STORAGE AND DELIVERY CONDITIONS|
Room temperature| -18°C – +43°C (0°F – 110°F)
Relative humidity| 10% – 95%

Cleaning Instructions

Mattress
Clean the mattress regularly with a neutral detergent or alcohol. Heat or steam sterilization cannot be used.

Pump

  • Clean the pump regularly with a neutral detergent or alcohol.
  • Do not open the pump housing – risk of electric shock
  • Do not get the pump wet or immerse it in any liquid

Disposal:
It is forbidden to dispose of the product together with household waste. Users must ensure the disposal of devices awaiting disposal by dropping off electrical and electronic devices at designated collection points for recycling.

GIMA WARRANTY TERMS

The 12-month Gima B2B standard warranty applies.

You must report any serious incident that has occurred in connection with the medical device we supply to the manufacturer to the competent authority of the Member State in which you are established.

  • QDC-303 (GIMA 28564)
  • P4000IIE (B) (GIMA 28565)
  • QDC-303+P4000IIE (B) (GIMA 28566)

Guangdong Yuehua Medical Instrument Factory Co., Ltd.
Rongsheng Science and Technology Zone, Daxue Road, Shantou, Guangdong, China.

Made in China.

SUNGO Europe B.V.
Fascinatio Boulevard 522, Unit 1.7, 2909VA Capelle aan den IJssel, The Netherlands.

Gima S.p.A
Via Marconi, 1 – 20060 Gessate (MI) – Italy
gima@gimaitaly.comexport@gimaiatly.com
www.gimaitaly.com.

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>